SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Similar documents
PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

SDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL

Model 7000 Low Noise Differential Preamplifier

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY SYNTHESIZER LNFS-400 OPERATING MANUAL

SDI SPECTRADYNAMICS, INC.

SPECTRADYNAMICS, INC.

Instruction Manual Model M Switch, DPDT, Manual Select

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual

VT1586A Rack Mount Terminal Panel Installation and User s Manual

MODEL 3810/2 Line Impedance Stabilization Network

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Model Hz to 10MHz Precision Phasemeter. Operating Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

Signal Forge 1800M Frequency Expansion Module. 1.0 GHz to 1.8 GHz. User Manual

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY SYNTHESIZER LNFS-100 OPT 3 OPERATING MANUAL

Amplifier Series BASIC. Installation & Operations Manual

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

A Channel Amplifier

HTA125A/250A. Power Amplifiers. Installation & Use Manual

Opus 21 s80 Integrated Amplifier Owner's Manual

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User s Guide ASSISTIVE LISTENING SYSTEMS

TIA-3000 Optical/Electrical Converter. Operating Instructions

INSTRUCTION MANUAL LKG

200Amp AC Clamp Meter + NCV Model MA250

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

USER'S MANUAL DMR-6700

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

HydroLynx Systems, Inc.

User Guide. Digital AC/DC Clamp Meter Model 38394

High Performance Microphone Splitter. Artcessories. User's Manual

KeyPre KP6 - Electronic Instrument Preamplifier

User s Guide. Digital AC/DC Clamp Meter Model 38394

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

PCO-7114 Laser Diode Driver Module Operation Manual

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

EQ-AMP60 60W Mixer Amplifier

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

SDI SPECTRADYNAMICS, INC. Low Noise Frequency Synthesizer LNFS-100 Operating Manual

Model 1791 VHF Radio User's Manual

PDB4. Four Channel Passive Direct Box USER'S GUIDE

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Autoranging Multimeter Extech EX503

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

Model 3210C. 100 Ampere AC Current Standard. Operating Manual

American Power Design, Inc.

PA8HF power amplifier Operating guide

American Power Design, Inc.

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

TIA-4000 Optical/Electrical Converter. Operating Instructions

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Assistive Listening Systems. RX-6 User s Guide

SDI SPECTRADYNAMICS, INC. HIGH RESOLUTION OFFSET GENERATOR HROG-10 OPERATING MANUAL

DDS Function Generator

Model CC4052. CC Series Amplifier. Installation and Use Manual

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

INSTALLATION AND OPERATING MANUAL

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

Cover for IPA 75/150T II

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

OPERATING AND MAINTENANCE MANUAL

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

M2/M2A AC-DC Power Supply Operator s Manual

Model CC4041. CC Series Amplifier. Installation and Use Manual

Broadband Power Amplifier

Wilcoxon Research PA8HF power amplifier Operating guide

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Amplified High Speed Photodetectors

Model 1152-ALN Phase Locked Oscillator

441 DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER 451 SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Pen Multimeter. Model

Signal Conditioning Amplifier

American Power Design, Inc.

Model 4007DDS. 7 MHz Sweep Function Generator

MICROTUBE 100. OWNER S MANUAL (version 1)

Advanced Test Equipment Rentals ATEC (2832)

2100L Broadband Power Amplifier

User s Guide. 400A AC/DC Clamp Meter. Model MA220

COM-POWER OPERATION MANUAL ACS W

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

Pen Multimeter. Model

N2790A Differential Voltage Probe

A-16D A-Net Distributor

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

TIA-2000 Optical/Electrical Converter. Operating Instructions

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

Transcription:

SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER HPDA15RMC OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 6651852 Fax: (303) 6046088 www.spectradynamics.com

