EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Similar documents
EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Test Report GUANGDONG EAST POWER CO., LTD

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

PT. SARANA KARYA SOLUSINDO.

2620 Modular Measurement and Control System

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

TEST REPORT... 1 CONTENT...

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

1 SUMMARY OF STANDARDS AND RESULTS

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Test Report GUANGDONG EAST POWER CO., LTD

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT. According to

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC TEST REPORT For : SHENZHEN HITEVISION TECHNOLOGY CO., LTD. Interactive Whiteboard

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

9. Electrostatic Discharge Immunity Test (ESD)

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

EMC VERIFICATION SUMMARY Report No.: SZHH

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

EMC Test Report. Report Number: M030826

EMC TEST REPORT. according to

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

CE/EMC TEST REPORT. For. Noron Ltd.

CE EMC TEST REPORT. According to

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

Declaration of Conformity

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M

EMC Test report for LED Panel Light Models , , , , ,

for Issued for Supremevalue Technology CO., Ltd 4/F,A4 Bldg.,Yinlong Industrial Park,292# Shenshan Rd,518116, Longgang District,Shenzhen,China.

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT for SmartAV Ses Goruntu Sistemleri Tic. Ltd. Sti. Video Conferencing Camera. Model No.: UV510A-S20-ST

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

CE EMC Test Certification

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

TEST REPORT. Issued for:

LS200 TEST DATA IEC61000 SERIES

EMC MEASUREMENT AND TEST REPORT

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

EMC TEST REPORT. Draft ETSI EN /-3 For

EMC test report AU01+E04

CE TEST CERTIFICATION

Communication Certification Laboratory

C E R T I F I C A T I O N

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

Transcription:

EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Report Number : EMC-E20130903E Date of Test : Aug. 10, 2013 to Sept. 5, 2013 Date of Report : Sept. 5, 2013 Page 1 of 56

Description TABLE OF CONTENT EMC-E20130903E Page 1. GENERAL INFORMATION... 5 1.1. Description of Device (EUT)... 5 1.2. Description of Test Facility... 6 1.3. Measurement Uncertainty... 6 2. MEASURING DEVICE AND TEST EQUIPMENT... 7 2.1. For Mains terminals Disturbance voltage Test... 7 2.2. For Radiated Emission Measurement... 7 2.3. For Electrostatic Discharge Immunity Test... 7 2.4. For RF Strength Susceptibility Test... 8 2.5. For Electrical Fast Transient /Burst Immunity Test... 8 2.6. For Surge Immunity Test... 8 2.7. For Injected Current Susceptibility Immunity Test... 8 2.8. For Voltage Dips and Interruptions Test... 9 3. POWER LINE CONDUCTED EMISSION MEASUREMENT... 10 3.1. Block Diagram of Test Setup... 10 3.2. Measuring Standard... 10 3.3. EUT Configuration on Measurement... 10 3.4. Operating Condition of EUT... 11 3.5. Test Procedure... 11 3.6 Measuring Results... 11 4. RADIATED EMISSION MEASUREMENT... 12 4.1. Block Diagram of Test... 12 4.2. Measuring Standard... 12 4.3. Radiated Emission Limits... 13 4.4. EUT Configuration on Test... 13 4.5. Operating Condition of EUT... 13 4.6. Test Procedure... 13 4.7. Measuring Results... 13 5. HARMONIC CURRENT EMISSION MEASUREMENT... 14 5.1 Block Diagram of Test Setup... 14 5.2 Measuring Standard... 14 5.3 Operation Condition of EUT... 14 5.4 Measuring Results... 14 6. VOLTAGE FLUCTUATION AND FLICKER MEASUREMENT... 15 6.1 Block Diagram of Test Setup... 15 6.2 Measuring Standard... 15 6.3 Operation Condition of EUT... 15 6.4 Measuring Results... 15 7. ELECTROSTATIC DISCHARGE IMMUNITY TEST... 16 7.1 Block Diagram of Test Setup... 16 7.2 Test Standard... 16 7.3 Severity Levels... 16 7.4 EUT Configuration... 16 7.5 Operating Condition of EUT... 16 7.6 Test Procedure... 17 7.7 Test Results... 17 8. RF FIELD STRENGTH SUSCEPTIBILITY TEST... 19 8.1 Block Diagram of Test... 19 8.2 Test Standard... 19 8.3 Severity Levels... 20 Page 2 of 56

