Continuous, remote monitoring and logging of electromagnetic fields

Similar documents
Narda EMF drive test solution

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields

Frequency selective monitoring and logging of environmental electromagnetic fields

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Making sure of a healthy environment. Narda EMF Monitors. Improving safety in electromagnetic fields

Analysis of static and time-variable magnetic fields

Selective and broadband low frequency field analysis

Monitoring electric and magnetic fields

Selective and broadband low frequency field analysis

Monitoring electric and magnetic fields

For Isotropic Measurement of Magnetic and Electric Fields

Selective and broadband high frequency field analysis

Monitoring electric and magnetic fields

Safety Evaluation Within a Magnetic Field Environment

Safety Evaluation Within a Magnetic Field Environment

Selective and broadband low frequency field analysis

Selective and broadband low frequency field analysis

Features of Spectrum Analysis mode

SRM When Safety Counts SRM SRM-3006 Selective Radiation Meter for electromagnetic fields up to 6 GHz

Parameters in Scope mode

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

SRM: WHEN SAFETY COUNTS. SRM-3006: SELECTIVE RADIATION METER FOR ELECTROMAGNETIC FIELDS UP TO 6 GHz

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

SRM-3006 Reliably measuring actual HF immissions

Nardalert S3 and RadMan / RadMan XT Personal Monitors. Personal Monitors Nardalert S3 and RadMan / RadMan XT

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Low Frequency. Precision test equipment for safety in electric and magnetic fields

Advanced Test Equipment Rentals ATEC (2832)

Operation of Short Wave broadcast transmitting stations

Safety in electromagnetic fields. EMF Directive 2013/35/EU

Evaluation of exposure to pulsed magnetic fields by examining the variations in the spectrum and over time with ELT-400

Selective measurement of high frequency electric and magnetic fields

Narda DF Antennas - Datasheet. Datasheet

User s Manual PMM 8053B

Selective measurement of high frequency electric and magnetic fields

Selective measurement of high frequency electromagnetic

Where Safety Matters, Use The Latest Technology

Jammers. Interference and Direction Analyzer IDA 2. Application Note

Accredited calibration of field strength meters

Field Probes Frequency range Level range

Personal & Area Monitors

> Product category: > Function: > User profi le: > Frequency band: 100 KHz to 6 GHz. > Related standard: ECC/REC/(02)04, EN > Related software:

Selective measurement of high frequency electromagnetic

Capturing IQ data with NRA and IDA

SignalShark. NSTS 1017-E0328B / SignalShark Datasheet Subject to change without notice

MAGNETIC FIELD METER Operator s Manual

SignalShark - Preliminary Datasheet* Real-Time Handheld Analyzer

Safety in high frequency electromagnetic fields

SRM-3000 Selective Radiation Meter

FREQUENCY-SELECTIVE, ISOTROPIC MEASUREMENT, EVALUATION, AND RECORDING OF HIGH FREQUENCY ELECTROMAGNETIC FIELDS

Dive deep into interference analysis. Interference Direction Analyzer

Exposure Level Tester ELT-400

Dive deep into interference analysis. Interference Direction Analyzer

OPERATIONS MANUAL. narda MODEL 8513 INDUSTRIAL COMPLIANCE METER. for Electromagnetic Energy. Safety Test Solutions. P/N Rev B

SignalShark Real-Time Remote Analyzer

Safety Test Solutions. SRM-3006 Selective Radiation Meter. Selective Radiation Meter

MAGNETIC FIELD METER Operator s Manual

R-Log Radio data logger

Supervision and analyse of the electrical network EN50160 & POWER QUALITY

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS

DATAMAR 2000 MICROWAVE (26 GHz) RADAR TIDE GAUGE

Multifunctional Microwave Analyzer

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

mod. BT 20 / GSM 2004

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

TRMC-19 GSM/GPRS DATALOGGER. Applications. Product description. Measure and remote monitoring

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Main Features. Highlights

Technical Note 2. Ultra Wideband Electromagnetic Radiation Monitor. narda

Dive deep into interference analysis

Advanced Test Equipment Rentals ATEC (2832)

Network Analyzer for Low-, Medium- and High-Voltage Networks

Willtek. Handheld Spectrum Analyzer

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

JD723A/JD724B/JD726A Cable and Antenna Analyzers

ExpoM - ELF User Manual

MEASURING INSTRUMENTS AND TESTERS

THE CONNECTED INFRASTRUCTURE SOLUTION MONITORING HOW STRUCTURES EVOLVE

R&S EB500 Monitoring Receiver Specifications

AERINOS Profisens - Wireless IoT Platform

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

EMI Measuring Receiver & Analyzer 10 Hz-3 GHz

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

8GHz RF EMF Strength Meter

3 AXIS RF ELECTROMAGNETIC FIELD METER

METRAClip87 and 88 Clamp Multimeters

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

SLX-1 Multi-Application GNSS Receiver

FX180 OCA. Platform Highlights. Key Features

Wireless LAN network. Wireless USB network

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

Wireless systems.

