NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

Similar documents
NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

Cat# 71440A LED Classic Large Wall-Pack

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

REVOLUTION LIGHTING TECHNOLOGIES INC

QPL ID # PLG2YNJ831VZ

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

71352A QPL ID # PLT2P2L2UNWR. RoHS

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

RoHS QPL ID # PLC6V1PABNUJS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Cat# 71146A 150W Trunion Mount

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

Cat# LED High Bay

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ


Cat# LED Classic MINI Wall-PACK

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Eternal Shine Technology Co.,Ltd. EST


Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Cat# LED Wall-PACK

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

LM Test Report

LM Test Report

LM Test Report

LM Test Report

LM Test Report

Photometric Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Photometric Test Report

Photometric Test Report

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Cat# LED Classic Large Wall-Pack

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Test Report

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Morris Products 53 Carey Road, Queensbury, NY 12804

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Morris Products 53 Carey Road, Queensbury, NY 12804

Transcription:

LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating are the same, except CCT Test & Report By: Johnson Sun Engineer: Johnson Sun Update: Nov.28, 2016 Review By: Manager: Tommy Liang Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 1 / 11

1.1 Product Information: Organization Name WESTGATE MFG. Brand Name Model Number SKU (if available) N/A Type of Luminaire (for integral lamps, Outdoor Non-Cutoff and Semi -Cutoff Wall-mounted Area list base type and lamp type) Luminaires Rated Voltage / Frequency 100-277Vac, 50/60 Hz Nominal Power 50W Rated Initial Lamp Lumen -- Declared CCT 4000K,5000K LED Manufacturer Philips Lumileds LED Model LUXEON 3030 2D Sample Number GZE161105-S1(4000K),S2(5000K) Luminaire Aperture (for downlights) -- in. Luminaire Length -- mm Luminaires Width -- mm Number of Units (modular products) N/A s Photo 2 / 11

1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard Reference Work Instruction : Nov.21,2016 : Nov.22,2016 1. Total Luminous Flux 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. Electrical Parameters 1. IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products 2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products 3. CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering Properties of Light Sources 4. CIE 15-2004 Technical Report Colorimetry 5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source 6. IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems QD25 1.3 Test Methods 1) Photometric and Light Distribution Measurement Goniophotometer Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2) Chromaticity Measurement Sphere-Spectroradiometer Method: Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ± 1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral power distribution taken at 5 nm intervals over the range of 380 to 780 nm. 3) Electrical Measurements: Electrical parameters were measured using power meters incorporated in goniophotometer or sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at 25ºC ± 1ºC. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion were measured by and read from the power meter. 3 / 11

2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2016-11-22 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number WML-50NW Electrical Measurement : Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE161105-120.0 60 0.4091 47.99 0.9776 12.59 S1 277.0 60 0.1891 47.42 0.9054 16.37 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method : Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 72 R9 0 Frequency (Hz) 60 R2 78 R10 47 CCT (K) 4001 R3 82 R11 70 Duv 0.0008 R4 74 R12 42 Chromaticity (x, y) x=0.3810 y=0.3788 R5 71 R13 72 Chromaticity (u, v ) u'=0.2246 v'=0.5026 R6 69 R14 89 Color Rendering Index (CRI) 73.0 R7 81 R15 66 R9 0 R8 58 -- -- Photometric Measurement Goniophotometer Method : Parameter Result DLC V4.0 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 Total Luminous (lm) 5848.0 5964.5 -- Luminous Efficacy (lm/w) 121.86 125.78 Total Luminous (lm)(0-90 ) 4726.7 4633.5 >=300 (-10%) Luminous Efficacy (lm/w)(0-90 ) 98.49 97.71 Standard: >= Premium: >= 95(-3%) 115(-3%) Zonal lumens in the (80-90 )/(0-90 ) zone (%) 12.9 -- <=10(3) Beam Angle ( ) 102.3 -- -- Center Beam Candle Power (cd) 1170 -- -- 4 / 11

Spectral Power Distribution & Chromaticity Diagram Zonal Lumen Tabulation Zonal Lumen Summary Lumens Per Zone Zone Lumens % Luminaire Zone Lumens % Total Zone Lumens % Total 0-30 789.0 13.2% 0-40 1,347.0 22.6% 0-60 2,712.3 45.4% 60-90 2,014.4 33.7% 70-100 1,797.3 30.1% 90-120 1,064.7 17.8% 0-90 4,726.7 79.2% 90-180 1,242.2 20.8% 0-180 5,968.9 100% 0-10 104.4 1.7% 90-100 499.3 8.4% 10-20 273.2 4.6% 100-110 352.0 5.9% 20-30 411.4 6.9% 110-120 213.4 3.6% 30-40 558.1 9.3% 120-130 109.4 1.8% 40-50 672.3 11.3% 130-140 45.8 0.8% 50-60 693.0 11.6% 140-150 16.5 0.3% 60-70 716.3 12.0% 150-160 4.7 0.1% 70-80 688.1 11.5% 160-170 0.9 0% 80-90 609.9 10.2% 170-180 0.2 0% 5 / 11

6 / 11

7 / 11

BUG Rating: B1-U4-G4 8 / 11

2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2016-11-22 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number WML-50CW Electrical Measurement : Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE161105-120.0 60 0.4101 48.15 0.9785 12.53 S2 277.0 60 0.1895 47.58 0.9063 16.31 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method : Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 73 R9 0 Frequency (Hz) 60 R2 75 R10 39 CCT (K) 5098 R3 74 R11 74 Duv -0.0017 R4 74 R12 45 Chromaticity (x, y) x=0.3421 y=0.3458 R5 73 R13 72 Chromaticity (u, v ) u'=0.2117 v'=0.4814 R6 66 R14 85 Color Rendering Index (CRI) 71.9 R7 77 R15 69 R9 0 R8 63 -- -- Photometric Measurement Sphere-Spectroradiometer Method : Parameter Result DLC V4.0 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 Total Luminous (lm) 5969 6088 -- Luminous Efficacy (lm/w) 123.97 127.95 Total Luminous (lm)(0-90 ) 4824 4729 >=300 (-10%) Luminous Efficacy(lm/W)(0-90 ) 100.19 99.39 Standard: >= Premium: >= 95(-3%) 115(-3%) 9 / 11

Spectral Power Distribution & Chromaticity Diagram 10 / 11

3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R-336 2 meter Integrating Sphere 2016-07-01 2017-06-30 ST-R-331 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30 D204 Standard Lamp 2016-07-01 2017-06-30 PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30 EE-09 Goniophotometer system 2016-07-01 2017-06-30 D908S Standard Lamp 2016-07-01 2017-06-30 PF210 Power Meter for Goniophotometer 2016-07-01 2017-06-30 ST-R-181A Temperature Tester 2016-07-01 2017-06-30 Uncertainty: Photometric Measurement (Sphere):1.74% Chromaticity Measurement(Sphere):14.3K Photometric Measurement(Goniophotometer):1.62% ****** END OF REPORT ****** 11 / 11