VRS-VRT SERIES. Microprocessor Controlled Servo Voltage Regulator. Power Management Instruments FROM PMI / GESS GROUP COMPANIES

Similar documents
RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

GESS Industrial UPS System. Overview

Gamatronic SVR Series kva Microprocessor Controlled Automatic Voltage Stabilizer

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

R&D TECHNICAL SPECIFI

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Power IT LV Active Filters PQFA - PQFL - PQFT

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

SENTINEL XR PLUS 5-10kVA

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

ULTRA RAPID POWER QUALITY ANALYZER

TOSHIBA International Corp

StacoDVR-5 60kVA to 6000kVA

TECHNICAL DATA SHEET B9600FXS kva

Technical Data Sheets

MAJORSINE Power Inverter

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

HEC-30/35LTA-33TDAA Rev A

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

HEC-35LTA-XXTSAA Rev A

MultiCube Multi-Function Electricity Meter. Installation and Operation

UPS Uninterruptible Power System

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

RUDOLF Digital power analyzer. Advanced Version

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

S11 Adjustable Speed Drive Engineering Specification

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Room Temperature Controllers. for heating and cooling systems

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

G-NET. 1 kva-10 kva. Rack & Tower UPS

Electronic Circuit Breaker ECONOMY REMOTE

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

Installation and Operating Instructions. Power IT Power Factor Controller RVC

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Multifunctional counter tico 772/773/774

StacoDVR-4 Digital Voltage Regulator Electromechanical three-phase kVA

HEC-70LCN-350TDAF Rev B

The Torxis Linear Servo meets the following environmental conditions:

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

HEC-45LTN-45PFAS Rev A

Room Temperature Controllers. for heating and cooling systems

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

The wireless alternative to expensive cabling...

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

75W Constant Current (700mA) LED Driver

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

Side view View from below Rear view

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Technical Data Sheet AMIK 300 / 301

Series PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10

Gutor PxW AC UPS Designed for North American Market

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

Typical Efficiency (2)

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST)(4)

The world is changing but our power is constant...

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

50W Constant Current (700mA) Dimming LED Driver

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

Room Temperature Controllers. for heating and cooling systems

HEC-100RTA-48QSCA Rev A1.0

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Typical Efficiency (3) 350 ma 90~305 Vac 57~103Vdc 216 W 91.0% EUC-240H035DV(SV)(5)

Room Temperature Controllers. for heating and cooling systems

SPECIFICATION 120W LED DRIVER

Solar Charge Controller Inverter

MYS WWSP PLUS III POWER UNIT

Operating Guide October 2006

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

RCMS460 and RCMS490 Series

DECLARATION OF CONFORMITY

Technical Specification

Digital Multifunction Instrument - Rish Master 3440

Data Sheet. RISH Master Record %THD

Types VIS and CRE. A e. Compliance with Standards. Uses. Features

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

CG-503 OPERATION MANUAL

ahead of time Static Digital Voltage Stabilisers

Technical Specification

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

SUPPLY NETWORK ANALYZER CVM-96 SERIES

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

Transcription:

RELIABLE SOLUTIONS in POWER ELECTRONICS VRS-VRT SERIES Power Management Instruments FROM PMI / GESS GROUP COMPANIES

FULL PROTECTION WITH Architecture Longterm Operational Efficiency s are RISC microprocessor controlled devices. The microprocessor controlled PWM technology prevents the unnecessary movements of servo motor and the variable transformer. Due to its mechanical architecture there are no tap changes providing perfect instant current reaction and output voltage sensitivity. This brings low risk of break downs, long lasting operation and low maintenance 2

