We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Similar documents
Design of Self-Tuning Fuzzy PI controller in LABVIEW for Control of a Real Time Process

Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller

Development of a Fuzzy Logic Controller for Industrial Conveyor Systems

A PLC-based Self-tuning PI-Fuzzy Controller for Linear and Non-linear Drives Control

Tuning Of Conventional Pid And Fuzzy Logic Controller Using Different Defuzzification Techniques

Comparison of Adaptive Neuro-Fuzzy based PSS and SSSC Controllers for Enhancing Power System Oscillation Damping

Performance Analysis of Fuzzy Logic And PID Controller for PM DC Motor Drive Khalid Al-Mutib 1, N. M. Adamali Shah 2, Ebrahim Mattar 3

CHAPTER 4 FUZZY LOGIC CONTROLLER

Fuzzy Controllers for Boost DC-DC Converters

AN APPROACH TO IMPROVE THE PERFORMANCE OF A POSITION CONTROL DC MOTOR BY USING DIGITAL CONTROL SYSTEM

A new fuzzy self-tuning PD load frequency controller for micro-hydropower system

OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROLLERS

Design and Development of an Optimized Fuzzy Proportional-Integral-Derivative Controller using Genetic Algorithm

CHAPTER 4 LOAD FREQUENCY CONTROL OF INTERCONNECTED HYDRO-THERMAL SYSTEM

Intelligent Methods for Tuning of Different Controllers

CHAPTER 4 AN EFFICIENT ANFIS BASED SELF TUNING OF PI CONTROLLER FOR CURRENT HARMONIC MITIGATION

CHAPTER 6. CALCULATION OF TUNING PARAMETERS FOR VIBRATION CONTROL USING LabVIEW

Single Phase Shunt Active Filter Simulation Based On P-Q Technique Using PID and Fuzzy Logic Controllers for THD Reduction

Self-Tuning PI-Type Fuzzy Direct Torque Control for Three-phase Induction Motor

Simulation of Synchronous Machine in Stability Study for Power System: Garri Station as a Case Study

DESIGNING POWER SYSTEM STABILIZER FOR MULTIMACHINE POWER SYSTEM USING NEURO-FUZZY ALGORITHM

Fuzzy Logic Controller on DC/DC Boost Converter

DC Motor Speed Control: A Case between PID Controller and Fuzzy Logic Controller

High Frequency Soft Switching Boost Converter with Fuzzy Logic Controller

Abstract: PWM Inverters need an internal current feedback loop to maintain desired

Self Tuning Mechanism using Input Scaling Factors of PI like Fuzzy Controller for Improved Process Performance

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

1. Governor with dynamics: Gg(s)= 1 2. Turbine with dynamics: Gt(s) = 1 3. Load and machine with dynamics: Gp(s) = 1

Control of DC-DC Buck Boost Converter Output Voltage Using Fuzzy Logic Controller

Comparison of Fuzzy Logic Based and Conventional Power System Stabilizer for Damping of Power System Oscillations

Application of Fuzzy Logic Controller in Shunt Active Power Filter

FUZZY AND NEURO-FUZZY MODELLING AND CONTROL OF NONLINEAR SYSTEMS

Modeling & Simulation of PMSM Drives with Fuzzy Logic Controller

CHAPTER 6 NEURO-FUZZY CONTROL OF TWO-STAGE KY BOOST CONVERTER

Design of Joint Controller for Welding Robot and Parameter Optimization

FUZZY BASED SMART LOAD PRIMARY FREQUENCY CONTROL CONTRIBUTION USING REACTIVE COMPENSATION

Open Access Design of Diesel Engine Adaptive Active Disturbance Rejection Speed Controller

Design and Implementation of Self-Tuning Fuzzy-PID Controller for Process Liquid Level Control

Intelligent Fuzzy-PID Hybrid Control for Temperature of NH3 in Atomization Furnace

A Comparative Analysis of GA-PID, Fuzzy and PID for Water Bath System

A Comparative Study on Speed Control of D.C. Motor using Intelligence Techniques

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

The Open Automation and Control Systems Journal, 2015, 7, Application of Fuzzy PID Control in the Level Process Control

International Journal of Advance Engineering and Research Development. Aircraft Pitch Control System Using LQR and Fuzzy Logic Controller

Real-Coded Genetic Algorithm for Robust Design of UPFC Supplementary Damping Controller

Fuzzy Controlled DSTATCOM for Voltage Sag Compensation and DC-Link Voltage Improvement

Smart Home System for Energy Saving using Genetic- Fuzzy-Neural Networks Approach

Automatic Generation Control of Two Area using Fuzzy Logic Controller

Investigations of Fuzzy Logic Controller for Sensorless Switched Reluctance Motor Drive

Design and Implementation of Fuzzy Sliding Mode Controller for Switched Reluctance Motor

Fuzzy Control Scheme for Damping of Oscillations in Multi Machine. Power System with UPFC

Sp-eed Control of Brushless DC Motor Using Genetic Algorithim Based Fuzzy Controller*

PERFORMANCE STUDIES OF INTEGRATED FUZZY LOGIC CONTROLLER FOR BRUSHLESS DC MOTOR DRIVES USING ADVANCED SIMULATION MODEL

A Brushless DC Motor Speed Control By Fuzzy PID Controller

Fuzzy Gain Scheduled PI Controller for a Two Tank Conical Interacting Level System

