Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Similar documents
Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

you can We have an eye for detail. CF-1 HIGH RESOLUTION DIGITAL RETINAL CAMERA Camera Canon EOS 1Ds Mark III f7.1 1/800 ISO 320

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Coherence Tomography Retina Scan Duo

Optical Coherence Tomography. RS-3000 Advance

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Coherence Tomography. RS-3000 Advance / Lite

CX-1 digital retinal camera mydriatic & non-mydriatic. Redefining true versatility.

Optical Coherence Tomography. RS-3000 Advance 2

you can Portable Digital Radiography. Going places. CXDI-501G DIGITAL RADIOGRAPHY SYSTEM

The First True Color Confocal Scanner on the Market

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

Impressive Wide Field Image Quality with Small Pupil Size

The First True-Color Wide-Field Confocal Scanner

Our vision is foresight

The First True Color Confocal Scanner

Fourier Domain (Spectral) OCT OCT: HISTORY. Could OCT be a Game Maker OCT in Optometric Practice: A THE TECHNOLOGY BEHIND OCT

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

Blood Vessel Tree Reconstruction in Retinal OCT Data

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CR-2 AF DIGITAL NON-MYDRIATIC RETINAL CAMERA. Superior Image Resolution and Auto Functionality

OCT - Anatomy of a Scan. OCT - Anatomy of a Scan. OCT Imaging. OCT Imaging

SPECTRALIS Training Guide

Fundus Photograph Reading Center

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

ISO Ophthalmic optics and instruments Instruments to measure axial distances in the eye

3D OCT-2000 / 3D OCT-2000

Medical imaging has long played a critical role in diagnosing

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture

Slit Lamp Adapted Optical Coherence Tomography SL SCAN-1 CONNECTING VISIONS

ioct Discover the next generation of efficiency enhancement

Better diagnosis and treatment all-in-one.

Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm

OCT mini-symposium. Presenters. Donald Miller, Indiana Univ. Joseph Izatt, Duke Univ. Thomas Milner, Univ. of Texas at Austin Jay Wei, Zeiss Meditec

DRCR.net Image Acquisition Protocol

This document is a preview generated by EVS

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

SUPPLEMENTARY INFORMATION

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

Submission of Figures to the Japanese Journal of Ophthalmology

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Introduction. Chapter Aim of the Thesis

Visual Optics. Visual Optics - Introduction

Software User Manual Slitlamp Adapted OCT SL SCAN-1. PC Software Edition v.3.6.2

Optimizing Performance of AO Ophthalmic Systems. Austin Roorda, PhD

Image Modeling of the Human Eye

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

Biology 70 Slides for Lecture 1 Fall 2007

TRC-NW400 Non-Mydriatic Retinal Camera

Large-field high-speed polarization sensitive spectral domain OCT and its applications in ophthalmology

Medical Photonics Lecture 1.2 Optical Engineering

2 The First Steps in Vision

Version 1.0. th March 2011

OCULUS Pentacam AXL Always an Axial Length Ahead

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Wide Angle Ophthalmoscope Instructions

EYE ANATOMY. Multimedia Health Education. Disclaimer

DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000

Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique

The Eye. Nakhleh Abu-Yaghi, M.B.B.S Ophthalmology Division

Introduction. scotoma. Effects of preferred retinal locus placement on text navigation and development of adventageous trained retinal locus

Automatic and manual segmentation of healthy retinas using high-definition optical coherence tomography

TEPZZ A_T EP A1 (19) (11) EP A1. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

OCT-A. Perimetry. Slit lamps. Retinal imaging OCOCTT. Microperimetry. Ultrasound. Lasers. HAAG-STREIT UK Product Portfolio

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Eye. Eye Major structural layer of the wall of the eye is a thick layer of dense C.T.; that layer has two parts:

Axsun OCT Swept Laser and System

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

Training Eye Instructions

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos 200Tx Imaging Protocol. Version 3.0 9/19/16

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol. Version /14/14

Goldmann Visual Field. Humphrey Visual Field 4/25/2017. What s So Special About Special Testing?! Houston, we have a problem.

