Energetic Analysis of the Drying Process of Current Transformers from 110 kv Ciungetu Power Station

Similar documents
Modeling and Performances of an Induction Heating System with Resonant Voltage Inverter for Drying of Current Transformers from Ciungetu Power Station

Using dspace in the Shunt Static Compensators Control

High Performance Shunt Active Power Filter: Design Consideration and Experimental Evaluation

Case Study Survey of Harmonic Pollution Generated by Railway Systems and Filtering Solutions

ISSN Vol.03,Issue.07, August-2015, Pages:

Simulation Results on the Currents Harmonics Mitigation on the Railway Station Line Feed

Harmonic Distortions Analyzer for Power Rectifiers

ELECTROMAGNETIC POLLUTION PRODUCED BY THE INDUSTRIAL FREQUENCY CRUCIBLE INDUCTION FURNACES IN THE POWER SUPPLY NETWORK

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

Nonconventional Technologies Review no. 4/2009

Researches Regarding the Pollution with Harmonics by the Frequency Converters

Improving Passive Filter Compensation Performance With Active Techniques

Buck-boost converter as power factor correction controller for plug-in electric vehicles and battery charging application

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Development of a Single-Phase PWM AC Controller

Simulation of H bridge Inverter used for Induction Melting Furnace

Functioning Analysis of a High Frequency Electro Thermal Installation with Electromagnetic Induction Using PSCAD-EMTDC Tool

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Harmonic Filtering in Variable Speed Drives

Voltage and Current Waveforms Enhancement using Harmonic Filters

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Design and Analysis of Resonant Harmonic Filter

THE ANNALS OF DUNAREA DE JOS UNIVERSITY OF GALATI FASCICLE III, 2006 ISSN X ELECTROTECHNICS, ELECTRONICS, AUTOMATIC CONTROL, INFORMATICS

Single Phase Bridgeless SEPIC Converter with High Power Factor

SYSTEM OF CONTROLLING THE PROCESS OF STEEL ELABORATION IN DC ELECTRIC ARC FURNACES

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Diagnosis of Water Tree Aging in XLPE Cable by the Loss Current Harmonic Component Under Variable Frequency Power

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

Australian Journal of Basic and Applied Sciences. Design of a Half Bridge AC AC Series Resonant Converter for Domestic Application

Investigation of D-Statcom Operation in Electric Distribution System

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

A Series-Resonant Half-Bridge Inverter for Induction-Iron Appliances

Power Quality enhancement of a distribution line with DSTATCOM

Harmonic Analysis to Improve Power Quality

Auxiliary DC Voltage

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

A High Power, High Quality Single-Phase AC-DC Converter for Wireless Power Transfer Applications

POWER FACTOR CORRECTION OF ELECTRONIC BALLAST FOR FLUORESCENT LAMPS BY BOOST TOPOLOGY

5-Level Parallel Current Source Inverter for High Power Application with DC Current Balance Control

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Prediction of Transient Transfer Functions at Cable-Transformer Interfaces

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Sizing the neutral wire cross-section and minimization of neutral currents using microgeneration in low voltage networks

ON THE TRANSIENTS OPTIMIZATION AND THE POWER FACTOR CORRECTION OF THE STATIC CONVERTERS

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

HARMONIC contamination, due to the increment of nonlinear

Enhancement of Power Quality Using Advanced Series Active Power Filters

2020 P a g e. Figure.2: Line diagram of series active power filter.

Laboratory Investigation of Variable Speed Control of Synchronous Generator With a Boost Converter for Wind Turbine Applications

Contents. Core information about Unit

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

CHAPTER 4 PI CONTROLLER BASED LCL RESONANT CONVERTER

FREQUENCY TRACKING BY SHORT CURRENT DETECTION FOR INDUCTIVE POWER TRANSFER SYSTEM

Performance Analysis of Control techniques of Full-Bridge Resonant Inverter for Induction Metal Surface Hardening

UNDERSTANDING SUB-HARMONICS

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

SIMULATION TOOL FOR POWER QUALITY ANALYSIS

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

Voltage Support and Reactive Power Control in Micro-grid using DG

Design and Simulation of Passive Filter

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Study of Power Loss Reduction in SEPR Converters for Induction Heating through Implementation of SiC Based Semiconductor Switches

