Application Of Artificial Neural Network In Fault Detection Of Hvdc Converter

Similar documents
High Voltage DC Transmission 2

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Simulation Study of a Monopole HVDC Transmission System Feeding a Very Weak AC Network with Firefly Algorithm Based Optimal PI Controller

A Review Paper on Technical Data of Present HVDC Links in India

HVDC Transmission Using Artificial Neural Networks Based Constant Current and Extension Angle Control

HVDC High Voltage Direct Current

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Enhancement of AC System Stability using Artificial Neural Network Based HVDC System

ABB Power Systems AB Sweden

Reactive Power and AC Voltage Control of LCC HVDC System with Digitally Tunable Controllable Capacitors

Power Flow Control And Total Harmonic Distortion Reduction In HVDC Link Using PI And ANN Controllers

High Voltage DC Transmission Prof. S. N. Singh Department of Electrical Engineering Indian institute of Technology, Kanpur

Conventional Paper-II-2013

p. 1 p. 6 p. 22 p. 46 p. 58

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Improved Transient Compensation Using PI-SRF Control Scheme Based UHVDC For Offshore Wind Power Plant

High Voltage Direct Current Transmission

Introduction to HVDC Transmission. High Voltage Direct Current (HVDC) Transmission

AN ANN BASED FAULT DETECTION ON ALTERNATOR

Power Flow Control in HVDC Link Using PI and Ann Controllers

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Power Flow Control in HVDC-Link Using Artificial Neural Networks

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology, Kanpur

FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

The development of transmission. HVdc transmission in India. network bottlenecks. Quite a few HVdc transmission projects have been constructed

ANALYSIS OF MULTI-TERMINAL HVDC TRANSMISSION SYSTEM FEEDING VERY WEAK AC NETWORKS

Digital Fault Recorder Deployment at HVDC Converter Stations

Identification of Faults in HVDC System using Wavelet Analysis

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

3. (a) List out the advantages and disadvantages of HRC fuse (b) Explain fuse Characteristics in detail. [8+8]

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

EE 740 Transmission Lines

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Detection and classification of faults on 220 KV transmission line using wavelet transform and neural network

East-South HVDC Interconnector II, India : in commercial operation since 2003

Topics in JNTU Syllabus Modules and Sub Modules Lecture. Basic characteristics L21 T1-Ch4, T2-Ch14 Characteristics. Modification of the control

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

EH2741 Communication and Control in Electric Power Systems Lecture 2

Power Quality enhancement of a distribution line with DSTATCOM

IJEETC. InternationalJournalof. ElectricalandElectronicEngineering& Telecommunications.

Electrical Power Systems

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

Voltage and Current Waveforms Enhancement using Harmonic Filters

VSC Transmission. Presentation Overview. CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April LCC HVDC Transmission

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology Kanpur

1400 MW New Zealand HVDC Upgrade: Introducing Power Modulation Controls and Round Power Mode

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

A Novel Fuzzy Neural Network Based Distance Relaying Scheme

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

IDENTIFICATION OF POWER QUALITY PROBLEMS IN IEEE BUS SYSTEM BY USING NEURAL NETWORKS

Fractional Frequency Transmission System

Power Quality Analysis in Power System with Non Linear Load

Study of Technical Data of Present HVDC Links in INDIA and Techniques Used For System Stability in HVDC Transmission Line

Should we transform our lines to HVDC?

Modelling of the back-to-back converter between Uruguay and Brazil in A.T.P.

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Recent trends in High Voltage Direct Current (HVDC)Transmission Systems Abstract

Modelling and Simulation of Monopolar HVDC Transmission System Feeding a Strong AC Network with Firefly Algorithm based Optimal PI Controller

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

ARTIFICIAL INTELLIGENCE IN POWER SYSTEMS

Rajasthan Technical University, Kota

Control of grid connected inverter system for sinusoidal current injection with improved performance

Voltage Source Converter Modelling

Conventional Paper-II-2011 Part-1A

Introduction to HVDC in GB. Ian Cowan Simulation Engineer 12 March 2018

DESIGN CONSIDERATIONS OF ULTRA HIGH VOLTAGE DC SYSTEM

POWER QUALITY ENHANCEMENT BY DC LINK SUPPLIED INDUSTRIAL SYSTEM

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Stability Improvement for Central China System

Dynamic Performance Evaluation of an HVDC Link following Inverter Side Disturbances

Swinburne Research Bank

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

USE OF HVDC MULTI TERMINAL OPTIONS FOR FUTURE UPGRADE OF THE NATIONAL GRID

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

A DWT Approach for Detection and Classification of Transmission Line Faults

Operation of a Three-Phase PWM Rectifier/Inverter

K.K.Vasishta Kumar, K.Sathish Kumar

Decriminition between Magnetising Inrush from Interturn Fault Current in Transformer: Hilbert Transform Approach

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Long lasting transients in power filter circuits

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Implementing Re-Active Power Compensation Technique in Long Transmission System (750 Km) By Using Shunt Facts Control Device with Mat Lab Simlink Tool

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

An Introduction to the CSCT as a New Device to Compensate Reactive Power in Electrical Networks

