H DS 5 S er ies C -DC P ower S upplies 5 W atts x x x S er ies High Efficiency up to 9% High Power Density Programmable O utput Voltage ( 5%) Programmable O utput Current ( 5%) Parallel O peration Fully Featured Signals & Controls 3 Year W arranty The HDS 5 series offers users both output voltage and output current programming ( 5%) via resistance, voltage or I C bus in a very high efficiency, high power density 3 kw chassis mount package. Measuring just.3 x.5 x 5., the HDS 5 also features active current sharing, remote on/off, remote sense and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5 V at.5 or 9V at.3. Dimensions: HDS5:.3 x.5 x 5. (94.5 x 63.5 x 7 mm) Models & Ratings Output P ower Output Voltage V Output C urrent Min Max E ffic ienc y () Model Number 5 W. VDC. 5. 89% HDS 5PS 5 W 5. VDC.. 9% HDS 5PS 5 5 W 4. VDC. 6.5 9% HDS 5PS 4 5 W 3. VDC. 5. 9% HDS 5PS 3 5 W 36. VDC. 4.7 9% HDS 5PS 36 5 W 48. VDC. 3.3 9% HDS 5PS 48 5 W. VDC. 5. 93% HDS 5PS N o te s. Measured with VC input and full load. Input Input Voltage 9 64 VC S ee derating curve Input Frequency 47 63 Hz Power Factor.99/.98 5/ VC full load Input C urrent 8/9 5/ VC Inrush C urrent 3.// 5/ VC E arth Leakage C urrent. m 64 VC / Hz Input Protection F /5 V internal fuse
H DS 5 S er ies C -DC P ower S upplies Output Output Voltage VDC S ee Models and R atings table Output Trim ±5. % B y potentionmeter Output Voltage Program 5 % Of rated output Output Current Program 5 % Of rated output Initial S et ccuracy ± % Minimum Load S tart Up Delay s S tart Up R ise Time ms t full load Hold Up Time 8 ms Line R egulation ± % Load R egulation ±/±3 % -% load. V/ standby Transient R esponse % For a 5% step load change R ipple & Noise % pk-pk.5% for V model. Measured with MHz bandwidth and using twisted pair wire terminated with. µf ceramic capacitor and 47 µf electrolytic. Overvoltage Protection Overtemperature Protection Tracks output voltage, see application notes R ecycle C to reset Primary and secondary heatsinks, monitored Output shuts down, auto recovers Overload Protection 5 % R ated power, constant current S hort Circuit Protection uto recovery Temperature Coefficient ±. % / C -5 C R emote S ense Enable Current S hare 5 supplies can share within 5% S tandby Output C ompensates for.5 V max voltage drop, if remote sense is not required, local sense must be used Output must be enabled, see application notes, power supply is shipped with enable links fitted 5 V at.5, present whenever C is applied (9 V at.3, user selectable, by connecting VS ET, Pin 8 of C N to ) O u t p u t V o lt a g e P r o g r a m m in g Via External Voltage Via External Resistor Output Voltage (%) Output Voltage (%) 3 4 4.5 4.8 5 3 4 4.5 4.8 5 Programming Voltage (VDC) Resistor Value (kω ) O u t p u t C u r r e n t P r o g r a m m in g Via External Voltage Via External Resistor Output Current (%) Output Current (%) 3 4 4.5 4.8 5 3 4 4.5 4.8 5 Programming Voltage (VDC) Resistor Value (kω )
H DS 5 S er ies C -DC P ower S upplies General Efficiency 89 93 % S ee Models and R atings table Isolation: Input to Output Input to Ground Output to Ground S witching Frequency 3 VC 5 VC 5 VC 65 khz P FC khz P WM, variable Power Density 9.7 W/in 3 S ignals and Controls E nable, C urrent S hare, V Program, I Program, 5 V S tandby, Power OK Mean Time B etween Failure 5 khrs MIL-HDB K -7F, 5 C GB Weight 5.7 (.6) lb (kg) Environmental Operating Temperature -5 C S torage Temperature - 85 C C ooling Humidity 9 % R H Vibration g Derate linearly from % load at 5 C to % load at C Internal fan fitted, speed increases with load and internal temperature -5 Hz, min/cycle, min period for each axis, compliant to IEC68--6, IEC 68--64 D e r a t in g C u r v e Thermal Derating C urve Input Derating C urve Load (% ) Load (% ) 9 7 5-3 5 7 mbient Temperature ( C ) 9 64 Input Voltage (VC ) 3
H DS 5 S er ies C -DC P ower S upplies Signals & Controls LE D S tatus S olid (Green) S olid (Orange) S low B link (Green) Fast B link (R ed) S olid (R ed) S low B link (R ed) Intermittent B link (R ed) S hort & Long B link (R ed) Output S tatus DC Output OK DC Output OK in remote control mode Output Not Enabled Over Voltage Over Loaded Over Temperature Fan Fail S tandby Failure R e m o t e E n a b le K Ω 5 V S B E N E N- S W OFF Power OFF ON Power ON KΩ 5 V S B E N E N- L H Power OFF Power ON KΩ 5 V S B E N S W E N- OFF Power OFF ON Power ON L / H () Using internal 5 V standby (B ) Using external transistor (C ) Using external voltage source EMC: Emissions Phenomenon S tandard Test Level Notes & Conditions Conducted EN55 Class B R adiated EN55 Class B Harmonic Currents EN-3- Class Voltage Flicker EN-3-3 EMC: Immunity Phenomenon S tandard Test Level Criteria Notes & Conditions E S D Immunity E N-4- / 3 ±4 kv contact / ±8 kv air discharge R adiated Immunity EN-4-3 3 EFT/B urst EN-4-4 3 S urge EN-4-5 Installation class 3 C onducted E N-4-6 3 Magnetic Field EN-4-8 3 Dips and Interruptions EN554 DIP : 3% 5 ms /B High Line/Low Line INT: >95% ms INT: >95% 5 ms B Safety pprovals S afety gency S afety S tandard Notes & Conditions UL UL95- CS C. No.95- TUV E N95-4
4 4 4 4 4 4 4 H DS 5 S er ies C -DC P ower S upplies pplication N otes P O K S ig n a l O V P S e t t in g POWER SUPPLY 5 V uxiliary 33R % 96% OVP Trip Point Pok Power not OK Power OK % 4% CN Connect or 7% % 5% Open drain signal, low when P S U turns on Maximum sink current: m Maximum drain voltage: V NC % of Nominal Output Voltage C u r r e n t S h a r in g w it h R e m o t e S e n s e R e m o t e S e n s e E CN - Load 4 4 4 4 4 L o c a l S e n s e C u r r e n t S h a r in g w it h L o c a l S e n s e CN - Load 4 Must be used if remote sense is not required. 4 4 4 4 N o t e s In parallel operation, it is possible that only one unit will operate if the load is less than 5% of the combined rated output load. It is possible to have more than five units in parallel, contact sales for details. 5
H DS 5 S er ies C -DC P ower S upplies Mechanical Details.57 (4.5).4 () 9.843 (5).59 (5).5 (63.5) 4-M4 L=5. (.) 3.858 (98) 5. (7).57 (4.5).3 (33).339 (34) 9.33 (7) M8.378 (35) 8-M4 (both sides) L=5. (.) CN Control Pin Connections P in Func tion Des c ription P in F unc tion Des c ription P in F unc tion Des c ription VS R emote sense () 9 Inhibit On/Off(-) 7 /.5 or 9V/.3 S tandby power Positive Output Voltage Ground 8 Ground 3 VS - R emote S ense (-) E N Inhibit On/Off () 9 S C L I C S erial C lock 4 Negative Output Voltage /.5 or 9V/.3 S tandby power S D I C S erial Data 5 Power OK 3 I Program /.5 or 9V/.3 uxiliary power 6 G round 4 G round G round 7 Parallel Operation Current S hare 5 V Program N.C. R S R eceive 8 VS ET ux Output S etting 6 Ground 4 N.C. R S Transmit N o te s. ll dimensions are in inches (mm).. Weight 4. lb (.9 kg) 3. Maintain (5mm) clear space at each end. 4. Mating connector CN: PHDR -4VS housing, PHD-T-P5 contacts 5 May 6