TO LIMIT degradation in power quality caused by nonlinear

CHAPTER 4 HARMONICS AND POWER FACTOR

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Improved Battery Charger Circuit Utilizing Reduced DC-link Capacitors

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Analysis of a Passive Filter with Improved Power Quality for PV Applications

Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Control of grid connected inverter system for sinusoidal current injection with improved performance

Medium Voltage Drives in Industrial Applications. By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Active Harmonic Filter (AF3)

High Frequency Isolated Series Parallel Resonant Converter

Harmonic distortion from induction furnace loads in a steel production plant

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

Efficiency Improvement of High Frequency Inverter for Wireless Power Transfer System Using a Series Reactive Power Compensator

STUDIES ON WAVES AND OSCILLATIONS WITH DATA ACQUISITION SYSTEMS *

Downloaded from / 1

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS

Study of Centralized Anti-Islanding Method on Large-Scale Photovoltaic Power Plants

Design of EMI Filters for DC-DC converter

ATYPICAL high-power gate-turn-off (GTO) currentsource

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

Transcription:

Annals of the University of Craiova, Electrical Engineering series, No. 4, 6; ISSN 84-485 Energetic Analysis of the Drying Process of Current Transformers from kv Ciungetu Power Station Dinu Roxan Doboşeriu *, Alexandru Bitoleanu and Mihaela Popescu * S.S.H. Hidroserv Ciungetu, Râmnicu Vâlcea, Romania, doboseriu_constantin@yahoo.com University of Craiova, Faculty of Electrical Engineering, Craiova, Romania, alex.bitoleanu@em.ucv.ro Abstract - Currently, at company Hidroserv Râmnicu Vâlcea, the drying of current transformers used in power transformer stations is done by a combination between induction and conduction heating at the frequency of 5 Hz. Obviously, this solution is outdated in terms of technology and the performed energetic analysis proves it. In order to achieve the design of a multifunction static system intended to replace the existing one, so as to respond as best as possible to the specific needs, it is necessary to analyze the drying process from energetic point of view. The knowledge of the equivalent parameters of the loads is needed too. To substantiate the feasibility of this new technical solutions, the goal of the paper is the analysis of the actual technology from energetic point of view. Considering that the current transformer of the kv power station Ciungetu is the typical load, experimental determinations relating to the its drying process have been performed. Two heating coils are used, of 33 turns and 38 turns, respectively. In order to determine the associated parameters for both coils, the current and voltage across the equivalent induc tor have been recorded by using an oscilloscope Tektronix TDS3. It is obvious, and the performed energetic analysis demonstrates this, the solution currently used is outdated in terms of technology. Keywords: current transformer, electric drying, experimental recording, harmonics, numeric filtration. I. INTRODUCTION In the operation of current transformers from transformer stations of hydropowers, their resistance of isulation can become lower that the limits imposed by norms. Consequently, it is necessary to dry them. The wetting of the insulation can be due to the loss of tightness between component parts and to the atmospheric moisture penetration because the insulating oil is hygroscopic. The Norm PE6/94 for tests and measurements on electrical equipment requires that, for current transformers working at voltages in the domain kv 4 kv, the insulation resistance value to be greater than 5 M. Otherwise, their connection to the line voltage is not allowed. The drying of the current transformers can be done through various methods: by outdoor heating, by heating with current from an independent source, by heating with short-circuit current, through ventilation, through active iron losses into the transformer. In cases where through a certain method it fails to obtain the necessary drying temperature or when heating of different parts is not uniform, two methods are combined [], []. Currently, at Hidroserv Râmnicu Vâlcea, a combination of the induction heating at the industrial frequency and the conduction heating is the adopted solution to dry the current transformers used in the power transformer stations. Given the technological processes that use heating, in order to have a high degree of flexibility, it is considered that a static multifunction system is required. It could provide both DC and AC energy and, in the same time, allow the adjustment of the frequency and power level [3] - [3]. After introduction, this paper contains three background sections and ends with some conclusions. In the following section, the structure currently used for drying by induction and conduction heating is presented and some details on the apparatus used for recording the current and voltage are given. The next section is dedicated to the processing of the recorded data, needed for the graphical representation and harmonic analysis. Because the forms contain high frequency noise, their filtration is done with first order filters having the cutting frequency of khz. Then, the electric powers in system and the total power factor are calculated by using both unfiltered and filtered forms. Finally, some conclusions are drawn. II. EXPERIMENTAL SETUP The current transformer that must be dried is covered with an insulating film of textolit, over which a coil that has shape of a truncated cone is achieved (Fig. ). The size of the obtained coil depends on number of its turns. The conductor used is made of flexible copper class 5 according to EN 68, profile stranded (wire diameter of.5 mm), with an outer diameter of 5.8 mm. In this way, the parameters variation depending on the frequency can be neglected. The power supply is ensured by using the autotransformer of a source for welding capable to adjust the output voltage in large limits. Two structures of the induction heating coil have been achieved, as follows:. Coil with 33 turns, when the rms values of the voltage and current are 59 V and 5 A;. Coil with 38 turns, when the rms values of the voltage and current are 56 V and 3 A. In order to determine the associated parameters for both coils, the current and voltage across the equivalent induc- 74