PQM3000R Class A network analyzer according to EN for power quality monitoring

Spectrum Analyzer R&S FS300

Immission measurements in the vicinity of LTE base stations

GPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

FREEDOM Communications System Analyzer R8100 DATA SHEET

Transcription:

NARDA EMF MONITORS AMB-8059 Continuous, remote monitoring and logging of electromagnetic fields Interchangeable probes from 10 Hz to 40 GHz for low frequency & high frequency applications Multi-band probes for telecommunications monitoring Simultaneous monitoring of electric and magnetic fields Fully autonomous operation: Solar panel power supply depending on model Built-in 2G/3G modem depending on model Built-in Wi-Fi Ethernet port depending on model Automatic data transfer Daily reports, warnings & alarm messages via SMS On-board GPS Easy integration into test environments and Web Based Applications Low weight, robust design, compact size for indoor and outdoor operation Area Monitor AMB-8059/03 with Solar Panel INTRODUCTION Narda EMF Monitors are equipped with exclusive, state-of-the-art sensors having high sensitivity, accuracy and reliability. Their robust, uncluttered construction is perfect for long-term outdoor installation. The AMB-8059 handles applications from a few Hertz through to long wave and on up to high frequency microwave radiation using a selection of interchangeable probes for electric and magnetic fields. NSTS 0617-E0313E 1 / 10 Subject to change without notice

Minimum outlay, maximum result An EMF monitoring system is made up from a series of EMF monitors installed wherever the EMF presence needs to assessed continuously or by long term observation. The EMF monitors store the data and report them using conventional mobile data communication at set time intervals to a central unit, e.g. PC or data server. The system size can range from a single location up to countrywide coverage. Narda EMF monitors combine all the features that are essential for this purpose: autonomy, outdoor usability, mobility, robustness, and low operating costs. You can be certain to find the ideal solution for every area of application with Narda. And you can depend on its reliability, thanks to our decades of experience coupled with cutting edge technology, backed up by our own certified calibration laboratory. The AMB Series Its broadband application is the optimum solution for technical superiority from a tight budget. Four models are available: Unit designation AMB-8059/03 AMB-8059/02 AMB-8059/01 AMB-8059/00 Solar panel (24/7) & back-up battery Inbuilt 2G/3G modem Wi-Fi Ethernet port Optical link GPS Battery life 6 12 months (commercially available lithium battery) Remote capabilities Long-term measurement Short-term measurement particularly suitable suitable NSTS 0617-E0313E 2 / 10 Subject to change without notice

Complete program for all requirements Narda offers a wide range of different isotropic probes. These include quad-band probes with inbuilt four isotropic sensors for separating mobile telephone services as well as wideband measurement from 100 khz to 40 GHz. Special probes are available for low frequency magnetic or electric fields from 10 Hz to 5 khz. This means that emissions from highvoltage cables and transformer stations can be recorded. Further, it is possible to combine up to two probes, e.g. an electric and a magnetic field probe in the so-called dual probe configuration. Electric field probe Magnetic field probe Dual probe configuration (without radome) Applications Narda Area Monitors Probes 100 khz to 3 GHz 100 khz to 7 GHz 300 khz To 18 GHz 300 khz To 40 GHz Field type E E E E E 10 Hz to 5 khz 0.1-3000 MHz, 0.1-862 MHz, 933-3000 MHz E (3 isotropic sensors) 0.1-3000 MHz, GSM, UMTS (contact us) E (4 isotropic sensors) 0.1-7000 MHz, GSM, UMTS (contact us) E (4 isotropic sensors) Band type Wide Wide Wide Wide Single Tri Quad Quad Single Probe designation EP-1B-01 EP-1B-03 EP-1B-05 EP-1B-06 EP-1B-04 EP-3B-01 EP-4B-01 EP-4B-02 Mobile communications Radio / TV broadcasting Directional radio Satellite communication Radar Industry Railroads Power lines Transformers 10 Hz to 5 khz H particulary suitable suitable Simultaneous monitoring of electric and magnetic fields Possible dual-probe configuration: Probe combination / field type + EP-1B-04 + EP-1B-01 + EP-1B-03 + EP-1B-05 + EP-1B-06 H 10 Hz to 5 khz 10 Hz to 5 khz 10 Hz to 5 khz 10 Hz to 5 khz 10 Hz to 5 khz E 10 Hz to 5 khz 100 khz to 3 GHz 100 khz to 7 GHz 300 khz to 18 GHz 300 khz to 40 GHz NSTS 0617-E0313E 3 / 10 Subject to change without notice

