Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

Similar documents
Proline Promass 83, 84

Power supply. Calibration. Surface finishing. Seal. Process connection

PROline promag 53 Division 1

Safety Instructions Proline Promass 300

Safety Instructions Proline Promag 500

Safety Instructions Proline Promass 100

CNGmass DCI. Technical Information. Coriolis mass flow measuring system For fueling with compressed natural gas (CNG)

Technical Information CNGmass DCI

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Proline Promass 80/83 H, I

INSTRUCTION MANUAL (ATEX / IECEx)

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Installation guide 971 SmartRadar LTi

Brief Operating Instructions Proline Promag 50

Proline Promass 80H, 83H

DPharp Differential Pressure and Pressure Transmitters

Safety Instructions Nivotester FTC625, FTC325

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

ATEX Installation Drawings and Instructions

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Technical Information Proline Promass 80F, 83F

Technical Information Proline Promass 80E, 83E

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Installation guide 877 FDI Field Display & Interface

Technical Information Cubemass DCI

Proline Promass 80I, 83I

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Technical Information Proline Promass 84F

Attachment to Certificate IECEx PTB X

Installation guide 854 XTG Level Gauge

ProcessMaster, HygienicMaster FEX300, FEX500

Proline Prosonic Flow 93P

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

ProcessMaster / HygienicMaster

Safety Instructions Micropilot NMR81, NMR84

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Proline Promass 80H, 83H

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Proline t-mass 65F, 65I

Proline Promass 80I, 83I

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10

TMU. Coriolis Mass Flow Meter. for liquids and gas

Proline Promass 84F. Technical Information

Coriolis Massflowmeter

OPTIWAVE 7300 C Supplementary instructions

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Coriolis Mass Flow Measuring System PROline promass 80/83 E

Design and applications

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Installation guide 970 SmartRadar ATi

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

INSTALLATION AND OPERATION MANUAL

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Proline Promass 83E. Coriolis Mass Flowmeter. Specifications. The Most Trusted Name In Measurement. Issue/Rev. 0.0 (8/11) Bulletin SS0M029

Installation guide 970, 971 and 973 series SmartRadar

Proline Promass 80E, 83E

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Proline Promass 80S, 83S

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

LF Conductivity Measuring Probe

Technical Information Proline Promag 53E

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

For use in Flammable Gas and Dust Atmospheres

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Coriolis Mass Flow Meter Model TM

Installation & Operating Manual. iwap202

SET Installation and Operating Instructions. Level switch for two sensors

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Proline Promass 80A, 83A

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

KFS. Flap-type flow meter. Design and range of application

FLEX Ex Power Supplies

Condumax W CLS15 and CLS15D

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

Technical Data. General specifications. Rated operating distance s n 3 mm

Coriolis Massflowmeter

IECEx Certificate of Conformity Annexe

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Technical Information Proline Promass 83X

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Temperature Input Module for Zone 1 Series 9482/32

Analog Universal Module HART for Zone 2 Series 9468/33

Certificate of Compliance

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

RMA42. Technical Information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Transcription:

Safety Instructions Proline Promass 40 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00061D, Proline Promass 40 HART Contents General warnings....................................................................... 2 Special conditions....................................................................... 2 Installation instructions................................................................... 2 COC Certificates of Conformity............................................................. 3 Description of measuring system............................................................ 3 Nameplates............................................................................ 4 Type code............................................................................. 5 Temperature table compact version.......................................................... 6 Gas and dust explosion protection........................................................... 6 Design of measuring system............................................................... 7 Cable entries........................................................................... 7 Cable specification...................................................................... 7 Potential equalization.................................................................... 7 Electrical connections.................................................................... 7 Terminal assignment and connection data, power supply.......................................... 8 Terminal assignment and connection data for signal circuits (intrinsically safe circuits).................... 8 Terminal assignment and connection data for signal circuits (non-intrinsically safe circuits)................ 9 Service adapter......................................................................... 9 Device fuse............................................................................ 9 Technical data........................................................................ 10 XA00120D/06/EN/14.17 71359

