Fixture Holes Explanation

Similar documents
!When using electrical equipment, basic safety precautions should always be followed, including the following: AIR FOIL CLUSTER CP5371

Mostly Printed CNC Assembly Instructions

INSTRUCTION MANUAL ORDER NO. V3R MODEL V3R. Collinear Gain Vertical for MHz

NELSON STUD WELDING ACCESSORY SPECIFICATION: Stud Weld Gun Imperial Dimension Chucks

Building a vertical wobbler

V11.05 Updated May E&OE 19 RACK FRAME ASSEMBLY GUIDE

EPPA2-KIT DUAL MONITOR ARM CONVERSION

IRM 2500 Rotation plate for oval rings (operating manual)

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

TECH SHEET PEM - REF / AXIAL THREAD CLEARANCE. SUBJECT: Method for providing adequate axial thread clearance

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

Glove Box Sealing Options

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

M2 Antenna Systems, Inc. Model No: 20M6-125

Hy-gain. Method 1 : Completely assemble the antenna on the ground then hoist it into position using a setup as shown in Figure 1.

H20 Beam for Elevated Slabs Application Guide

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

make something original Mobile Workstand Shelf support (2) Caster extension (2) Leveling feet (4) Rigid caster (2)

Cable Hanging Instruction Manual

General Certificate of Secondary Education June 2012

V twin cylinder steam engine

TELEX COMMUNICATIONS, INC ALDRICH LIVE SO. MINNEAPOLIS. MN U S A. /~g-~~~~r iu IORDER NO. 337s

Klamp Trak. Instructions (39052)

Conduit measured transfer impedance and shielding effectiveness (typically achieved in the RS103 and CS114 tests)

M2 Antenna Systems, Inc. Model No: 20M5LD

PS40/PS55/PS65. Installation Instructions. Articulated TV Wall Mount Range. Issue 002

670 SCREWED FIX-IT KITS. Page WOOD SCREWS DOWEL PINS DOWELS STUDDING. Page Pages GROUP GROUP 651 EXTRACTOR GROUP 635 GROUP 650

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

FIBERLIGN (FDC8) Drop Cable Storage Bracket

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Parts & Tools. O'Cello printing and assembly instructions. o-cello.com

CP6A. 6 Band Trap Vertical 75-6m

Maximum Core Diameter A B C D Weight Body 0.39" 9.9 mm. 3/8" 9.5 mm. 5-5/8" 143 mm lb 0.47 kg lb 0.46 kg. 5-5/8" 143 mm. 3/8" 9.

GEN2 T-A Drill Inserts

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p.

KAITE KWIK CHECK Rev.01

POWER-Skru Large Diameter Concrete Screw

TECHNICAL INFORMATION

PIPE/CONDUIT SUPPORTS

MANUFACTURING TECHNOLOGY

UNIVERSITY OF THESSALY

CP6 6 Band Trap Vertical 80-6m

The model number of all Transition Plates consists of two alphanumeric clusters. The first cluster designates product type, base product and bore size

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES


Step Two. Install electrical box and wiring. Remove all three access doors and retain screws

ASSEMBLY AND ADJUSTMENT

Industrial Wall Fan SAX Installation and Maintenance Instructions

Spiderbeam Balun Construction Guide

Hullavator Gas Spring Replacement (simplified)

Installation Instructions

MANUAL STANDARD. YAGI ELEMENTS 6-20m. Rev. 1.10

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off

6U SUPERNOVA TM Structure Kit Owner s Manual

Fastener Math and Terminology

Model #SH & CH SH Pine CH Naturaline

3.0mm Rod Fixings Components

Mechanical Workshop. Module 7: Tapping and Threading. Academic Services PREPARED BY. January 2012

CMA-455 Suspended Ceiling-Tile Reinforcing Kit

Page 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications

Design a drill jig for drilling 4 holes in the following component.

INSTRUCTION MANUAL V-42R. Dual Band Collinear Gain Vertical for MHz and GENERAL DESCRIPTION

Assembly & Installation Guide (Metric)

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

(12) United States Patent

Model Series T o r s i o n

DRILL GRINDING ATTACHMENT

Physical Test Setup for Impulse Noise Testing

PO Box 1879, 515 Tucker Ave. Friday Harbor, WA Phone: (360) Fax: (360)

TELESCOPIC GATE MANUFACTURING AND INSTALLATION MANUAL.

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

b) It is assumed a suitably qualified electrical installer will make all electrical connections.

