CX-1 digital retinal camera mydriatic & non-mydriatic. Redefining true versatility.

Similar documents
you can We have an eye for detail. CF-1 HIGH RESOLUTION DIGITAL RETINAL CAMERA Camera Canon EOS 1Ds Mark III f7.1 1/800 ISO 320

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

Going beyond the surface of your retina

CR-2 AF DIGITAL NON-MYDRIATIC RETINAL CAMERA. Superior Image Resolution and Auto Functionality

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

The First True Color Confocal Scanner on the Market

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Impressive Wide Field Image Quality with Small Pupil Size

The First True-Color Wide-Field Confocal Scanner

The First True Color Confocal Scanner

Optical Coherence Tomography Retina Scan Duo

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

Optical Coherence Tomography. RS-3000 Advance 2

Kowa nonmyd WX 3D. 2D/3D non-mydriatic retinal camera. Now approved by the NDESP.

TRC-NW400 Non-Mydriatic Retinal Camera

Optical Coherence Tomography. RS-3000 Advance

Optical Coherence Tomography. RS-3000 Advance / Lite

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

Version 1.0. th March 2011

you can Portable Digital Radiography. Going places. CXDI-501G DIGITAL RADIOGRAPHY SYSTEM

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Coherence Tomography. RS-3000 Advance / Lite

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

Wide Angle Ophthalmoscope Instructions

Our vision is foresight

Keeler Direct Ophthalmoscopes

The ultimate in 4K laser projection

Instruments Commonly Used For Examination of the Eye

Digital Wide-field Imaging System

Non-Mydriatic Auto Fundus Camera AFC-330

Kinder products for your most precious patients

Training Eye Instructions

GE Healthcare. Essential for life. Senographe Essential Full-Field Digital Mammography system

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Image Database and Preprocessing

Non-Mydriatic Auto Fundus Camera AFC-330

DRCR.net Image Acquisition Protocol

DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000

Solutions Page Content ImagePilot. Primary keywords: Digital radiography Computed radiography Image viewing and storage

The Confocal Tonal Shift

RETINOPATHY SCREENING GUIDE

Slit Lamp Adapted Optical Coherence Tomography SL SCAN-1 CONNECTING VISIONS

Basic Principles of the Surgical Microscope. by Charles L. Crain

NEWTOM GO 2D GREAT.VISION

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

SLIT LAMP BQ 900 Sophisticated microscopy

HEINE Direct Ophthalmoscopes

SPECTRALIS Training Guide

Smart-Device Ophthalmic Photography

CR-2 AF. Operation Manual. Digital Retinal Camera

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Nikon Launches All-New, Advanced Nikon 1 V2 And Speedlight SB-N7. 24/10/2012 Share

YSF - 300/DAR i

CONDENSED POWER COMPARISON SHEET

Beautifully Crafted Slit Lamps

R&F X-ray systsem. Savings With Every Exposure

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

OCULUS ImageCam 2. Slit lamp documentation. We focus on progress

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Things you may want to know

Advanced performance compact cameras to take your photography to the next level.

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

Biology 70 Slides for Lecture 1 Fall 2007

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol. Version /14/14

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

inphoto ID Canon camera control software Automatic ID photography User Guide

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Progeny Imaging Veterinary

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Professional Optometric Student Guide

<Motion Panorama> 180 Vertical : 2160 x 9600 Horizontal : 9600 x Vertical : 2160 x 6400 Horizontal : 6400 x 1440

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

This has given you a good introduction to the world of photography, however there are other important and fundamental camera functions and skills

Image Modeling of the Human Eye

Information. The next-generation flagship Nikon digital-slr camera with the ultimate in versatility and functionality

OCT - Anatomy of a Scan. OCT - Anatomy of a Scan. OCT Imaging. OCT Imaging

Operating Manual. CenterVue EIDON Operating Manual Pag. 1 di 69

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

SmartRAD. Advanced Digital Radiography System

Stereo Viewing Systems

Beautifully Crafted Slit Lamps

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos 200Tx Imaging Protocol. Version 3.0 9/19/16

Understanding your Direct Ophthalmoscope

Lecture 2 Slit lamp Biomicroscope

Dust reduction filter. Live View

The A-Scan Plus. Cataract Surgeons who do their homework...get an A-Plus. Product #

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software.