Low Output Voltage Tolerance s operate mechanically at 100V/sec correction speed with low output voltage tolerance as low as ±1 %. Thus they are ideal solutions for protecting electronic loads. In general applications they are highly recommended for no critical loads such as lighting, and for stabilizing input voltage in buildings and factories. Energy Saving Solution The Servo Voltage Stabilizers are also ideal to be used in connection with generators where the network voltage is too low and fluctuation is high. Normally, a standalone generator starts operating below 200V, however a generator coupled with a Servo or Static Voltage Stabilizer kicks in below 165V since the corrects the network voltage down to 165V level. Regulator s correction capability within this margin would prevent unnecessary operation of generators and increase system s efficiency. Features at a glance Measuring true RMS Controlling with RISC Microprocessor Perfect static and dynamic regulation Wide input operating voltage range 130-270 VAC Electronic protection against overload and short circuit 220V ± 1% static regulation 100V/Sec regulation speed Programmable upper and lower limit for protecting over voltage Load level, input and output voltage display SAFER LOAD Since Servo Motor is set in motion with PWM technique, Servo Regulator responds to voltage spikes at optimum pulses to prevent overshoot & undershoot type corrections. As a result, the load is safer against voltage surges and short circuit current. In addition optimum corrections extend the life of the variable transformer and the regulator itself. 3

INPUT Input Voltage Regulation Range Input Voltage Operating Range Operating Frequency 50 Hz ± %5 System Input Protection Instant Voltage and Pulse Protection OUTPUT Output Voltage Overloading Regulation Speed Output THD Recovery Time Operating Technique Output Protection DIGITAL CONTROLLING PANEL (0-45kVA) Indicator and Buttons Warning Messages Viewing Measured Values Setting Output Tolerance Setting Lower Output Voltage Limit Setting Upper Output Voltage Limit DIGITAL CONTROLLING PANEL (60-600kVA) Indicator and Buttons Warning Messages Viewing Measured Values Setting Output Tolerance Stand-By Duration Output Upper Protection Voltage Output Lower Protection Voltage Regulation Voltage Sound Alarm GENERAL Total Efficiency Mechanical By-pass Electrical Noise Reduction 285-440 VAC (3 phase), 165-255 VAC (1 phase) 230-470 VAC (3 phase), 130-270 VAC (1 phase) Over Current Thermic Fuse, Instant Over Voltage Protection IEEE 587 (4500 A, 110 Joules) 380 VAC RMS ± %1 (3 Phase), 220 VAC RMS ± %1 (1 Phase) 10 Seconds at % 200 Load 100 V/sec Equal to Input THD 500 ms (165-225 VAC) RISC Microcontrolled Full Automatic Servo Controlling Short Circuit, Over Current Electronic Protection, Over and Lower Voltage Protection True RMS Digital Voltmeter, Alarm Reset Button Input High/Low, Output High/Low, Overload Warning Output, Input and Load % 1,5-2,5-3,5 5 Selectable by DIP Switch 180 190 200 210 V Selectable by DIP Switch 230 240-250 260 V Selectable by DIP Switch 2x16 LCD, Menu Scanning Button, Selecting Button, I/O Low/High, Load > %100, Motor Error, Over Temperature Mains Power and Output Voltage, Load Level % 1-5 Selectable Front LCD Panel 1 10 Sec. Selectable Front LCD Panel 230-250 VAC Selectable Front LCD Panel 180-210 VAC Selectable Front LCD Panel 220 240 VAC Selectable Front LCD Panel On Warning Messages 2 Short beep per 2 seconds Selectable Front LCD Panel >% 98 (At Full Load) Manuel Mains Line Stabilizer Selector FCC Part 15 Class B Protection Level / Color IP20 / RAL 7035 COMMUNICATION RS232 Communication (option) ENVIRONMENT Operating Temperature -10 / +50 C Relative Humidity 90% Operating Attitude Noise Level Electrical Standards * Custom production available up to 1000KVA Compatible with Windows NT, XP, Vista; Remote ON-OFF; Key parameters can be monitored over Local Area Network & Internet Max. 3000 Mt. Max. 60 db EN 50091-1 (Security) / EN 50091-2 (EMC) 4

GROUP COMPANIES PMI Elektrik Sistemleri Dis Tic. Ltd. Sti Ortadoğu Elektronik Sanayi Ltd. Şti. MANUFACTURING PLANT AND R&D Modern Keresteciler Sanayi Sitesi 1. Cad. 23. Sok. No:14 Saray / Kazan / ANKARA / TURKEY Design by: ARTVENTURE www.artventuredesign.com PMI/GESS/KARMET reserves the right to make alterations on technical specifications. PMI-2011 V.04-EN