Temperature Sensor with Thread G1/4" FLEXadapt

Similar documents
Temperature Sensor without thread

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor Tri-Clamp

Temperature Sensor with M12 hygienic

Pharma Temperature Sensor G3/8"

Pharma Temperature Sensor G3/8"

Temperature Sensor G1/2" Standard

Temperature Sensor Tri-Clamp

Temperature Sensor with G1/2" hygienic

Temperature Sensor with M12 hygienic

Temperature Sensor G1/2" Standard

Pharma-Temperature Sensor M12 hygienic

Temperature Sensor Tri-Clamp

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Pharma Temperature Sensor TFP-EX

Continuous Level Sensor NSL-M

Inductive Conductivity Meter ILM

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Continuous Level Sensor NSL-M-00

ph or ORP Transmitter

Magnetic-Inductive flow Meter fmi

Screw-in resistance thermometers with plug connector

Conductivity Transmitter

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital flow ELEMENT transmitter for continuous flow measurement

Valve Island with Electronic I/O

Digital inductive conductivity transmitter

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital flow ELEMENT transmitter for continuous flow measurement

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Resistance thermometer Model TR30, compact design

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Resistance Thermometers Model Series TR7X0, Sheathed Design

ED701 General Industry Pressure Transmitter

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Resistance thermometer Model TR30, compact design

Digital conductivity transmitter

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Digital flowmeter for continuous flow measurement

Mineral-insulated resistance thermometers to EN

INLINE flowmeter for continuous flow measurement

OPTITEMP TT 20 Technical Datasheet

INLINE flowmeter for continuous flow measurement

Resistance thermometer Model TR31, miniature design

In-Line Resistance Thermometers Model TR25

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter for general industrial applications Model A-10

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

INSERTION paddle wheel flowmeter for continuous flow measurement

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

CombiTemp TCR6 Standard RTD temperature sensor

Electromagnetic Flow Transmitter

Electrical Temperature Measurement

Ultrasonic level transmitter, non-contact

Screw-in resistance thermometers with terminal head Form B

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

SMARTPAT PH 1590 Technical Datasheet

Pressure transmitter for general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

SMARTPAT COND 1200 Technical Datasheet

SW 16mm. SW 15mm. SW 19mm

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Wind Direction Transmitter - compact - GMR, analogue output xxx

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

INLINE flowmeter for continuous flow measurement

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Hygro-ThermoTransmitter-compact xxx

The transducer component converts the measured signal and displays the actual value.

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Technical Information itemp TMT180

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Precipitation Monitor ,

Rudder or propeller angular position transmitter KINAX WT720

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Resistance thermometers for process technology

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Pressure transmitter For general industrial applications Model A-10

Precipition Sensor with analogue Intensity Output ,

Indoor, outdoor and duct resistance thermometers

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Digital batch controller

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Operating Instructions for Microwave Level Switch. Model: LNM

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Transcription:

SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-414, -614, -814 FOOD Temperature Sensor with Thread G1/4" FLEXadapt Application/Specified usage Temperature measurement in weld-in thermowells and adapter Authorisations Application examples For mounting in existing weld-in thermowells and adapter with cap nut G1/4" Features Sensor made of stainless steel Sensor tip spring-loaded at TFP-414, -414.2 and TFP-614, -614.2 Changing or demounting without opening the process and electrical disconnecting Temperature sensor TFP-414 Options/Accessories 2 x Pt100 (not retrofittable) Programmable transmitter Programming adapter MPU-P 9701 Integrated transmitter for Profibus PA MPU-10 and HART-Protocol MPU-H Integrated transmitter MPU-LCD with display in connecting head Pt100-chip with other classes of accuracy, (1/3 B, 1/10 B) Electrical connection via M12-plug (standard at TFP-614, option for TFP-414) Pre-assembled connecting cable for M12-plug Fixed cable in other lengths and other materials available Build-In systems Suitable build-in systems for temperature sensors TFP-414, -614, -814 you will find in product information Process Connection FLEXadapt ESF. Temperature sensor TFP-614 with transmitter MPU-M

