IES LM 79 08 Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC001 010 WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway 1003 7th Ave. Kirkland, WA 98033 Bothell, WA 98011 Attn: Mike Michaels www.orboptronix.com mm@ledabc.com (123) 456 7890 Test report prepared by: Test report approved by: Aaron Miller Laboratory Manager, Test and Measurement Services David Rush Director, Test and Measurement Services in full without permission of. Page 1 of 9
Report: LEDC001 010 WG 1.0 Description of test sample Orb test sample identificaton: LEDC001 01 Manufacturer specifications: Manufacturer: LED ABC Voltage (V): 120 Model number: AA100 222 Test Current (ma): Part Number: P38 400 3500 Wattage (W): 20 Description: LED PAR38 Frequency (Hz): 60 Dimmable: yes Lamp as received Lamp as tested Lamp is measured in a type C goniometer coordinate system (reference IESNA LM 75). Lamp orientation is base up. Detector is 1000 mm from the lamp housing exit aperature. in full without permission of. Page 2 of 9
Report: LEDC001 010 WG 2.0 Scope of testing Photometric and electrical testing in accordance with IES LM 79 08 IES Approved Method for the Electrical and Photometric Measurements of Solid State Lighting Products. All measuremets are made using the goniometer spectroradiometer test method. 2.1 Test protocol and data reduction 1. Data is reported for the 360nm to 800nm spectral range with a 1 nm resolution. 3.0 Measurement coordinates for type C spectral goniometer in full without permission of. Page 3 of 9
Report: LEDC001 010 WG 4.0 Results Integrating Sphere Measurements Test Conditions Test Date: 1 Jan 11 Theta Minimum: 0.0 ± 0.10 Method: goniometer spectroradiometer Theta Maximum: 90.0 ± 0.10 x axis Alignment: 0.0 ± 0.001 m Theta Step Size: 2.5 ± 0.10 y axis Alignment: 0.0 ± 0.001 m Phi Minimum: 0.0 ± 0.10 z axis Alignment: 1 ± 0.001 m Phi Maximum: 337.5 ± 0.10 Phi Step Size: 22.5 ± 0.10 Optical Measurements Total Integrated Luminous Flux (lm): 954.069 Chromaticity Coordinates Luminous Efficacy (lm/w): 48.100 Cx: 0.3879 Correlated Color Temperature CCT (K): 3833 Cy: 0.3800 Color Rendering Index CRI, Ra: 85.3 u: 0.2287 R9: 19 v: 0.3360 Color Purity (%): u': 0.2287 Dominant Wavelength(nm): 580.0 v': 0.5041 Total Integrated Radiometric Flux (W): 3.115 Duv: 0.0005 Peak Wavelength (nm): 605.5 Δu'v': 0.0024 Electrical Measurements Active Power(W): 19.835 Average Voltage(V): 120.063 * Apparent Power (W): 25.758 Average Current (A): 0.2145 Power Factor: 0.77 Frequency (Hz): 60.0 * Set point Thermal Measurements Ambient Temperature ( C): Ambient Humidity (%RH): Sample Temperature ( C): 25.1 24.0 56.7 in full without permission of. Page 4 of 9
Report: LEDC001 010 WG 5.0 Charts 0.07 Spectral Irradiance (θ=0, Φ=0) Spectral Irradiance (W/m 2 *nm) Spectral Illuminance (lm/m 2 /nm) 0.06 0.05 0.04 0.03 0.02 0.01 0 40 35 30 25 20 15 10 5 360 410 460 510 560 610 660 710 760 Wavelength (nm) Spectral Illuminance (θ=0, Φ=0) 0 360 410 460 510 560 610 660 710 760 Wavelength (nm) in full without permission of. Page 5 of 9
Report: LEDC001 010 WG 6.0 Candela Plots Luminous intensity (cd) 4000 3500 3000 2500 2000 1500 1000 500 0 Luminous Intensity (cd) vs Angle (θ) *2 0 10 20 30 40 50 60 70 80 90 100 θ (degrees) 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 0 22.5 45 in full without permission of. Page 6 of 9
Report: LEDC001 010 WG 7.0 Zonal Lumen Summary Zonal Lumen Summary Lumens Per Zone Zone Lumens % Lamp Zone Lumens % Total 0 30 0 40 0 60 60 90 0 90 734.5 797.3 885.2 68.8 954 77.00% 83.60% 92.80% 7.20% 100.00% 0 10 41202 20 30 30 40 40 50 265.3 332.2 136.9 62.9 45.8 27.8% 34.8% 14.4% 6.6% 4.8% 50 60 42.1 4.4% 60 70 36.8 3.9% 70 80 80 90 24.3 7.7 2.5% 0.8% 8.0 Illuminance Plots in full without permission of. Page 7 of 9
Report: LEDC001 010 WG 9.0 Chromaticity Diagram CIE1931 Chromaticity Diagram Plankian Average Center in full without permission of. Page 8 of 9
Report: LEDC001 010 WG 10.0 Equipment and Reference Standard Description of Lamp Standard Operating Operating current Lamp standard type voltage (VDC) (A) Watts (W) Illuminance (lux) Calibration date Tungsten Halogen 115 8.00 1000 8364.0 04/05/2011 Calibration reference 0006389 01 Lamp Calibration Chain: Irradiance measurements are traceable to NIST through a 2nd generation lamp of known Irradiance maintained at. The calibration chain is given below. Generation Standard Report/File Number Calibration Date Description 1 s/n F 626 NIST# 844/278192 09 1/3/2011 NIST 1000W standard lamp Test Instrumentation Item Description /use Manufacturer Model Serial# Calibration due 2 Axis Type C Goniometer CA 10281 000 at use Spectroradiometer SP 75 2011433 25 Jan 12 Power Supply Kikusui PCR500M RB002844 13 Aug 12 Digital Power Meter Yokogawa WT210 91L122464 16 Feb 12 11.0 Additional Information END OF REPORT in full without permission of. Page 9 of 9