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Protection of Extra High Voltage Transmission Line Using Distance Protection

New HVDC Interaction between AC networks and HVDC Shunt Reactors on Jeju Converter Stations

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

FAULT AND STABILITY ANALYSIS OF A POWER SYSTEM NETWORK BY MATLAB SIMULINK

Unit-II----Analysis of HVDC Converters

Volume I Issue VI 2012 September-2012 ISSN

Transcription:

Application Of Artificial Neural Network In Fault Detection Of Hvdc Converter Madhuri S Shastrakar Department of Electrical Engineering, Shree Ramdeobaba College of Engineering and Management, Nagpur, Maharashtra, India. Manisha B Gaikwad Department of Electrical Engineering, Shree Rmadeobaba College of Engineering and Management, Nagpur, Maharashtra, India. Abstract The aim of this paper is to examine the suitability of artificial neural network for fault detection of HVDC converter. As the neural network has the capability to map complex and non-linear input-output behaviour the approach is widely used for fault detection of ac-dc system. Also the neural network is used to learn patterns and relationships in data. On the basis of all advantageous features of neural network,. an attempt has been made to detect the faults in HVDC converter using artificial neural network. 1. Introduction The transmission and distribution of electrical energy started with direct current. But at that time conversion between reasonable consumer voltages and higher dc transmission voltages could only be realized by rotating dc machines. In case of ac, voltage conversion is simple with the help of ac transformer. It is a simple device with little maintenance. Further a three-phase synchronous generator is superior to a dc generator in every respect. For these reasons, ac technology was introduced in early stage in the development of electrical power system. It was soon accepted as the only feasible technology for generation, transmission and distribution of electrical energy. But still for long transmission lines ac has some limitations as the reactance of the line is inversely proportional to the power per circuit which leads to stability problems. The limitations of ac over long transmission led to the use of dc for bulk power transmission over long distance. On the other hand, artificial neural networks are nonlinear information processing devices which are built from interconnected elementary processing devices called neurons. Neural networks are the type of artificial intelligence that attempts to imitate the way a human brain works. Artificial neural networks use mathematical foundations which can be helpful to investigate input output relations of provided data and give the desired results. Hence in this paper we have tried to investigate whether the neural networks successfully detect the faults that may occur in converter or not. 2. HVDC System Model A dc link allows power transmission between ac networks with different frequencies or networks, which cannot be synchronized, for other reasons. Inductive and capacitive parameters do not limit the transmission capacity or the maximum length of dc overhead line or cable. The conductor cross section is fully utilized because there is no skin effect. The transmission of electric power for the distances less than breakeven distances ac transmission is economical but beyond the breakeven distances the dc transmission is economical. The HVDC transmission system is basically environment-friendly because improved energy transmission possibilities contribute to a more efficient utilization of existing power plants. It can be said that an HVDC system is highly compatible with any environment and can be integrated into it without the need to compromise on any environmentally important issues. Therefore we can say that the HVDC transmission is advantageous than AC in technical, economical and environmental point of view. Converter is the most important part of the HVDC system. For proper operation of HVDC system it is necessary that the converter should operate properly. 2087

Continuous operation of converter requires fast detection of faults that may occur in it and application of appropriate control actions. Therefore, this paper focuses on fault detection of HVDC converter using neural network. To detect the faults the HVDC system is designed using MATLAB software. The HVDC system model is designed for 12-pulse 1000MW. A 1000 MW (500 kv, 2kA) DC inter connection is used to transmit power from a 500 kv, 5000 MVA, 60 Hz network to a 345 kv, 10,000 MVA, 50 Hz network. The rectifier and the inverter are 12- pulse converters using two 6-pulse thyristor bridges connected in series. At both the ends, at rectifier end as well as at inverter end AC filters are installed. Filters are installed to filter out the harmonics also to provide reactive power to the converter. Rectifier and inverter are connected via two 0.5H smoothing reactor. The HVDC system model is shown in figure (1) below. 2 x 106 DC Voltage 0-2 -4 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 6000 4000 2000 DC current 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Time Figure 1: HVDC system model Results of simulation of HVDC system model shown in fig.1 are stated below. 3. Artificial Neural Network Neural Networks can operate on multidimensional data that humans may not be able to recognize due to their limited three dimensional views. Artificial neural networks are especially appropriate and powerful when used to find relationships that are difficult to describe explicitly. The training sets used for ANNs need to encompass the complete solution space. Neural networks exhibit some of the same properties that biological system exhibit. A neural network forms its own logic and stores the knowledge in its weights and instead of being given rules, the neural network learns them by training examples. Performance is improved overtime by iteratively updating the weights. ANNs appear to learn underlying rules (like input-output relationships) from given collection of representative examples. A learning algorithm refers to a procedure in which learning rules are used for adjusting the weights and biases. The purpose of learning rule is to train the network to perform some task. In this paper, back propagation training algorithm is used for fault detection purpose. Back propagation neural network is a multilayer feed forward network. Back propagation training algorithm is the most widely used ANN model for nonlinear control of a power system. Back propagation neural network has the ability to respond correctly to the input patterns that are used for training and the ability to provide good responses to the input. 2088

