HA1SV W DC/DC Power Modules

Similar documents
V48SC3R320 66W DC/DC Power Modules

H80SV12017 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,200W APPLICATIONS

Delphi Series Q48SK, Quarter Brick Family DC/DC Power Modules: 36~75V in, 12V/18A out, 216W

Q54SJ W DC/DC Power Modules FEATURES. Q54SJ12058, 700W Quarter Brick DC/DC Power Modules: 40~60Vin, 12.2V/ 57.4A out OPTIONS APPLICATIONS

TBD. Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W FEATURES OPTIONS APPLICATIONS

H36SA W DC/DC Power Module

V48SC W DC/DC Power Modules

Delphi Series V48SR, 1/16 th Brick 66W

Delphi Series H48SC3R325, 85W Half Brick Family DC/DC Power Modules: 48V in, 3.3V/25A out

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W

V36SE12005 FEATURES. Delphi Series V36SE, 1/16 th. Brick DC/DC Power Modules: 18~75Vin, up to 60W OPTIONS APPLICATIONS

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

Delphi Series S36SA, 25W Family DC/DC Power Modules: 18Vin to 60Vin, 3.3V/8A out

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.8V/40A out

Delphi Series Q36SR, Quarter Brick 204W DC/DC Power Modules: 18V~75Vin,12V, 17Aout

V36SE12004 FEATURES. Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W OPTIONS APPLICATIONS

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

Delphi Series H48SA, 150W Half Brick Family DC/DC Power Modules: 36~75V in, 48V/3.2A out

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 12V/10A out

Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 15V/4A out

Delphi Series T48SR, 1/32 Brick Family DC/DC Power Modules: 36~75V in, 5V/5A out, 25W FEATURES OPTIONS APPLICATIONS

Delphi Series S48SP, 35W 1x1 Brick DC/DC Power Modules: 48V in, 5V/7A out

Delphi Series Q48SQ, Quarter Brick Family DC/DC Power Modules: 36~75V in, 12V/18A out, 216W

Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W

` FEATURES. Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.0V/50A out OPTIONS APPLICATIONS

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 5V/20A out

Delphi Series H48SA, 450W Half Brick Family

Delphi Series Q48SQ, Quarter Brick Family DC/DC Power Modules: 36~75V in, 12V/33A out, 400W

Delphi S36SE, 25W 1x1 Brick Series DC/DC Power Modules: 36~75V in, 12V/2A out

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

S24SP series 60W Single Output DC/DC Converter

Delphi Series E48SP Eighth Brick Family DC/DC Power Modules: 48V in, 12V/20A out

S24SE/S24DE series 15W Single/Dual Output DC/DC Converter

H48SC W DC/DC Power Module

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out

E48SP W DC/DC Power Modules

Delphi Series E36SC3R3, Eighth Brick 116W DC/DC Power Modules: 18V~75Vin, 3.3V, 35Aout

Delphi Series T48SR, 1/32 Brick Family DC/DC Power Modules: 36~75V in, 3.3V/7.5A out, 24.75W

Delphi Series V48SR, 1/16 th Brick 65W

Delphi Series E48SP3R340, 1/8 th Brick 132W DC/DC Power Modules: 48V in, 3.3V, 40A out

Delphi D12S2R550 Non-Isolated Point of Load

Delphi Series E36SC120, Eighth Brick 108W DC/DC Power Modules: 18V~75Vin, 12V, 9Aout

H80SV12008 * * FEATURES. Delphi Series H80SV, Half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,200W APPLICATIONS

Encapsulated Type. Page I-III. Page 1-15 Open-Frame Type. S36SE3R305 Datasheet

H80SV24004 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,100W APPLICATIONS

Delphi DNT04, Non-Isolated Point of Load

H80SV48002 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12 Vout,100W APPLICATIONS

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

Delphi Series E48SC12010, Eighth Brick Family DC/DC Power Modules: 48V in, 12V/10A out

H80SV12017 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,200W APPLICATIONS

H80SV15007 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,100W APPLICATIONS

Delphi series DNT12 Non-Isolated Point of Load DC/DC Power Modules: 8.3~14Vin, 0.75~5.0Vo, 3A

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 12V/10A out

PM24S/DR24S series 60W Single Output DC/DC Converter

Delphi D12S300-1 Non-Isolated Point of Load

Delphi series DNT12 Non-Isolated Point of Load DC/DC Power Modules: 8.3~14Vin, 0.75~5.5Vo, 3A