ISSN: [IDSTM-18] Impact Factor: 5.164

IMPLEMENTATION OF FUZZY LOGIC SPEED CONTROLLED INDUCTION MOTOR USING PIC MICROCONTROLLER

International Journal of Scientific & Engineering Research, Volume 6, Issue 8, August ISSN

IMPROVING POWER SYSTEM STABILITY USING REAL-CODED GENETIC ALGORITHM BASED PI CONTROLLER FOR STATCOM

Resistance Furnace Temperature Control System Based on OPC and MATLAB

Comparative analysis of Conventional MSSMC and Fuzzy based MSSMC controller for Induction Motor

An Expert System Based PID Controller for Higher Order Process

The Pitch Control Algorithm of Wind Turbine Based on Fuzzy Control and PID Control

Research Article Multi-objective PID Optimization for Speed Control of an Isolated Steam Turbine using Gentic Algorithm

Performance Improvement Of AGC By ANFIS

High Efficiency DC/DC Buck-Boost Converters for High Power DC System Using Adaptive Control

Performance Analysis of PSO Optimized Fuzzy PI/PID Controller for a Interconnected Power System

Fuzzy PID Speed Control of Two Phase Ultrasonic Motor

Fuzzy PID Controller Enhancement of Power System using TCSC

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

ADJUSTMENT OF PARAMETERS OF PID CONTROLLER USING FUZZY TOOL FOR SPEED CONTROL OF DC MOTOR

Optimum Coordination of Overcurrent Relays: GA Approach

Fuzzy Intelligent Controller for the MPPT of a Photovoltaic Module in comparison with Perturb and Observe algorithm

Review of PI and PID Controllers

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

Design of Power System Stabilizer using Intelligent Controller

6545(Print), ISSN (Online) Volume 4, Issue 1, January- February (2013), IAEME & TECHNOLOGY (IJEET)

Fuzzy logic damping controller for FACTS devices in interconnected power systems. Ni, Yixin; Mak, Lai On; Huang, Zhenyu; Chen, Shousun; Zhang, Baolin

Simulation of Optimal Speed Control for a DC Motor Using Conventional PID Controller and Fuzzy Logic Controller

International Journal of Scientific & Engineering Research, Volume 6, Issue 6, June-2015 ISSN

IJITKM Special Issue (ICFTEM-2014) May 2014 pp (ISSN )

Design Of PID Controller In Automatic Voltage Regulator (AVR) System Using PSO Technique

Improvement in Dynamic Response of Interconnected Hydrothermal System Using Fuzzy Controller

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

TWO AREA CONTROL OF AGC USING PI & PID CONTROL BY FUZZY LOGIC

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

Temperature Control in HVAC Application using PID and Self-Tuning Adaptive Controller

Implementation of Fuzzy Controller to Magnetic Levitation System

FOUR TOTAL TRANSFER CAPABILITY. 4.1 Total transfer capability CHAPTER

Investigating Stability Comparison of a Conventional Controller and Fuzzy Controller on a Non-Linear System

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Review Paper on Comparison of various PID Controllers Tuning Methodologies for Heat Exchanger Model

PID Controller Design Based on Radial Basis Function Neural Networks for the Steam Generator Level Control

Digital Control of MS-150 Modular Position Servo System

Speed control of a DC motor using Controllers

Modelling for Temperature Non-Isothermal Continuous Stirred Tank Reactor Using Fuzzy Logic

CHAPTER 3 METHODOLOGY

Fuzzy Expert Systems Lecture 9 (Fuzzy Systems Applications) (Fuzzy Control)

Control Of Three Phase BLDC Motor Using Fuzzy Logic Controller Anjali. A. R M-Tech in Powerelectronics & Drives,Calicut University

Chapter 10: Compensation of Power Transmission Systems

Transcription:

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,9 6, 2M Open access books available International authors and editors Downloads Our authors are among the 54 Countries delivered to TOP % most cited scientists 2.2% Contributors from top 5 universities Selection of our books indexed in the Book Citation Index in Web of Science Core Collection (BKCI) Interested in publishing with us? Contact book.department@intechopen.com Numbers displayed above are based on latest data collected. For more information visit www.intechopen.com

Chapter 6 Self-Tuning Fuzzy PI Controller (STFPIC) Salman Hameed Additional information is available at the end of the chapter http://dx.doi.org/.5772/598. Introduction Traditionally, control systems are designed through mathematical analysis and synthesis techniques. A wealth of control design techniques through mathematical approaches is available in the literature. Now, the first step for control system design through mathematical techniques is to obtain a proper model of the process to be controlled. However, for a highly nonlinear system like power system, it is often quite difficult to obtain an accurate mathematical model. Because of the inaccurate model, it is often quite an arduous task to design a control system which would be effective over a wide range of operating conditions. Under these conditions, Fuzzy Logic Controllers (FLCs) can be used quite effectively for controlling the process. Fuzzy logic controllers are essentially model free controllers, which try to control a process, based on the experience of a skilled human operator without requiring a detailed model of the process to be controlled. In many cases, application of fuzzy logic approach makes it possible to design a control system that is more robust, cost-effective, and easier to design as compared to a controller developed based on mathematical techniques. Motivated by the above features of FLC, an attempt has been made to design fuzzy logic TCSC (Thyristor controlled series capacitor) controllers to improve power system stability. Generally, fuzzy PI controllers (FPIC) have been used in which the inputs to the fuzzy controllers are error (e) and charge in error ( e), while the output of FPIC is the incremental change in the control output ( u). The error (e) is defined as e = P ref P act, where P ref is the steady-state power flowing through the line (in which TCSC is installed) and P act is the actual power flowing through that particular line following a disturbance. From these two inputs, the FPIC generates the incremental change in TCSC reactance as its output ( u = x TCSC ).The main components of any FLC are fuzzification unit, fuzzy inference unit, fuzzy rule base, and defuzzification unit. The fuzzification unit maps the measured crisp inputs into the fuzzy linguistic values which are subsequently used by the fuzzy inference mechanism. It is to be noted that the actual values of the e and e are not submitted directly to the fuzzification unit. The quantities e and e are first converted to normalized quantities e N and e N, respectively, by using scaling factors G e 25 The Author(s). Licensee InTech. This chapter is distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

