Trusted 20 Channel Isolated AI/DI FTA Loop Powered

Similar documents
Trusted Power Distribution Unit MCB 24 Vdc

Trusted Versatile FTA

Trusted Speed Monitor Input FTA (SIFTA)

GV3000/SE AC Drive HP, 460V AC

Installation Instructions Space Temperature Transmitter

GV3000 AC General Purpose (Volts/Hertz) and Vector Duty Drive

SLC 500 RTD/Resistance Input Module

Bulletin 509 Three Phase Full Voltage NEMA Starters Size 9 Series A. Renewal Parts

A53106 SERIES DC-TO-DC CONVERTER

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Digital Input Module. ST-1xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

2015 RIGOL TECHNOLOGIES, INC.

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

ELECTROSURGICAL UNIT ANALYZER

BC145 SIGNAL ISOLATOR BOARD

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

CP /240-MC4 User Manual

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Explosion Proof Page/Talk Paging Amplifier

Getting started with the 2 Port Antenna Switch

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

DS1000B Series Digital Oscilloscope

CEC VIBRATION TRANSMITTER

50 Ω Dummy Load for Transmitter testing and experiments

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

DS1000E, DS1000D Series Digital Oscilloscope

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

200 Watt Passive Shunt Module

DL102 Counter Loop Amplifier

Dynamo Brushless DC Motor and GreenDriveTM Manual

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Model 9305 Fast Preamplifier Operating and Service Manual

Current Probes. User Manual

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Compact I/O RTD/Resistance Input Module

SPL EBX-IDFM SPL EBX-IDFM

PRetrans Table of contents

High Resolution Analog I/O Modules

Operating Manual. isolate501

External brake resistor AX2090-BW5x

The RF probe is of conventional design using a signal diode to convert the AC voltage to a DC voltage; it is configured as a half wave rectifier.

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

Flexible Rogowski Coil Integrator Kit with 0-5Vdc and 0-10Vdc User's Manual

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

V00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

User Guide. SIB Channel APD Array Interface Board Hamamatsu S8550 series

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

SKY LF: GHz Two-Way, 0 Degrees Power Divider

1-830 SERIES DISPLACEMENT TRANSMITTER

SCR HIGH VOLTAGE M-FRAME INTERFACE BOARD DS200SHVMG1A

OLA2 Open Loop Amplifier. Installation and Operating Manual Release May 2013

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

SKY LF: GHz High Linearity, Active Bias Low-Noise Amplifier

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

NI PXI-2532 Specifications

UM TEA1721 universal mains white goods flyback SMPS demo board. Document information

Model SPDT Power Switch Module

SIMATIC. ET 200B Distributed I/O Station. Preface, Contents. System Overview. Technical Description. Mechanical and Electrical Installation

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Model 113 Scintillation Preamplifier Operating and Service Manual

DC200A Displacement Clipper User Manual

READ THIS BEFORE ATTEMPTING TO COMBINE

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Product Manual 5202 Pulse isolator

R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DSM Dynamic Shunt

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

IMC-316P Hardware Manual for model IMC-316P-X-D

24V dc Analog Block I/O Module

DuoDrive Nixie Bargraph Kit

1715 Redundant I/O System Specifications

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

PESD5V0S2BT. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

P1-04THM Analog Input

AN1441 Application note

Safety Precautions. Copyright / Trademarks

200B Clipper Module User Manual

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

312, 316, 318. Clamp Meter. Users Manual

IF30. User's manual. Description. Table of contents IF30

IP Series DUAL POWER AMPLIFIERS

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Transcription:

ICSTT-RM294E-EN-P (PD-T8833) Trusted Trusted 20 Channel Isolated AI/DI FTA Loop Powered Product Overview The Trusted 20 Channel Isolated Analogue Input/Digital Input (AI/DI) Field Termination Assembly (FTA), Part Number: T8833, is designed to act as the main interface between a field device generating a 4 20 ma signal and the Isolated Analogue Input Module, Part Number: T8433. Features: 20 isolated input channels per FTA. Standard DIN rail compatibility. Simple installation and connection. Loop powered operation. Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5