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

General Discussion. Chapter Development of the Instrument

INSTRUCTION MANUAL 3D OPTICAL COHERENCE TOMOGRAPHY

Handout G: The Eye and How We See

The Confocal Tonal Shift

Non-Mydriatic Auto Fundus Camera AFC-330

Retinopathy From a Green Laser Pointer

Vision Research 51 (2011) Contents lists available at SciVerse ScienceDirect. Vision Research

Instruments Commonly Used For Examination of the Eye

All-Glass Ophthalmic Lenses

PSY 214 Lecture # (09/14/2011) (Introduction to Vision) Dr. Achtman PSY 214. Lecture 4 Topic: Introduction to Vision Chapter 3, pages 44-54

Department of Ophthalmology, Perelman School of Medicine at the University of Pennsylvania

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

Procedure to measure the sulcus to sulcus distance by the Sonomed VuMAX II in patients to be implanted with the Staar ICL

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

Directional and nondirectional spectral reflection from the human fovea

The Photoreceptor Mosaic

The Puzzle of Light and AMD

Fundus Photograph Reading Center

Glaucoma Advanced, LAbel-free High resolution Automated OCT Diagnostics GALAHAD

Binocular retinal eye-tracking system Product Requirements Document C. Light Technologies, Inc.

Volume 115(11) November 1997 pp

Transcription:

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Full Auto OCT High specifications in a very compact design Automatic functions make examinations short and simple. Perform the examination with only two simple mouse clicks! The Canon OCT-HS100 is the first Fully Automated Spectral Domain OCT. Operating an OCT has never been easier. Full Auto The OCT-HS100 s Full Auto feature significantly simplifies operation; standard procedures can easily be delegated and results are operator independent. High Image Quality. 3µm axial optical resolution 1. START Auto alignment Auto focus Auto C-gate 2. CAPTURE The OCT-HS100 s extensive automatic functions simplify and optimize examinations. A single mouse click correctly aligns and focuses on the retina to maximize scan quality. The operator then decides with a second click when the scan itself will be initiated, allowing full control over the instrument. The high scan speed of 70,000 A-scans/sec results in very short examination times typically under two seconds improving efficiency and resulting in a very patient-friendly experience. Canon s expertise in optics and innovative technology has resulted in a fantastic 3µm optical axial resolution for amazing scan quality. The built in Scanning Laser Ophthalmoscope (SLO) allows for high quality retinal observations and precise follow up examinations. Auto anterior eye alignment and tracking The OCT-HS100 will automatically maintain the exact alignment on the center of the eye. Auto Fundus tracking by SLO By detecting the amount of movement in fundus images, the unit can automatically compensate for small involuntary movements of the eye. Auto C-gate control (Coherence Gate) Scan depth is automatically adjusted. Auto Focus Automatic compensation of patient refraction. 10 mm scan width Increased effectiveness of examinations by capturing large areas with just one scan. Easy examinations Five stored examination sets: Macula Disease, Glaucoma, Choroid, Anterior and General. Examinations for other retinal diseases can be easily created in the initial settings menu. High scanning Speed 70,000 A-scans per second allow two-second examinations for reduced risk of motion artefacts and increased patient comfort. Extensive connectivity The unit can be used stand-alone or in a network. Tomograms or reports can be output as JPEG, BMP or DICOM file. Built in SLO For high quality retinal observation and precise follow up examinations 2 3