E54SJ12040 FEATURES OPTIONS APPLICATIONS. E54SJ /8 Brick DC/DC Regulated Power Module 40~60V in, 11.8V/40.7A out, 480W. 480W DC/DC Power Modules

PM24S/PM24D series 30W Single/Dual Output DC/DC Converter

Delphi Series Filter Module - FL75L05 A 75Vdc input, 5A current Rating

S24SP05012 series 60W Single Output DC/DC Converter

S24SP24003 series 60W Single Output DC/DC Converter

Delphi Series Filter Module - FL75L10A 75Vdc max input, 10A max output current

S24SP12004 series 40W Single Output DC/DC Converter

FL75R10A Filter Module 75Vdc Input Maximum, 10A Maximum

Delphi DNL, Non-Isolated Point of Load

Delphi ND Series Non-Isolated Point of Load

Delphi DNS, Non-Isolated Point of Load

Delphi NE Series Non-Isolated Point of Load DC/DC Modules: 3.1~13.8Vin, 0.59V-5.1Vout, 3Aout

Delphi DNM, Non-Isolated Point of Load

Delphi DNL, Non-Isolated Point of Load

Delphi NE Series Non-Isolated Point of Load

Delphi DCT, Non-Isolated Point of Load

Delphi DNM series Non-Isolated Point of Load

D12S1R880D FEATURES. D12S1R880D, Non-Isolated, Power Block DC/DC Power Modules: 7.0~13.2Vin, 0.6V~1.8V/80A, 2.5V/70A, 3.3V/65A APPLICATIONS

Delphi DNL, Non-Isolated Point of Load

D12S1R830, Non-Isolated, Power Block

Delphi DNM series Non-Isolated Point of Load

SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W

48V Output AC/DC Converter Box Type Package

0RCY-F0S10x Isolated DC-DC Convert

Networking Computers and Peripherals Telecommunications

PACSR V Output AC/DC Converter, Module Package

AA SERIES (1 x 1 Package) Up to 30 Watt DC-DC Converter

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

500 WATT MXW SERIES DC/DC CONVERTERS

AA SERIES (1 x 1 Package) Up to 10 Watt DC-DC Converter

PXD30-xxWS-xx-Single Output DC/DC Converters

MIW3000 Series EMI. 5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Cool Power Technologies

360 WATT MTW SERIES DC/DC CONVERTERS

(DOSA) VDC, 5.5 A.

OVP 2:1. Wide Range. Protection

24 Austin Lynx TM : Non-Isolated DC-DC Power Modules 20Vdc 30Vdc input; 5.0 Vdc to 15 Vdc output; 70W Output Power

YNV12T05 DC-DC Converter Data Sheet VDC Input; VDC 5 A

EQD075 Series (Eighth-Brick)DC-DC Converter Power Modules 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W

150 WATT QSW DC/DC CONVERTERS

SRPE-50E1A0 Non-Isolated DC-DC Converter

Negative voltage step, 25% to 75% load dynamic, 0.1A/us slew rate. Vin=110/220Vac, Io=10, peak to peak, 20MHz bandwidth

PXD10-Single Output DC/DC Converter

PRODUCT OVERVIEW. APPLICATIONS: Distributed Power Architectures Mobile telecommunication Industrial applications Battery operated equipment

Transcription:

HA1SV12008 100W DC/DC Power Modules FEATURES High efficiency : 86% @110Vin full load Size:61.0mm*57.9mm*12.7mm(2.4 *2.28 *0.5 ) Industry standard pin out and footprint Fixed frequency operation Input UVP/ OVP Hiccup output over current protection (OCP) Hiccup output over voltage protection (OVP) Output current limited protection(ocl) Auto recovery OTP Monotonic startup into normal 3000V isolation and reinforce insulation No minimum load required ISO 9001, TL 9000, ISO 14001, QS9000, OHSAS18001 certified manufacturing facility EN50155,EN61373 EN60950-1:2006,UL60950-1,CSA-C22.2 Delphi Series HA1SV12, half Brick Family DC/DC Power Modules: 53~154V in, 12V/8.3A out, 100W The Delphi Module HA1SV12008PRFA, half brick, 53~154V input, single output, isolated DC/DC converter is the latest offering from a world leader in power system and technology and manufacturing Delta Electronics, Inc. This product provides up to 100 watts power in an industry standard footprint and pin out. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performances, as well as extremely high reliability under highly stressful operating conditions. The HA1SV12008PRFA offers more than 84% high efficiency at 5A load in all input voltage range. APPLICATIONS Railway /Transportation system DATASHEET P1