4. Fault Detection Scheme Fault detection of HVDC converter is based on the fact that every operation of the converter valve is associated with a set of conduction pattern of the valves. Fault detection is basically treated as a problem of pattern recognition and neural networks are extensively used where pattern recognition is needed. Therefore, by integrating the neural network algorithm with HVDC system model the faults in converter can be detected. The faults such as valve short circuit, misfire and arc through faults are discussed in this paper. Valve Short Circuit: When valve short circuit occurs high amplitude current developed on secondary of converter transformer which is conducted by a faulty valve and thereby a healthy valve which is attempted to commutate. This is avoided by fast detecting the fault and order blocking without bypassing pair before the next valve is fired. The valve short circuit is detected when the dc current goes to zero and ac current tends to increase. Here the valve short circuit fault is created in a six pulse converter bridge using breaker across valve 1 shown in figure 2. Figure 2(a): Healthy and Faulty feature plot Figure 2: Valve short circuit fault During valve short circuit fault there are disturbances in the rectifier current which is clearly visible from the rectifier current feature plot. Also the current through the valve during short circuit goes to zero which is shown in figure 3. For detecting all these three faults an M-file program is developed using back propagation training algorithm. After execution of this program we get the results for valve short circuit fault which are shown below: 2089

Figure 2(b): valve 1 current during short circuit Misfire fault: A misfire is when a valve fails to take over the conduction at its programmed instant although its voltage has the correct polarity. For a single valve misfire fault, the normal valve conduction sequence of the rectifier will be disturbed once in a cycle and reappear in every cycle if the fault is sustained. As a result, a harmonic current in rectifier side of the system frequency will be induced on dc line. Misfire fault created in a six pulse converter bridge is shown in figure 4. Figure 3(a): Healthy and Faulty feature plot Figure 3: Misfire Fault Figure 3(b): Valve current during misfire fault 2090

From fig. 5 we can see that the current through the valve during misfire fault suddenly increase and there are small disturbances in rectifier current. During this fault the normal conduction sequence is disturbed which is shown in figure 3(c). Nornal conduction sequence Faulty conduction sequence Figure 3(c): Normal and Faulty conduction sequence Arc Through Fault: Arc through fault occur when the valve fails to block the conduction at its programmed instant i.e. the valve is continuously is in ON state. Due to this reason the conduction sequence will be disturbed. Arc through fault in six pulse bridge is shown in figure 4. Figure 4(a): Healthy and Faulty feature plot Figure 4: Arc through fault Normal conduction 2091

Conduction during fault Figure 4(b): Normal and Faulty conduction The figure 4(b) shows that between the instant 1.91 and 1.95 the valve fails to block the conduction and it is continuously in ON state. Single arc through is self clearing if the causes led to it are removed. In case of persistent arc through fault differential protection scheme is used. The basic protection against all the converter faults is provided by valve group differential protection, which compares the rectified current on the valve side of converter transformer to the dc side current measured on the line side of the smoothing reactor. The differential protection is employed because of its selectivity and fast detection. The overcurrent circuit is used as a backup. The level of overcurrent required to trip must be set higher than that of the valve group differential protection to avoid tripping with faults outside the station. [2] N.Kandil, V.K.Sood, K.Khorasani,R.V.Patil, Fault Identification in an AC-DC Transmission System Using Neural Network, transaction on power system, vol.7, 2 May 1992. [3] K.S.Swarup,H.S.Chandrasekharaiah, Fault Detection and Diagnosis of Power Converter Using Artificial Neural Network, Indian institute of science, Bangalore. [4] M.Ahfaz, R.S.Parulkar, P.B.Chimankar, Operational Experiences of Chandrapur-Padghe HVDC Bipole Project. Fifteenth National Power System Conference (NPSC), IIT Bombay, December 2008.. [5] V.K.Sood, HVDC and Facts Controllers, Application of Static Converters in Power System. [6] K.R.Padiyar, HVDC Power Transmission System, second edition, 2010. [7] S Kamakshaiah and V.Kamaraju, HVDC Transmission. [8] S.N.Sivanandam, S.Sumathi, S.N.Deepa, Introduction to Neural Network, 2010. [9] Partha S Mallick, MATLAB and Simulink, Introduction to Applications, first edition, 2005. [10] Narendra Bawane, A.G.Kothari, Artificial Neural Network Based Fault Identification Of HVDC Converter synopsiumon diagnostics for electric machine,power electronic and drives,atlanta,ga,usa,24-26 August 2003 5. Conclusion. The results of different types of faults that may occur in HVDC converter have been discussed above. Fault investigation has been done using back propagation neural network based training algorithm. The back propagation neural network training algorithm is well suited for the fault detection application. The training algorithm is integrated with HVDC system to achieve the desired results. It may be concluded that the performance of back propagation training algorithm was found to be satisfactory for this application. 6. References [1] N. Bawane, A. Kothari, and D. Kothari, ANFIS Based HVDC Control and Fault Identification of HVDC Converter, HAIT Journal of science and engineering B, volume2, 2005. 2092