Machine Your Fishing Reel

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

Printed from MediaCat

IIHS Side Impact Outrigger

BuildPro Welding Tables

INTERMEDIATE METAL CONDUIT

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

Architectural Supports

Door Stop Bracket repair

Technical Memorandum

Camaro License Plate Frame Bracket, V8

ROOP LAL Unit-6 Drilling & Boring Mechanical Engineering Department

Dream Fabric Frame Assembly Instructions

ModulLine MP 25. System overview. 1 Chain bracket. 2 Strain relief. Chain bracket flexible. Frame bridge RS-ZL. STF Steel Fix

Referencing 0,0 position

Insertion Transducer On-line Install Instruction

BASEBALL FOUL POLES GROUND SLEEVE MOUNTED

MS2 Straight Key Kit Assembly Manual

(Issued 1 Sept. 1971) CRD-C METHOD OF TEST FOR VERIFYING MACHINES FOR USE IN FLEXURAL STRENGTH TESTS OF CONCRETE MATTRESSES

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

MOSLEY DIPOLE CONVERSION KIT MODEL TA-40-KR

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

This procedure will cover the steps to properly pack up the ARES for shipment.

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

Spotlight


Transcription:

Fixture Holes Explanation Figure 1. General description of a wire rope isolator and its components A wire rope isolator (WRI) has a simple design composed of the following components: wire rope steel cable, four bars and clamping screws. As shown in Figure 1, out of the four bars, two bars are called inner bars and the other two are called outer bars. The inner and outer bars are attached together using clamping screws, and the number of these screws depends on the model of the WRI. In order to attach the WRI to the equipment it is protecting, there are three different fixture holes options: through hole, countersunk hole (82 ), and threaded insert. To adapt the different types of fixture holes, only the inner bars fixture holes are adjusted, while the outer bars fixture holes are kept as through holes. In Figure 1, a full helical wire rope isolator is shown and it generally has four fixture holes on the top and four fixture holes on the bottom. The goal of this document is to inform the customer about the different types of fixture holes, and the consequences of choosing each one. a) Through Hole Option Figure 2. Through hole option for the fixture holes

Figure 3. Through hole option for the fixture holes with bolts used to attach the WRI to the equipment With the through hole option for fixture holes, all four bars have the same through holes. The disadvantage with this option is that due to the bolts head protruding between the two inner bars, the maximum distance the WRI is allowed to deflect in compression is reduced. This means that the maximum shock value that the WRI is able to sustain without bottoming out is reduced. So the customer should be aware that when using the through holes option the WRI cannot be used to its full shock value rating. Note also that for small loop WRI models (i.e. XX##-20), through holes are not recommended. This is because the distance between the inner bars in a small loop WRI is small, and usually will not fit a bolt long enough to provide adequate thread engagement with the equipment (at least half the diameter of the bolt). An example of the FH92-20 is shown in Figure 4, where the minimum length bolt does not fit between the inner bars. Figure 4. FH92-20 where the minimum length bolt does not fit between the inner bars

b) Hole (82 ) Option Figure 5. hole option for the fixture holes Figure 6. hole option for the fixture holes with countersunk screws used to attach the WRI to the equipment With the countersunk hole option for the fixture holes, the two inner bars are adjusted with an 82 countersunk hole. The two outer bars are kept as through holes. This fixture hole option is ideal because the it does not reduce the space between the inner bars (i.e. the maximum allowable deflection of the WRI). Although the standard countersunk hole is 82, 90 countersunk holes can also be provided.

c) Insert Option Figure 7. insert option for the fixture holes Figure 8. insert option for the fixture holes with bolts (threaded from above) used to attach the WRI to the equipment With the threaded insert option for the fixture holes, threaded inserts are added to the holes of the two inner bars. The two outer bars are kept as through holes. The equipment is attached to the WRI in the space between the bolt heads and the outer bars, as shown in Figure 8. This fixture hole option is ideal because the it does not reduce the space between the inner bars (i.e. the maximum allowable deflection of the WRI).

d) Fixture hole combinations All examples discussed above showed the same fixture hole option for both inner bars. Customers can also have a WRI with a combination of fixture hole options; i.e. inner bar 1 and inner bar 2 each having a different fixture hole option. There can be three such combinations: inner bar 1 with trough holes and inner bar 2 with threaded inserts (Fig. 9), or inner bar 1 with countersunk holes and inner bar 2 with threaded inserts (Fig. 10), or inner bar 1 with through holes and inner bar 2 with countersunk holes (Fig. 11). So depending on the interface design between the WRI and the equipment it is supporting, the customer should select any of the six fixture hole combinations that best fits the application. The six fixture hole combinations are summarized in Table 1. Figure 9. Through holes for inner bar 1 and threaded inserts for inner bar 2 Figure 10. holes for inner bar 1 and threaded inserts for inner bar 2

Figure 11. Through holes for inner bar 1 and countersunk holes for inner bar 2 Table 1. Summary of all six fixture hole combinations and their nomenclature under the imperial units system Fixture holes combinations Inner bar 2 Through Holes Inner bar 1 Holes (82 ) Through Holes T2 N/A N/A Holes (82 ) TC C2 N/A TI CI I2 Note that metric fixture holes are also possible, in which case a letter M is added in the nomenclature as shown in Table 2. Table 2. Summary of all six fixture hole combinations and their nomenclature under the metric units system Fixture holes combinations Inner bar 2 Through Holes Inner bar 1 Holes (90 ) Through Holes TM2 N/A N/A Holes (90 ) TMC CM2 N/A TMI CMI IM2