Annals of the University of Craiova, Electrical Engineering series, No. 4, 6; ISSN 84-485 Fig.. Detail about the drying of current transformers in actual technology. tor have been recorded by using an oscilloscope Tektronix TDS3. The current has been recorded by a shunt.5mω/mv precision class.% [4]. The acquisition frequency was khz. For the subsequent use in the calculation of the parameters, the forms of the two quantities have been filtered by means of first order filters having a period of -4 seconds. Thus, a significant attenuation of the high order harmonics has been achieved (Fig. ). It is estimated that the value of 4 rad/sec for the cutting pulsation represents an acceptable compromise between the mitigation of the high order harmonics and how the phases of the first 3 harmonics are affected. Thus, for a lower value of the cutting pulsation, the mitigation of the high order harmonics could be more pronounced, but the phases changing of the first 3 harmonics would become inacceptable. Conversely, a higher value of the cutting pulsation would not mitigate sufficiently the magnitude of the high order harmonics. III. WAVEFORMS AND HARMONIC ANALYSIS As it can be seen in Fig. 3, the form of the acquired current in the case of the coil with 33 turns contains harmonics of high frequency. Their presence is due to the induced voltages by the electromagnetic disturbances existing in the external environment. The harmonics spectra of the raw and filtered forms of the current show that the harmonics up to order 3 have very little influence and the most apparent of these are of orders from to 6 and (Fig. 4). Two indicators have been taken into consideration to quantify the degree of harmonic distortion, i.e. [5], [6]: - The total harmonic distortion factor (THD), I THD, () I where I and I are the global rms value of the current and the fundamental rms value, respectively; - The partial harmonic distortion factor (PHD), N Ik k PHD, () I where N is the order of the last harmonic taken into consideration. It was obtained that the total harmonic distortion factor for the unfiltered is 6.33% and the partial harmonic distortion factor corresponding to the first 3 harmonics is.63%. As regards the filtered form of the current, the total distortion factor is 3.8% and the partial harmonic distortion factor associated to the first 3 harmonics is.54%. It can be seen that the last one is slightly lower than the corresponding value related to the unfiltered (.63%). It follows that the filtering process does not affect the low order harmonics, impacting on energetic quantities. As illustrated in Fig. 5, the high frequency noises contained in the acquired form of the voltage are lower. The harmonic spectrum shows that the highest weight corresponds to the harmonics, 3, 5 and (Fig. 6. g Magnitude (db) Phase (deg) - -4-45 -9 3 4 5 6 f=3xf f=f=5hz Frequency [Rad/sec] Fig.. Bode diagrams of the first order filter. 75

Annals of the University of Craiova, Electrical Engineering series, No. 4, 6; ISSN 84-485 3 3 - - - - -3.5..5. -3.5..5. Fig. 3. The form of current for the coil with 33 turns: recorded; filtered. Fig. 4. Harmonic spectra of the current (p.u.) for the coil with 33 turns: for the acquired ; for the filtered. THD=,76% 5-5 THD=,34% 5-5 -.5..5. -.5..5..8.6.4. Fig. 5. The form of voltage for the coil with 33 turns: recorded; filtered. THD=,76% PHD=,33% 3 4.8 PHD=,3%.6.4. THD=,34% 3 4 Fig. 6. Harmonic spectra of the voltage (p.u.) for the coil with 33 turns: acquired ; filtered. 76