42 Fuzzy Logic - Tool for Getting Accurate Solutions and G e and subsequently these normalized quantities are passed to the fuzzification unit. The fuzzy inference mechanism, utilizing the fuzzy rule base, performs fuzzy logic operations on the fuzzified inputs to infer the control action. Finally, the defuzzification unit converts the inferred fuzzy control action into crisp, normalized incremental change in control output ( u N ), which, in turn, is converted into actual incremental change in control output ( u) by using the scaling factor G u. These three scaling factors (G e, G e, and G u ) are the main parameters for tuning the FPIC because variation of scaling factors (SFs) changes the normalized universe of discourse for input and output variables and their corresponding membership functions. These SFs play a role similar to that of the gains of a conventional controller. Therefore, they are extremely important for the controller stability and performance. Generally, there is no well-defined method for computing the appropriate values of SFs for FLC and as a result, the values of these SFs are sometimes decided by trial-and-error technique. To circumvent this trial-and-error procedure, a genetic algorithm (GA)-based technique is proposed for finding the appropriate values for G e, G e, and G u. The proposed GA-based technique is described in details in []. The scaling factors have been tuned such that the power system oscillations are minimized after the occurrence of a disturbance. Specifically, the aim is to minimize the error between the P ref and P act following a disturbance. Various performance indices can be used to represent the above goal mathematically. Here, the integral of squared error (ISE) index has been used as it tends to place a greater penalty on large errors. In many practical cases, even after a controller is established, there is a need to further tune the controller on-line. The necessity of applying further on-line tuning arises in situations where a controller must operate under uncertainty and/or when the available information is so limited that it is impossible or impractical to design in advance a controller with fixed properties. The main goal of the auto-tuning controller is to make the controller robust as far as possible when subjected to a wide range of operating conditions. In this chapter, a simple and effective fuzzy-logic-based method for on-line tuning of TCSC FPIC is presented. The resulting controller is termed as self-tuning fuzzy PI controller (STFPIC).The effectiveness of the developed STFPIC has been validated through detailed nonlinear dynamic simulation studies on two different multimachine power systems. These study systems are: (a) two-area 4-machine system and (b) -machine 39-bus system. The simulation studies have been carried out on MATLAB/SIMULINK environment. A large number of fault cases involving three-phase, 5-cycle, solid short-circuit faults have been investigated on both these study systems for different loading conditions as well as different fault locations. From the simulation results, it has been observed that the proposed STFPIC for TCSC improves the system stability significantly. The detailed description of STFPIC is given in the following sections. 2. Self-tuning scheme Fuzzy logic controllers (FLCs) contain a number of sets of parameters that can be altered to modify the controller performance. These are:

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 43 The scaling factors (SFs) for each variable The fuzzy sets representing the meaning of linguistic values The if-then rules A nonadaptive FLC is one in which these parameters do not change once the controller goes on-line. Adaptive FLCs have the capability of altering these parameters on-line. Further, the adaptive fuzzy controllers that modify the fuzzy set definitions or the scaling factors are called self-tuning or auto-tuning fuzzy logic controllers (FLCs) [2, 3]. Alteration of these parameters essentially fine-tunes an already working controller. On the other hand, adaptive FLCs that alter the rules are called self-organizing controllers [3]. These two types of fuzzy logic controllers have been developed [4-] and implemented for various practical processes. Of the various tunable parameters, SFs have the highest priority due to their global effect on the control performance because changing the SFs changes the normalized universe of discourse, the domains, and the membership functions of input/output variables of FLC [3]. 2.. Self-tuning fuzzy PI controller (STFPIC) It has been experimentally observed that a conventional FLC with constant scaling factors and a limited number of IF THEN rules may have limited performance for a highly nonlinear plant [2]. As a result, there has been significant research on tuning of FLCs where either the input or output scaling factors or the definitions of the membership functions (MFs) and sometimes the control rules are tuned to achieve the desired control objectives [5, 8, ]. Here, only the output scaling factor (SF) is tuned due to its strong influence on the performance and stability of the system. In this scheme, the output SF of the FLC is adjusted on-line according to the current states of the controlled processes. Specifically, the tuning of the output SF is based on the value of instantaneous error and change in error (e and Δe). The block diagram of the Self-tuning Fuzzy PI type Controller (STFPIC) is shown in Fig. [3, 4]. From this figure, it is observed that by the use of a self-tuning mechanism, the controller s output SF gets modified, as shown by the dotted boundary. Thus, the output scaling factor gets modified at each sampling time and is updated by the gain updating factor α. This process depends on the trend followed by the controlled process output and the value of α is obtained using fuzzy rules [3, 9]. In contrast to FPIC (which has only one fuzzy logic block), there are two fuzzy logic blocks in STFPIC as shown in Fig. The top fuzzy logic block in Fig. computes the main control output (Δu) of the FLC. The membership functions (MFs) for e, Δe, and Δu corresponding to this fuzzy logic block are shown in Fig. 2. The rule base for computing Δu is shown in Table The second fuzzy logic block (shown in dotted boundary) calculates the gain updating factor α at each sampling instant. For this second fuzzy block also, the MFs for e and Δe are same as shown in Fig. 2. The membership functions used for the factor α are defined in the domain [] and are shown in Fig. 3. As each of the two inputs has 7 fuzzified variables, the rule base has a total 49 rules for calculating α as shown in Table 2. This rule base improves the control performance under large disturbances such as sudden loss of a generating unit or a large load, three-phase short circuit on the transmission lines, etc. [3, 2]. For example, immediately after a large