SPECIFICATIONS EP-1B-01 Electric Field Probe* Measurement range Overload Flatness @ 20 V/m Anisotropy @ 6 V/m H-Field rejection 100 khz to 3 GHz 0.2 V/m - 200 V/m (dynamic range > 60 db) 600 V/m 1 200 MHz ± 0.8 db; 150 khz - 3 GHz ± 1.5 db ± 0.5 db (0.5 to 100 V/m) ± 0.8 db @ 50 MHz (typical 0.6 db) 0.1 db/ C 450 mm length, 55 mm Ø, 180 g EP-1B-03 Electric Field Probe* Measurement range Overload Flatness @ 20 V/m Anisotropy @ 6V/m 100 khz to 7 GHz 0.2 V/m - 200 V/m (dynamic range > 60 db) 600 V/m 3 MHz-200 MHz: ±0.8 db; 0.15 MHz-3 GHz: ±1.5 db ; 0.1 MHz-6 GHz: ±2 db ± 0.5 db (0.5 to 100 V/m) ± 0.8 db @ 50 MHz (typical 0.6 db) 0.1 db/ C 450 mm x 55 mm Ø, 180 g EP-1B-05 Electric Field Probe* Measurement range Overload Flatness @ 6 V/m Anisotropy @ 6V/m 300 khz to 18 GHz 0.5 V/m - 800 V/m (dynamic range > 64 db) 1200 V/m 1 MHz - 1 GHz: ±1.5 db; 1 GHz - 12 GHz: ±3 db; 12 GHz - 18 GHz: ±4 db ± 0.5 db (±0.3 typ.) (1.2 V/m to 200 V/m) @ 200 MHz ± 0.8 db @ 200 MHz (typical 0.5 db @ 930 and 1800 MHz) 0.02 db/ C 450 mm x 55 mm Ø, 200 g EP-1B-06 Electric Field Probe* Measurement range Overload Flatness @ 6 V/m Anisotropy @ 6V/m 300 khz to 40 GHz 0.5 V/m - 800 V/m (dynamic range > 64 db) 1200 V/m 1 MHz - 1 GHz: ±1.5 db; 1 GHz - 12 GHz: ±3 db; 12 GHz - 23 GHz: ±4 db; 23 GHz - 40 GHz ±5 db ± 0.5 db (±0.3 typ.) (1.2 V/m to 200 V/m) @200 MHz ± 0.8 db @ 200 MHz (typical 0.5 db @ 930 and 1800 MHz) 0.02 db/ C 450 mm x 55 mm Ø, 200 g NSTS 0617-E0313E 4 / 10 Subject to change without notice

