MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors

Similar documents
MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors for Cellpack separable connectors

KEVA B Indoor voltage sensor

Medium Voltage Products. KECA 80 C85 Indoor current sensor

KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

AT Current Instrument Transformer Instructions for installation, use and maintenance

Sensors VOLTAGE AND CURRENT SENSORS FOR INTELLIGENT TRANSFORMER SUBSTATIONS.

SIGMA F+E 3 Short-Circuit and Earth Fault Indicator

Sensor Technology. Applications for medium voltage

Cable connection. 58 RM6 catalogue schneider-electric.com

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Multimeter 500CVD21 RTU500 series

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22

Three-phase monitoring relays CM-PFE and CM-PFE.2

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Digital Indicator DS 96/48 PK

Three-phase monitoring relay

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Pluggable interface relays CR-U Universal relays

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Three-phase monitoring relay CM-PVE

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Transformers connected via a cable Overvoltage protection

The Polytransformer. The Multivoltage Substation Power Transformer

Three-phase monitoring relay CM-PBE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ChuteMaster Microwave-blocked chute detection and point level instrument

Provisional Specifications

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Digital Indicator DS 96/24

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

Alternative Testing Techniques for Current Transformers. Dinesh Chhajer, PE Technical Support Group MEGGER

KINAX SR 719 Programmable Transmitter for Position Feedback

ABB MEASUREMENT & ANALYTICS. TALYS ASP500 series Flexible analyzer for real-time control of chemical processes

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

Power transformers. Shunt reactors Proven history for future success

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Time relay RXKA 1. (xx jpg) RXKA 1

Selection of MO surge arresters Overvoltage protection

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

Current / residual current and voltage transformers. Current / residual current and voltage transformers

APPROVAL SHEET 12V/2A EA1019HHUS(03) EA1019HHUS-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

1/23/2003. Sensor presentation

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

CEC VIBRATION TRANSMITTER

Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24

REF42plus HMI Cutting Tool Operating Guide

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

1-830 SERIES DISPLACEMENT TRANSMITTER

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

LST100 Ultrasonic level transmitter for upstream oil and gas

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Electronic Products and Relays Selection Table Signal Converters CC-Range

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

KINAX 2W2 Programmable Transmitter for Angular Position

LST400 Ultrasonic level / open channel flow transmitter

50-SDMS-01 SPECIFICATIONS FOR

Transcription:

MEDIUM VOLTAGE PRODUCTS KEVA C Indoor voltage sensors

2 KEVA C INDOOR VOLTAGE SENSORS 01 Resistive divider principle 02 IED and sensor Parameters for Application Rated primary voltage of application Sensor Parameters Value up to 24 kv Value U P U s = R 2 U p Rated primary voltage, U pn 22/ 3 kv R 1 + R 2 Highest voltage for equipment, U m 24 kv Rated power frequency withstand voltage Rated lightning impulse withstand voltage Rated transformation ratio, K n for voltage measurement Voltage accuracy class Length of cable 50 kv 125 kv 10 000:1 0.5/3P 2.5; 5; 8; 10 m 01 U S In all cases, the transmitted output signal reproduces the actual waveform of the primary voltage signal. Sensor principles Electronic Instrument Transformers (Sensors) offer an alternative way of making the voltage measurement needed for the protection and monitoring of medium voltage power systems. Sensors based on alternative principles have been introduced as successors to conventional instrument transformers in order to significantly reduce size, increase safety, and to provide greater rating standardization and a wider functionality range. These well known principles can only be fully utilized in combination with versatile electronic relays. Sensor characteristics Construction of ABB s voltage sensors is done without the use of a ferromagnetic core. This fact results in several important benefits for the user and the application. The main benefit is that the behavior of the sensor is not influenced by non-linearity and width of hysteresis curve, which results in a highly accurate and linear response over a wide dynamic range of measured quantities. A linear and highly accurate sensor characteristic in the full operating range enables the combination of metering and protection classes in one device. Protection and control IEDs (Intelligent Electronic Devices) Protection and control IEDs incorporate the functions of a traditional relay, as well as allow new additional functions. The information transmitted from the sensors to the IED is very accurate, providing the possibility of versatile relay functionality. However, the IED must be able to operate with sufficient accuracy at a sensor s low input signal level. Modern IEDs (such as ABB s 615 series relays) are designed for such sensor use. Modern digital apparatuses (microprocessor based relays) allow protection and measurement functions to be combined. They fully support voltage sensing realized by the single sensor with double the accuracy class designation (e.g.: voltage sensing with combined accuracy class 0.5/3P). Voltage sensor Voltage measurement in KEVA C sensors is based on the resistive divider principle. The output voltage is directly proportional to the input voltage: 02