Annals of the University of Craiova, Electrical Engineering series, No. 4, 6; ISSN 84-485 3 3 - - - - -3.5..5. -3.5..5. Fig. 7. The form of current for the coil with 38 turns: recorded; filtered. Current Harmonics Magnitude [pu].8.6.4. THDI=6,83% PHDI=3,36% 3 4 Current Harmonics Magnitude [pu].8.6 THD=3,49% PHD=3,3%.4. 3 4 Fig. 8. Harmonic spectra of the current (p.u.) for the coil with 38 turns: acquired ; filtered. 5 5-5 -5 -.5..5. -.5..5. Fig. 9. The form of voltage for the coil with 38 turns: recorded; filtered..8.6.4. THD=,53% PHD=,5% 3 4.8.6.4. THD=,6% PHD=,49% 3 4 Fig.. Harmonic spectra of the voltage (p.u.) for the coil with 38 turns: acquired ; filtered. 77

Annals of the University of Craiova, Electrical Engineering series, No. 4, 6; ISSN 84-485 The total harmonic distortion factor of the unfiltered and filtered s of voltage is.76 % and.34 % respectively. The partial distortion factors by considering only the first 3 harmonics have the values.33 % for the raw and.3 % for the filtered. As it can be seen from Fig. 4 and Fig. 6, the weight of harmonic of order 3 is. % for voltage and.5 % for current. This aspect and the very close values of the partial harmonic distortion factors show that the consideration of the first 3 harmonics is enough. In the case of the 38 turns coil, the phenomena are similar in terms of quality aspects (Fig. 7-Fig. ). There are, however, few quantitative differences, as follows: - The total harmonic distortion of the current is 6.83 % for the acquired and 3.49 % after filtration; - The partial harmonic distortion of the current is 3.36 % for acquired and 3.3 % for after filtration; - The total harmonic distortion of the voltage is lower, respectively it is.53 % for the unfiltered and.6% for the filtered ; - The partial harmonic distortion of the voltage is lower, that is.5% for unfiltered and.49% for filtered ; - The weight of the harmonic voltage of order 3 is about.66 %; - The weight of the harmonic current of order 3 is about.35 %. It must be mentioned that the measurements for the two coils were performed on different days. Accordingly, the supply conditions were not identical. Even the frequency of the supply voltage was different, namely 5.5 Hz in the case of coil with 33 turns and 5 Hz in the case of coil with 38 turns. IV. ENERGETIC ANALYSIS In order to perform the energetic analysis, the active power (P), the apparent power (S) and the global power factor (PF) have been calculated. The following expressions have been implemented by modeling under MATLAB/Simulink software: - for the active power, - for the apparent power, u t P t i d ; (3) T S U I ; (4) - for the global power factor, which is a synthetic indicator on powers, P PF. (5) S The rms values values of the voltage and current (U and I), which intervene in (4), have been implemented through their definitions [6]: U t u t T d ; (6) I t i t T d. (7) The power that could be compensated (P C ) has been calculated too, P C S P, (8) and its weight in the active power (W CP ) and apparent power (W CS ) are expressed as: PC WCP ; (9) P PC WCS. () S It must be noted that the power that could be compensated to reach the unity power factor contains both the reactive power and the distortion power [6]. In the same time, the undimensional indicators WCP and WCS are a measure of additional expenses because of unussed power. The numerical results given in Table I show that the energetic performances are weak. Thus, low values are obtained the the global power factor (about 38 % for the coil with 33 turns and about 45 % in the case of the coil with 38 turns). If it is obvious that the drying process by heating the current transformer is more effective if the coil covers better the transformer s height and the number of turns of the coil is higher. This second aspect is confirmed by the results shown in Table. TABLE I. THE NUMERICAL RESULTS OF ENERGY PARAMETERS Coil 33 turns 38 turns Filtered Unfiltered Filtered Unfiltered Frequency 5.5 Hz 5 Hz U [V] 49.4 49.43 49.4 49.44 I [A] 53.5 53.8 38.3 38.6 P [W] 885 887 39 393 S [VA] 7583 76 683 685 PF.386.3798.4595.455 P C[VA] 73 73 693 63 W CP [%] 43.8 43.55 97. 97.64 W CS [%] 9.48 9.5 89.8 89.3 The need to search for new sources and technologies based on the heating process, dedicated to the drying of the current transformers and other components of the hydropower plants, is better illustrated by the high values of indicators W CP and W CS. Thus, the power that could be compensated represents about 9 % of the apparent power and % of the active power. 78