XA00120D Proline Promass 40 General warnings For installation, use and maintenance of the flow meter, the instruction manual and the following standards shall be observed: GB50257-2014 "Code for construction and acceptance of electric device for explosive atmospheres and fire hazard electrical equipment installation engineering" GB3836.13-2013 "Explosive atmospheres Part 13: Equipment repair, overhaul and reclamation" GB3836.15-2000 "Electrical apparatus for explosive gas atmospheres Part 15: Electrical installations in hazardous area (other than mines)" GB3836.16-2006 "Electrical apparatus for explosive gas atmospheres Part 16: Inspection and maintenance of electrical installation (other than mines)" GB15577-2007: Safety regulations for dust explosion prevention and protection" (Only if installed in dust hazardous areas.) GB12476.2-2010 "Electrical apparatus for use in the presence of combustible dust Part 2: Selection and installation". (Only if installed in dust hazardous areas.) Any maintenance shall be done after power off or the area known to be non-hazardous. The flow meter shall not be modified in order to ensure the explosion protection performance of the equipment. Any change may impair safety. Installation, connection to the electricity supply, commissioning and maintenance of the devices must be carried out by qualified specialists trained to work on Ex-rated devices. Compliance with all of the technical data of the device (see nameplate) is mandatory. Open the device only when it is de-energized (and after a delay of at least 10 minutes following shutdown of the power supply) or in non-hazardous (classified) locations. It is not permissible to connect the service adapter whilst the atmosphere is considered to be explosive. Opening the transmitter housing is only permitted for a brief time. During this time, ensure that no dust or water enters the housing. To guarantee resistance to dust and water the transmitter housing and the cable entries must be tightly sealed. Use of the devices is restricted to mediums against which the process-wetted materials are adequately resistant. The suitability of the device in the event of simultaneous occurrence of gas-air and dust-air mixtures requires an additional assessment. Special conditions The device must be integrated into the potential equalization system. Potential must be equalized along the intrinsically safe sensor circuits. Further information is provided in the "Potential equalization" section: ä 7. Installation instructions For terminals No. 20 to No. 27 of the transmitter, only devices with ratings U m 260 V and I m 500 ma are allowed to be connected (does not apply to intrinsically safe circuits). The measuring device must only be used in the permitted temperature class. The values of the individual temperature classes can be found in the temperature tables: ä 6. The following applies when using the terminal compartment in type of protection "flameproof/ex d": Only cable entries and cable glands, which are approved by NEPSI in accordance with GB3836.1-2010 and GB3836.2-2010 and which are suitable for an operating temperature of up to 80 C, they shall be used. The following applies when using the terminal compartment in type of protection "increased safety/ex e": Only cable entries, cable glands and blanking plugs, which are approved by NEPSI in accordance with GB3836.1-2010 and GB3836.3-2010 and which are suitable for an operating temperature of up to 80 C and for an ingress protection of IP 67, they shall be used. Alternatively Ex e cable glands specified or provided by Endress+Hauser Flowtec AG can be used. The cables must be installed in such a way, that they are fixed in place in order to ensure adequate strain relief. Suitable cables and suitable, certified cable glands, cable entries and blanking plugs must be used for measuring devices operated at temperatures below 20 C. The cable entries and openings not used must be sealed tight with suitable components. If the active intrinsically safe communication circuits (input/output option S, T; terminals 24/25 resp. 24/25) are fed into areas that require 1D or 2D apparatus, the connected apparatus must be tested and certified accordingly. In Zone 0, potentially explosive vapor/air mixtures may only occur under atmospheric conditions. If no potentially explosive mixtures are present, or if additional protective measures have been taken, the devices may be operated under other atmospheric conditions in accordance with the manufacturer's specifications. 2 Endress + Hauser