FOOD Specification 2 Temperature sensor Process connection thread G1/4" standard weld-in thermowell / screw-in thermowell e. g. Hengesbach Quicktemp-Hülse zeh / TP136 T500 Insertion length EL Materials Operating pressure Temperature ranges TFP-414, TFP-414.2, TFP-614 TFP-814 connection head pipe ambient sensor tip Measurement resistor acc. to DIN EN 60751 Pt100 Electrical connection Protection class TFP-414, TFP-414.2 TFP-614 TFP-814 61 mm, 115 mm + 2 mm spring travel 61 mm, 115 mm stainless steel 1.4305 stainless steel 1.4404 acc. to manufacturer information of the thermowell -50...+80 C -50...+250 C cable gland M16x1,5 M12-plug 1.4305 M12-plug 1.4305 fixed cable (LIYY 4 x 0,25 mm²) standard 2,5 m IP 69 K (with electrical connection M12-plug) Transmitter MPU-4, MPU-10, MPU-H, MPU-M Temperature ranges Measuring ranges ambient storage MPU-4, MPU-H, MPU-M MPU-10-40...+85 C -55...+90 C Accuracy input < ±0.25 C Temperature drift zero, span < 0.01 % / K Supply Output MPU-M, MPU-4 MPU-10 accuracy signal accuracy burden Humidity without condensation 0...98 % standard: -10...40 C, 0...50 / 100 / 150 / 200 C special ranges free programable standard: -200...850 C configuration occurs with Profibus 8...35 V DC 9...32 V DC 0.01 % / V (reference: 12 V DC) analog 4...20 ma (not for MPU-10) < ±0.1 % of measurement range < 600 Ω (at U B = 24 V) Accuracy classes of temperature sensors Tolerances for Pt100 acc. to DIN EN 60751 Pt100 A 1/3 B 1/10 B 0 C / 100 Ω ±0.15 K / ±0.06 Ω ±0.10 K / ±0.04 Ω ±0.03 K / ±0.01 Ω 100 C / 138.5 Ω ±0.35 K / ±0.13 Ω ±0.27 K / ±0.10 Ω ±0.08 K / ±0.03 Ω

3 Electrical Connection FOOD Elektrischer Electrical connection Anschluss without ohne Kopftransmitter Elektrischer Electrical connection Anschluss with mit Kopftransmitter With 1 x M12 plug Belegung Configuration 1. M12-Stecker 1st plug 1 2 3 4 With M12 plug Configuration Belegung M12 plug M12-Stecker 1: +supply 2: -supply 4...20 ma 3: not connected 4: not connected With 1 x M12 plug and 2 x Pt100 Belegung Configuration 2. M12-Stecker 2nd plug 1 4 2 3 With cable gland 4...20 ma current loop 4...20 ma Stromschleife 1. Pt100 2. Pt100 With cable gland Belegung Configuration Klemmen strip terminal 1 2 3 4 Klemmen clamps for für 1st 1. Pt100 Klemmen clamps for für 2nd 2. Pt100 (bei (at version Ausführung 2 x Pt100) 2 x Pt100) With fixed cable Belegung Fixed cable Kabel connection mit 1 with x Pt100 1 x Pt100 Belegung Fixed cable Kabel connection mit 2 with x Pt100 2 x Pt100 (LIYY) (LIYY) Fixed Belegung cable Kabel connection mit with 2 x Pt100 2 x Pt100 (PTFE) (PTFE)

FOOD Dimensioned Drawings 4 TFP-414 TFP-414.2 TFP-614 with MPU-M TFP-814 Insertion length EL + 2 mm spring travel Insertion length EL TFP-614 TFP-624 Insertion length EL + 2 mm spring travel Insertion length EL + 2 mm spring travel