44 Fuzzy Logic - Tool for Getting Accurate Solutions disturbance, e may be small but Δe will be sufficiently large (they will be of same sign) and, for this case, α should be large to increase the gain. Therefore, under these circumstances, the appropriate rules are IF e is PS and Δe is PM, THEN α is B or IF e is NS and Δe is NM, THEN α is B. On the other hand, for steady-state conditions (i.e., e and Δe ), controller gain should be very small (e.g., IF e is ZE and Δe is ZE, THEN α is ZE) to avoid chattering problem around the set point. Further justification for using the rule base in Table 2 can be found in [3]. Rule-base R + y Z + e e G e G e en e N Inference Mechanism Fuzzification Defuzzification u N G u.α u + + u Z Inference Mechanism Fuzzification Defuzzification α Rule-base 2 GAIN TUNING MECHANISM y Process Figure. Block diagram of the STFPIC The following steps have been used for tuning the STFPIC [3]. Step : Tune the SFs of the STFPIC without the gain tuning mechanism and assuming α = (i.e., conventional FLC) for a given process to achieve a reasonably good control performance. For the tuning of the conventional FLC, GA [5, 2] has been used. At the end of this step, a good controller without self-tuning feature is obtained and this controller becomes the starting point (input) for the self-tuning controller in Step 2. Step 2: Set the output SF (G u ) of the self-tuning FLC K times greater than that obtained in Step, keeping the values of G e and G Δe same as those of the conventional FLC. In this step, α, and is obtained from the rule base in Table 2. This factor K for the STFPIC (to enhance the value of G u ) is found empirically with an objective to maintain the same rise time as that of the conventional FLC [3].

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 45 NB NM NS ZE PS PM PB - -.66.66 Figure 2. MFs for e, Δe, and Δu. N: Negative, P: Positive, ZE: Zero, B: Big, M: Medium, S: Small Δe/e NB NM NS ZE PS PM PB NB NB NB NB NM NS NS ZE NM NB NM NM NM NS ZE PS NS NB NM NS NS ZE PS PM ZE NB NM NS ZE PS PM PB PS NM NS ZE PS PS PM PB PM NS ZE PS PM PM PM PB PB ZE PS PS PM PB PB PB Table. Rule Base for Δu ZE VS S SB MB B VB.7.5.83 Figure 3. MFs for gain updating factor (α). ZE: Zero, V: Very, B: Big, M: Medium, S: Small

46 Fuzzy Logic - Tool for Getting Accurate Solutions Δe/e NB NM NS ZE PS PM PB NB VB VB VB B SB S ZE NM VB VB B B MB S VS NS VB MB B VB VS S VS ZE S SB MB ZE MB SB S PS VS S VS VB B MB VB PM VS S MB B B VB VB PB ZE S SB B VB VB VB Table 2. Rule Base for α 2.2. Scaling factor s tuning using genetic algorithm (GA) Here, the power system oscillations are minimized by tuning of the scaling factors using GA. The aim is to minimize the error between the steady-state power (P ref ) flowing through the line in which the TCSC is installed and the actual power flowing through that line (P actual ) after a disturbance [2, 9]. Several performance indices can be used to represent the above goal mathematically. The integral of the squared error (ISE) [2] as shown in eqn. () has been selected as it tends to place a greater penalty on large errors. This goal can be formulated as the minimization of the objective function F where, t sim 2 F e ( t) dt = ò () In eqn. (), e(t)= P ref P actual is the error in power flow in the line following a disturbance and t sim is the total time period of simulation. As the objective function of eqn. () is nonconvex in nature, GA has been used to minimize F. A basic introduction to GA is given in Section 2. 2.2.. Genetic algorithm (GA) Various conventional optimization techniques are available in the literature, which can be used to optimize the controller parameters effectively. The conventional optimization approach, based on gradient descent technique, sometimes gets stuck at local minima giving suboptimal controllers. Genetic Algorithms (GAs) offer promising potential for optimizing controller parameters and it uses the concept of Darwin s theory of evolution. As per this theory, the existence of all living things is based on the rule of survival of the fittest []. GA makes use of three fundamental operators, namely, reproduction, crossover, and mutation, which are explained later in this section. The basic principle of GA is to initially form different possible solutions to a problem and then test them for their performance. By using the rule of survival of the fittest, only a fraction of the better solutions are selected, eliminating the remaining ones. Genetic operators (reproduction, crossover, and mutation) are then applied to the selected solutions resulting in