TECHNICAL SPECIFICATIONS PARAMETER NOTES and CONDITIONS HA1SV12008PRFA Min. Typ. Max. Units 1. ABSOLUTE MAXIMUM RATINGS 1.1 Input Voltage EN50155 53 110 154 Vdc 1.2 Input surge withstand <100ms 250 Vdc 1.3 Operating Ambient Temperature -40 100 C 1.4 Storage Temperature -55 125 C 1.5 Input/Output Isolation Voltage reinforce 3000 Vrms 2. INPUT CHARACTERISTICS 2.1 Operating Input Voltage 53 110 154 Vdc 2.2 Input Under-Voltage Lockout 2.2.1 Turn-On Voltage Threshold 49 51 53 Vdc 2.2.2 Turn-Off Voltage Threshold 46 48 50 Vdc 2.3 Input Over-Voltage Lockout 2.3.1 Turn-On Voltage Threshold 154 158 162 Vdc 2.3.2 Turn-Off Voltage Threshold 158 162 166 Vdc 2.4 Maximum Input Current Full Load, 53Vin 2.2 2.3 A 2.5 No-Load Input Current Vin=110V, Io=0A 18.3 30 ma 2.6 Off Converter Input Current Vin=110V 17.1 30 ma 2.7 Input Reflected-Ripple Current(pk-pk) Vin=110V, Io=full load,cin=150uf/400v 35 ma 3. OUTPUT CHARACTERISTICS 3.1 Output Voltage Set Point Vin=110V, Io=0, Tc=25 C 11.8 12 12.2 Vdc 3.1.1 Load regulation Vin=110V, Io=Io min to Io max ±0.05 ±0.2 % 3.1.2 Line regulation Vin=53V to154v, Io=full load ±0.01 ±0.2 % 3.1.3 Temperature regulation Vin=110V, Tc= min to max case temperatrue ±0.004 ±0.007 %/ 3.2 Output Voltage Ripple and Noise 5Hz to 20MHz bandwidth 3.2.1 Peak-to-Peak Full Load, 50 100 mv 3.2.2 rms Full Load, 10 20 mv 3.3 Operating Output Current Range 0 8.3 A 3.4 Output DC Current-Limit Inception 8.7 9.4 10.1 A 4.DYNAMIC CHARACTERISTICS 4.1 Output Voltage Current Transient 110V, 0.1A/µs 4.1.1 Positive Step Change in Output Current 50% Io.max to 75% 300 600 mv 4.1.2 Negative Step Change in Output Current 75% Io.max to 50% 300 600 mv 4.2 Turn-On Transient 4.2.1 Start-Up Time, From On/Off Control 55 100 ms 4.2.2 Start-Up Time, From Input 50 80 ms 4.2.3 Rise time(vout from 10% to 90%) 25 50 ms 4.3 Maximum output capacitor 680 µf 5. EFFICIENCY 5.1 100% Load Vin=110V 86 % 5.2 60% Load Vin=110V 86.1 % 6.ISOLATION CHARACTERISTICS 6.1 Input to Output 3000 Vrms 6.2 Input to base 1500 Vrms 6.3 Output to base 500 Vrms 6.4 Isolation Resistance 10 MΩ 7. FEATURE CHARACTERISTICS 7.1 Switching Frequency 300 khz 7.2 ON/OFF Control, Negative Remote On/Off logic 7.2.1 Logic High (Module On) 3 5 V 7.2.2 Logic Low (Module Off) 0 1 V 7.3 Output Voltage Trim Range -10 10 % 7.4 Output Over-Voltage Protection Over full temp range; % of nominal Vout 110 120 130 % 8 GENERAL SPECIFICATIONS 8.1 MTBF 1,302 hours 8.2 Weight With heat spreader 80 grams 8.3.Over-Temperature Shutdown ( NTC resistor ) Refer to Figure 18 for NTC resistor location 118 C (T A=25 C, Natural convection, Vin=110Vdc, nominal Vout unless otherwise noted; P2

