Detection of Pipelines using Sub-Audio Magnetics (SAM)

Similar documents
HELICOPTER-BORNE GEOPHYSICAL SURVEY SYSTEMS

TX CONTROLLER Model EM-IP Quick Start Guide

Here the goal is to find the location of the ore body, and then evaluate its size and depth.

Data Acquisition and Processing of a Distributed 3D Induced Polarisation Imaging system

Sferic signals for lightning sourced electromagnetic surveys

Department of Communications, Marine and Natural Resources

Electromagnetic Induction

Locating good conductors by using the B-field integrated from partial db/dt waveforms of timedomain

SPREAD SPECTRUM CHANNEL MEASUREMENT INSTRUMENT

Statement of Qualifications

THE BHP AIRBORNE TEM AND MAGNETIC SURVEY (1996) over the GALMOY AREA

Technical Note TN-30 WHY DOESN'T GEONICS LIMITED BUILD A MULTI-FREQUENCY EM31 OR EM38? J.D. McNeill

Overview. GEM Systems Inc. 135 Spy Crt. Markham Ontario, L3R 5H6 Ph /20/2017 1

AIRBORNE GEOPHYSICS FOR SHALLOW OBJECT DETECTION: TECHNOLOGY UPDATE , (865) ,

AIM & THURLBY THANDAR INSTRUMENTS

Automated anomaly picking from broadband electromagnetic data in an unexploded ordnance (UXO) survey

GEONICS LIMITED LEADERS IN ELECTROMAGNETICS GEOPHYSICAL INSTRUMENTATION FOR EXPLORATION & THE ENVIRONMENT

Overview. GEM Systems Inc. 135 Spy Crt. Markham Ontario, L3R 5H6 Ph /4/2016 1

STANDARD OPERATING PROCEDURES SOP:: 2057 PAGE: 1 of 6 REV: 0.0 DATE: 07/11/03

Airborne. System. today. eter / on a unique. provides: accuracy. Highest absolute. including: cultural features. in a variety.

AIM & THURLBY THANDAR INSTRUMENTS

Grad-13. Digital Three-Axis Gradiometer.

Geology 228/378 Environmental Geophysics Lecture 10. Electromagnetic Methods (EM) I And frequency EM (FEM)

FINAL REPORT. Compact, Low-Noise Magnetic Sensor with Fluxgate (DC) and Induction (AC) Modes of Operation. SERDP Project MM-1444 JULY 2009

INSTRUMENT SYSTEMS FOR ELECTRICAL AND ELECTROMAGNETIC EXPLORATION

Abstract. Introduction

TEMPEST Geophysical Survey

On-time EM measurements: UTEM system developments

4.4 The transient electromagnetic method (TEM)

Environmental Quality Technology Program

TULLY TOWNSHIP PROVINCE OF ONTARIO

COMAPARISON OF SURVEY RESULTS FROM EM-61 AND BEEP MAT FOR UXO IN BASALTIC TERRAIN. Abstract

Final Report. Geophysical Characterization of Two UXO Test Sites. submitted to

Advanced Test Equipment Rentals ATEC (2832)

WHAT ARE WE MEASURING?

Development of a TDEM Data Acquisition System Based on a SQUID Magnetometer for Mineral Exploration

Small, Low Power, High Performance Magnetometers

Electronic Pipeline Technology

T108, GPS/GLONASS/BEIDOU Time Server

SICLOCK DCFRS Industrial Version with TTY Interface 2XV9450-1AR21

GEONICS LIMITED LEADERS IN ELECTROMAGNETICS GEOPHYSICAL INSTRUMENTATION FOR EXPLORATION & THE ENVIRONMENT

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

Old & New? INTRODUCTION. The Best Proximal Geophysical Detector Ever!

Total B Field Technologies

Principles of operation 5

On-time EM measurements: UTEM system developments

ELECTROMAGNETIC FIELD APPLICATION TO UNDERGROUND POWER CABLE DETECTION

GPS-Aided INS Datasheet Rev. 2.3

GPS-Aided INS Datasheet Rev. 2.6

Flexible AC current probes

Main Menu. Summary: Introduction:

THE FEASIBILITY OF THE AIRBORNE FLUXGATE MAGNETOMETER AS AN EXPLORATION TOOL RESULTS FROM THREE DIMENSIONAL NUMERICAL MODELLING

GOLD DIAMET RESOURCES LTD.