Main Features Extensive software 3µm axial resolution 3 micron resolution for unsurpassed image quality Capture Screen The capture screen displays a clear image of the anterior eye segment and retina (by SLO) as well as the OCT preview. The capture screen allows full control of the OCT-HS100: examination sets, fixation target, alignment and focusing. Averaging Up to 50 scans can be combined for the highest possible image quality Macula analysis* Full retinal significance map Full retinal deviation map Full retinal difference map IS/OS - RPE thickness map RPE deformation map Inner retinal thickness map Outer retinal thickness map [NFL+GCL+IPL] thickness map ETDRS sectors Full retinal measurements table Central sector thickness Minimum fovea thickness Total area average thickness Total volume Full retinal time-line graph 3D object 10 layer recognition The OCT-HS100 can recognize ten boundaries of the retina; detection of Bruch s membrane (BM) is now possible Macula glaucoma analysis* RNFL thickness map RNFL deviation map RNFL significance map ILM-RPE thickness map NFL+GCL+IPL deviation map NFL+GCL+IPL significance map NFL+GCL+IPL sectors NFL+GCL+IPL time-line graph NFL+GCL+IPL measurement table Choroid and Vitreous mode Using Enhanced Depth Imaging, two modes can be selected based on the pathology: Choroid Mode (left) for detection of choroidal neovascularization. Vitreous Mode (below) for the detection of epiretinal membranes or vitreo macular traction; Disc analysis* 3.45mm circle reconstruction tomogram RNFL thickness RNFL deviation map RNFL significance map RNFL thickness profile ONH measurement table RNFL measurement table RNFL sectors RNFL time-line graph SLO tracking follow-up SLO tracking allows accurate follow up examinations using the same scan position and identical scan parameters: Scan mode, position and size, fixation target position and size. * For these analyses a Normative Database will be available in a next version of the OCT-HS100 software 4 5

Extensive scan modes Clinical images Macula 3D An area scan is done centering on the macula., for examination of the macula and the deeper layers Scan size 10 x 10 mm Glaucoma 3D A vertical area scan of the macula for extensive analysis of the NFL+GCL+IPL Scan size 10 x 10mm Cross High resolution scan with up to 50 times averaging for highest image quality Multi Cross Mult purpose high resolution scans with up to 10 times averaging. Macular Edema Disc 3D Area scan for disc analysis Scan size 6 x 6 mm Anterior 3D* Area scan is perfromed on the anterior segment. Scan size 6 x 6 mm Macular Dystrophy Custom General application, for analysis of any disease Anterior cross* High resolution cross scan, for imaging cornea and angle. * With optional adapter Retinal Image Import with automatic overlay Imported retinal camera images are automatically aligned and overlaid on to the SLO image with precise position matching. Posterior Epithelium Detachment Flexible Layout The OCT-HS100 takes up very little floor space and is flexible for use in most situations even against a wall or in a corner. Specifications Age-related Macular Degeneration A-scans/sec Max 70,000 Fundus Preview Fs SLO Axial resolution 3 µm Observation light source 780 ± 5nm Transversal Resolution 20 µm Internal Eye Fixation 2 mm or 6mm, 590nm (orange) Pupil size requirement Min 3.0 mm Field of view 10 x 10 mm, OCT 33 O x 33 O, SLO 44 O x 33 O Scanning width 2 ~10 mm Dimensions (WxDxH) 387 x 499 x 474 (mm) Scan depth 2 mm Weight 29 (kg) OCT light source 855 nm ±5 nm Optional Accessory Anterior segment adapter (ASA-1) Working Distance 35 mm Images courtesy of Karolinska Institutet, Sweden 6 7

Canon has been defining the future with innovative solutions for more than 70 years. In all that time we ve constantly strived to improve medical diagnostics in healthcare. Perhaps that s what made us a leading global provider of eye care solutions. Canon Eco Canon Quality Canon Flexibility Our actions are based on honesty and sustainability. Safety and quality are an integral component of our actions. Everything we do has to have a superior customer advantage. Choose the eye care system of the future and let our local, authorized Canon dealer advise you: OCT-HS100 English-NL Edition 2166V375 Canon Europa N.V. 2013 Canon Europa N.V. Medical Systems Division Bovenkerkerweg 59 61 1185 XB Amstelveen The Netherlands Phone: +31(0)20-5 45-89 26 Fax: +31(0)20-5 45-82 20 www.canon-europe.com/medical