Trusted ICSTT-RM294E-EN-P Page intentionally left blank Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5

Trusted 20 Channel Isolated AI/DI FTA Loop Powered PREFACE PREFACE In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples given in this manual are included solely for illustrative purposes. Because of the many variables and requirements related to any particular installation, Rockwell Automation does not assume responsibility or reliability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, with respect to use of information, circuits, equipment, or software described in this manual. Allen Bradley, LISTEN. THINK. SOLVE., Rockwell Automation, TechConnect, and Trusted are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. All trademarks are acknowledged. DISCLAIMER It is not intended that the information in this publication covers every possible detail about the construction, operation, or maintenance of a control system installation. You should also refer to your own local (or supplied) system safety manual, installation and operator/maintenance manuals. REVISION AND UPDATING POLICY This document is based on information available at the time of its publication. The document contents are subject to change from time to time. The latest versions of the manuals are available at the Rockwell Automation Literature Library under "Product Information" information "Critical Process Control & Safety Systems". TRUSTED RELEASE This technical manual was updated for Trusted Release 4.0. LATEST PRODUCT INFORMATION For the latest information about this product review the Product Notifications and Technical Notes issued by technical support. Product Notifications and product support are available at the Rockwell Automation Support Centre at http://rockwellautomation.custhelp.com At the Search Knowledgebase tab select the option "By Product" then scroll down and select the Trusted product. Some of the Answer ID s in the Knowledge Base require a TechConnect Support Contract. For more information about TechConnect Support Contract Access Level and Features please click on the following link: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/50871 Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 i

PREFACE Trusted 20 Channel Isolated AI/DI FTA Loop Powered This will get you to the login page where you must enter your login details. IMPORTANT A login is required to access the link. If you do not have an account then you can create one using the "Sign Up" link at the top right of the web page. DOCUMENTATION FEEDBACK Your comments help us to write better user documentation. If you discover an error, or have a suggestion on how to make this publication better, send your comment to our technical support group at http://rockwellautomation.custhelp.com ii Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered PREFACE SCOPE This manual specifies the maintenance requirements and describes the procedures to assist troubleshooting and maintenance of a Trusted system. WHO SHOULD USE THIS MANUAL This manual is for plant maintenance personnel who are experienced in the operation and maintenance of electronic equipment and are trained to work with safety systems. SYMBOLS In this manual we will use these notices to tell you about safety considerations. SHOCK HAZARD: Identifies an electrical shock hazard. If a warning label is fitted, it can be on or inside the equipment. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which can cause injury or death, property damage or economic loss. ATTENTION: Identifies information about practices or circumstances that can cause injury or death. CAUTION: Identifies information about practices or circumstances that can cause property damage or economic loss. BURN HAZARD: Identifies where a surface can reach dangerous temperatures. If a warning label is fitted, it can be on or inside the equipment. This symbol identifies items which must be thought about and put in place when designing and assembling a Trusted controller for use in a Safety Instrumented Function (SIF). It appears extensively in the Trusted Safety Manual. IMPORTANT NOTE TIP Identifies information that is critical for successful application and understanding of the product. Provides key information about the product or service. Tips give helpful information about using or setting up the equipment. Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 iii

PREFACE Trusted 20 Channel Isolated AI/DI FTA Loop Powered WARNINGS AND CAUTIONS WARNING: EXPLOSION RISK Do not connect or disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations or equivalent AVERTISSEMENT - RISQUE D EXPLOSION Ne pas connecter ou déconnecter l équipement alors qu il est sous tension, sauf si l environnement est exempt de concentrations inflammables ou équivalente MAINTENANCE Maintenance must be carried out only by qualified personnel. Failure to follow these instructions may result in personal injury. CAUTION: RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference. Caution should be exercised with regard to the use of portable communications equipment around such equipment. Signs should be posted in the vicinity of the equipment cautioning against the use of portable communications equipment. CAUTION: The module PCBs contains static sensitive components. Static handling precautions must be observed. DO NOT touch exposed connector pins or attempt to dismantle a module. iv Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered PREFACE ISSUE RECORD Issue Date Comments 2 Sep 05 Format 3 Aug 06 Termination 4 Jun 16 Rebranded and updated to incorporate IEEE standards with correction of typographical errors and also standardise the Relative Humidity Range and Operating Temperature statements in the Specification Section. 5 Dec 18 Updated Specifications table. Updated graphics in various sections. Updated header and footer to display Rockwell Automation publication number. Added trademarks statement. Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 v