PLD5600A High Frequency Digital Gastrointestinal &DR System(630mA)

THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY.

CHAPTER 4 LOCATING THE CENTER OF THE OPTIC DISC AND MACULA

2Win Binocular Mobile Refractometer and Vision Analyzer

Better diagnosis and treatment all-in-one.

Catalogue No. 109, valid as of May The Full HD Video Colposcope

Transcription:

CX-1 digital retinal camera mydriatic & non-mydriatic Redefining true versatility.

Redefining True versatility The multifaceted CX-1 The CX-1 is a Mydriatic Retinal Camera with full Non-Mydriatic functionality. Besides color photography, the CX-1 is equipped with high quality optical filters for FLUO, Red Free, Cobalt and standard even with FAF photography. The CX-1 can be changed into a NM camera by a simple push of a button. The Non- Mydriatic mode is essential for non dilatable patients such as glaucoma suspects. Children and photosensitive patients will also benefit from the non invasive IRED observation light. Dedicated EOS camera Canon has used their expertise in digital camera technology to create a unique digital EOS camera dedicated to ophthalmic photography: Completely integrated with the functions of the CX-1 to assist in easy image acquisition. Vari-angle LCD screen For ergonomic observation. All photography modes can be performed in the MYD and NON MYD mode. This provides exceptional versatility and enables diagnosis, screening and monitoring of all major eye diseases External monitor The IR observation image on the EOS screen can be viewed on an external larger monitor in full HD. Simply connect a HDMI cable to the EOS. MYD mode Observation by viewfinder Visible observation light NON MYD mode Observation by EOS screen Invisible IR observation light Easy panning and tilting For working around central obstructions (cataracts, vitreous hemorrhages) and imaging the peripheral retina for creating large mosaic images effortlessly.

Easy operation Compact device For maximal patient interaction. Easy to observe patient. Extensive Photography Modes Sophisticated optical filters for highest image quality All photography modes are available in MYD or NON-MYD mode. Color Base Line Cobalt Visualizing Nerve Fiber Layer, important for checking for Glaucoma Short reaching distance for easy opening patient s eyelid. Fluo Checking retinal flow for occlusions and leakages Red free Useful for checking the condition of the blood vessels, important for detecting Diabetic Retinopathy FAF FAF Imaging for the diagnosis of retinal disease is a relatively new diagnostic technique that provides more information on the health of the retinal pigment epithelium. FAF has proven to be very useful for the early detection of age related Macula Degeneration (AMD), one of the leading causes of visual impairment. Recent studies indicate that FAF Imaging can also aid in the diagnosis of a variety of other diseases and even in the detection of intraocular tumors. Diabetic retinopathy Occlusion AMD Motorised filters; easy to operate and protected from dust. Motorized chin rest for easy adjustment. Automatically optimized flash range The CX-1 has an automatically optimised flash range, - adjusted to the different photography modes and ISO settings. It will help you by automatically selecting one of the 168 possible flash settings.

Unrivalled Image quality Dedicated 24 Mega Pixel EOS camera Canon s own EOS camera technology, with its renowned image processing capabilities, is adapted exclusively for Canon retinal cameras, it provides optimal retinal imaging. Canon Opacity Suppression When obtaining retinal images, ocular opacities can cause several problems. Canon opacity suppression tool is a unique and sophisticated software tool, that based on information from the EOS CMOS sensor will largely suppress the effect of ocular opacities on color images. Ocular opacities The scattering of the light will make the edges of the blood vessels appear blurred The difference in brightness of the retina will be reduced, making it very difficult to distinguish between structures A cataract eye will cause images to appear more yellow With Canon Opacity Suppression The original brightness and color of the retina will be restored The blood vessels will appear much clearer Original image CANON OPACITY SUPPRESSION Original image CANON OPACITY SUPPRESSION With Canon Opacity Suppression (COS) the effect of ocular opacities will be largely suppressed : previously unsuitable images could now provide you with essential clinical information. 4