sous pas Proline Promass 40 XA00120D Installation instructions (continued) Turning the local display: the screw cap has to be removed before the local display can be turned, and this must be done with the device de-energized (and after a delay of at least 10 minutes following shutdown of the power supply). Turning the transmitter housing 1. Unscrew the grub screw. 2. Rotate the transmitter housing cautiously clockwise until the end stop (end of the thread). 3. Rotate the transmitter housing counter-clockwise (max. 360 ) in the wanted position. 4. Tighten the grub screw again. 2 3 max. 360 Nicht unter Spannung öffnen 1 cover tight while Keep alive circuits are circuits are alive Keep tight while cover Nicht-eigensichere Stromkreise durch IP40-Abdeckung geschützt Non-intrinsically safe circuits Ip40 protected Boucles de courant sans sécurité intrinsèque protégées par Ip40 4 tension ouvrir l appareil Ne Fig. 1: Turning the transmitter housing A0006944 COC Certificates of Conformity COC certificates of conformity By affixing the certification number the product conforms with the following standards: GB3836.1/2/3/4/20-2010 GB12476.1/5-2013, GB12476.4-2010 Certification numbers: GYJ16.1472X Inspection body NEPSI, National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation Description of measuring system The measuring system consists of a transmitter and sensor which together form a mechanical unit. Endress + Hauser 3

XA00120D Proline Promass 40 Nameplates The nameplates, which are mounted in a clearly visible position on the transmitter and sensor, contain all of the relevant information about the measuring system. 7 A 1 2 3 3a 4 6 5 4153 Reinach Switzerland PROMASS 40 Order Code: 40E25-XXXXXXXXXXXX Ser.No.: XXXXXXX2000 2016 Ext. ord. cd.: 40E25-XXXXXXXXXXXX+#**# 20-55VAC/16-62VDC 50-60Hz 15VA/W Um = 260VAC I-OUT (HART), f-out STATUS-OUT, STATUS-IN Ex d[ia] IIC T1~T6 Gb Ex td A21 IP6X T* GYJ16.1472X IP67 After de-energizing, wait 10 Minutes before opening! Nach dem Abschalten 10 Minuten warten vor dem Öffnen! Terminal 20... 27 Um = 260V Imax = 0.5mA 8 9 10 11 i XA00120D/06/../... -20 C (-4 F) <Tamb< +60 C (+ F) 12 N12895 13 14 15 16 B 1 2 3 3a 17 18 19 20 4153 Reinach Switzerland PROMASS E Order Code: 40E25-XXXXXXXXXXXX Ser.No.: XXXXXXX2000 2016 Ext. ord. cd.: 40E25-XXXXXXXXXXXX+#**# K-factor: 1.0000/0000 Size: DN25 / 1 DN25 DIN/EN PN40 / pnom = PS = 40bar Materals: TM: 1.4404 / 316L, 1.4539 / 904L -40 C... C/-40 F...+284 F Ex ia IIC T1~T6 Gb Ex td iad A21 IP6X T* GYJ16.1472X -20 C (-4 F)<Tamb<+60 C (+ F) i XA00120D/06/../... IP67 9 10 12 15 22 8 N12895 21 13 14 Fig. 2: Example for nameplates of a transmitter and of a sensor A Transmitter nameplate B Sensor nameplate A0008200 1 Production site 2 Transmitter or sensor type 3 Order code and serial number 3a Extended order code 4 Power supply, frequency and power consumption 5 Available inputs/outputs 6 Space for additional information on special products 7 Year of manufacture 8 Type of enclosure protection 9 Type of protection 10 Number of the NEPSI certificate of conformity 11 Space for notes, e.g. delays, etc. (only if necessary) 12 Ambient temperature range 13 C-Tick symbol 14 NEPSI symbol 15 Associated Ex documentation 16 Space for other approval specifications and certificates 17 Calibration factor/zero point 18 Nominal diameter/nominal pressure 19 Materials in contact with the medium 20 Fluid temperature range 21 Device nominal diameter 22 Direction of flow 4 Endress + Hauser

