Three-phase monitoring relay CM-PVE

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Three-phase monitoring relays CM-PFE and CM-PFE.2

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Three-phase monitoring relays

Type CP-S, CP-C & CP-A Switch mode

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay

Three-phase monitoring relay CM-PBE

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relay

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFS

Three-phase monitoring relays CM-PVS.81

Liquid level monitors and controls

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Liquid level monitoring relay CM-ENS.2x

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Three-phase monitoring relays Product group picture

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Electronic timer CT-SDD.22

Electronic timer CT-TGD.22

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relays Product group picture

Electronic timer CT-MFS.21

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Three-phase monitoring relays Table of contents

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Control module CP-A CM

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Protection components

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

CP-T range Product group picture

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Analog signal converters CC range

CP-E range Benefits and advantages

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic measuring and monitoring relays CM-range

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-E 24/0.75

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-E 24/20.0

CP-T range Benefits and advantages

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Electronic timer CT-SDE

48 Series - Relay interface modules A. Features

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

38 Series - Relay interface modules A

Control module CP-A CM

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-D 12/2.1

Power supply CP-E 24/2.5

38 Series - Relay interface modules A

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Power supply CP-D 24/1.3

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timers CT-S range Selection and ordering details

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Primary switch mode power supplies Product group picture

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/10.0 Primary switch mode power supply

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 24/40.0 Primary switch mode power supply

Transcription:

Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... / 73 Approvals and marks... / 6 Technical diagrams... /0 Dimensional drawings... /03 Accessories... /04 /67 CDC0004C007

CM-MSE, CM-MSS, CM-MSN Benefits and advantages, Selection table Operating principle and fields of application for thermistor motor protection relays The CM range of thermistor motor protection relays are used to control motors equipped with PTC temperature sensors. The PTC temperature sensors are incorporated in the motor windings to measure the motor heating. This enables direct control and evaluation of the following operating conditions: heavy duty starting increased switching frequency single-phase operation high ambient temperature insufficient cooling break operation unbalance Further applications: Temperature monitoring of equipment with PTC sensors integrated, such as machine rolling bearings, hot-air ventilators, oil, air, heating installations, etc. Resistance characteristic for one single temperature sensor acc. to DIN 44 08. The relay is independent of the rated motor current, the insulation class and the method of starting. The PTC sensors are connected in series to the terminals T a and T b (or T a and T bx without short-circuit detection). The number of possible PTC sensors per measuring circuit is limited by the sum of the individual PTC sensor resistances: R G = R + R + R N.5 k. Under normal operating conditions the resistance is below the response threshold. If only one of the PTC resistors heats up excessively, the output relay de-energizes. If the autoreset function is configured, the output relay energizes automatically after cooling down. Devices with manual (pushbutton on front-side) or remote reset configuration have to be controlled via the control input by the required signal. SVC 0 000 F039 NAT = Nominal response temperature Selection table thermistor motor protection relays CM-MSE CM-MSS () CM-MSS () CM-MSS (3) CM-MSS (4) CM-MSS (5) CM-MSS (6) CM-MSS (7) CM-MSN Function Measuring range Number of sensor circuits 3 6 Wire break monitoring Short-circuit detection Non-volatile fault storage ) ) ) ) ) Operation/Reset Auto reset ) ) ) ) ) Manual reset Remote reset Test button Output contacts Operational principle closed-circuit principle Number / type Width of enclosure ) configurable via terminals ) Auto reset without non-volatile fault storage configurable by permanent jumpering of connecting terminals S-T or S/X-S/X /68 CDC0004C007 c/o n/o c/o c/o n/o + n/c c/o c/o per sensor circuit n/o + n/c accumulative evaluation n/o + n/c accumulative evaluation.5 mm 45 mm Supply voltages and order codes 4 V AC SVR550805R9300 SVR4308R9300 4 V AC/DC SVR430800R900 SVR43080R9300 SVR43070R9300 0-30 V AC SVR550800R9300 SVR4308R0300 SVR4307R0300 0-40 V AC SVR55080R9300 SVR43080R00 SVR4308R300 SVR4307R300 380-440 V AC SVR4307R300 4-40 V AC/DC SVR43070R0400 SVR43070R0300 SVR43070R000 SVR43070R0500 SVR45005R000