ELECTRICAL CHARACTERISTICS CURVES ef f i ci ency 100. 00% 90. 00% 80. 00% 70. 00% 60. 00% 50. 00% 40. 00% 30. 00% 20. 00% 10. 00% 0. 00% 0 1 2 3 4 5 6 7 Out put cur r ent ( A) 110V 53V 154V power l oss 20. 0 18. 0 16. 0 14. 0 12. 0 10. 0 8. 0 6. 0 4. 0 2. 0 0. 0 0 1 2 3 4 5 6 7 8 9 Out put cur r ent ( A) 53V 110V 154V Figure 1: Efficiency vs. load current for 66,110and 160 input voltage at 25 C. Figure 2: Power dissipation vs. load current for 36V, 48V, and 75V input voltage at 25 C. Figure 3: Turn-on transient at zero load current) (20ms/div). Top Trace: Vout; 5V/div; Bottom Trace: ON/OFF input: 2V/div. Figure 4: Turn-on transient at full load current (20ms/div). Top Trace: Vout: 5V/div; Bottom Trace: ON/OFF input: 2V/div. Figure 5: Turn-on transient at zero load current (10ms/div). Top Trace: Vout; 5V/div; Bottom Trace: input voltage: 50V/div. Figure 6: Turn-on transient at full load current (10ms/div). Top Trace: Vout; 1V/div; Bottom Trace: input voltage: 50V/div. P3

ELECTRICAL CHARACTERISTICS CURVES Figure 7: Output voltage response to step-change in load current (50%-75%-50% of full load; di/dt = 0.1A/µs). Bottom Trace: Vout;100mV/div; Time: 1ms/div Figure 8: Output voltage response to step-change in load current (50%-75%-50% of full load; di/dt = 2.5A/µs). Bottom Trace: Vout; 50mV/div; Time: 1ms/div Vo(+) scope r Resistor load Vo(-) Figure 9: Output voltage noise and ripple measurement test setu out put vol t age( V) 14 12 10 8 6 4 2 OCL 0 0 1 2 3 4 5 6 7 8 9 10 Out put cur r ent ( A) Figure 10: Output voltage ripple at nominal input voltage and max load current (10 mv/div, 2us/div) Bandwidth: 20 MHz. Figure 11: Output voltage vs. load current showing typical current limit curves and converter shutdown points. P4

DESIGN CONSIDERATIONS Input Source Impedance Test Result: At T = +25 C, Vin = 110V and full load blue line is peak mode; The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few μh, we advise 150μF electrolytic capacitor (ESR < 0.7 Ω at 100 khz) mounted close to the input of the module to improve the stability. dbμv 80.0 70.0 60.0 50.0 Limits 55022MAV 55022MQP Layout and EMC Considerations 40.0 Transducer 8130 Delta s DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta s technical support team. Below is the reference design for an input filter tested with HA1SV12008PRFA to meet class A in CISSPR 22. Schematic and Components List C121=120Uf/400V Figure 12 EMC test schematic C123,C124,C127,C132 =220pF/275VAC C128,C129,C130,C131=2200pF/300VAC C122,C125,C126=0.47uF/250V T1=3.4mH, common choke R110,R111,R112,E113,R114=300kohm/1206 30.0 20.0 10.0 0.0 150 khz 1 MHz 10 MHz 30 MHz Safety Considerations Figure 13 EMI test positive line Traces PK+ AV The power module must be installed in compliance with the spacing and separation requirements of the end-user s safety agency standard, i.e., UL60950-1, CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd : 2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the system in which the power module is to be used must meet safety agency requirements. Basic insulation based on 110 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV. When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 110 Vdc, for the module s output to meet SELV requirements, all of the following must be met: The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. A SELV reliability test is conducted on the system where the module is used, in combination with the module, to ensure that under a single fault, hazardous voltage does not appear at the module s output. P5