Proline Promass 40 XA00120D Type code The type code describes the exact design and the equipment of the measuring system. It can be read on the nameplate of the transmitter and sensor and is structured as follows: P R O M A S S 4 0 E * * * * * * * * * * * * * * + # * * # Pos. no.: 1 2 Instrument family Electronics 3 Sensor 4 to 5 Nominal diameter 6 Hyphen 7 Measuring pipe material 8 to 10 Process connection 11 Certificates 12 Calibration 13 14 15 Approvals Housing Cable entry 16 Power supply, display 17 Software 18 Inputs/outputs 19 Extended order code Approvals (Pos. no. 13 in type code) * Type of explosion protection Compact version Ex ia input/output Ex d[ia Ga] IIC T1~T6 Gb K, M Ex td [iad 20] A21 IP6X T* Ex d[ia Ga] IIB T1~T6 Gb L Ex td [iad 20] A21 IP6X T* Ex de[ia Ga] IIC T1~T6 Gb S, Q Ex td [iad 20] A21 IP6X T* Ex de[ia Ga] IIB T1~T6 Gb T Ex td [iad 20] A21 IP6X T* Non-intrinsically safe Ex d[ia] IIC T1~T6 Gb Ex td A21 IP6X T* Ex d[ia] IIB T1~T6 Gb Ex td A21 IP6X T* Ex de[ia] IIC T1~T6 Gb Ex td A21 IP6X T* Ex de[ia] IIB T1~T6 Gb Ex td A21 IP6X T* Sensor Ex ia IIC T1~T6 Gb Ex td iad A21 IP6X T* Ex ia IIB T1~T6 Gb Ex td iad A21 IP6X T* Ex ia IIC T1~T6 Gb Ex td iad A21 IP6X T* Ex ia IIB T1~T6 Gb Ex td iad A21 IP6X T* Housing (Pos. no. 14 in type code) * Type Min. ambient temperature T a min A Compact 20 C 1 40 C Cable entry (Pos. no. 15 in type code) * Thread form A M20 1.5 B 1/2" 14 NPT C G 1/2" Endress + Hauser 5

XA00120D Proline Promass 40 Inputs/outputs (Pos. no. 18 in type code) * Type of protection A, D Non-intrinsically safe S, T Ex ia! Note! For a detailed explanation of these values, regarding the available outputs and inputs, as well as a description of the associated terminal assignments and connection data: ä 7 onwards. Temperature table compact version Max. medium temperature [ C] for T1 T6 in relation to the maximum ambient temperature T a ) Promass 4*E**- DN [mm] 8 to 15 T a [ C] T6 (85 C) T5 (100 C) T4 (135 C) T3 (200 C) T2 (300 C) T1 (450 C) 100 130 +50 25 to 50 50 100 130 8 to 50 100 130 +60 80 60 95 110 The minimum medium temperature is 40 C for Promass E. The minimum ambient temperature is 20 C. A version for ambient temperatures T a up to 40 C is optionally available. Gas and dust explosion protection Determining the temperature class and surface temperature with the temperature table Determine the temperature class for gas in relation to the ambient T a and the medium temperature T m. Determine the maximum surface temperature for dust in relation to the maximum ambient temperature T a and the max. medium temperature T m. Example: Device: compact version, Promass 40 E, DN 25 Max. ambient temperature: T a = 60 C, max. medium temperature: T m = 98 C DN [mm] T a [ C] T6 (85 C) T5 (100 C) T4 (135 C) T3 (200 C) T2 (300 C) T1 (450 C) Promass 4*E** 8 15 25 50 8 50 80 +50 +60 50 60 100 100 100 95 130 130 130 110 DN 25 T a = 60 C T m = 100 C ( 98 C) Fig. 3: Procedure for calculating the max. surface temperature A0013402 1. Select the device (Promass 40 E), nominal diameter (DN 25) and ambient temperature Ta (50 C) in the associated temperature table (compact version). The row showing the maximum medium temperature is determined. 2. Select the maximum medium temperature Tm (98 C), which is smaller than or equal to the maximum medium temperature of a cell. The column with the temperature class for gas is determined (98 C 100 C T5). 3. The maximum temperature of the temperature class determined corresponds to the maximum surface temperature: T5 = 100 C = maximum surface temperature for dust. 6 Endress + Hauser