EP-1B-04 Electric Field Probe* Measurement range and overload Flatness @ 100 V/m (40 Hz 1 khz) Anisotropy 10 Hz to 5 khz 5 V/m - 20 kv/m (dynamic range > 72 db); overload: > 30 kv/m 0.1 V/m 1 db (typical 0.5 db) 0.5 db @ 50 Hz, 100 V/m 77 mm x 53 mm Ø, 110 g EP-3B-01 Tri-Band Electric Field Probe* Wideband: 0.1 to 3000 MHz Low pass: 0.1 to 862 MHz High pass: 933 to 3000 MHz Sensors Measurement range Overload Flatness @ 20 V/m Three inbuilt single isotropic sensors for each frequency range (no calculation) 1-200 MHz ± 0.8 db 150 khz-3 GHz ±1.5 db 0.2-200 V/m (dynamic range > 60 db) 600 V/m 1-200 MHz±0.8 db 150 khz-862 MHz±1.5 db ± 0.5 db (0.5 to 100 V/m) 933-3000 MHz ± 1.5dB Anisotropy @ 6 V/m ± 0.8 db @ 50 MHz (typical 0.6 db) ±0.8dB @1 GHz(typical 0.6 db) Out of band attenuation Not applicable 933 MHz-3 GHz > 23 db (ref. to 50 MHz) 0.1 db/ C 450 mm x 55 mm Ø, 180 g 0.1 862 MHz > 23 db (ref. to 1 GHz) EP-4B-01 Quad-Band Electric Field Probe* Wideband 0.1 to 3000 MHz Sensors 900 Band 925 to 960 MHz 1800 Band 1805 to 1880 MHz Four inbuilt single isotropic sensors for each frequency range (no calculation) Meas. range 0.2 to 200 V/m 0.03 to 30 V/m Meas. resolution CW damage level Flatness @ 6 V/m 1-200 MHz ± 0.8 db 150 khz-3 GHz ± 1.5 db 925-960 MHz +0.5/-2.5 db 300V/m 1805 1880 MHz +0.5/-2.5 db ± 0.5 db (0.5 to 100 V/m) ± 0.5 db (0.06 to 20 V/m) Anisotropy Out of band attenuation Centre frequency drift ± 0.8 db @ 50 MHz, Not applicable Not applicable ± 0.8 db@ 942.5 MHz, to 1842 MHz(GSM): 25 db to 2140 MHz(UMTS):25 db ± 0.8 db@ 1842.5 MHz, to 942 MHz(GSM): 15 db to 2140 MHz(UMTS): 13 db 40 C 50 C = ± 100kHz -20 C 40 C = ± 100 khz/ C 0 C 50 C = ± 0.3 db; -20 C 0 C = -0.1 db/ C 450 mm x 55 mm Ø, 210 g 2100 Band 2110 to 2170 MHz 2110 2170 MHz +0.5/-2.5 db ± 0.8 db@ 2140 MHz, to 942 MHz(GSM): 17dB to 1842 MHz(GSM): 10 db NSTS 0617-E0313E 5 / 10 Subject to change without notice

EP-4B-02 Quad-Band Electric Field Probe* Wideband 0.1-7000 MHz Sensors 900 Band 925-960 MHz 1800 Band 1805-1880 MHz Four inbuilt single isotropic sensors for each frequency range (no calculation) Meas. range 0.2-200 V/m 0.03-30 V/m Meas. resolution CW damage level Dynamic range 300 V/m >60 db 2100 Band 2110-2170 MHz Flatness @ 6 V/m 3-200 MHz ± 1.5 db 150 khz-3 GHz ± 2 db 0.1 MHz 7 GHz ± 3 db 925-960 MHz +0.5 / -2.5 db 1805-1880 MHz +0.5 / -2.5 db 2110-2170 MHz +0.5 / -2.5 db ± 0.5 db (0.5 to 100 V/m) ± 0.5 db (0.1 to 20 V/m) Anisotropy ± 0.8 db@ 50 MHz, ± 0.8 db@ 942.5 MHz, ± 0.8 db@ 1842.5 MHz, ± 0.8 db@ 2140 MHz, Out of band attenuation Not applicable to 1842 MHz(GSM): 25 db to 2140 MHz(UMTS):25dB to 942 MHz(GSM): 15 db to 2140 MHz(UMTS):13dB to 942 MHz(GSM): 17dB to 1842 MHz(GSM):10 db Centre frequency drift Not applicable 40 C 60 C = ± 100 khz -20 C 40 C = - 100 khz / C 0 C 50 C = ± 0.3 db; -20 C 0 C = -0.1 db/ C 450 mm x 55 mm Ø, 210 g Magnetic Field Probe* 10 Hz to 5 khz Measurement range and overload 50 nt - 200 μt (dynamic range >72 db); overload: > 1 mt 1 nt Flatness 40 Hz 1 khz, 1 db (typical 0.6 db) ± 0.5 db (200nT to 100µT) Anisotropy 0.3 db @ 50 Hz, 3 µt E field rejection 83 mm x 53 mm Ø, 110 g (*) All probes include on board A/D conversion, calibration factors on E 2 PROM, and temperature sensor NSTS 0617-E0313E 6 / 10 Subject to change without notice

