Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, RDT) Control of proportional, process and motor valves Bürkert proportional valves and flow meters are memorized 1/16 DIN size panel version Type 6223 Type 2301+8696 Type 8012 Type 8314 Type 8417 Type 8222 Proportional Valve Globe control valve system INLINE flow sensor Pressure transmitter RTD sensor neutrino transmitter Thanks to its compact design, the universal 8611 controller is especially designed for compact control system applications. It is compatible and tested with all Bürkert proportional valves and sensors and can be connected with every nonebürkert Control valve by standard signal (, or PWMoutput). The proportional & Integral (PI) process controller is equipped with many additional functions. The process value feedback can be supplied as one of three analog inputs; a standard signal (/010V), frequency or RTD signal; directly to the universal controller. The process switching points can be set via a or signal or with the keypad. For temperature specific control, it is possible to set a cascade structure with both temperature and flow as inputs. Thanks to the proportional control capabilities, a wide range of control functions can be performed in a variety of liquids and gas medias. Fields of application: Flow control, Ratio control Pressure control control Conductivity control ph control Level control General data Materials Housing, cover Front panel folio / Screws Multipin Wallmounting holder Display Electrical connections Voltage supply cable Environment Ambient temperature Relative humidity Standards and approvals Protection class Standard EMC, CE Approvals ULRecognized for US and Canada PC, +20% glass fibre Polyester / Stainless steel CuZn, nickelplated PVC Dualline 8digit LCD with backlight Multipin: M128pin, 4pin, 3pin Insert for connecting to components according to DIN EN 175301803 (previously DIN 43650, Form A). 0.5 mm 2 max. cross section, max. 100 m, shielded 0 C up to +70 C (operating and storage) 80%, without condensation IP65 EN 61326 610101 + CAN/CSAC22 No.610101 www.burkert.com p. 1/9
Electrical data Power supply Power consumption Input Setpoint Standard Standard Sensors Standard Standard Frequency Input 1 Input 2 Pt100 (2 wires) Binary input Outputs Continuous signal Discontinuous signal Binary output Power supply sensor / actuator Total load of all outputs Controller modes *) PWM = pulse width modulation PTM = pulse time modulation ±10%, filtered and regulated approx. 2 W (without valve without sensor input) Sourcing mode Max. input impedance: 70 Resolution: 5.5 A Max. input impedance: 11.5 k Resolution: 2.5 mv Sourcing mode Max. input impedance: 70 Resolution: 5.5 A Max. input impedance: 11.5 k Resolution: 2.5 mv External sensor min. 0.25 Hz / max. 1 khz input impedance: >1 k Signal type: Sinus, square, triangle pulse (> 3000 mvpp, max. 30 Vpp) Internal Hall sensor min. 0.25 Hz / max. 1 khz (only with Bürkert Type S030 flow fitting) Measuring range: 0 C...200 C Measuring current: 1 ma Measuring error: <0.5 C Input impedance: 10 k Operating threshold: 3 V30 V Max. frequency: 1 khz Standard signal max. loop resistance: 680 accuracy: 0.5% Standard signal max. current: 20 ma accuracy: 0.5% 2 transistor outputs for PWM *) or PTM *) signal Control frequency 1.2 khz20 Hz resolution max.: 16 Bit (depend from frequency) max. current load: 1.5 A switching voltage: Transistor output (PNP) (configurable) max. current load: 1.5 A switching voltage:, max. 1 A max. 1.5 A PIControl, 2 point and 3 point, cascaded Up to 2 Binary out with windows and hysteresis mode p. 2/9
Assembly versions 8611 Mounting on flowfitting Fittingmounting Mounting on a proportional valve Valvemounting 8611 8611 Mounting in panel Panelmounting 8611 Mounting on a wall Wallmounting Mounting on a rail Railmounting 8611 8611 Adaptor for Wallmounting Adaptor for Railmounting p. 3/9
Dimensions [mm] 8611 Fittingmounting DN [mm] H [mm] 06 79.5 08 79.5 15 84.5 20 82.0 25 82.2 32 85.8 40 89.6 50 95.7 65 98.7 8611 Valvemounting p. 4/9
Dimensions [mm] (continued) 8611 Panelmounting 54,2 66 44,5 76 29 8611 Wallmounting 8611 Railmounting p. 5/9