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 47 a new generation of possible solutions (which are expected to perform better than the previous generation). The above steps are repeated until a specific termination criterion is met (such as maximum number of generations, negligible variation in performance or fitness value, etc.). Search space of GA does not confine to a narrow expected region (as in the case of gradient descent), but rather includes a broad spectrum of possible solutions. It is capable of obtaining the global solution of a wide variety of functions such as differentiable or nondifferentiable, linear or nonlinear, continuous or discrete, and analytical or procedural []. GA tries to perform an intelligent search for a solution from a nearly infinite number of possible solutions. 2.2.2. Basic tuning procedure The overall flowchart for optimization using GA is shown in Fig. 4. Initially, a number of populations (N) have been generated for the scaling factors. Each of the populations consists of the binary strings corresponding to the scaling factors G e, G Δe, and G u. These strings are created in a random fashion with the constrain that the values of G e, G Δe, and G u should lie within their specified ranges. The ranges chosen for each of these scaling factors are shown in Table 3. For each of these N sets of values of G e, G Δe, and G u, time domain nonlinear simulation studies have been carried out for evaluating the objective function F of eqn. (). For this, t sim has been taken as 8 s. Based on the values of the objective function, out of these N possible solutions, the good solutions are retained and the others are eliminated (following the principle of survival of the fittest) [, 5, 9]. The selected solutions undergo the processes of reproduction, crossover, and mutation to create a new generation of possible solutions (which are expected to perform better than the previous generation). This process of production of a new generation and its evaluation is performed repetitively. The algorithm stops when a predefined maximum number of generations is achieved [, 5, 9]. The parameters used for GA are shown in Table 4. Start Generate Initial Population Gen.= Time Domain Simulation of Pow er System Model Gen.=Gen.+ Objective Function Evaluation GA Operators Gen. > Max. Gen.? Yes End No Figure 4. Flowchart of the GA optimization algorithm

48 Fuzzy Logic - Tool for Getting Accurate Solutions Parameters G e G Δe G u Minimum range Maximum range.5 Table 3. Ranges for the different scaling factors Parameter Value/Type Maximum generations 5 Population size 25 Mutation rate. Crossover operator Scattered Table 4. Parameters used in genetic algorithm 3. Case studies The efficacy of the projected STFPIC has been validated on two different multimachine power systems: (a) two-area 4-machine system [6] and (b) -machine 39-bus system [6, 9]. The details of these two systems are presented in Section 3. 3.. Study systems The schematic diagram of the two-area 4-machine system is shown in Fig. 5. In this system, machines, 2 and 3, 4 form two different coherent groups. The three tie lines connect these two coherent areas. As shown in Fig. 5, a TCSC has been installed in the middle of one of these tie lines [7, 9]. G 5 6 9 5 6 9 2 3 TCSC 4 7 8 8 2 7 3 G3 Area Area 2 Load A Load B 2 4 G2 G4 Figure 5. TCSC in a two-area 4-generator system The one line diagram of the second study system of this work, i.e., the -machine 39-bus system is shown in Fig. 6. In this diagram, the generators are identified by their bus numbers

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 49 to which they are connected. In this system, a TCSC has been assumed to be installed in the middle of the tie line connecting buses #39 and #36. 38 8 25 26 37 27 28 24 29 9 2 36 3 35 6 2 4 32 34 39 2 22 9 8 5 7 6 3 33 3 23 4 5 7 2 3 Figure 6. Schematic diagram of -machine, 39-bus system 3.2. Simulation results The effectiveness of the self-tuning fuzzy PI controller (STFPIC) has been studied through detailed nonlinear time domain simulation studies for a three-phase, 5-cycle, solid short-circuit faults on both the test systems shown above. The short-circuit faults have been assumed to occur at t = 5 s. The simulation studies have been carried out in the MATLAB/SIMULINK environment [8]. For illustrating the efficacy of the fuzzy controllers developed in this work, results pertaining to two different situations are presented. These situations are: (a) study system with a TCSC controlled by FPIC and (b) study system with a TCSC controlled by STFPIC. For following figures, the rotor angles of the machines have been measured with respect to the Centre of Inertia (COI) reference [6].

5 Fuzzy Logic - Tool for Getting Accurate Solutions 3.2.. Two-area 4-machine system For this system, initially the short-circuit fault has been assumed to occur at bus 9. The variations of the rotor angles of the two machines (machine and machine 4) and active power flow in line (P - ) for the base case loading condition (the loading condition as described in [6, 2]) are displayed in Figs. 7 and 8, and 9(a), corresponding to scenarios (a) and (b), respectively. In Figs. 7 9, the dotted lines show the variation of rotor angle, whereas the variation of rotor angle is depicted with solid lines. For implementing STFPIC, K has been set equal to 3. From Figs. 7 to 8, and 9(a), it is observed that there is perceptible improvement in the performance of the system as the oscillations are damped earlier by the STFPIC proposed for TCSC. The variations of the TCSC reactance (X TCSC ) are shown in Fig. 9(b) for situations (a) and (b). To investigate the performance of the TCSC STFPIC controller at enhanced loading condition, simulation studies were carried out by increasing the system loads by % from the base case loading condition. The results are shown in Figs. and, and 2, corresponding to scenarios (a) and (b), respectively. From Figs. to and 2(a), it is evident that at % higher loading, the TCSC STFPIC improves the system performance. Figure 2(b) shows the variation of the TCSC reactance for this case and TCSC STFPIC. It can be observed from Figs. 9(b) and 2(b) that STFPIC has been able to improve the damping with smaller variation in X TCSC as compared to FPIC for the base case and % loading conditions respectively with fault at bus 9.The variations of α for fault at bus 9 are shown in Fig. 3, corresponding to both base case and % increased loading conditions. From these figures it is observed that for different loading conditions, the TCSC STFPIC always improves the system performance, showing the robustness of the controller. The performance of the TCSC STFPIC has also been studied with faults at different locations for both base case and % increased loading conditions. The simulation results for faults at bus 8 are shown in Figs. 4 9 with the variations of α depicted in Fig. 2. Similarly, the results corresponding to fault at bus 5 are shown in Figs. 2 26 with the variations of α displayed in Fig. 27. From these figures, it is observed that irrespective of the fault location, the TCSC STFPIC always improves the system performance. 3.2.2. -machine 39-bus system In this system, initially the short-circuit fault has been assumed to occur at bus 24. From the fault simulation studies carried out at the base case loading condition (the loading condition as described in [6, 9]), it has been observed that the proposed TCSC STFPIC improved the system performance. Subsequently, a great number of fault studies have been carried out at several increased system loading situations to inspect the effectiveness of the developed STFPIC for improving the performance of the system. After all these studies, it has been found that the TCSC STFPIC helps to further increase the damping for the system. Only a few representative results are presented below to illustrate the effectiveness of the developed STFPIC in further enhancing the performance of the system under study.