CM-MSE, CM-MSS Ordering details CDC 5 0 F0b03 CM-MSE Auto reset Connection of several sensors (max. 6 sensors conn. in series) Monitoring of bimetals n/o contact Excellent cost / performance ratio A T T T A T A 3 4 3 4 A SVC 0 000 F040 A-A T-T Sensor circuit 3-4 Output contact - Closed-circuit principle piece piece SVC 0 000 F04 CM-MSE CM-MSE 4 V AC 0-30 V AC 0-40 V AC SVR 550 805 R9300 SVR 550 800 R9300 SVR 550 80 R9300 0. / 0.4 0. / 0.4 0. / 0.4 SVR 430 80 F00 CM-MSS (), c/o contact Auto reset Connection of several sensors Monitoring of bimetals c/o contact LEDs for status indication A T T T A T A 4 4 A SVC 0 000 F04 A-A T-T Sensor circuit -/4 Output contact - Closed-circuit principle SVC 0 000 F04 piece piece CM-MSS () CM-MSS () 4 V AC/DC ) 0-40 V AC SVR 430 800 R900 SVR 430 80 R00 0.5 / 0.33 0.5 / 0.33 SVR 430 8 F300 CM-MSS (), c/o contacts Fault storage can be switched off Auto reset configurable Reset button Remote reset Monitoring of bimetals c/o contacts LEDs for status indication A T X T T A T A 4 4 4 S 4 A SVC 0 000 F59 A-A T-T Sensor circuit S-T Remote reset X-T jumper = no storage -/4 Output contacts - -/4 Closed-circuit principle piece T T T S X L L L3 M ϑ ϑ ϑ 3 piece CDC 5 3 F0b07 CM-MSS () SVR 430 7 F300 CM-MSS () 4 V AC/DC ) 4 V AC 0-30 V AC 0-40 V AC SVR 430 80 R9300 SVR 430 8 R9300 SVR 430 8 R0300 SVR 430 8 R300 CM-MSS (3), c/o contacts, short-circuit monitoring confi gurable Fault storage can be switched off Auto reset configurable Reset button Remote reset Monitoring of bimetals Short-circuit monitoring of the sensor circuit configurable c/o contacts LEDs for status indication A Tx T T T A T A 4 4 S 4 4 A SVC 0 000 F043 A-A S-T remote reset jumper = without storage T-Tx measuring circuit without short-circuit monitoring T-T measuring circuit with short-circuit monitoring -/4 Output contacts -/4 Closed-circuit principle 0.5 / 0.33 0.5 / 0.33 0.5 / 0.33 0.5 / 0.33 SVC 0 000 F044 CM-MSS (3) piece piece F: red LED - fault tripping U: green LED - control Marker label Reset button CM-MSS (3) 4 V AC/DC ) 0-30 V AC 0-40 V AC 380-440 V AC SVR 430 70 R9300 SVR 430 7 R0300 SVR 430 7 R300 SVR 430 7 R300 0.5 / 0.33 0.5 / 0.33 0.5 / 0.33 0.5 / 0.33 ) not electrically isolated Accessories: PTC sensors... /7 Technical data.../73 Technical diagrams... /0 Dimensional drawings.../03 Accessories... /04 /69 CDC0004C007