Canon Retinal Expert software RX Extensive software tools Emboss Negative The blood vessels stand out. Emboss Positive The optic disc stands out. The new software platform for Canon retinal cameras and OCT. Designed for seamless integration and connectivity with patient management systems. Extremely intuitive user interface Inversion Inverts the color of an image to assist diagnosis. Overlay Overlay 2 images to see differences and changes in pathology. Compare both eyes or studies from different dates Annotations Add shapes and texts to a captured image. Cup/disc measurement Measure the optic nerve papillary area. Observe progression; select up to 5 past examinations Loupe function To assist diagnosis. Mosaic function Up to 20 images can be combined (optional feature).

Canon Retinal Expert Software Platform RX Seamless integration with patient management systems Stand alone configuration All-in one system. Capturing, viewing and database RX Viewer Reviewing Reporting Optional RX Viewers can be connected over the network and access the database of the device. Up to 2 RX viewers can access the database at the same time. The Canon RX software can automatically start the patient management software on the selected patient and vice versa. (Command Line Interface) Third party software can start the Canon RX software Practice management software RX Software RX Software shows data of that patient Capturing Reviewing and reporting Database and archive RX Viewer Reviewing Reporting Command with patient information A CX-1 could be added to a Canon OCT in a standalone configuration, sharing the same PC and database. Analysis results of both devices can be combined in one combined report. Network configuration With a RX Server up to 5 systems can be connected with maximum 10 concurrent viewers. RX Server RX Viewer RX Viewer RX Viewer RX Viewer General Data Protection Regulation (GDPR) RX server and RX viewers have to be purchased separately. To comply with the GDPR regulation, the RX software was updated with several new features: Anonymisation Anonymising patient personal data: for printing, exporting or saving data. User s authority management Additional user accounts, with different privilege levels, to limit data mismanagement and other operation mistakes. Central account management with LDAP LDAP (Leightweight Directory Access Protocol) is used to control users from a central location; e.g. setting password rules, locking account for security reasons. Extended logging ability As an option, any user activity in creating, modifying and deleting medical information or data can be logged. Canon RX software can start third party software RX Software Program launch preset keys Versatile Patient data input possibilities for optimal integration Input data manually Import a list from the practice management system Use a Modality worklist (in a DICOM environment) Image Import Import images from other devices and save them into the database together with the other diagnostic information of the patient. 1 2 3 Command with patient information Third party software opens on that patient RX software is fully DICOM compatible

Specifications CX-1 Dimensions 320 W x 531 D x 577 H mm, 26 kg Focus Adjustment Split Lines Angle of view Minimum pupil size Working Distance MYD: 50 degrees, Non-Myd: 45 degrees 2 X magnification (digital) Myd: ø5.1mm (SP mode ø 4.3mm) Non-Myd: ø4.3mm (SP mode ø 3.8mm) 35mm Photography modes Colour /FA /Red Free /Cobalt and FAF Working distance Panning and Light sources Corneal Reflection dots adjustment 30 degrees to the left and right tilting range 15 degrees up, 10 degrees down Xenon tube for photography Halogenlamp for observation (Myd mode) IRED LED for observation (Non-Myd mode) Mounted camera Flash levels Patient s diopter Dedicated digital EOS camera (24 MegaPixel for current model) HDMI Output for external monitor Full HD resolution 168 steps 31D ~ 7D, 10D ~+15D (standard) compensation +11D ~+33D Fixation targets External Internal LED dot matrix for Non-Myd mode ( 70 points ) Internal fixation target for Myd mode (optional) Optional accessories Stereo Unit SU-1 Internal eye fixation (CX-IF) Chin rest paper (500 sheets) Images courtesy of: Karolinska Institutet, Sweden Semmelweis University, Hungary Máxima Medisch Centrum, Netherlands 2097V720 Canon Europa N.V. Bovenkerkerweg 59 1185 XB Amstelveen The Netherlands www.canon-europe.com/medical DISCOVER THE NEW CANON EDUCATIONAL COMMUNITY AT WWW.EYELEARNING.ORG