Description The HPDA15RMC is a high performance distribution and isolation amplifier. The standard unit contains three HPDA5 modules. Each module provides five unity gain outputs for every input signal. The HPDA15RMC may be modified upon request to contain only two HPDA5 modules. The following specifications are valid for any HPDA15RMC that provides five unity gain outputs for every input signal. Typical crosschannel isolation is 125 db and reverse isolation is typically greater than 135 db. The phase noise of the modules is exceptionally low, typically 150 dbc/hz @ Fourier frequency of 1 Hz and 172 dbc/hz @ Fourier frequency greater than 10 khz. Both the input and output are matched to 50 ohms to obtain better than 25 db return loss. All outputs are AC coupled and the grounds are DC isolated to reduce the effect of ground loops. SPECTRADYNAMICS, INC 1848 Cherry St Unit 2. Louisville, CO 80027 Phone: (303) 6651852 Fax: (303) 6046088 Se habla español Copyright SpectraDynamics, Inc. 2010 1

Safety and Preparation for Use CAUTION! Voltages capable of causing injury or death are present in this instrument. Use extreme caution whenever the instrument cover is removed. Line Voltage This instrument may be setup to operate on 100120 or 220240 VAC and a line frequency of 50 to 60 Hz. The setup voltage for this HPDA15RMC is specified on page 4. Fuse A 0.50 Ampere 250V slowblow fuse is used for 100120 VAC operation. A 0.25 Ampere 250V slowblow fuse is used for 220240 VAC operation. Only replace fuses with the same type and specifications. Line Cord The instrument has a detachable, three wire power cord for connection to a grounded power source. The enclosure of the unit is directly connected to the outlet ground to protect against electrical shock. Always use an outlet with a protective ground and do not disable this safety mechanism. Service Do not attempt to service or adjust the instrument unless another person, capable of providing first aid or resuscitation, is present. Contact for any questions or repairs. SpectraDynamics, Inc. 1849 Cherry Street Unit 2. Louisville, CO 80027 USA Tel: (303) 6651852 Fax: (303) 6046088 support@spectradynamics.com www.spectradynamics.com 2 Copyright SpectraDynamics, Inc. 2010

The Front Panel AC Power LED The AC POWER LED will turn on when AC power is applied to unit and the unit is operating properly. DC Power LED The DC POWER LED is on when DC power is applied to unit and the unit is operating properly. Monitor LED The MONITOR LED of each module will turn on if all the output signals to the corresponding module are greater than +7 dbm. Copyright SpectraDynamics, Inc. 2010 3

The Back Panel AC POWER ENTRY MODULE The HPDA15RMC is configured to operate on: 100120 VAC 220240 VAC DC POWER ENTRY MODULE Optional Battery Backup Connector for +24 VDC Backup power source. SMA INPUTS The standard HPDA15RMC contains three amplifier modules each having one input SMA connector. If you acquired a modified unit with only two HPDA modules the back panel will contain only two SMA input connectors. The signal to be distributed should be connected to the corresponding SMA jack labeled INPUT. SMA OUTPUTS There are five SMA OUTPUTS for each SMA INPUT. Any output may be used to drive the input of another distribution module. The five outputs of each amplifier module are DC isolated from the chassis ground to prevent ground loops. Make sure that the amplifier ground does not float to a potential greater than 50 VDC from the chassis ground. An output ground potential greater than 50 VDC will damage the amplifier and could cause injury or death to personnel. 4 Copyright SpectraDynamics, Inc. 2010

Battery Backup Module Description The battery backup module allows the HPDA15RMC instrument to be powered by a +24 VDC power source in case of loss of the main AC power. The switch from AC to DC supply operation is affected by a Schottky diode network and charge storage capacitors to ensure glitch free operation. The +24 VDC power source connector is located on the back panel of the instrument. The +24 VDC ground is not connected to the instrument case ground internally, however both ground connections are available at the DC power connector and may be connected together at this point. DC Voltage The +24 VDC may be used as backup power to prevent loss of signal during power outages. The DC power supply should be able to provide +24 VDC at 2A. For optimum performance the following specifications should be used for the power supply. DC Supply Line regulation Load regulation Output ripple DC Fuse +24 VDC, 2 A +/ 0.05% for a 10% line change +/ 0.05% for a 50% load change < 5mV peaktopeak 2.0 Ampere 250V slowblow Fuse A 2.0 Ampere 250V slowblow fuse is used for +24 VDC operation. Replace fuses with the same type and specifications Service Do not attempt to service or adjust the instrument unless another person, capable of providing first aid or resuscitation, is present. Contact for any questions or repairs. Operation To operate the unit on DC power, locate the DC power entry connector on the rear panel and connect the power cable. When DC power is applied to the unit, the LED located on the front panel labeled DC POWER should light up. Connection of the +24 VDC supply is optional. Copyright SpectraDynamics, Inc. 2010 5