PREFACE Trusted 20 Channel Isolated AI/DI FTA Loop Powered Page intentionally left blank vi Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered Table of Contents Table of Contents 1. Description... 3 2. Installation... 5 3. Associated Cable Selection... 7 4. Assembly Pinout Connections... 9 4.1. CON1 Connections... 9 4.2. TB1 Connections... 11 5. Specifications... 13 Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 1

Table of Contents Trusted 20 Channel Isolated AI/DI FTA Loop Powered Page intentionally left blank 2 Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered 1. Description 1. Description Figure 1 T8833 Layout The Trusted 20 Channel Isolated Analogue Input FTA (T8833), provides termination for a maximum of 20 input channels from various types of field devices which generate a current loop signal. When used with a Trusted TMR Isolated Analogue Input Module (T8433) each of the inputs is loop powered and individually isolated. Figure 2 below shows the configuration of a single channel. TB1 A CON1 VPOWER + 7V5 CON1 COMMON TB1 B 100 Ω CON1 VSENSE Figure 2 Single Channel Schematic The FTA is configured so that the 4-20 ma field current loop signal connects to TB1 A and the loop return connects to TB1 B. The current loop signal is then converted into a voltage by the circuit in Figure 2. This voltage is split into a 7.5 Vdc low current power supply to power the isolation amplifiers on the input module (VPOWER) and the precision 0-2 V current sense signal (VSENSE) connected to the input module. Both of these voltages are referenced to (COMMON). This means that input module operates on the loop power of the field devices. This way each field device is isolated from the other devices and from ground. Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 3

1. Description Trusted 20 Channel Isolated AI/DI FTA Loop Powered The connector linking the 20 channels on the input module to the FTA is terminated at CON1 which is a 96-way socket. A row of screw terminal connectors (TB1) are used to connect the field wiring. Unused inputs should be terminated by wiring a 24 V supply via a resistor (2K or 2K2) to the A terminal and wiring the B terminal to the associated zero volts. 4 Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered 2. Installation 2. Installation The Trusted 20 Channel Isolated AI/DI FTA (T8833) is designed to be mounted on either of the TS32 or TS35 DIN rails in the horizontal or vertical positions as required. The location of the connectors on the FTA are shown in Figure 3. Figure 3 Connector Locations Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 5

2. Installation Trusted 20 Channel Isolated AI/DI FTA Loop Powered Page intentionally left blank 6 Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered 3. Associated Cable Selection 3. Associated Cable Selection Refer to the Product Descriptions detailed below: ICSTT-RM314 (PD-TC600) Trusted I/O SmartSlot Cables 60 Channel ICSTT-RM315 (PD-TC700) Trusted I/O Companion Slot Cables 60 Channel Note: 60 channel cables are used for this FTA due to the three wire per channel connection to the input module. Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 7

3. Associated Cable Selection Trusted 20 Channel Isolated AI/DI FTA Loop Powered Page intentionally left blank 8 Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered 4. Assembly Pinout Connections 4. Assembly Pinout Connections 4.1. CON1 Connections CON1 is a 96 Way DIN 41612 socket. The connections are detailed below: Pin Row A B C 1 N/C N/C N/C 2 N/C N/C N/C 3 CH1_VPOWER CH1_COMMON CH1_VSENSE 4 CH2_VPOWER CH2_COMMON CH2_VSENSE 5 CH3_VPOWER CH3_COMMON CH3_VSENSE 6 CH4_VPOWER CH4_COMMON CH4_VSENSE 7 CH5_VPOWER CH5_COMMON CH5_VSENSE 8 CH6_VPOWER CH6_COMMON CH6_VSENSE 9 CH7_VPOWER CH7_COMMON CH7_VSENSE 10 CH8_VPOWER CH8_COMMON CH8_VSENSE 11 CH9_VPOWER CH9_COMMON CH9_VSENSE 12 CH10_VPOWER CH10_COMMON CH10_VSENSE 13 CH11_VPOWER CH11_COMMON CH11_VSENSE 14 CH12_VPOWER CH12_COMMON CH12_VSENSE 15 CH13_VPOWER CH13_COMMON CH13_VSENSE 16 CH14_VPOWER CH14_COMMON CH14_VSENSE 17 CH15_VPOWER CH15_COMMON CH15_VSENSE 18 CH16_VPOWER CH16_COMMON CH16_VSENSE 19 CH17_VPOWER CH17_COMMON CH17_VSENSE Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 9