5 Important Informations FOOD Mechanical connection/installation Check the compatibility of the sensor to the used immersion sleeve. Conventional usage Not suitable for applications in explosive areas. Not suitable for applications in security-relevant equipments (SIL). Transport/Storage No outdoor storage Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage temperature -55 C...+90 C Relative humidity max. 98 % Reshipment Sensors shall be clean and must not be contaminated with dangerous media! Use suitable transport packaging only to avoid damage of the equipment! Cleaning/Maintenance In case of using pressure washers, dont t point nozzle directly to electrical connections! Standards and guidelines You have to comply with applicable regulations and directives. Advice to EMC The device agrees to following standards: EMC directive 2004/108/EC. You have to guarantee the EMC directives for the entire equipement. Disposal This instrument is not subject to the WEEE directive 2002/96/EC and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points.

FOOD Option MPU-LCD Accessories 6 Temperature Transmitter MPU-LCD with Display Application/Specified usage 4...20 ma transmitter with LCD for Pt100 temperature sensor For installation in temperature sensor Sensor monitoring Option MPU-LCD (display in the connection head) Features 4-digit display with green backlight Temperature measurement in C and F Easy range select by one button Lower costs for wiring because of 2-wire technology Note See product information MPU-LCD for details. Accessories PVC-cable with M12-connection PVC-cable with M12-connection made of 1.4305, IP 69 K, unshielded M12-PVC / 4-5 m PVC-cable 4-pin, length 5 m M12-PVC / 4-10 m PVC-cable 4-pin, length 10 m M12-PVC / 4-25 m PVC-cable 4-pin, length 25 m PVC-cable with M12-connection, brass nickel-plated, IP 67, shielded M12-PVC / 4G-5 m PVC-cable 4-pin, length 5 m M12-PVC / 4G-10 m PVC-cable 4-pin, length 10 m M12-PVC / 4G-25 m PVC-cable 4-pin, length 25 m Programming adapter MPU-P 9701 Programming adapter MPU-P 9701 Programming adapter for MPU-4, MPU-H and MPU-M

7 Order Code FOOD Order code for version with 1 x Pt100 TFP-414 TFP-614 TFP-814 (connection head Ø 55 mm and spring-loaded sensor tip) (connection head Ø 18 mm and spring-loaded sensor tip, electrical connection via M12-plug) (connection head Ø 18 mm, electrical connection 2,5 m PVC-cable) Sensor length EL 61 (length 61 mm) 115 (length 115 mm) xxx (special length) Diameter thermowell in mm 3 Diameter sensor tip in mm 3 Accuracy class Pt100 A 1/3B 1/10B Electrical connection (only selectable for TFP-414) PG (cable gland M16x1,5) M12 (M12-plug 1.4305, standard with MPU-LCD) Transmitter only for TFP-414 X (without) MPU-4 (programmable) MPU-10 (Profibus PA) MPU-H (HART-protocol) MPU-LCD (with display) Transmitter only for TFP-614 X (without) MPU-M (programmable) Measurement range (only for types with transmitter; not at MPU-LCD) -10...40 (measurement range -10...+40 C) 0...50 (measurement range 0...+50 C) 0...100 (measurement range 0...+100 C) 0...150 (measurement range 0...+150 C) 0...200 (measurement range 0...+200 C) xx...yy (special range) TFP-414 / 115 / 3 / 3 / A / M12 / MPU-4 / 0...150

FOOD Product Information TFP-414, -614, -814 8 Order code for version with 2 x Pt100 TFP-414.2 TFP-614.2 (connection head Ø 55 mm and spring-loaded sensor tip, no transmitter possible!) (connection head Ø 18 mm and spring-loaded sensor tip, electrical connection via M12-plug, no transmitter possible!) Sensor length EL 61 (length 61 mm) 115 (length 115 mm) xxx (special length) Diameter thermowell in mm 3 Diameter sensor tip in mm 3 Accuracy class Pt100 A 1/3B 1/10B Electrical connection (only selectable for TFP-414.2) PG (cable gland M16x1,5) M12 (M12-plug 1.4305) TFP-414.2 / 115 / 3 / 3 / A / M12 50018 / 3.0 / 2015-01-13 / TB / EU NEGELE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720