Esc sous E Proline Promass 40 XA00120D Design of measuring system m cover tight while Keep are alive circuits Nicht unter Spannung öffnen - + circuits are alive Keep cover tight while a m tension l appareil Ne pas ouvrir b Fig. 4: Design of the measuring system, compact/remote version a Connection compartment cover b Screw terminal for connecting to the potential equalization m see following section "Cable entries" A0013403 Cable entries For the connection compartment (Ex d version); power supply cable, circuit cable: Choice of cable gland M20 1.5 or thread for cable entries ½" NPT or G ½". Ensure that the Ex d cable glands/entries are secured against self-locking and the associated seals are arranged directly on the housing. For connection compartment (Ex e version); power supply cable, circuit cable: Choice of cable gland M20 1.5 or thread for cable entries ½" NPT or G ½". The cables must be installed such that they are fixed in place. Adequate strain relief must be ensured. # Warning! When using cable glands M20 1.5: Only approved cable glands may be used ( ä 2 "Installation instructions"). The cable glands must be very leak-tight. Cable specification You can find information about the cable specification in the associated Operating Instructions. Potential equalization The transmitter (compact and remote version) is to be securely connected to the potential equalization system using the screw terminal on the outside of the transmitter housing. Alternatively, the transmitter of the compact version as of serial number 4Axxxxxx000 can be connected to the potential equalization system via the pipeline if a ground connection via the pipeline according to regulations can be assured.! Note! Further information about potential equalization, shielding and grounding can be found in the associated Operating Instructions. Electrical connections Connection compartment Transmitter housing compact/remote version (terminal assignment, connection data ä 8 ff.) e + + + + N (L ) L1 (L+) 27 26 25 24 23 22 21 20 2 1 d b c a Fig. 5: Electrical connection for 4 to 20 ma HART a Power supply cable (terminal assignment and connection data ä 8) b Signal cable (terminal assignment and connection data ä 8) c Ground terminal for signal cable shield / fieldbus cable / RS485 line d Ground terminal for protective ground e Service adapter for connecting service interface FXA 193 (Fieldcheck, FieldCare) A0005611 Endress + Hauser 7