When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 10A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current. Remote On/Off The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low. Remote on/off can be controlled by an external switch between the on/off terminal and the Vi (-) terminal. The switch can be an open collector or open drain. For negative logic if the remote on/off feature is not used, please short the on/off pin to Vi (-). For positive logic if the remote on/off feature is not used, please leave the on/off pin to floating. Soldering and Cleaning Considerations Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta s technical support team. FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will shut down, and will try to restart after shutdown(hiccup mode). If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected. Over-Voltage Protection The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. If this voltage exceeds the over-voltage set point, the protection circuit will constrain the max duty cycle to limit the output voltage, if the output voltage continuously increases the modules will shut down, and then restart after a hiccup-time (hiccup mode). Over-Temperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the module will shut down.the module will restart after the temperature is within specification. Figure 14: Remote on/off implementation Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, connect an external resistor between the TRIM pin and SENSE(+) pin or SENSE(-) pin. The TRIM pin should be left open if this feature is not used. For trim down, the external resistor value required to obtain a percentage of output voltage change % is defined as: 10 * Vnom *(1 ) Rtrim down K Vnom Vnom *(1 ) Ex. When Trim-down -10% (12V 0.9=10.8V) 10 *12* 0.9 Rtrim down K 90 K 12 12* 0.9 For trim up, the external resistor value required to obtain a percentage output voltage change % is defined as: Vnom ( 1 ) 2.5 *120 Rtrim up 10 K Vnom 2.5 Ex. When Trim-up +10% (12V 1.1=13.2V) 12 (1 0.1) 2.5 *120 Rtrim up 10 418 K 12 2.5 The output voltage can be increased by both the remote sense and the trim, however the maximum increase is the larger of either the remote sense or the trim, not the sum of both. P6

The output voltage can be increased by both the remote sense and the trim, however the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Pin function The pin was difine as follow in figure 20,we will explain the pin function: +IN, -IN. DC voltage inputs. Gate IN. The Gate IN pin on a driver module may be used as a logic enable/disable input.when Gate IN is pull low (<1V,referenced to Vin ),the module is turned off. when Gate IN is floating (open collector),the module is turned on.the open circuit voltage of Gate in PIN is less than 5V. Gate OUT. The pulsed signal at the Gate OUT pin of a regulating driver module is used to synchronously drive the surge circuit in order to meet the RIA12 surge needed. If you don t used this function, please floating it. +OUT, -OUT. DC voltage outputs. T(TRIM). Provides fixed or variable adjustment of the module output. Trimming down. Allows output voltage of the module to be trimmed down, with a decrease in efficiency.ripple as a percent of output voltage goes up and input range widens since input voltage dropout(loss of regulation) moves down Trimming up. Reverses the above effects. -Sense,+Sense. Provides for locating the point of optimal voltage regulation external to the converter. THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. Thermal Testing Setup Delta s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25 ). FANCING PWB AIR VELOCITY AND AMBIENT TEMPERATURE SURED BELOW THE MODULE AIR FLOW PWB MODULE 50.8(2.00") Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Thermal Derating Figure 15: Wind tunnel test setup Heat can be removed by increasing airflow over the module. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. P7

THERMAL CURVES THERMAL CURVES Figure 16: * temperature measured point Figure 17: Output current vs. ambient temperature and air velocity @Vin=110V(Either Orientation, airflow from input to output,with heat spreader) THERMAL CURVES Figure 18: NTC resistor location P8

LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE Figure 19 recommended temperature profile for lead-free wave soldering MECHANICAL DRAWING(BASEPLATE) Figure 20 the pin function and mechanical drawing P9

MECHANICAL DRAWING(WITHOUT MOUNTING HOLE) Figure 20 the pin function and mechanical drawing DIMENSIONAL TOLERANCE X ±0.3mm x.x ±0.2mm x.xx ±0.1mm P10

PART NUMBERING SYSTEM H A1 S V 12 008 N N F A Form Input Number of Product Output Output ON/OFF Pin Option Code Factor Voltage Outputs Series Voltage Current Logic Length H - Half Brick 110-53V~154V S Single V- Series 12-12V 008-8.3A N Negative N - 0.145 R - 0.170 M - SMD pin F - RoHS 6/6 (Lead Free) A Baseplate H without mounting hole Number P - Space - RoHS5/6 Positive MODEL LIST MODEL NAME INPUT OUTPUT EFF @ 100% LOAD HA1SV12008PRFA 53V~154V 2.2A 12V 8.3A 86% HA1SV12008PRFH 53V~154V 2.2A 12V 8.3A 86% Default remote on/off logic is negative and pin length is 0.170 For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office. For modules with through-hole pins and the optional heatspreader, they are intended for wave soldering assembly onto system boards; please do not subject such modules through reflow temperature profile. CONTACT: www.deltaww.com/dcdc USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Email: dcdc@deltaww.com Europe: Phone: +31-20-655-0967 Fax: +31-20-655-0999 Asia & the rest of world: Telephone: +886 3 4526107 ext 6220~6224 Fax: +886 3 4513485 WARRANTY Delta offers a five (5) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. P11