3 03 KEVA C application Sensor applications The voltage sensors type KEVA C are intended for use in voltage measurement in gas insulated medium voltage switchgear. The voltage sensors are designed as easy replacement of originally used insulating plugs in the cable connectors. Due to their compact size and optimized design sensors can be used for retrofit purposes as well as in new installations. Sensor variants Sensor type designation KEVA 24 Cxy Metal coated (conductive surface) Picture KEVA 24 Cxyc Tab. 1. Sensor design variants (with and without conductive surface) Note: Voltage sensor KEVA 24 C30 is available only in sensor design variant without conductive surface. 03 Sensor type designation KEVA 24 C10 KEVA 24 C10c KEVA 24 C21 KEVA 24 C21c KEVA 24 C22 KEVA 24 C22c KEVA 24 C23 KEVA 24 C23c Cable connectors Manufacturer Type Connecting screw for sensor Nexans-Euromold Cellpack Prysmian Südkabel ABB Kabeldon NKT TE connectivity TE connectivity NKT 400 TB/G, K400 TB/G 440 TB/G, K440 TB/G 400 PB/G, K400 PB/G 400 PB-xSA (for x= up to 24kV) 400 BE/G-E, K400 BE/G-E 944 TB/G, K944 TB/G 400 TE/G, K400 TE/G CTS-S 630A FMCTs-400 FMCTs-400/1250 (C/D) FMCTXs-630/C MSCT/EC-630-C SEHDT 13, 23 MUT 33 CSE-A 12630, CSE-A 24630 CSEP-A 12630, CSEP-A 24630 SOC 630 (older) CSAP-A 6/12/24 kv CB 12-630, CB 24-630 CC 12-630, CC 24-630 CBC 40,5 630 (max for 24 kv) CSA M12, CSA M16 CB 36-400 (for max 24 kv) RSTI L56xx RSTI-CC L56xx RSTI 58xx/39xx RSTI-CC 58xx/39xx RSTI LCxx/LAxx (older) CB 12-630, CB 24-630 CC 12-630, CC 24-630 CBC 40,5 630 (max for 24 kv) CSA M12, CSA M16 M16 M16 M12 M16 (For use in NKT connectors with M16 screw shall be used the correct screw)