Annals of the University of Craiova, Electrical Engineering series, No. 4, 6; ISSN 84-485 V. CONCLUSIONS. The detailed energetic analysis of the drying process by heating of a current transformer from a power station in a hydropower plant shows that the existing technology and equipment are energy-intensive.. The data obtained through this analysis can be used to calculate the equivalent parameters of the system, which are required in identification and the design of new equipment with better energy performance. 3. The power that could be compensated, with favorable consequences on the supply system, is about.5 times higher than the active power. 4. A simple solution to compensate this useless power is to use a compensation capacitor connected in parallel with the inductor. 5. It is estimated that a complete way to improve the energetic performances requires supplying from a static system based on a resonant voltage inverter. 6. A multifunction static system able to provide both AC and DC voltage, continuously adjustable in large limits, may be obtained by supplying the voltage source inverter from either a fully controlled rectifier or a half controlled rectifier. Received on July 7, 6 Editorial Approval on November 5, 6 REFERENCES [] R. G. Ghemke, Defectele masinilor electrice, Editura Tehnică, București, 96. [] Felicia Anghel Sprânceană., D. Anghel, Metode şi procedee tehnologice. vol. II. Tehnologii moderne, Printech, București, 6. [3] M. K. Kazimierczuk, D. Czarkowski, Resonant power converters, John Wiley & Sons,. [4] A. Bitoleanu, D. Mihai, Mihaela Popescu, C. Constantinescu, Convertoare statice şi structuri de comandă performante, Sitech, Craiova,. [5] V. Suru, Mihaela Popescu, A. Bitoleanu, Energetic performances of induction heating systems with voltage resonant inverter, Proceedings of International Symposium on Electrical and Electronics Engineering, October -3, Galaţi, România, 3. [6] A. Bitoleanu, Mihaela Popescu, V. Suru, Maximizing power transfer in induction heating system with voltage source inverter, The nd International Conference on Nonlinear Dynamics of Electronic Systems, Albena, Bulgaria, 4. [7] V. Esteve, J. Pardo, J. Jordan, E. Dede, E. Sanchis-Kilders, E. Maset, High power resonant inverter with simultaneous dualfrequency output, 36th Power Electronics Specialists Conference, 5, pp. 78-8. [8] S. Dieckerhoff, M. J. Ruan, R. W. De Doncker, Design of an IGBT-based LCL-resonant inverter for high-frequency induction heating, The 34th Industry Applications Conference, vol. 3, Oct. 3-7, 999, pp. 39 45. [9] F. P. Dawson, P. Jain, A comparison of load commutated inverter systems for induction heating and melting applications, IEEE Transactions on Power Electronics, vol. 6, no. 3. July 99, pp. 43-44. [] A. Suresh, R. S. Rama, Parallel resonance based current source inverter for induction heating, European Journal of Scientific Research, vol. 58, no.,, pp. 48-55. [] Mihaela Popescu, A. Bitoleanu, E. Subţirelu, design and performance of the voltage control loop in induction heating systems with L-LC resonant inverters, Annals of the University of Craiova, Electrical Engineering Series, no. 37, 3, pp. 39-43. [] S. Chudjuarjeen, A. Sangswang, C. Koompai, An Improved LLC resonant inverter for induction-heating applications with asymmetrical control, IEEE Transactions on Industrial Electronics, vol. 58, issue 7, July, pp. 95-95. [3] P. Sreenivas, R. Vaddi, J.S. Ranganayakulu, Full bridge resonant inverter for induction heating applications, International Journal of Engineering Research and Applications (IJERA), vol. 3, issue, Jan.-Feb. 3, pp. 66-73. [4] K. Agoston, Instrumentatie si masurari electrice, Matrixrom, Bucuresti, 9. [5] Mihaela Popescu, Electronique de puissance: composants semiconducteurs et convertisseurs, Universitaria, Craiova, 6. [6] A. Bitoleanu, Mihaela Popescu, Filtre active de putere, Universitaria Craiova,. 79