EMC-E20130903E 8.4 EUT Configuration on Test... 20 8.5Operating Condition of EUT... 20 8.6 Test Procedure... 20 8.7 Test Results... 20 9. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST... 22 9.1 Block Diagram of Test Setup... 22 9.2 Test Standard... 22 9.3 Severity Levels... 22 9.4 EUT Configuration... 23 9.5 Operating Condition of EUT... 23 9.6 Test Procedure... 23 9.7 Test Result... 23 10. SURGE IMMUNITY TEST... 26 10.1 Block Diagram of Test Setup... 26 10.2 Test Standard... 26 10.3 Severity Levels... 26 10.4 EUT Configuration... 26 10.5 Operating Condition of EUT... 27 10.6 Test Procedure... 27 10.7 Test Result... 27 11. INJECTED CURRENTS SUSCEPTIBILITY TEST... 28 11.1 Block Diagram of Test Setup... 28 11.2 Test Standard... 29 11.3 Severity Levels... 29 11.4 EUT Configuration... 29 11.5 Operating Condition of EUT... 29 11.6 Test Procedure... 29 11.7 Test Results... 30 12. MAGNETIC FIELD SUSCEPTIBILITY TEST... 32 12.1 Block Diagram of Test... 32 12.2 Test Standard... 32 12.3 Severity Levels... 32 12.4 EUT Configuration on Test... 32 12.5 Test Procedure... 33 12.6 Test Results... 33 13. VOLTAGE DIPS AND INTERRUPTIONS TEST... 34 13.1 Block Diagram of Test Setup... 34 13.2 Test Standard... 34 13.3 Severity Levels... 34 13.4 EUT Configuration... 34 13.5 Operating Condition of EUT... 35 13.6 Test Procedure... 35 13.7 Test Result... 35 14. TEST PHOTOGRAPH... 37 15.1 Photo of Conducted Emission Measurement... 37 15.2 Photo of Radiation Emission Measurement... 37 15.3 Photos of Electrostatic Discharge Test... 38 15.4 Photos of RF Field Strength susceptibility Test... 38 15.5 Photo of Electrical Fast Transient /Burst Test... 39 15.6 Photo of Surge Test... 39 15.7 Photo of Voltage Dips and Interruption Immunity Test... 40 APPENDIX I (4 Pages) APPENDIX II (4 Pages) APPENDIX Ⅲ (Photos of EUT) (8 pages) Page 3 of 56

TEST REPORT VERIFICATION EMC-E20130903E Applicant : MPP SOLAR INC Manufacturer : MPP SOLAR INC EUT : Inverter/ Charger Trade Mark : -- Model Number : PIP 4048HS Input Voltage : 208-240V~, 50/60Hz Measurement Procedure Used: EN55022: 2010 EN55024:2010 (EN61000-4-2:2009, EN 61000-4-3: 2006+A2: 2010, EN61000-4-11:2004, EN 61000-4-4:2004+A1:2010, EN61000-4-5:2006, EN61000-4-6:2009) The device described above is tested by MPP SOLAR INC to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and MPP SOLAR INC is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the EN 62040-2 requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of MPP SOLAR INC Date of Test : Aug. 10, 2013 to Sept. 5, 2013 Prepared by : Fredricker Reviewer : Kevin Approved & Authorized signer : Page 4 of 56

EMC-E20130903E 1. GENERAL INFORMATION 1.1. Description of Device (EUT) EUT : Inverter/ Charger Model Number : PIP 4048HS Test voltage : AC 230V/50Hz, Rating : Applicant : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Manufacturer : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Date of receiver : Sept. 5, 2013 Date of Test : Aug. 10, 2013 to Sept. 5, 2013 Page 5 of 56