4 KEVA C INDOOR VOLTAGE SENSORS 04 Combined accuracy class Sensor type designation KEVA 24 C24 KEVA 24 C24c KEVA 24 C25 KEVA 24 C25c KEVA 24 C26 KEVA 24 C26c Cable connectors Manufacturer Type Connecting screw for sensor Nexans-Euromold Prysmian Cellpack Südkabel 430 TB/G, K430 TB/G 300 PBM/G-630A, K300 PBM/G-630A 300 SA FMCEAs 630/400 MSCEA/EC-630-C CTS 630A 24kV CTKS 630A 24 kv CTKSA SET 12, 24, SAT 12,24 SEHDK 13.1, 23.1, SAK 12,24 SEHDT 23.1 MUT 23, MUT 23.1 AD 23.1 SP KEVA 24 C30 TE connectivity RICS 51x3, 51x9, 51x7 M16 M16 M16 M16 Tab. 2. Sensor variants and use in cable connectors Note: For use in alternative cable connectors please contact ABB. Differences between Sensors and Instrument Transformers There are some noticeable differences between Sensors and conventional Instrument Transformers: Linearity Due to the absence of a ferromagnetic core the sensor has a linear response over a very wide primary voltage range. Example of voltage measurement range for metering accuracy class 0.5 and protection accuracy class 3P: The accuracy limits are described on the graph below. ε[%] +6% +3% +0.5% -0.5% 04-3% -6% Protection accuracy limit class 3P Metering accuracy limit class 0.5 Sensor linear characteristic 0.02*U pn 0.8*U pn U pn 1.2*U pn 1.9*U pn U p Rated parameters Because the sensors are highly linear within a very wide range of voltages, the same single sensor can be used for the va rious rated voltages associated with each specific application up to the specified maximum voltage for equipment. There is no need to specify other parameters such as burden etc. since they are standard over the defined range. To achieve the correct function of the protection and control IED, the selected rated voltage as well as the rated transformation ratio, must be properly set into the IED. Correction factors The amplitude and phase error of a voltage sensor is, in practice, constant and independent of the primary voltage. Due to this fact it is an inherent and constant property of each sensor and it is not considered as unpredictable and influenced error. Hence, it can be easily corrected in the IED by using appropriate correction factors, stated se parately for every sensor. Values of the correction factors for the amplitude and phase error of a voltage sensor are mentioned on the sensor label (for more information please refer to Instructions for installation, use and maintenance) and should be uploaded without any modification into the IED before the sensors are put into operation (please check available correction in the IED manual). To achieve required accuracy classes it is recommended to use both correction factors (Cfs): amplitude correction factor (au) and phase error correction factor (pu) of a voltage sensor.

5 05 Example of a sensor label 06 Connector RJ-45 Standards IEC 60044-7 (1999-12) Instrument transformers - Part 7: Electronic voltage transformers Highest voltage for equipment and test voltages Highest voltage for equipment, U m : 24 kv Rated power frequency test voltage: 50 kv Rated lightning impulse test voltage: 125 kv 05 Voltage sensor, rated values Rated primary voltage, U pn : 22/ 3 kv Rated frequency, f r : 50/60 Hz Accuracy class: 0.5/3P Rated burden, R br : 10 MΩ Rated transformation ratio, K n : 10 000:1 Rated voltage factor, k u : 1.9/8h Secondary cables The sensor is equipped with a cable for connection with the IED. The cable connector is type RJ-45. The sensor accuracy classes are verified up to the connector, i.e. considering also its secondary cable. These cables are intended to be connected directly to the IED, and subsequently neither burden calculation nor secondary wiring is needed. Every sensor is therefore accuracy tested when equipped with its own cable and connector. Temperature category Operation: Transport and storage: Cable Length: Connector: Grounding wire length: -25 C/+80 C -40 C/+80 C 2.2; 5; 8; 10 m RJ-45 (CAT-6) 0.5 m 06 Connector adapters To provide connectivity between a sensor with a RJ-45 cable connector and IEDs with Twin-BNC connectors a group of adapters were designed. To provide connectivity between current and voltage sensors with RJ-45 cable connectors and IEDs with RJ-45 connector the coupling adapter was designed. The use of connector or coupling adapters has no influence on the current and/or voltage signal and accuracy of the sensor with the cable. For more information about connector adapters and coupling adapter refer to Doc. No. 1VLC000710 - Sensor accessories.

