Amp Clamp W/True RMS

Similar documents
A Clamp W/TRMS

SureTest Circuit Analyzers

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

700 Series 740 Series 760 Series 770 Series

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

600A Clamp Meters w/tightsight Display

+/- (3 PERCENT +2) AC VOLTAGE, +/- (2 PERCENT +2) DC VOLTAGE, +/- (5 PERCENT +3) RESISTANCE. User Manual, Test Lead Wrap, TP2 Test Probes

Fluke Digital Multimeters Solutions for every need

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

TABLE OF CONTENTS. Wire Termination. Tools & Supplies. Stripmaster Wire Strippers. Test & Measurement. DataComm/Networks

DL389 G2PHOENIX PRO+ True RMS Clamp Meter

G R E G E D WA R D S

USER'S MANUAL DMR-6700

TESTING & MEASUREMENT

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

1587/1577 Insulation Multimeters

Electrical and HVAC Test Tools

Testing & Measurement. FEATURED Products. SF-780 Metal Locator. NEW-CM450 True RMS Clamp Meter. NEW AM-6 Analog Multimeter

200Amp AC Clamp Meter + NCV Model MA250

User s Guide. 400A AC/DC Clamp Meter. Model MA220

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Take the current. Clamp meters available for diverse applications and conductor diameters.

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Fluke Digital Multimeters Solutions for every need

Testing & Measurement

DL389 G2PHOENIX PRO+ True RMS Clamp Meter

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

400Amp True RMS AC Clamp Meter + NCV

30XR-A Professional Digital Multimeter Users Manual

Testing & Measurement

Insulation Testers and Earth Ground Testers

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Fluke digital multimeters. Solutions for every need

400Amp True RMS AC/DC Clamp Meter Model EX613

Autoranging Multimeter Extech EX503

1507/1503. Insulation Testers. Technical Data. Features and benefits:

ELECTRICAL TESTING EQUIPMENT. CLM100 Cable Length Meter. DMEG3 Digital Insulation Resistance Tester. IRT3 Analog Insulation Resistance Tester

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

2000 A DCA/ACA CLAMP + DMM,

NOTE: Fully read and understand this manual before using this Digital Multimeter.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

AC/DC CLAMP METER USER S MANUAL

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

DM-45 Digital Multimeter

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

USER'S MANUAL DMR-4350

79/26 Series III Multimeter

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Dawson DDM190. Digital Multimeter User s Manual

1.General instructions Specifications Description...7

APPA 300 Series. The Most User-Friendly High Performance Multimeter

374/375/376 Clamp Meter. Users Manual

User Manual Digital Multimeter

LAV21 RMS (-T), LAV3 RMS (-T), LAA3 RMS (-T) Multi Channel Volt/Amp Recorders

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

netzerotools.com 374/375/376 Users Manual Clamp Meter

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

MS2030 CAT III 600 V A V AUTO RS232

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Testboy 65 Automotive-Multimeter

Analog Technologies. Multimeter 15B and17b

Fluke 170 Series True-rms Digital Multimeters

Electrical Measuring Instruments. Vol.3.

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Not for Reproduction

BENNING. CM7 Electrical Tester. Service Information

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

UAT-600 Series. amprobe.com

DDM350 Pen-Type Digital Multimeter User s Manual

DM-46 Instruction Manual

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Insulation resistance testing. A complete solution for every person.

Tested Tough. Trusted Safe.

User Guide. Digital AC/DC Clamp Meter Model 38394

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

Digital Clamp Meter. User Manual

Fluke 1587 FC/1577 Insulation Multimeters

USER'S MANUAL. ACD-16 Pro ACD-16 TRMS Pro ACD-40PQ

374/375/376 Clamp Meter

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

374/375/376 Clamp Meter

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61746 600 Amp Clamp W/True RMS Ideal Catalog Number 61746 Manufacturer Ideal Ideal, Clamp Meter, Clamp-Pro, 600 Amp With True RMS, Voltage Rating: 400 to 600VAC/DC, Resistance: 400 Ohm/4 Kohm/ 40 Kohm/400 Kohm At 1 PCT + 4 Digits Accuracy, 4 Mohm At 1.5 PCT + 4 Digits Accuracy, 40 Mohm At 3 PCT + 5 Digits Accuracy, Accuracy: Stateed Accuracy At 23 Deg C Plus or Minus 5 Deg C, Less Than 75 PCT R.H, Display 3-3/4 Digit LCD With 4000 Counts Weight per unit 1.1 (lbs/each) Product Category Cable Ties & Wraps Features Accuracy Stated Accuracy At 23 DEG C Plus Or Minus 5 DEG C, Less Than 75 PCT R.H battery 400 HR Continuous With Alkaline (), 250 HR Continuous With Alkaline (61-746) (2) 1.5 V "AAA" Batteries (NEDA R03) Includes An Isolated Battery Compartment dimensions 8 IN Height X 2.600 IN Width X 1.500 IN Depth display 3-3/4 Digit LCD With 4000 Counts Resistance 400 OHM/4 KOHM/ 40 KOHM/400 KOHM At 1 PCT + 4 Digits Accuracy, 4 MOHM At 1.5 PCT + 4 Digits Accuracy, 40 MOHM At 3 PCT + 5 Digits Accuracy Voltage Rating 600 VAC