EMC-E20130903E 1.2. Description of Test Facility Site Description EMC Lab. : Name of Firm : Site Location : 1.3. Measurement Uncertainty Radiation Uncertainty : Ur = ±2.7dB Conduction Uncertainty : Uc = ±3.4dB Page 6 of 56

EMC-E20130903E 2. MEASURING DEVICE AND TEST EQUIPMENT 2.1. For Mains terminals Disturbance voltage Test 2.2. For Radiated Emission Measurement 2.3. For Electrostatic Discharge Immunity Test Page 7 of 56

EMC-E20130903E 2.4. For RF Strength Susceptibility Test 2.5. For Electrical Fast Transient /Burst Immunity Test 2.6. For Surge Immunity Test 2.7. For Injected Current Susceptibility Immunity Test Page 8 of 56

EMC-E20130903E 2.8. For Voltage Dips and Interruptions Test Page 9 of 56

EMC-E20130903E 3. POWER LINE CONDUCTED EMISSION MEASUREMENT 3.1. Block Diagram of Test Setup 3.2. Measuring Standard 3.3. EUT Configuration on Measurement The following equipments are installed on Conducted Emission Measurement to meet EN 55022 requirements and operating in a manner which tends to maximize its emission characteristics in a normal application. Inverter/ Charger (EUT) Model Number : PIP 4048HS Page 10 of 56

EMC-E20130903E Serial Number : N/A 3.4. Operating Condition of EUT 3.4.1.Setup the EUT as shown on Section 3.1. 3.4.2.Turn on the power of all equipments. 3.4.3.Let the EUT work in measuring mode (Line mode/ Battery mode) and measure it. 3.5. Test Procedure The EUT is put on the plane 0.8m high above the ground by insulating support and connected to the AC mains through Line Impedance Stability Network (L.I.S.N). This provided a 50ohm coupling impedance for the tested equipments. Both sides of AC line are investigated to find out the maximum conducted emission according to the EN 62040-2 regulations during conducted emission measurement. The bandwidth of the field strength meter is set at 9KHz in 150KHz~30MHz and 200Hz in 9KHz~150KHz. The frequency range from 150kHz to 30MHz is investigated All the scanning waveform is put in Appendix I. 3.6 Measuring Results PASS. Please reference to APPENDIX I Page 11 of 56

EMC-E20130903E 4. RADIATED EMISSION MEASUREMENT 4.1. Block Diagram of Test 4.1.1.Block diagram of connection between the EUT and simulators AC Mains EUT Full load Notebook (EUT: UPS) 4.1.2.Block diagram of test setup (In chamber) 3m Spectrum Analyzer Turntable EUT 0.8m 1m to 4m Ground Plane Coaxial Cable (EUT: UPS) 4.2. Measuring Standard EN55022 Class A Page 12 of 56

EMC-E20130903E 4.3. Radiated Emission Limits All emanations from device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified below: FREQUENCY DISTANCE FIELD STRENGTHS LIMIT (MHz) (Meters) (dbμv/m) 30 ~ 230 3 50 230 ~ 1000 3 57 Note: (1) The smaller limit shall apply at the combination point between two frequency bands. (2) Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the EUT. 4.4. EUT Configuration on Test The EN 55022 regulations test method must be used to find the maximum emission during radiated emission measurement. 4.5. Operating Condition of EUT 4.5.1.Turn on the power. 4.5.2.After that, let the EUT work in test mode (Line mode/battery mode) and measure it. 4.6. Test Procedure The EUT is placed on a turn table which is 0.8 meter high above the ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Bilog antenna (calibrated by Dipole Antenna) is used as a receiving antenna. Both horizontal and vertical polarization of the antenna are set on test. The bandwidth of the Receiver is set at 120kHz. All the scanning curves are attached in Appendix II. 4.7. Measuring Results PASS. The frequency range from 30MHz to 1000MHz is investigated. Please reference to APPENDIX II Page 13 of 56

EMC-E20130903E 5. HARMONIC CURRENT EMISSION MEASUREMENT 5.1 Block Diagram of Test Setup AC Mains Power frequency test system EUT Full load Notebook (EUT: UPS) 5.2 Measuring Standard EN61000-3-2: 2006+A1: 2009+A2:2009 CLASS A 5.3 Operation Condition of EUT Same as Section 3.4, except the test setup replaced as Section 5.1. 5.4 Measuring Results N.A. Page 14 of 56

EMC-E20130903E 6. VOLTAGE FLUCTUATION AND FLICKER MEASUREMENT 6.1 Block Diagram of Test Setup AC Mains Power frequency test system EUT Full load Battery (EUT: UPS) 6.2 Measuring Standard EN 61000-3-3: 2008 6.3 Operation Condition of EUT Same as Section 3.4, except the test setup replaced as Section 6.1. 6.4 Measuring Results N.A. Page 15 of 56

EMC-E20130903E 7. ELECTROSTATIC DISCHARGE IMMUNITY TEST 7.1 Block Diagram of Test Setup 7.1.1 Block diagram of connection between the EUT and simulators AC Mains EUT Full load Notebook 7.1.2 Block diagram of ESD test setup EUT ESD Tester 0.8 m AC Mains AC Mains (EUT: UPS) 7.2 Test Standard EN61000-4-2: 2009 (Air Discharge:±8KV, Contact Discharge:±4KV) 7.3 Severity Levels Level Test Voltage Test Voltage Contact Discharge (KV) Air Discharge (KV) 1. ±2 ±2 2. ±4 ±4 3. ±6 ±8 4. ±8 ±15 X Special Special 7.4 EUT Configuration The configuration of EUT are listed in Section 3.4. 7.5 Operating Condition of EUT Same as conducted emission measurement, which is listed in Section3.5. except the Page 16 of 56

EMC-E20130903E test set up replaced by Section 7.1. 7.6 Test Procedure 7.6.1 Air Discharge: This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed 7.6.2 Contact Discharge: All the procedure shall be same as Section 7.6.1. except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. 7.6.3 Indirect discharge for horizontal coupling plane At least 10 single discharges(in the most sensitive polarity) shall be applied at the front edge of each HCP opposite the center point of each unit(if applicable) of the EUT and 0.1m from the front of the EUT. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to its front edge during the discharge. 7.6.4 Indirect discharge for vertical coupling plane At least 10 single discharge (in the most sensitive polarity) shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated. 7.7 Test Results PASS Please refer to the following pages Page 17 of 56

Electrostatic Discharge Test Result EMC-E20130903E Page 18 of 56

8. RF FIELD STRENGTH SUSCEPTIBILITY TEST 8.1 Block Diagram of Test 8.1.1 Block diagram of connection between the EUT and Load AC Mains EUT (EUT: UPS) Full load Notebook 8.1.2 Block diagram of RS test setup 7x4x3Chamber 3 meter EUT & Support Units 1.5 meter 0.8m Power Amp Signal Generator EUT Monitoring by using a camera PC Controller to control S.G. & PA as well as forward power (EUT: UPS) 8.2 Test Standard EN61000-4-3: 2006+A1:2008+A2:2010 (3V / m) Page 19 of 56

8.3 Severity Levels Level Field Strength V/m 1. 1 2. 3 3. 10 X Special 8.4 EUT Configuration on Test The configuration of the EUT is same as Section 3.4. 8.5Operating Condition of EUT Same as radiated emission measurement which is listed in Section 3.5, except the test setup replaced as Section 8.1. 8.6 Test Procedure The EUT are placed on a table which is 0.8 meter high above the ground. The EUT is set 3 meters away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of the EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor its screen. All the scanning conditions are as following: Condition of Test Remark ---------------------------------------------- --------------------------------------- 1. Fielded Strength 10V/m 2. Radiated Signal Modulated 3. Scanning Frequency 80-1000MHz 4. Sweep time of radiated 0.0015 Decade/s 5. Dwell Time 1 Sec. 8.7 Test Results PASS. Please refer to the following page. Page 20 of 56