Nine LEDs provide feedback of transmitter operation. Induction selected One Red LED Frequency/Mode selection Four Green LEDs

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

A GUIDE SECURITY SYSTEM DESIGN QUESTIONS

Cable Identifier Reliable cable selection for energised and de-energised cables

Microseismic & Electromagnetic

KT-20 MAGNETIC SUSCEPTIBILITY AND CONDUCTIVITY METER

Covert Tunnel Detection Technologies

GEOPHYSICAL SURVEY REPORT AIRBORNE MAGNETIC AND HELITEM SURVEY SUDBURY AREA PROJECT NORTH AMERICAN PALLADIUM LTD.

Radiodetection Pipeline Products

Ariadna Instruments. Power cable identifier & LV live network phase and feeder identifier

DEVELOPMENT OF A NEW OPTICALLY PUMPED POTASIUM MAGNETOMETER

A i r G R AV & M A G - a n a i r b o r n e g r a v i t y & AirGRAV&MAG is a highly. and high resolution magnetometer

Radar Methods General Overview

Holiday Detector mod. 284/35KV

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

I p = V s = N s I s V p N p

A COMPARISON OF ELECTRODE ARRAYS IN IP SURVEYING

Tx II Transmitter 3600 W Instruction Manual

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

UTILITY LOCATING EQUIPMENT

Wireless Neural Loggers

Report. Mearns Consulting LLC. Former Gas Station 237 E. Las Tunas Drive San Gabriel, California Project # E

ATLANS-C. mobile mapping position and orientation solution

LOGISTICS AND PROCESSING REPORT GEOTEM Airborne Electromagnetic and Magnetic Survey RENABIE WAWA, ONTARIO. Project No

SGD-EEM «MEDUSA» GEOELECTRICAL MULTIFUNCTION RECEIVER

ISA Series. resistance welding. Mid-Frequency Inverter Resistance Welding Control

Chapter 4 DGPS REQUIREMENTS AND EQUIPMENT SELECTION

SA-320 Installation Guide SA-320. Installation Guide. Date: June, 2007 Version: 2.2. All Rights Reserved

Dartmouth College LF-HF Receiver May 10, 1996

Picture 1 PC & USB Connection

XMT-G (GPS Synchronized) TRANSMITTER CONTROLLER MANUAL

A higher performance product designed for safer excavating.

Decoding Galileo and Compass

T200, PTP/IEEE 1588 Grandmaster Clock and

Signal Characteristics

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

Geophysical Survey Rock Hill Bleachery TBA Site Rock Hill, South Carolina EP-W EPA, START 3, Region 4 TABLE OF CONTENTS Section Page Signature

New INTERMAGNET Fluxgate Magnetometer

MARINE GEOPHYSICAL PROVE-OUT AND SURVEY AT FLAG LAKE BOMBING RANGE BARKSDALE AIR FORCE BASE, LOUISIANA

Section 2. AC Circuits

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5

FINAL Geophysical Test Plot Report

9.4. Synchronization:

SPEEDBOX Technical Datasheet

Stratagem EH4 Geometrics, Inc.

Transcription:

Gap Geophysics Australia Pty Ltd. Detection of Pipelines using Sub-Audio Magnetics is a patented technique developed by Gap Geophysics. The technique uses a fast sampling magnetometer to monitor magnetic and electromagnetic signals simultaneously. The technique has been under development for over 15 years and has various applications including mineral exploration, unexploded ordnance detection and utility mapping. For the mapping of pipes, it is necessary to transmit electrical current through a conductor in the pipe at a known alternating frequency and with a regulated current using a geophysical transmitter which in turn is synchronized to a fast sampling magnetometer. Synchronization is usually achieved by synchronizing both instruments with GPS timing pulses. Positioning and navigation is achieved with GPS. The alternating current transmitted through the pipe produces an alternating electromagnetic field which is detected by the magnetometer as it traverses across the pipe. The data recorded by the magnetometer is processed and the magnetic and electromagnetic signals are separated. The position of the pipe can then be determined by the amplitude and polarity of the electromagnetic field. In low latitude areas such as near the Equator, total field magnetometers are not suitable for this application. Our recommendation would be to use the vertical component of the magnetic field as may be measured by a fluxgate magnetometer. In this situation, the anomaly produced would indicate a dipolar shaped anomaly on the survey profile across the pipe with a point of inflection immediately over the pipe. The amplitude of the anomaly decreases proportionally with distance from the pipe (1/r) and is therefore a direct indication of the depth to the conductor in the pipe (assuming constant current). This technique is dependent on an ability to transmit current through the pipe ie it is necessary to gain access to a conductor in the pipe and also to achieve an earth return. The following pages provide some background information on the SAM technology.