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 5 δ.3.25.2.5..5 5 5 2 25 3 35 4 Figure 7. Rotor angle of generator with STFPIC for base case with fault at bus 9 δ 4 -. -.5 -.2 -.25 -.3 5 5 2 25 3 35 4 Figure 8. Rotor angle of generator 4 with STFPIC for base case with fault at bus 9

52 Fuzzy Logic - Tool for Getting Accurate Solutions.5 (a) Power flow in line -.5 -.5 5 5 2 25 3 35 4..5 (b) X TCSC -.5 -. 5 5 2 25 3 35 4 Figure 9. Active power flow in line - and TCSC capacitive reactance with STFPIC for base case with fault at bus 9 δ.35.3.25.2.5..5 2 3 4 5 Figure. Rotor angle of generator with STFPIC for % loading with fault at bus 9

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 53 δ 4 -. -.5 -.2 -.25 -.3 -.35 5 5 2 25 3 35 4 45 5 Figure. Rotor angle of generator 4 with STFPIC for % loading with fault at bus 9.5 (a) Power flow in line -.5 -.5 5 5 2 25 3 35 4 45 5..5 -.5 (b) X TCSC -. 5 5 2 25 3 35 4 45 5 Figure 2. Active power flow in line - and TCSC capacitive reactance with STFPIC for % loading with fault at bus 9

54 Fuzzy Logic - Tool for Getting Accurate Solutions (a) Base case α.5 2 3 4 5 6 (b) % loading α.5 2 3 4 5 6 Figure 3. Variation of α for base case and % loading with fault at bus 9.24.22 δ.2.8.6.4.2..8.6 5 5 2 25 3 35 4 Figure 4. Rotor angle of generator with STFPIC for base case with fault at bus 8

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 55 -. -.2 δ 4 -.4 -.6 -.8 -.2 -.22 5 5 2 25 3 35 4 Figure 5. Rotor angle of generator 4 with STFPIC for base case with fault at bus 8 (a) Power flow in line -.8.6.4.2 5 5 2 25 3 35 4..5 (b) X TCSC -.5 -. 5 5 2 25 3 35 4 Figure 6. Active power flow in line - and TCSC capacitive reactance with STFPIC for base case with fault at bus 8

56 Fuzzy Logic - Tool for Getting Accurate Solutions.3.25 δ.2.5..5 2 3 4 5 6 Figure 7. Rotor angle of generator with STFPIC for % loading with fault at bus 8 -.2 -.4 δ 4 -.6 -.8 -.2 -.22 -.24 -.26 2 3 4 5 6 Figure 8. Rotor angle of generator 4 with STFPIC for % loading with fault at bus 8

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 57.5 (a) Power flow in line -.5 2 3 4 5 6..5 (b) X TCSC -.5 -. 2 3 4 5 6 Figure 9. Active power flow in line - and TCSC capacitive reactance with STFPIC for % loading with fault at bus 8.8 (a) Base case α.6.4.2 2 3 4 5 6.8 (b) % loading α.6.4.2 2 3 4 5 6 Figure 2. Variation of α for base case and % loading with fault at bus 8

58 Fuzzy Logic - Tool for Getting Accurate Solutions.4.35 δ.3.25.2.5..5 5 5 2 25 3 35 4 Figure 2. Rotor angle of generator with STFPIC for base case with fault at bus 5 δ 4 -. -.5 -.2 -.25 -.3 5 5 2 25 3 35 4 Figure 22. Rotor angle of generator 4 with STFPIC for base case with fault at bus 5

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 59.5 (a) Power flow in line -.5 5 5 2 25 3 35 4..5 (b) X TCSC -.5 -. 5 5 2 25 3 35 4 Figure 23. Active power flow in line - and TCSC capacitive reactance with STFPIC for base case with fault at bus 5.45.4 δ.35.3.25.2.5..5 5 5 2 25 3 35 4 45 5 Figure 24. Rotor angle of generator with STFPIC for % loading with fault at bus 5

6 Fuzzy Logic - Tool for Getting Accurate Solutions δ 4 -. -.5 -.2 -.25 -.3 -.35 5 5 2 25 3 35 4 45 5 Figure 25. Rotor angle of generator 4 with STFPIC for % loading with fault at bus 5.5 (a) Power flow in line -.5 2 3 4 5 6..5 (b) X TCSC -.5 -. 2 3 4 5 6 Figure 26. Active power flow in line - and TCSC capacitive reactance with STFPIC for % loading with fault at bus 5