Connection feasibility and controller versions Assembly Flow sensor fitting mounting Wall and railmounting Valvemounting Sensor integrated HALLsensor, without external sensor input integrated HALLsensor with external sensor input without HALLsensor, with external sensor input without HALLsensor, with external sensor input Control Flow control control with flow display control with flow input for cascade control Ratio control control Pressure control Flow control control Pressure control Flow control 8pin 8pin M12 M12 8pin 8pin M12 M12 4pin 4pin 3pin 4pin 3pin 3pin 8pin M12 plug Power supply Set point value ( / ) Binary input process value output ( / ) PIcontrol output ( / ) Binary output 3pin plug Sensor input /, frequency or RDT Sensor power supply 4pin plug DIN 175301803 PIcontrol output : output output / output and power supply actuator (only 182 383) PWM output for Solenoid control valve Terminal block 1 Terminal block 2 Terminal block 3 Jumper 1 (NPN/PNP) Jumper 2 (NPN/PNP) p. 6/9
Ordering chart for universal Controller Type 8611 A controller Type 8611 consists of: for Fittingmounting an electronic module 8611 an INLINE fitting S030 (DN06 DN65) (Refer to corresponding data sheet has to be ordered separately) for Wallmounting an electronic module 8611 a wallmounting adaptor (included) for Railmounting an electronic module 8611 a railmounted adaptor (included) for Valvemounting an electronic module 8611 a proportional valve (Refer to corresponding data sheet of the proportional valve has to be ordered separately for Panelmounting an electronic module 8611 4 mounting brackets and 1 sealing (included) Mounting disposition externe Sensor input interne controller outputs (*) Power supply Setpoint setting Process value output Binary In/Out Fitting (Fitting S030) Wall Rail (RDT) Ratio or Temp. ( / ) Ratio (FrequencyNPN) (frequency NPN) (RDT) All sensors with standard signal ( / ) All sensors with standard signal ( / ) (frequency NPN) (RDT) All sensors with standard signal ( / ) (Fitting S030) (Fitting S030) (Fitting S030) 177 455 177 458 177 463 208 048 177 454 177 457 177 462 182 383 177 091 177 456 177 460 Mounting disposition Sensor input externe controller outputs Setpoint setting Process value output Binary In/Out Proportional valve (Pt100) (frequency NPN) All sensors with standard signal ( / ) 204 642 204 639 186 289 Mounting disposition Sensor input controller outputs Setpoint setting Process value output Binary In/ Out UL Recognition Panel 2 x Frequency (NPN/PNP) 1 x / 1 x RTD 2x PTM 1x / 2 x Bin Out * Either PWM/PTM or / selectable as PIcontrol output. If / selected as PIoutput, the process value isn't available. No ULRecognized 210 206 562 655 p. 7/9
Ordering chart for accessories (has to be ordered separately) Description Positioning system 8810 for pneumatic actuators with railmount adaptor 204 458 4pin female right angle connector with selflocking threaded joint and 2 m molded cable (valve output) 918 718 4pin female right angle connector with selflocking threaded joint and 5 m molded cable (valve output) 919 412 3pin female right angle connector with selflocking threaded joint and 2 m molded cable (sensor input) 918 717 3pin female right angle connector with selflocking threaded joint and 5 m molded cable (sensor input) 919 410 4pin female connector, straight with snapon connection and 2 m molded cable (valve output) 919 060 3pin female connector, straight with snapon connection and 2 m molded cable (sensor input) 918 039 8pin M12 female connector, straight with screw connection and 2 m molded cable (PUR) (Power supply) 919 061 8pin M12 female connector, straight with screw connection, to assemble (Power supply) 918 998 2pin female connector, straight with 3 m cable (for connection to Positioning system 8810) 133 486 2pin female connector,straight with 5 m cable (for connection to Positioning system 8810) 167 494 2pin female connector, straight with 0.3 m wire (for connection to Positioning system 8810) 644 068 2pin female connector, straight with 0.6 m wire (for connection to Positioning system 8810) 162 144 Ordering chart for spare parts (has to be ordered separately) Description Wallmounting adaptor 427 098 Railmounting adaptor 655 980 Mounting brackets (Set of 4 pieces) 560 225 p. 8/9
Examples of applications Cascaded temperature control with process control valve Positioning system Type 8810 Process control valve Type 2712 or 2012C Flow control with process control valve Positioning system Type 8810 P RDT sensor Type 8417 P Flow sensorfitting Type S030 with Controller Type 8611 (fitting mounted version) Bloc with integrated Flow sensorfitting Type S030, Process control valve Type 2012C and Controller Type 8611 control with solenoid control valve controller Type 8611 (wallmounted version) Multi channel solution with process control valve Solenoid control valve Type 2835 RDT sensor Type 8417 with solenoid control valve *To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1109/11_EUen_00895018 p. 9/9