CDC 5 077 F0t07 CM-MSS (4) CDC 5 047 F0t04 CM-MSS (5) Reset / test button F: red LED - fault tripping U: green LED - control Marker label SVR 430 70 F000 CM-MSS (6) Thermistor motor protection relays CM-MSS Ordering details CM-MSS (4) + CM-MSS (5), -channel Short-circuit monitoring of the sensor circuit Wide range: 4-40 V AC/DC Non-volatile fault storage selectable Reset and test button Remote reset Auto reset configurable Output contacts: n/c and n/o or c/o contacts LEDs for status indication CM-MSS (4) -channel n/c, n/o CM-MSS (5) -channel c/o CM-MSS (6), -channel, single evaluation Short-circuit monitoring for the sensor circuits Wide range: 4-40 V AC/DC separate sensor circuits for monitoring of two motors or one motor with sensor circuits (prewarning and final switch off) Reset button Auto reset configurable Output contacts: x c/o contact 3 LEDs for status indication CM-MSS (4) A T T S T A 3 T A 4 S 3 4 A CM-MSS (5) A S/X T T T A S/X S/X ϑ T A 4 4 S/X 4 4 A SVC 0 000 F 048 CDC 5 47 F0b06 CDC 5 06 F0004 A-A T-T Sensor circuit S-T Remote reset 3-4 Output contacts - - Closed-circuit principle A-A T-T Sensor circuit S/X-S/X Reset -/4 Output contacts - -/4 Closed-circuit principle S/X T T S/X piece jumper = no storage L L L3 piece 4-40 V AC/DC SVR 430 70 R0400 0.5 / 0.33 4-40 V AC/DC SVR 430 70 R0300 0.5 / 0.33 A-A -/4, Output contacts - -/4 Closed-circuit principle T-T Sensor circuit T-T S-T jumpered = no storage SVC 0 000 F045 CDC 5 044 F0004 SVC 0 000 F 046 Reset button to F-F: red LED - fault tripping to U: green LED - control Marker label piece piece CM-MSS (6) 4-40 V AC/DC SVR 430 70 R000 0.5 / 0.33 Accessories: PTC sensors... /7 Technical data.../73 Technical diagrams... /0 Dimensional drawings.../03 Accessories... /04 /70 CDC0004C007

CM-MSS, CM-MSN Ordering details CM-MSS (7), 3 sensor circuits, accumulative evaluation SVR 430 70 F0500 Short-circuit monitoring for the sensor circuits Wide range 4-40 V AC/DC Non-volatile fault storage configurable Remote reset Auto reset configurable Reset and test button Output contacts: n/c and n/o contact 4 LEDs for status indication SVC 0 000 F049 A-A 3-4 Output contacts - - Closed-circuit principle T-T Sensor circuits T-T 3T-T S-T Remote reset jumpered = no storage SVC 0 000 F047 CM-MSS (7) Reset / test button to F-F3: red LED - fault tripping to 3 U: green LED - control Marker label piece piece CM-MSS (7) 4-40 V AC/DC SVR 430 70 R0500 0.5 / 0.33 CM-MSN, 6 sensor circuits, accumulative evaluation SVR 450 05 F0400 Short-circuit monitoring of the sensor circuit Wide range: 4-40 V AC/DC Non-volatile fault storage configurable Remote reset Auto reset configurable Reset and test button Output contacts: n/c, n/o contact 7 LEDs for status indication SVC 0 000 F050 A-A 3-4 Output contacts - - Closed-circuit principle T...6T-T S-T Sensor circuits Remote reset, jumper = no storage SVC 0 000 F05 CM-MSN Reset / Test button to F-F6: red LED - fault tripping F to F6 U: green LED - control Marker label piece piece CM-MSN 4-40 V AC/DC SVR 450 05 R000 0.3 / 0.5 accumulative evaluation = if any input exeeds the threshold, the output relay will trip Accessories: PTC sensors... /7 Technical data.../73 Technical diagrams... /0 Dimensional drawings.../03 Accessories... /04 /7 CDC0004C007

Thermistor motor protection PTC temperature sensors C0 Ordering details, technical data RPTC [] 0 4 0 3 0 0 Temperature sensor characteristic -0 C TPTC [ C] TNF - 0 K TNF - 5 K TNF TNF + 5 K TNF + 5 K CDC 5 068 F008 The PTC temperature sensors (temperature-dependent with positive temperature coefficient) are selected by the manufacturer of the motor depending on: the motor insulation class according to IEC/EN 60034-, the special characteristics of the motor, such as the conductor cross-section of the windings, the permissible overload factor etc. special conditions prescribed by the user, such as the permissible ambient temperature, risks resulting from locked rotor, extent of permitted overload etc. One temperature sensor must be embedded in each phase winding. For instance, in case of three-phase squirrel cage motors, three sensors are embedded in the stator windings. For pole-changing motors with one winding (Dahlander connection), 3 sensors are also sufficient. Pole-changing motors with two windings, however, require 6 sensors. If an additional warning is required before the motor is switched off, separate sensors for a correspon dingly lower temperature must be embedded in the winding. They have to be connected to a second control unit. The sensors are suitable for embedding in motor windings with rated operating voltages of up to 600 V AC. Conductor length: 500 mm per sensor. A 4 V varistor can be connected in parallel to protect the sensors from overvoltage. Due to their characteristics, the thermistor motor protection relays can also be used with PTC temperature sensors of other manufacturers which comply with DIN 44 08 and DIN 44 08. Rated response Color coding Pack. temperature T NF unit set set piece Temperature sensor C0, standard version acc. to DIN 4408 set = 3 SVC 0 000 F053 C0-70 C0-80 C0-90 C0-00 C0-0 C0-0 C0-30 C0-40 C0-50 C0-60 C0-70 70 C 80 C 90 C 00 C 0 C 0 C 30 C 40 C 50 C 60 C 70 C white-brown white-white green-green red-red brown-brown gray-gray blue-blue white-blue black-black blue-red white-green GHC 0 0003 R000 GHC 0 0003 R000 GHC 0 0003 R0003 GHC 0 0003 R0004 GHC 0 0003 R0005 GHC 0 0003 R0006 GHC 0 0003 R0007 GHC 0 0003 R00 GHC 0 0003 R0008 GHC 0 0003 R0009 GHC 0 0003 R000 Rated response Color coding Pack. temperature T NF unit piece piece Triple temperature sensor C0-3 C0-3-50 50 C black-black GHC 0 0033 R0008 0.05/0. Technical data Characteristic data Sensor type C0 Cold-state resistance 50-00 at 5 C Warm-state resistance ± 5 up to 6 K of rated response temperature T NF 0 000 Thermal time constant, sensor open ) < 5 s Permitted ambient temperature +80 C ) ) Not embedded in windings. For triple temperature sensor take values x 3. /7 CDC0004C007 Rated response temperature tolerance T NF T NF 70 5 C 80 5 C 90 5 C 00 5 C 0 5 C 0 5 C 30 5 C 40 5 C 50 5 C 60 5 C PTC resistance R from -0 C to T NF - 0 K 00 PTC resistance R at PTC temperatures of: T NF - T NF (U PTC.5 V) T NF + T NF (U PTC.5 V) T NF + 5 K (U PTC 7.5 V) 570 570-550 330 4000 70 7 C 570 570 -

CM-MSE, CM-MSS, CM-MSN Technical data CM-MSE CM-MSS CM-MSN Input circuit U S - A-A 4 V AC approx..5 VA power consumption A-A 4 V AC/DC approx.. VA / 0.6 W A-A 0-30 V AC approx..5 VA A-A 0-40 V AC approx..5 VA A-A 380-440 V AC approx..7 VA A-A 4-40 V AC/DC approx..4-.7 W / approx. 3.5-5.7 VA U S tolerance -5 %... +0 % Rated frequency AC: 50-60 Hz / 4-40 V AC/DC versions: 5-400 Hz Duty time 00 % Measuring circuit T-T T-T/Tx, T...6T-T T...6T-T Monitoring function temperature monitoring by means of PTC sensors Number of senor circuits, oder 3 (see order. details) 6 Short-circuit monitoring - see ordering details yes Non-volatile fault storage - see ordering details configurable Test function - see ordering details yes Sensor circuit Temperature threshold (relay de-energizes).7-3.7 k CM-MSS (+): 3050550 3.6 k 5 % CM-MSS (3-7): 3.6 k 5 % Temperature hysteresis (relay energizes).7-.3 k CM-MSS (+): 900400.6 k 5 % CM-MSS (3-7):.6 k 5 % Short circuit threshold (relay de-energizes) <0 Short circuit hysteresis (relay energizes) >40 Maximum total resistance of sensors connected in series (cold state).5 k Maximum sensor cable length for short-circuit detection x 00 m at 0.75 mm, x 400 m at.5 mm Response time <00 ms Control circuit for storage and hysteresis function Remote reset S-T or S/X-S/X - n/o contact Maximum no-load voltage - approx. 5 V, 4-40 V; AC/DC versions: 5.5 V Maximum cable length - 50 m, 00-00 m if shielded Indication of operational states Control U: green LED - V: control applied Fault indication F: red LED - V: output relay de-energized Output circuits 3-4 -/4, -/4, 3-4, - 3-4, - Kind of output n/o contact CM-MSS (): c/o contact CM-MSS (,3,5): c/o contacts CM-MSS (4, 7): n/o + n/c CM-MSS (6): x c/o contact n/o + n/c contact Operational principle closed-circuit principle (output relay de-energizes if the measured value exceeds/drops below the adjusted threshold) Contact ma terial AgCdO CM-MSS (++6): AgCdO CM-MSS (3+4+5+7): AgNi AgNi Rated voltage (VDE 00, IEC 664-, IEC 60947-) 50 V Maximum switching voltage 50 V Rated operational current I e AC (resistive) 30 V 4 A (IEC/EN 60947-5-) AC5 (inductive) 30 V 3 A DC (resistive) 4 V 4 A DC3 (inductive) 4 V A (.5 A - n/c contact ) ) AC rating Utilization category (UL 508) (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 VA Mechanical lifetime 30 (0 ) ) x 0 6 switching cycles Electrical lifetime (AC, 30 V, 4 A) 0. x 0 6 switching cycles Max. fuse rating to achieve n/c contact 0 A fast-acting 4 A (0 A ) ) fast-acting 0 A fast-acting short circuit protection n/o contact 0 A fast-acting 6 A (0 A ) ) fast-acting 0 A fast-acting General data Dimensions (W x H X D).5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in).5 x 78 x 00 mm (0.89 x 3.07 x 3.94 in) 45 x 78 x 00 mm (.77 x 3.07 x 3.94 in) approx. 0. kg (0.4 lb) approx. 0.5 kg (0.33 lb) approx. 0.3 kg (0.5 lb) Mounting position any Degree of protection enclosure / terminals IP50 / IP0 Ambient temperature range operation -0...+60 C -5...+65 C storage -40...+85 C Mounting DIN rail (IEC/EN 6075) ) SVR 430 70 R 000, SVR 430 8xx R xxxx /73 CDC0004C007

CM-MSE, CM-MSS, CM-MSN Technical data CM-MSE CM-MSS CM-MSN Electrical connection Wire size fine strand with wire end ferrule x.5 mm ( x 6 AWG) x.5 mm ( x 4 AWG) fine strand without wire end ferrule x 0.75-.5 mm ( x 8-6 AWG) x 0.75-.5 mm ( x 8-4 AWG) rigid x -.5 mm ( x 8-6 AWG) x 0.75-.5 mm ( x 8-4 AWG) Stripping length x 0.75-.5 mm ( x 8-6 AWG) x 0.5-4 mm ( x 0- AWG) Tightening torque 0 mm (0.39 inch) 7 mm (0.8 inch) Standards Product standard IEC 55-6, EN 6055-6 Low Voltage Directive 006/95/EC EMC Directive 004/08/EC, 9/63/EEC, 9/3/EEC, 93/68/EEC, 93/67/EEC Electromagnetic compatibility EN 6000-6-, EN 6000-6-4 electrostatic discharge IEC/EN 6000-4- Level 3 (6 kv / 8 kv) radiated, radio-frequency, electromagnetic field IEC/EN 6000-4-3 Level 3 (0 V/m) electrical fast transient / burst IEC/EN 6000-4-4 Level 3 ( kv / 5 khz) surge IEC/EN 6000-4-5 Level 3/4 (/ kv) conducted disturbances, induced by radio-frequency fields IEC/EN 6000-4-6 Level 3 (0 V) Operational reliability (IEC 68--6) 6 g 4 g 5 g Resistance to vibration (IEC 68--6) 0 g 6 g 0 g Environmental testing (IEC 68--30 ) 4 h cycle time, 55 C, 93 % rel., 96 h Isolation data Rated voltage between supply, measuring and output circuit 50 V Rated impulse withstand voltage between all isolated circuits 4 kv /. - 50 μs Test voltage between all isolated circuits.5 kv, 50 Hz, min. Pollution degree 3 Overvoltage category III Approvals... /6 /74 CDC0004C007