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 6 (a) Base case α.5 2 3 4 5 6 (b) % loading α.5 2 3 4 5 6 Figure 27. Variation of α for base case and % loading with fault at bus 5 The performance of the TCSC STFPIC at 6% loading condition (w.r.t. the base case loading condition as described in [6]) is shown in Figs. 28 3 From these figures it is observed that at 6% loading condition, substantial improvement in the system performance is achieved by the proposed TCSC STFPIC. For implementing STFPIC, K has been set equal to. When the system loading level is further increased to 75% of the base case loading condition, the proposed TCSC STFPIC is able to improve the system performance significantly as illustrated in Figs. 32 and 33. It can be noticed from Figs. 3(b) and 33(b) that STFPIC has been able to improve the damping with smaller variation in X TCSC as compared to FPIC for 6% and 75% loading conditions, respectively, with fault at bus 24. The variations of α for fault at bus 24 are shown in Fig. 34, corresponding to 6% and 75% loading conditions. Additional fault simulation studies have also been carried out with faults at different locations, for various loading conditions, to investigate the robustness of the proposed control scheme. For all the simulation studies carried out in this work, the TCSC STFPIC has improved the damping of the system (as compared to the damping obtained with FPIC). Some representative results obtained at 75% loading condition are shown in Figs. 35 38. Figures 35 and 36 show the results for fault at bus 38, while the results for fault at bus 23 are shown in Figs. 37 and 38. These results amply demonstrate that the TCSC STFPIC helps to enhance the damping capability of the system quite significantly. The variations of α for fault at bus 38 and 23 corresponding to 75% loading conditions are shown in Fig. 39. Variation of the rotor angle of generator 3 only has been shown for 75% loading condition.

62 Fuzzy Logic - Tool for Getting Accurate Solutions (a) δ.2 -.2 5 5 2 25 3 35 4 45 5 (b) δ 2.2 -.2 5 5 2 25 3 35 4 45 5 Figure 28. Rotor angles of generator and 2 with STFPIC for 6% loading with fault at bus 24 (a) δ 7.5 -.5 5 5 2 25 3 35 4 45 5 (b) δ 8.2 -.2 5 5 2 25 3 35 4 45 5 Figure 29. Rotor angles of generator 7 and 8 with STFPIC for 6% loading with fault at bus 24

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 63 (a) δ 9.6.4.2 -.2 -.4 5 5 2 25 3 35 4 45 5 (b) δ -.2 -.4 -.6 -.8 5 5 2 25 3 35 4 45 5 Figure 3. Rotor angles of generator 9 and with STFPIC for 6% loading with fault at bus 24 8 6 4 2 (a) Power flow in line 39-36 -2 5 5 2 25 3 35 4 45 5.2. (b) X TCSC -. -.2 5 5 2 25 3 35 4 45 5 Figure 3. Active power flow in line 39-36 and TCSC capacitive reactance with STFPIC for 6% loading with fault at bus 24

64 Fuzzy Logic - Tool for Getting Accurate Solutions δ 3. -. -.2 -.3 -.4 2 3 4 5 6 7 8 Figure 32. Rotor angle of generator 3 for 75% loading with STFPIC for fault at bus 24 5 (a) Power flow in line 39-36 -5 2 3 4 5 6 7 8.2. (b) X TCSC -. -.2 2 3 4 5 6 7 8 Figure 33. Active power flow in line 39-36 and TCSC capacitive reactance with STFPIC for 75% loading with fault at bus 24

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 65.8 (a) 6% loading α.6.4.2 2 3 4 5 6 7 8.8 (b) 75% loading α.6.4.2 2 3 4 5 6 7 8 Figure 34. Variation of α for 6% and 75% loading with fault at bus 24 δ 3. -. -.2 -.3 -.4 2 3 4 5 6 7 8 Figure 35. Rotor angle of generator 3 for 75% loading with STFPIC for fault at bus 38

66 Fuzzy Logic - Tool for Getting Accurate Solutions 5 (a) Power flow in line 39-36 -5 2 3 4 5 6 7 8.2. (b) X TCSC -. -.2 2 3 4 5 6 7 8 Figure 36. Active power flow in line 39-36 and TCSC capacitive reactance with STFPIC for 75% loading with fault at bus 38..5 δ 3 -.5 -. -.5 -.2 -.25 -.3 -.35 -.4 2 3 4 5 6 7 8 Figure 37. Rotor angle of generator 3 for 75% loading with STFPIC for fault at bus 23

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 67 5 (a) Power flow in line 39-36 -5 2 3 4 5 6 7 8.2. (b) X TCSC -. -.2 2 3 4 5 6 7 8 Figure 38. Active power flow in line 39-36 and TCSC capacitive reactance with STFPIC for 75% loading with fault at bus 23.8 (a) Fault at bus 38 α.6.4.2 2 3 4 5 6 7 8.8 (b) Fault at bus 23 α.6.4.2 2 3 4 5 6 7 8 Figure 39. Variation of α for 75% loading with fault at bus 38 and 23