4. Assembly Pinout Connections Trusted 20 Channel Isolated AI/DI FTA Loop Powered Pin Row A B C 20 CH18_VPOWER CH18_COMMON CH18_VSENSE 21 CH19_VPOWER CH19_COMMON CH19_VSENSE 22 CH20_VPOWER CH20_COMMON CH20_VSENSE 23 N/C N/C N/C 24 N/C N/C N/C 25 N/C N/C N/C 26 N/C N/C N/C 27 N/C N/C N/C 28 N/C N/C N/C 29 N/C N/C N/C 30 N/C N/C N/C 31 N/C N/C N/C 32 N/C N/C N/C Table 1 CON1 Connections 10 Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered 4. Assembly Pinout Connections 4.2. TB1 Connections TB1 is a row of screw terminals. Figure 3 shows how they are numbered. The connections are detailed below: Pin Service Pin Service 1 CH1_A 21 CH11_A 2 CH1_B 22 CH11_B 3 CH2_A 23 CH12_A 4 CH2_B 24 CH12_B 5 CH3_A 25 CH13_A 6 CH3_B 26 CH13_B 7 CH4_A 27 CH14_A 8 CH4_B 28 CH14_B 9 CH5_A 29 CH15_A 10 CH5_B 30 CH15_B 11 CH6_A 31 CH16_A 12 CH6_B 32 CH16_B 13 CH7_A 33 CH17_A 14 CH7_B 34 CH17_B 15 CH8_A 35 CH18_A 16 CH8_B 36 CH18_B 17 CH9_A 37 CH19_A 18 CH9_B 38 CH19_B 19 CH10_A 39 CH20_A 20 CH10_B 40 CH20_B Table 2 TB1 Connections Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 11

4. Assembly Pinout Connections Trusted 20 Channel Isolated AI/DI FTA Loop Powered Page intentionally left blank 12 Issue 5 Rockwell Automation Publication ICSTT-RM294E-EN-P

Trusted 20 Channel Isolated AI/DI FTA Loop Powered 5. Specifications 5. Specifications Field supply Power dissipation Field loop voltage 24 Vdc (nominal) 0.315 W / channel (30 ma loop current); 6.3 W total maximum Isolation Field Common Channel - Channel Circuits to chassis ground (Slider clamp / DIN rail) Field Current Loop (Per Channel) Field Loop Volt Drop at 20 ma Operating Temperature Storage Temperature Relative Humidity Operating and Storage Environmental Specifications N/A 50 V Reinforced (continuous) (1) [Type tested at 1411 Vdc for 60 s]. 50 V Reinforced (continuous) (1) 250 V Basic (fault) (2) [Type tested at 2436 Vdc for 60 s]. 2 ma to 30 ma 9.5 V 0 C to +60 C (+32 F to +140 F) -20 C to +70 C (-4 F to +158 F) 10 % 95 %, non-condensing Refer to Document ICSTT-TD003 Dimensions Height Width Depth 120 mm (4.72 in) 336 mm (13.23 in) 50 mm (1.97 in) Weight 500 g (1.1 lb) Note 1) 50 Vrms Secondary circuit derived from Mains, OVC II up to 300V. Note 2) 250 Vrms Mains circuit, OVC II up to 300V. Exposure to voltages at these levels shall be temporally constrained consistent with the system MTTR. Rockwell Automation Publication ICSTT-RM294E-EN-P Issue 5 13