XA00120D Proline Promass 40 Terminal assignment and connection data, power supply Terminal assignment and connection data All transmitters 1 L (+) 2 N ( ) * Designation Supply voltage Protective earth Functional values AC: U = 85 to 260 V; AC: U = 20 to 55 V DC: U = 16 to 62 V Power consumption: 15 VA / 15 W Caution! Observe the grounding concepts of the system! Intrinsically safe circuit no U m 260 V AC Terminal assignment and connection data for signal circuits (intrinsically safe circuits)! Note! The table below contains the values which depend on the type code (type of device). Always remember to compare the type code in the table with the code on the nameplate of your device. For a graphic representation of the electrical connections: ä 7. Terminal assignment of transmitter 40***-***********S+#**# Assignment Terminal no. (inputs and outputs) 20 (+) 21 ( ) 22 (+) 23 ( ) 24 (+) 25 ( ) 26 (+) 27 ( ) Pulse/frequency output passive Current output HART active Electric circuit Ex ia Ex ia Safety-related values Functional values U i I i P i L i IIC C i IIC 30 V DC 500 ma 600 mw negligible 6 nf passive: 30 V DC / 250 ma, Open Collector full scale frequency = 2 to 1000 Hz U o I o P o L o IIC/IIB C o IIC/IIB L o IIC/IIB C o IIC/IIB U i I i P i L i IIC C i IIC 1) Permissible values for simultaneous occurrence of concentrated inductances and capacitances. 2) The circuitry must comply with the applicable regulations for electrical installations. active: 0/4 to 20 ma, R L < 400 R L HART 250 21.8 V DC 90 ma 491 mw 4.1 mh/15 mh 160 nf/1160 nf 2 mh/10 mh 1) 80 nf/300 nf 1) 30 V DC 2) 10 ma 2) 0.3 W 2) negligible 6 nf Terminal assignment of transmitter 40***-***********T+#**# Terminal no. (inputs and outputs) 20 (+) 21 ( ) 22 (+) 23 ( ) 24 (+) 25 ( ) 26 (+) 27 ( ) Assignment Pulse/frequency output Current output HART passive passive Electric circuit Ex ia Ex ia Safety-related values Functional values U i 30 V DC I i 500 ma P i 600 mw L i IIC negligible C i IIC i 6 nf passive: 30 V DC / 250 ma, Open Collector full scale frequency = 2 to 1000 Hz U i 30 V DC I i 100 ma P i 1.25 W L i IIC negligible C i IIC i 6 nf passive: 0/4 to 20 ma voltage drop 9 V R L < [(V p. supply 9 V) 25 ma] 8 Endress + Hauser

Proline Promass 40 XA00120D Terminal assignment and connection data for signal circuits (non-intrinsically safe circuits)! Note! The following tables contain values/specifications, which are dependent on the type code (type of measuring device). Please compare the following type code to the one shown on the nameplate of your measuring device. For a graphic representation of the electrical connections: ä 7. Terminal assignment Order characteristic Terminal no. (inputs and outputs) "Inputs/outputs" 20 (+) 21 ( ) 22 (+) 23 ( ) 24 (+) 25 ( ) 26 (+) 27 ( ) A Pulse/ frequency output Current output HART D Status input Status output Pulse/ frequency output Current output HART Safety-related and functional values of non-instrinsically safe circuit Signal circuits Functional values Safety-related values Current output HART active/passive can be selected: active: 0/4 to 20 ma R L < 700, R L HART 250 passive: 4 to 20 ma V s = 18 to 30 V DC, R i 150 intrinsically safe U m I m = no = 260 V = 500 ma Pulse/frequency output Status output Status input active/passive can be selected: active: 24 V DC / 25 ma (max. 250 ma during 20 ms) R L > 100 passive: 30 V DC / 250 ma Open Collector Full scale frequency 2 to 10 000 Hz (f max = 12 500 Hz) 3 to 30 V DC 250 ma 3 to 30 V DC R i = 5 k Service adapter The service adapter is exclusively for connection to E+H approved service interfaces. # Warning! It is not permissible to connect the service adapter in explosive atmospheres. Device fuse # Warning! Use only fuses of the following types; the fuses are installed on the power supply board: Voltage 20 to 55 V AC / 16 to 62 V DC: fuse 2.0 A slow-blow, disconnect capacity 1500 A (Schurter, 0001.2503 or Wickmann, Standard Type 181 2.0 A) Voltage 85 to 260 V AC: fuse 0.8 A slow-blow, disconnect capacity 1500 A (Schurter, 0001.2507 or Wickmann, Standard Type 181 0.8 A) Endress + Hauser 9

XA00120D Proline Promass 40 Technical data Dimensions Please refer to the respective Technical Information for these dimensions: Promass 40E TI00055D Weight The weight of the Ex d version is approx. 2 kg greater than that of the standard version. 10 Endress + Hauser

Proline Promass 40 XA00120D Endress + Hauser 11

XA00120D/06/EN/14.17 71359 FM+SGML 9.0 www.endress.com/worldwide