68 Fuzzy Logic - Tool for Getting Accurate Solutions 4. Conclusion In this chapter, a methodology has been discussed for designing an adaptive FPIC using selftuning mechanism (STFPIC). The simulation studies have been carried out in MATLAB/ SIMULINK environment. A large number of fault cases involving three-phase, 5-cycle, solid short-circuit faults have been investigated on both the study systems discussed earlier, for different loading conditions as well as different fault locations. From the simulation results, it has been observed that the proposed STFPIC for TCSC improves the system stability significantly. In this scheme, the output scaling factor of the FPIC is modulated on-line by a gain updating factor (α) whose value is determined by a second fuzzy logic scheme. Hence, the output scaling factor of STFPIC does not remain fixed while the controller is in operation, rather it is modified at each sampling instant by a gain updating factor α. The effectiveness of the developed STFPIC has been studied through detailed nonlinear fault simulation studies on both the test systems. The same fault cases have also been studied with FPIC and the performances obtained by STFPIC have been compared to those obtained by FPIC. From the comparative simulation results, it can be observed that the proposed STFPIC for TCSC improves the system damping further (as compared to the system damping obtained by FPIC). The STFPIC, which comprises of two fuzzy logic blocks, requires increased computational time and memory for implementation. Therefore, it would be advantageous to reduce the size of the rule base so that the requirement of computational time and memory for implementation is reduced. The performances of FPIC and STFPIC discussed in this chapter have been tested with predesigned scaling factors. However, in real life, the operating point in the system may vary continuously, thereby making it almost impossible to predesign the scaling factors. Thus, it is necessary to determine the scaling factors on-line based on some suitable measurements. In future, such a scheme for on-line determination of the scaling factors will be described. The proposed self-tuning philosophy may possibly be applied for the tuning of input SFs or for tuning of both input and output SFs simultaneously, which may lead to superior performances of the FLCs. The efficacy and suitability of the proposed techniques can be explored further by applying it to larger power systems for different operating conditions. Author details Salman Hameed * Address all correspondence to: hameeddee@gmail.com Department of Electrical Engineering, Aligarh Muslim University, Aligarh, India

Self-Tuning Fuzzy PI Controller (STFPIC) http://dx.doi.org/.5772/598 69 References [] D. E. Goldberg, Genetic Algorithms in Search, Optimization and Machine Learning: Pearson Education Asia, 2 [2] J. Yan, M. Ryan and J. Power, Using Fuzzy Logic Towards intelligent systems, Prentice Hall International (UK) Ltd, 994. [3] D. Driankov, H. Hellendoorn and M. Reinfrank, An Introduction to Fuzzy Control, Springer-Verlag, New York, 993. [4] S. Z. He, S. Tan, F. L. Xu and P. Z. Wang, Fuzzy self-tuning of PID controller, Fuzzy Sets and Systems, vol. 56, no., May 993, pp. 37 46. [5] M. Maedo and S. Murakami, A self-tuning fuzzy controller, Fuzzy Sets and Systems, vol. 5, no., October 992, pp. 29-4. [6] S. Shao, Fuzzy self-organizing controller and its application for dynamic processes, Fuzzy Sets and Systems, vol. 26, no. 2, May 988, pp. 5 64. [7] Y. Park, U. Moon and K. Y. Lee, A self-organizing fuzzy logic controller for dynamic systems using a fuzzy auto-regressive moving average (FARMA) model, IEEE Transactions on Fuzzy Systems, vol. 3, no., February 995, pp. 75 82. [8] R. K. Mudi and N. K. Pal, A self-tuning fuzzy PI controller, Fuzzy Sets and Systems, vol. 5, no. 2, October 2, pp. 327-338. [9] C. T. Chao and C. C. Teng, A PD-like self-tuning fuzzy controller without steadystate error, Fuzzy Sets and Systems, vol. 87, no. 2, April 997, pp. 4-54. [] Z. W. Woo, H. Y. Chung and J. J. Lin, A PID type fuzzy controller with self-tuning scaling factors, Fuzzy Sets and Systems, vol. 5, no. 2, October 2, pp. 32-326. [] Y. P. Singh, A modified self-organizing controller for real-time process control applications, Fuzzy Sets and Systems, vol. 96, no. 2, June 998, pp. 47-59. [2] Y. Zhao and E. G. Collins, Jr., Fuzzy PI control design for an industrial weigh belt feeder, IEEE Transactions on Fuzzy Systems, vol., no. 3, June 23, pp. 3-39. [3] R. K. Mudi and N. R. Pal, A robust self-tuning scheme for PI- and PD-type fuzzy controllers, IEEE Transactions on Fuzzy Systems, vol. 7, no., February 999, pp. 2-6. [4] K. Pal, R. K. Mudi and N. R. Pal, A new scheme for fuzzy rule-based system identification and its application to self-tuning fuzzy controllers, IEEE Transactions on Systems, Man, and Cybernetics-Part B: Cybernetics, vol. 32, no. 4, August 22, pp. 47-482. [5] A. Popov, Genetic Algorithm for Optimization. web-site: http://automatics.hit.bg/

7 Fuzzy Logic - Tool for Getting Accurate Solutions [6] K. R. Padiyar, Power System Dynamics - Stability and Control, Interline Publishing Ltd., Bangalore, India 996. [7] B. Chowdhury, R. Majumder and B. C. Pal, Application of multiple-model adaptive control strategy for robust damping of interarea oscillations in power system, IEEE Transactions on Control Systems Technology, vol. 2, no. 5, September 24, pp. 727-736. [8] MATLAB/SIMULINK Software, Version 7.., Release 4, The Math Works Inc. [9] S. Hameed, A self-tuning fuzzy PI controller for TCSC to improve power system stability, Elect Power Sys Res, /28 [2] S. Hameed, Power system stability enhancement using reduced rule base self-tuning fuzzy PI controller for TCSC, IEEE PES T&D, 2, 4/2 [2] S. Hameed, Reduced rule base self-tuning fuzzy PI controller for TCSC, Int J Elect Power Energy Sys, /2