DC Connector WARNING! DO NOT APPLY AC VOLTAGE TO THIS UNIT THROUGH THE 6 PIN CONNECTOR ON THE REAR OF THE UNIT! Failure to follow these directions will cause injury or death to personnel, cause irreparable damage to the instrument and void all warranties. WARNING! DO NOT REVERSE THE POLARITY OF THE SUPPLY VOLTAGE! Reversing the polarity of the power supply will cause damage to the unit and void all warranties. WARNING! The chassis of the instrument is internally connected to DC ground. The +24 VDC connector is wired as follows: Pin 1 NC Pin 2 NC Pin 3 NC Pin 4 +24 VDC GND return Pin 5 +24 VDC power Pin 6 Chassis GND / Earth GND 6 Copyright SpectraDynamics, Inc. 2010

Operation This unit is designed to operate only with the specified AC voltage on page 4 and +24 VDC. For conversion to a different voltage of operation contact SpectraDynamics, Inc. To operate the unit, locate the AC power entry module on the rear of the enclosure and/or the DC connector and connect the power cord(s). Plug the unit into an appropriate power outlet. The LED on the front panel labeled AC POWER will turn on when you apply the AC voltage. If you also apply the DC voltage the LED labeled DC POWER on the front panel should light up. Attach the signal to be distributed to one of the SMA input connectors on the back panel. Any HPDA15RMC output may be used to drive the input of another distribution module. Absolute Maximum Ratings Input power +20dBm Maximum Reverse Power +20dBm Maximum Input DC Voltage 10 VDC Maximum Output DC Voltage 50 VDC Maximum Storage Temperature 10 to +75 ºC Operation Environment 0 to +50 ºC Rack Mount Chassis 1U H, 19 W, 14 D Copyright SpectraDynamics, Inc. 2010 7

Specifications PARAMETER CONDITIONS MIN TYP MAX UNITS Max. Input Power 1 db compression 16 17 dbm Bandwidth +/ 1 db 1 20 MHz Gain @ 5 MHz +/ 0.5 db Impedance input output 50 50 Ohms Return Loss input(s11) 5MHz 35 25 db output(s22) 5MHz 25 25 Distortion +13 dbm +16 dbm 45 40 40 dbc Isolation output to output output to input 120 120 126 135 db Phase Noise Temperaturedelay Coefficient 1 Hz 10 Hz 1 khz 10 khz 0 50 ºC 25 35 ºC All tests done at 5 MHz and +13 dbm input unless otherwise specified. 150 165 171 172 3 1.5 147 157 169 170 5 dbc/hz ps/ºc 8 Copyright SpectraDynamics, Inc. 2010

Warranty The HPDA15RMC is warranted to be free of defects under normal operating conditions, as specified, for one year from date of original shipment from SpectraDynamics, Inc (). s obligation and liability under this warranty is expressly limited to repairing or replacing, at s option, any product not meeting the said specifications. This warranty shall be in effect for one (1) year from the date a HPDA15RMC is sold by. makes no other warranty, express or implied, and makes no warranty of the fitness for any particular purpose. s obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay. Any improper use, operation beyond capacity, substitution of parts not approved by, or any alteration or repair by others in such manner as in s reasonable judgement affects the product materially and adversely shall void this warranty. No employee or representative of is authorized to change this warranty in any way or grant any other warranty. SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 6651852 Fax: (303) 6046088 Se habla español Copyright SpectraDynamics, Inc. 2010 9