AMB-8059 Multi-band EMF Area Monitor Technical Specifications Dynamic range Resolution Sensitivity Accuracy Measurement Units Field measured Sampling rate Measurement / acquisition functions Internal memory Max data storage capacity (before overwriting old data) Data download Depending on probe (see probe specifications) Depending on probe (see probe specifications) Depending on probe (see probe specifications) Depending on probe (see probe specifications) Depending on probe (see probe specifications) V/m, kv/m, nt, µt, mt. The unit shown depends on the probe connected Total field, average and Peak (MAX) 1 measurement every 1 second From 30 s to 15 min About 512 MB 6 Month depending on measurement resolution up to 2184 days Manual (1), (3) Automatic managed by the unit at predefined timings (2), (3) Automatic by PC Automatic creation of a.txt and.bmp file after download Functions Field strength alarm Clock AVG, RMS, maximum peak; daily report via SMS (3) Display and marking of data acquired during modem transmission (3) Two programmable field strength thresholds (warning and alarm) with automatic notice both of exceeding the limit and returning within the limits (3) Real time internal clock Messages Reports and alarms via SMS up to 10 mobile phones simultaneously (3) Sensor Battery management Temperature management Humidity management GPS coordinates Display of model and calibration date Every record includes Battery Voltage and Charge Current value Every record includes internal Temperature value Every record includes internal Humidity value Programmable record NSTS 0617-E0313E 7 / 10 Subject to change without notice

AMB-8059 Multi-band EMF Area Monitor General Specifications Internal 2G modem Bands (850/900/1800/1900 MHz) (3) Internal 3G modem Bands (800/850/900/1900/2100 MHz) (3) Wi-Fi Field probes Wi Fi 802.11 b/g Interchangeable, several models available, single and dual probe operation (e.g. E+H field) Interfaces RS232, USB, Ethernet, Wi-Fi, optical (6), Micro SD Card; 2G/ 3G modem (3) Protection Other alarms Internal battery Consumption External power Operating time Recharging time Open case sensor Open case, internal overheat, internal humidity, low battery, battery overload (model AMB- 8059/01 and AMB-8059/03 only), probe malfunction, field over limit. AMB-8059/00 - AMB-8059/02: Non rechargeable primary battery, lithium SAFT LSH20, 3.6 V, 13 A/h AMB-8059/01 - AMB-8059/03: Lead, 4V, 2.5 A/h, rechargeable 1 ma when 2G/3G module and Wi-Fi module off 300 ma max when 2G module is transmitting and Wi-Fi module off (3) 500 ma max when 3G module is transmitting and Wi-Fi module off (3) 120 ma max when Wi-Fi module is transmitting and 2G/3G off (3) 6 ma optical link data query every 1 s; Wi-Fi and 2G/3G off. DC, 5 V, 1 A max (AMB-8059/01 and AMB-8059/03 only) AMB-8059/02: about 8 months @ 1min GSM module transmission per day and single probe (4), (5) operating mode (autonomy depends on probe and setting) AMB-8059/03: > 80 days in total darkness @ 1min GSM module transmission per day and single (4), (5) probe operating mode (autonomy depends on probe and setting) For best performance, install solar panels in direct sunlight. 24 hours with external power unit (AMB-8059/01 and AMB-8059/03 only) Auto test Test of all possible alarm Compliance European directives 89/336 and 73/23, CEI 211-6, CEI 211-7, ITU-T K.83 Operating temperature -20 C / +55 C Humidity 93 % non-condensing Dimensions (WxDxH) 112 x 112 x 730 mm AMB-8059/00 and AMB-8059/02: 1.2 kg (unit only); 6.5 kg (total weight including supports and Weight base) AMB-8059/01 and AMB-8059/03: 2.4 kg (unit only); 7.7 kg (total weight including supports and base) Environmental protection IP55 Country of origin Italy Notes: (1): To the controller PC or to the user s FTP server depending on the preferred communication mode. (2): Directly from the station or from the user s FTP server depending on the preferred communication mode. (3): AMB-8059/02 and AMB-8059/03 only are equipped with a 2G and 3G modem. (4): AMB-8059/00 and AMB-8059/01 power autonomy is longer as they are not equipped with a 2G and 3G modem. (5): Specifications depending on battery age, ambient temperature and 2G/3G field coverage. (6): Optical only link only for the AMB-8059/03, AMB-8059/01 and AMB-8059-00 NSTS 0617-E0313E 8 / 10 Subject to change without notice

AMB-8059 PC control software Main Functions and Requirements Main functions PC minimum requirements Local and remote communication for AMB-8059 setup and data downloading Data display/analysis in graphical and table format Vertical and horizontal zoom, linear and logarithmic graphs, marker Data export Operating system: Windows XP, Vista, Windows 7, Windows 10 Minimum display resolution: 1024x768 Internet connection for FTP remote communication mode (ports 20 and 21 for FTP data communication must be open) Line or GSM modem for CSD (Circuit Switched Data) remote communication mode AMB-8059 web based software available EMF observatory (option for more information contact us) Main Functions Field strength over time including national limits. Interval individually adjustable. 24 h field strength distribution. Field strength in table format including comparison and national limits. Installed EMF monitors selectable via web mapping. NSTS 0617-E0313E 9 / 10 Subject to change without notice