is a high definition patented technique which measures both magnetic and electrical properties of the earth from a single survey. Field Methodology: SAM has two main modes of operation Galvanic and Electromagnetic. Both modes employ a geophysical transmitter to produce an energising field. SAM Galvanic surveys are similar to the MMR technique where current is transmitted through a pair of grounded electrodes. The electrical current will channel along relative conductors in the ground. SAM EM surveys use a transmit loop and rely on electromagnetic induction to produce secondary fields in buried conductors. The transmitter produces a time domain waveform typically in the sub-audio frequency range of 1-20 Hz. A rapid sampling total field magnetometer acquires both the spatial and induced temporal fields whilst continuously traversing the ground. The signals are separated by digital filtering. Low pass filtering of the recorded data yields the spatially varying magnetic field. High pass filtering extracts the artificially induced modulation. Signal processing extracts parameters of interest including, Total Magnetic Intensity (TMI), Total Field Magnetometric Resistivity (TFMMR), Total Field Magnetometric Induced Polarisation (TFMMIP) and Total Field Electromagnetic Induction (TFEMI). Benefits of SAM include: Simultaneous acquisition of physically independent data sets Continuous sampling enables cost-effective, high spatial resolution surveys Use of a magnetic sensor allows a point measurement as opposed to a volume measurement permitting higher definition than conventional resistivity and IP techniques. B-field measurement is superior to db/dt for late time EM decays. TMI EQMMR

Applications to utility mapping SAM response from a sewerage pipe at 2.5m depth SAM can be used for mapping underground utilities such as pipes and cables by channeling electrical current through the item to be mapped. This technique uses the Gap LPTX battery powered transmitter controlled by the GAP SAM-2 transmitter controller. The GAP TM-6 magnetometer is used to record the total magnetic intensity at 1200 samples per second. Navigation and positioning is performed by the TM-6 s proprietary software in combination with DGPS. Use of a magnetometer in built-up areas is often difficult because of electromagnetic interference from 50/60 Hz mains power. The bandwidth of the Cs sensor enables the magnetometer to track the alternating electromagnetic fields. By using a transmit frequency which is a sub-multiple of mains frequencies, mains interference can be effectively removed by signal stacking. The result is a clean accurate signal which is not degraded by magnetic or electromagnetic interference.

GAP TM-6 Magnetometer Controller The TM-6 magnetometer controller is the culmination of over 25 years experience in high definition magnetometry and is the first magnetometer designed to meet the demanding requirements of the technique. It is the ultimate instrument for rapid sampling magnetics from ground level multi-sensor UXO applications to airborne magnetics and EM systems. controls up to four Cs vapour sensors sample rates of 1200, 2400, 4800 and 9600 samples per second designed for 50/60 Hz noise rejection absolute measurement error 0.043 nt @50000nT magnetometer data range 30000-90000 nt RMS noise (1200, 2400, 4800, 9600 sps) 0.02, 0.04, 0.12, 0.58 nt 8 serial ports GPS data and strobe input (precise synchronisation to GPS strobe) fluxgate magnetometer input for compensation systems laser altimeter interface robotic total station interface TM-6Ui user interface has built-in navigation and positioning

GAP SAM-2 Transmitter Controller Controls Zonge GGT-10, GGT-30 geophysical transmitters Precise synchronisation with GPS timing strobes (accurate to 1µs) Synchronisation updates every second no drift unless satellite lock is lost for an extended period Digital display provides operator with GPS status and alarms if satellite lock is lost. Frequency modes Binary mode 0.125 to 128 Hz 50 Hz mode 3.125 to 100 Hz 60 Hz mode 1.875 to 120 Hz. (50/60 Hz modes provide frequencies which are submultiples of mains power to assist in rejection of mains interference) Duty cycles 12.5%, 25%, 50%, 100% Outputs BNC analogue to monitor signal RS-232 digital to monitor GPS Internal rechargeable battery