6 KEVA C INDOOR VOLTAGE SENSORS Sensor type designation Secondary cable length 2.2 m 5 m 10 m 8 m KEVA 24 C10 1VL5400061V0101 1VL5400061V0103 1VL5400061V0102 1VL5400061V0104 KEVA 24 C10c 1VL5400061V0201 1VL5400061V0203 1VL5400061V0202 1VL5400061V0204 KEVA 24 C21 1VL5400062V0101 1VL5400062V0103 1VL5400062V0102 1VL5400062V0104 KEVA 24 C21c 1VL5400062V0201 1VL5400062V0203 1VL5400062V0202 1VL5400062V0204 KEVA 24 C22 1VL5400063V0101 1VL5400063V0103 1VL5400063V0102 1VL5400063V0104 KEVA 24 C22c 1VL5400063V0201 1VL5400063V0203 1VL5400063V0202 1VL5400063V0204 KEVA 24 C23 1VL5400064V0101 1VL5400064V0103 1VL5400064V0102 1VL5400064V0104 KEVA 24 C23c 1VL5400064V0201 1VL5400064V0203 1VL5400064V0202 1VL5400064V0204 KEVA 24 C24 1VL5400078V0101 1VL5400078V0103 1VL5400078V0102 1VL5400078V0104 KEVA 24 C24c 1VL5400078V0201 1VL5400078V0203 1VL5400078V0202 1VL5400078V0204 KEVA 24 C25 1VL5400079V0101 1VL5400079V0103 1VL5400079V0102 1VL5400079V0104 KEVA 24 C25c 1VL5400079V0201 1VL5400079V0203 1VL5400079V0202 1VL5400079V0204 KEVA 24 C26 1VL5400080V0101 1VL5400080V0103 1VL5400080V0102 1VL5400080V0104 KEVA 24 C26c 1VL5400080V0201 1VL5400080V0203 1VL5400080V0202 1VL5400080V0204 KEVA 24 C30 1VL5400081V0101 1VL5400081V0103 1VL5400081V0102 1VL5400081V0104 with M16-M12 adapter KEVA 24 C23 1VL5400064V0301 1VL5400064V0303 1VL5400064V0302 1VL5400064V0304 KEVA 24 C23c 1VL5400064V0401 1VL5400064V0403 1VL5400064V0402 1VL5400064V0404 Tab. 3. Ordering numbers by sensor type and cable length

7 Dimensional Drawings KEVA 24 C10(c) Outline drawing numbers: 2RKA015654A0001 (KEVA 24 C10) 2RKA015654A0002 (KEVA 24 C10c)

8 KEVA C INDOOR VOLTAGE SENSORS KEVA 24 C21(c) Outline drawing numbers: 2RKA017064A0001 (KEVA 24 C21) 2RKA017064A0002 (KEVA 24 C21c)

9 KEVA 24 C22(c) Outline drawing numbers: 2RKA017065A0001 (KEVA 24 C22) 2RKA017065A0002 (KEVA 24 C22c)

10 KEVA C INDOOR VOLTAGE SENSORS KEVA 24 C23(c) Outline drawing numbers: 2RKA017066A0001 (KEVA 24 C23) 2RKA017066A0002 (KEVA 24 C23c)

11 KEVA 24 C24(c) Outline drawing numbers: 2RKA019520A0001 (KEVA 24 C24) 2RKA019520A0002 (KEVA 24 C24c)

12 KEVA C INDOOR VOLTAGE SENSORS KEVA 24 C25(c) Outline drawing numbers: 2RKA019522A0001 (KEVA 24 C25) 2RKA019522A0002 (KEVA 24 C25c)

13 KEVA 24 C26(c) Outline drawing numbers: 2RKA019784A0001 (KEVA 24 C26) 2RKA019784A0002 (KEVA 24 C26c)

14 KEVA C INDOOR VOLTAGE SENSORS KEVA 24 C30 Outline drawing number: 2RKA020039A0001 (KEVA 24 C30)

CONTACT US ABB s.r.o. EPDS Brno Videnska 117, 619 00 Brno, Czech Republic Tel.: +420 547 152 082 +420 547 152 854 Fax: +420 547 152 626 E-mail: kontakt@cz.abb.com www.abb.com NOTE We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB. Copyright 2018 ABB All rights reserved 1VLC000717 Rev.6, en 2018.11.28