RF Field Strength Susceptibility Test Results Page 21 of 56

9. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 9.1 Block Diagram of Test Setup 9.1.1.Block Diagram of the EUT AC Mains EUT Full load Notebook (EUT: UPS) 9.1.2.EFT Test Setup AC Port: AC Mains EUT EFT/B Tester 0.8 m AC Mains 9.2 Test Standard EN61000-4-4: 2004+A1:2010 (Level: 1KV/5KHz) 9.3 Severity Levels Open Circuit Output Test Voltage ±10% Page 22 of 56

Level On Power Supply Lines On I/O (Input/Output) Signal data and control lines 1. 0.5 KV 0.25 KV 2. 1 KV 0.5 KV 3. 2 KV 1 KV 4. 4 KV 2 KV X Special Special 9.4 EUT Configuration The configuration of EUT are listed in Section 3.4. 9.5 Operating Condition of EUT 9.5.1 Setup the EUT as shown in Section 9.1. 9.5.2 Turn on the power of all equipments. 9.5.3 Let the EUT work in test mode (Line mode) and measure it. 9.6 Test Procedure The EUT is put on the table which is 0.8 meter high above the ground. This reference ground plane shall project beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. 9.6.1 For input and output AC power ports: The EUT is connected to the power mains by using a coupling device which couples the EFT interference signal to AC power lines. Both polarities of the test voltage should be applied during compliance test and the duration of the test is 2 mins. 9.6.2 For signal lines and control lines ports: The capacitive coupling clamp shall be used for coupling the test voltage into the lines, put the signal lines into the coupling clamp, Grounding of the coaxial cable from the test generator shall be made in the vicinity of the coupling point. Both polarities of the test voltage should be applied during compliance test and the duration of the test is 2 mins. 9.6.3 For DC output line ports: It s unnecessary to test. 9.7 Test Result PASS. Page 23 of 56

Please refer to the following page. Page 24 of 56

Electrical Fast Transient/Burst Test Results Page 25 of 56

10. SURGE IMMUNITY TEST 10.1 Block Diagram of Test Setup 10.1.1 Block Diagram of the EUT AC Mains EUT Full load Notebook (EUT: UPS) 10.1.2. Surge Test Setup AC Mains EUT Surge Tester 0.8 m AC Mains 10.2 Test Standard EN61000-4-5: 2006 (Line to Line: Level, 1.0KV, Line to earth: 2.0KV) 10.3 Severity Levels Severity Level 1 2 3 4 * Open-Circuit Test Voltage KV 0.5 1.0 2.0 4.0 Special 10.4 EUT Configuration The configuration of EUT are listed in Section 3.4. Page 26 of 56

10.5 Operating Condition of EUT 10.5.1 Setup the EUT as shown in Section 10.1. 10.5.2.Turn on the power of all equipments. 10.5.3.Let the EUT work in test mode (Line mode) and measure it. 10.6 Test Procedure 1) Set up the EUT and test generator as shown on Section 10.1.2. 2) For line to line coupling mode, provide a 1.2/50us voltage surge (at open-circuit condition) and 8/20us current surge to EUT selected points. 3) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are conducted during test. 4) Different phase angles are done individually. 5) Record the EUT operating situation during compliance test and decide the EUT immunity criterion for above each test. 10.7 Test Result PASS. Please refer to the following page. Page 27 of 56

Surge Immunity Test Result 11. INJECTED CURRENTS SUSCEPTIBILITY TEST 11.1 Block Diagram of Test Setup 11.1.1 Block Diagram of the EUT Page 28 of 56

AC Mains EUT Full load Notebook (EUT: UPS) 11.1.2 Block Diagram of Test Setup 0.1 m Signal Generator EUT Ground Reference Support Power Amplifier CDN AC Mains 11.2 Test Standard EN61000-4-6: 2009 (Level2: 3V (rms), (0.15MHz ~ 80MHz)) 11.3 Severity Levels Level Field Strength V 1 1 2 3 3 10 X Special 11.4 EUT Configuration The configuration of EUT are listed in Section 3.4. 11.5 Operating Condition of EUT 11.5.1 Setup the EUT as shown in Section 11.1. 11.5.1 Turn on the power of all equipments. 11.5.1 Let the EUT work in test mode (Line mode) and measure it. 11.6 Test Procedure 1) Set up the EUT, CDN and test generators as shown on Section 11.1.2. 2) Let the EUT work in test mode and measure it. 3) The EUT are placed on an insulating support 0.1m high above a ground Page 29 of 56

reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). 4) The disturbance signal described below is injected to EUT through CDN. 5) The EUT operates within its operational mode(s) under intended climatic conditions after power on. 6) The frequency range is swept from 150KHz to80mhz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1KHz sine wave. 7) The rate of sweep shall not exceed 1.5*10-3 decades/s. Where the frequency is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value. 8) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion. 11.7 Test Results PASS. Please refer to the following page. Page 30 of 56

Injected Currents Susceptibility Test Results Page 31 of 56

12. MAGNETIC FIELD SUSCEPTIBILITY TEST 12.1 Block Diagram of Test 12.1.1 Block diagram of test setup AC Mains EUT Full load Notebook (EUT: UPS) 12.1.2 Magnetic field test setup 0.1 m Induction Coil EUT Wood Magnetic Field Tester Ground Reference Support AC Transformer AC Mains (EUT: UPS) 12.2 Test Standard EN61000-4-8: 2010, Severity Level: 10A / m 12.3 Severity Levels Level Field Strength A/m 1 1 2 3 3 10 4 30 5 100 X Special 12.4 EUT Configuration on Test The configuration of the EUT is same as Section 3.3. Page 32 of 56

12.5 Test Procedure The EUT is placed in the middle of a induction coil (1*1m), under which is a 1*1*0.1m (high) table, this small table is also placed on a larger table, 0.8 m above the ground. Both horizontal and vertical polarization of the induction coil is set on test, so that each side of the EUT is affected by the magnetic field. Also can reach the same aim by change the position of the EUT. 12.6 Test Results N.A. Page 33 of 56

13. VOLTAGE DIPS AND INTERRUPTIONS TEST 13.1 Block Diagram of Test Setup 13.1.1 Block Diagram of the EUT AC Mains EUT Full load Notebook 13.1.2 Dips Test Setup AC Mains (EUT: UPS) EUT Dips Tester 0.8 m AC Mains 13.2 Test Standard EN61000-4-11: 2004 13.3 Severity Levels Test Level %UT Voltage dip and short interruptions %UT Duration (in period) 0 40 100 60 0.5 1 5 70 30 10 25 50 * 13.4 EUT Configuration The configuration of EUT is listed in Section 3.3. Page 34 of 56

13.5 Operating Condition of EUT 13.5.1 Setup the EUT as shown in Section 13.1. 13.5.2 Turn on the power of all equipments. 13.5.3 Let the EUT work in test mode (Line mode/battery mode) and measure it. 13.6 Test Procedure 1) Set up the EUT and test generator as shown on Section 13.1.2. 2) The interruption is introduced at selected phase angles with specified duration. 3) Record any degradation of performance. 13.7 Test Result PASS. Please refer to the following page. Page 35 of 56

Voltage Dips And Interruptions Test Results Page 36 of 56

14. TEST PHOTOGRAPH 15.1 Photo of Conducted Emission Measurement 15.2 Photo of Radiation Emission Measurement Page 37 of 56

15.3 Photos of Electrostatic Discharge Test 15.4 Photos of RF Field Strength susceptibility Test Page 38 of 56

15.5 Photo of Electrical Fast Transient /Burst Test 15.6 Photo of Surge Test Page 39 of 56

15.7 Photo of Voltage Dips and Interruption Immunity Test Page 40 of 56

APPENDIX I Page 41 of 56

Page 42 of 56

Page 43 of 56

Page 44 of 56

APPENDIX II Page 45 of 56

Page 46 of 56

Page 47 of 56

APPENDIX Ⅲ Page 48 of 56

Photos of EUT Page 49 of 56

Page 50 of 56

Page 51 of 56

Page 52 of 56

Page 53 of 56

Page 54 of 56

Page 55 of 56

Page 56 of 56