ORDERING INFORMATION AMB-8059 Remote stations Area Monitor station powered by internal primary Li-Ion battery Area Monitor station powered by solar panel and back-up battery Area Monitor remote station with 2G and 3G internal modem, powered by internal primary Li-Ion battery Area Monitor remote station with 2G and 3G internal modem, powered by solar panel and back up battery Field probes Electric field probe 0.1 to 3000 MHz; 0.2 to 200 V/m Electric field probe 0.1 to 7000 MHz; 0.2 to 200 V/m Electric field probe 300 khz to 18 GHz; 0.5 to 800 V/m Electric field probe 300 khz to 40 GHz; 0.5 to 800 V/m Electric field probe 10 Hz to 5 khz; 5 V/m to 20 kv/m Tri-band electric field probe 0.1 to 3000 MHz / 0.1 to 862 MHz / 933 to 3000 MHz; 0.2 to 200 V/m Quad-band electric field probe 0.1 to 3000 MHz; 0.2 to 200 V/m / 925 to 960 MHz / 1805 to 1880 MHz / 2110 to 2170 MHz, 0.03 to 30 V/m Quad-band electric field probe 0.1 to 7000 MHz; 0.2 to 200 V/m / 925 to 960 MHz / 1805 to 1880 MHz / 2110 to 2170 MHz, 0.03 to 30 V/m Magnetic field probe 10 Hz to 5 khz; 50 nt to 200 μt Optional accessories Metallic T-shaped base and Fiberglass mast (includes kit of screws, ties and 3 ballast bags) Cover extension for AMB-8059 dual probe configuration AMB-8059/00 AMB-8059/01 AMB-8059/02 AMB-8059/03 EP-1B-01 EP-1B-03 EP-1B-05 EP-1B-06 EP-1B-04 EP-3B-01 EP-4B-01 EP-4B-02 AMB-8059-MAST 8059-CE O/E optical converter USB 650.000.176 Cable, FO Duplex RP-02 with cable clamp, 10 m (only models 8059/03 and 8059/01 with optical link) 650.000.289 Cable, FO Duplex RP-02 with cable clamp, 20 m (only models 8059/03 and 8059/01 with optical link) 650.000.290 Cable, FO Duplex RP-02 with cable clamp, 40 m (only models 8059/03 and 8059/01 with optical link) 650.000.291 Cable, FO Duplex RP-02, 10 m (only model 8059/00 with optical link) 650.000.196 Cable, FO Duplex RP-02, 20 m (only model 8059/00 with optical link) 650.000.257 Cable, FO Duplex RP-02, 40 m (only model 8059/00 with optical link) 650.000.275 Included in delivery Primary Li-ion battery (AMB-8059/00 and AMB-8059/02 only) Power supply / Battery Charger (AMB-8059/01 and AMB-8059/03 only) Assembled Solar Unit (AMB-8059/01 and AMB-8059/03 only) Ethernet cable (AMB-8059/01 and AMB-8059/03 only) USB cable, 1.8 m, USB(A)/USB(B) (AMB-8059/01/02/03 only) 10 m optical cable and O/E converter USB (AMB-8059/00 only ) Swivel joint for installation on AMB-8059-MAST Operating Manual, Test & Calibration Certificates AMB-8059-SW02 PC Software Narda Safety Test Solutions GmbH Sandwiesenstrasse 7 72793 Pfullingen, Germany Phone: +49 7121 9732-0 Fax: +49 7121 9732-790 support.narda-de@l3t.com www.narda-sts.com Narda Safety Test Solutions 435 Moreland Road Hauppauge, NY 11788, USA Phone: +1 631 231-1700 Fax: +1 631 231-1711 NardaSTS@L3T.com www.narda-sts.us Narda Safety Test Solutions Srl Via Leonardo da Vinci, 21/23 20090 Segrate (Milano) - Italy Phone: +39 02 26 998 71 Fax: +39 02 26 998 700 nardait.support@l3t.com www.narda-sts.it Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communucations Holding Inc. Trade names are trademarks of the owners. NSTS 0617-E0313E 10 / 10 Subject to change without notice