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 s Long Product Type Special Features Manufacturer Information Brand IDEAL GTIN 00783250682478 Manufacturers Part Number 61-746 sub brand Clamp-Pro UPC 783250682478 600 AMP CLAMP W/TRUE RMS IDEAL, Clamp Meter, Clamp-Pro, 600 Amp With True RMS, Voltage Rating: 400 to 600VAC/DC, Resistance: 400 OHM/4 KOHM/ 40 KOHM/400 KOHM At 1 PCT + 4 Digits Accuracy, 4 MOHM At 1.5 PCT + 4 Digits Accuracy, 40 MOHM At 3 PCT + 5 Digits Accuracy, Accuracy: Stateed Accuracy At 23 DEG C Plus Or Minus 5 DEG C, Less Than 75 PCT R.H, Display 3-3/4 Digit LCD With 4000 Counts Clamp Meter, Ideal, Clamp-Pro, 600 Amp With True RMS, Jaw SZ: 1. Features: Measures Up To 600AAC; Non-Contact Voltage Indicator (70V - 600VAC); Tapered Jaws With Hook Tip; Auto/Manual Ranging; Data Hold; Auto Power Off; Low Battery Indicator; CAT III- 600V; 2-Year Warranty; Auto/Manual Ranging Clamp Meter; Non-Contact Voltage (70-600VAC); Measures 600 AAC Current; Measures AC/DC Voltage And Resistance; Audible Continuity; Data Hold; Auto Power Off; Low Battery Indicator; Compact Jaws For Reaching Into Tight Spaces; Electronic Overload Protection On All Ranges; 61-746 Mo Taxonomies, Classifications, and Categories Category TEST EQUIPMENT, TESTERS AND METERS Type 600 Amp With True RMS Packaging Carton 4 Weight Per each 1.05 Uses, Certifications, and Standards standard CAT III-600V, UL 61010 Listed, CE, C 12966 Temperature Rating 32 to 122 F

Test & Measurement Clamp Meter Selection Guide 700 Series 740 Series 760 Series 770 Series Clamp Meters CLAMP METER SELECTION GUIDE MEASUREMENT FUNCTIONS AC Voltage DC Voltage AC Current DC Current Resistance Audible Continuity Diode Test Capacitance Frequency FEATURES Display Type (Digital) D D D D D D D D AC Current Capacity 200 200 600 600 660 660 1000 1000 DC Current Capacity 660 1000 True RMS Auto Ranging Auto/Manual Ranging Data Hold Max Hold Peak Hold Min/Max DCA Zero Auto Power Off Non-Contact Voltage Indication Harmonics Indicator Vibration Mode Backlight Low Battery Indication High Voltage Warning Overload Protection on all Ranges Conductor Size Inches (mm) 61-702 1.3 (33) 1.3 (33) 1.5 (38) 61-746 1.5 (38) 61-763 1.4 (36) 61-765 1.4 (36) 61-773 2.0 (51) Warranty (years) 2 2 2 2 2 2 2 2 CERTIFICATIONS UL 61010 Listed CAT III, 100V/CAT IV 600V III III III III IV IV IV IV CE 61-775 2.0 (51) D-2 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance

Test & Measurement Clamp-Pro Clamp Meters 600 Amp (740 Series) Measures up to 600AAC Non-contact voltage indicator (70V-600VAC) Continuity Tapered jaws with hook tip Auto/manual ranging Data hold Auto power off Low battery indicator 2-year warranty 600A Clamp Meter w/trms 61-746 600A Clamp Meter Includes: Carrying Case and Test Leads. Specifications Range & Resolution Compact jaw for use in tight locations. N12966 Accuracy AC Current 40.00/400.0/600A 1.7% AC Voltage 400.0/600 V 1.2% DC Voltage 400.0/600 V 0.5% Resistance 400.0/4.000k/ 40.00k 400.0k/4.000M/40.00M Ω 1.0% 600V Clamp Meters 4-in-1 Test Tools (700 Series) 200AAC current capability Non-contact voltage (40-600VAC) Vibration mode to verify AC voltage Harmonics indicator Capacitance Max hold Continuity Low battery indication Integral lead storage Audible dangerous voltage warning on all ranges Auto power off Ergonomic hourglass shape Compact clamp head 2-year warranty 4-in-1 Test Tool w/trms, Backlight 4-in-1 Test Tool 61-702 Includes: Carrying Case and Silicone Test Leads. Jaw opening is 1.25 (32mm). 1000V N12966 Specifications Range & Resolution Accuracy AC Voltage 2000m/200.0/750 V 1.2% DC Voltage 2000m/200.0/1000 V 0.5% AC Current 200.0 A 3.0% Resistance 200.0/200.0k Ω 1.0% Capacitance 200.0µ F 3.0% Jaw opening is 1.3 (33mm). D-4 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance

Thermocouple Measures up to 1500 F (816 C) K-type thermocouple plugs into digital multimeter voltage jacks with 61-465 adapter 61-461 Beaded K-type Thermocouple 61-461 Thermocouple Adapter 61-465 61-465 Carrying Cases 61-010 C-90 C-290 61-445 Leather Carrying Case - for use with 61-065, 61-076, 61-085, 61-086 61-010 Small Nylon Carrying Case w/four pockets 61-445 Nylon Carrying Case - for use with all Vol-Con and Vol-Test Voltage Testers C-90 Nylon Carrying Case - for use with Digital Multimeters C-290 Carrying Case Selection Guide Accessories VOLTAGE TESTERS 160 310 340 360 480 490 610 700 740 760 770 830 61-059 61-065 61-076 61-085 61-086 61-090 61-092 61-096 61-164 61-165 61-310 61-312 61-340 61-342 61-361 61-484 61-486 61-497 61-498 61-610 61-614 61-702 61-746 61-763 61-765 61-773 61-775 61-830 61-179 Nylon Carrying Case C-50 Nylon Carrying Case C-90 Nylon Carrying Case C-230 Nylon Carrying Case C-290 Nylon Carrying Case C-700 Nylon Carrying Case C-760 Nylon Carrying Case C-770 Nylon Carrying Case 1-800-435-0705 Customer Assistance WWW.IDEALINDUSTRIES.COM D-21

Test & Measurement Replacement Parts Selection Guide METER REPACEMENT PARTS SELECTION GUIDE 090 310 340 360 480 490 600 610 700 740 760 770 790 61-096 61-310 61-312 61-340 61-342 61-361 61-484 61-486 61-497 61-498 61-605 61-610 61-614 61-702 61-746 61-763 61-765 61-773 61-775 61-795 61-797 Replacement Parts/Safety FUSES F-1 0.5A (250V) 6.35 x 38mm F-105 1A (600V) 10.3 x 35mm F-310 250mA (250V) 5 x 20mm F-312 500mA (250V) 5 x 20mm F-314 10A (250V) 5 x 20mm F-340 0.5A (500V) 6.35 x 32mm F-341 10A (1000V) 10 x 38mm F-497 440mA (1000V) 10 x 35mm F-498 11A (1000V) 10 x 38mm F-797 315mA (1000V) 5 x 32mm LA-3893 2A (600V) 6.35 x 25.4mm LA-3898 0.25A (500V) 5 x 32mm BATTERIES 61-201 1.5V (LR44) 1.5V (AA) 1.5V (AAA) 9V TEST LEADS TL-34 Leads w/pin connectors TL-56 Test leads TL-95 Test leads TL-100 Test leads w/alligator clips TL-102 Silicone test leads TL-104 Test leads w/large alligator clips TL-310 Test leads TL-795 Test leads TL-797 Test leads Safety in the Field The power demands of today s high-tech world have caused a marked increase in occurrences and levels of transient overvoltages. The International Electrotechnical Commission (IEC) has developed a safety standards model for measurement, control and laboratory use. Category I The signal level for telecommunications, electronic and other low-energy equipment with transient-limiting protection. Peak impulse transient range is 600 4,000 volts with a 30 ohm source. Category II The local level for fixed and non-fixed powered devices including appliances, lighting and portable equipment. Outlets located more than 30 feet from CAT III sources and 60 feet from CAT IV sources. Peak impulse transient range is from 600 6,000 volts with a 12 ohm source. Category III The distribution level for fixed primary feeders or branch circuits. Circuits that are separated from CAT IV sources by at least one level of transformer isolation. Peak impulse transient range is 600 8,000 volts with a 2 ohm source. Category IV (proposed) The primary supply level for the highest levels of transient overvoltage. Includes the utility service both outside and at the service entrance, service drop from the pole to the building, overhead line to remote buildings, and underground line to a well pump. Peak impulse transient range is 600 12,000 volts with less than a 1 ohm source. Visit our website for more technical product details, application support, white papers, videos and software! Meter Safety in the Field CAT I Copiers Electronic equipment Low energy equipment with transient limiting protection CAT II Appliances, PCs, TVs Outlets and long branch equipment All outlets at more than 10m (30 ft) from Category III source All outlets at more than 20m (60 ft) from Category IV source Service Entrance Service Entrance Service Entrance Meter CAT III MC Panels Underground Service Feeders and short branch circuits Distribution panel devices Heavy appliance outlets with short connections to service entrance Outbuilding Transformer Outbuilding Meter Underground Service CAT IV Exterior Transformers, Meters Outside and service entrance Service drop from pole to building Overhead line to detached building Underground line to well pump D-22 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance