Comparison of Microwave Breast Cancer Detection Results with Breast Phantom Data and Clinical Trial Data: Varying the Number of Antennas

Similar documents
COST-SENSITIVE ENSEMBLE CLASSIFIERS FOR MICROWAVE BREAST CANCER DETECTION. Yunpeng Li, Adam Santorelli, Olivier Laforest and Mark Coates

Investigation of Classification Algorithms for a Prototype Microwave Breast Cancer Monitor

University of Bristol - Explore Bristol Research. Link to published version (if available): /LAWP

Investigation of Classifiers for Tumor Detection with an Experimental Time-Domain Breast Screening System

Time-Domain Microwave Radar Applied to Breast Imaging: Measurement Reliability in a Clinical Setting

A Wearable Microwave Antenna Array for Time-Domain Breast Tumor Screening

Microwave Medical Imaging

Improved Confocal Microwave Imaging Algorithm for Tumor

PERFORMANCE AND ROBUSTNESS OF A MUL- TISTATIC MIST BEAMFORMING ALGORITHM FOR BREAST CANCER DETECTION

Simulation Measurement for Detection of the Breast Tumors by Using Ultra-Wideband Radar-Based Microwave Technique

Progress In Electromagnetics Research, Vol. 107, , 2010

A Preprocessing Filter for Multistatic Microwave Breast Imaging for Enhanced Tumour Detection

COMPARISON OF PLANAR AND CIRCULAR ANTENNA CONFIGURATIONS FOR BREAST CANCER DETECTION USING MICROWAVE IMAGING

Evaluation of the Mono-static Microwave Radar Algorithms for Breast Imaging

DATA INDEPENDENT RADAR BEAMFORMING ALGORITHMS FOR BREAST CANCER DETECTION

SAR Distribution in Microwave Breast Screening: Results with TWTLTLA Wideband Antenna

MICROWAVE BREAST imaging has been proposed to. A New Breast Phantom with a Durable Skin Layer for Microwave Breast Imaging

A Flexible Broadband Antenna and Transmission Line Network for a Wearable Microwave Breast Cancer Detection System

Recent Progress in Ultra-Wideband Microwave Breast Cancer Detection

13 Bellhouse Walk, Bristol, BS11 OUE, UK

MICROWAVE IMAGING TECHNIQUE USING UWB SIGNAL FOR BREAST CANCER DETECTION

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to published version (if available): /EuCAP.2016.

Interaction of an EM wave with the breast tissue in a microwave imaging technique using an ultra-wideband antenna.

530 IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 63, NO. 3, MARCH 2016

UWB IMAGING FOR BREAST CANCER DETECTION USING NEURAL NETWORK

TRANSMITTER-GROUPING ROBUST CAPON BEAM- FORMING FOR BREAST CANCER DETECTION

A modified Bow-Tie Antenna for Microwave Imaging Applications

Compact Dual-Polarized Quad-Ridged UWB Horn Antenna Design for Breast Imaging

A Low Cost and Compact RF Switching System for Wearable Microwave Head Imaging with Performance Verification on Artificial Head Phantom

Bayesian Estimation of Tumours in Breasts Using Microwave Imaging

A Compact UWB Printed Antenna with Bandwidth Enhancement for In-Body Microwave Imaging Applications

3D radar imaging based on frequency-scanned antenna

Progress In Electromagnetics Research B, Vol. 24, 1 15, 2010

A Breast Cancer Detection Approach Based on Radar Data Processing using Artificial Neural Network

Challenges in the Design of Microwave Imaging Systems for Breast Cancer Detection

Microwave Near-field Imaging of Human Tissue: Hopes, Challenges, Outlook

Helbig, Marko; Dahlke, Katja; Hilger, Ingrid; Kmec, Martin; Sachs, Jürgen: Design and test of an imaging system for UWB breast cancer detection

A Printed Vivaldi Antenna with Improved Radiation Patterns by Using Two Pairs of Eye-Shaped Slots for UWB Applications

A Compact UWB Antenna Design for Tumor Detection in Microwave Imaging Systems

A Matching-Pursuit Based Approach for Detecting and Imaging Breast Cancer Tumor

Review Article Recent Advances in Microwave Imaging for Breast Cancer Detection

MICROWAVE IMAGING BASED ON WIDEBAND RANGE PROFILES

BREAST cancer is a significant health issue for women and

UWB/Omni-Directional Microstrip Monopole Antenna for Microwave Imaging Applications

Short Interfacial Antennas for Medical Microwave Imaging

SIZE REDUCTION AND BANDWIDTH ENHANCEMENT OF A UWB HYBRID DIELECTRIC RESONATOR AN- TENNA FOR SHORT-RANGE WIRELESS COMMUNICA- TIONS

BREAST cancer persists to be the top threat to women s

Research Article A Directional Antenna in a Matching Liquid for Microwave Radar Imaging

A Novel Transform for Ultra-Wideband Multi-Static Imaging Radar

Tissue Mimicking Materials for Multi-modality Breast Phantoms

Study on the frequency-dependent scattering characteristic of human body for a fast UWB radar imaging algorithm

Research Article Microwave Radar Imaging of Heterogeneous Breast Tissue Integrating A Priori Information

A Very Wideband Dipole-Loop Composite Patch Antenna with Simple Feed

Conformal Microwave Tomography using a Broadband Non-Contacting Monopole Antenna Array

ENHANCEMENT OF PRINTED DIPOLE ANTENNAS CHARACTERISTICS USING SEMI-EBG GROUND PLANE

Computational Validation of a 3-D Microwave Imaging System for Breast-Cancer Screening

Research Article Medical Applications of Microwave Imaging

ANALYSIS OF ELECTRICALLY SMALL SIZE CONICAL ANTENNAS. Y. K. Yu and J. Li Temasek Laboratories National University of Singapore Singapore

A Compact Dual Band-Notched Ultrawideband Antenna with λ/4 Stub and Open Slots

MODERN AND future wireless systems are placing

2x2 QUASI-OPTICAL POWER COMBINER ARRAY AT 20 GHz

RECTANGULAR SLOT ANTENNA WITH PATCH STUB FOR ULTRA WIDEBAND APPLICATIONS AND PHASED ARRAY SYSTEMS

Simulation Design and Testing of a Dielectric Embedded Tapered Slot UWB Antenna for Breast Cancer Detection

An Improved Technique to Predict the Time-of-Arrival of a Tumor Response in Radar-based Breast Imaging

A MINIATURIZED INTERNAL WIDEBAND ANTENNA FOR WIRELESS USB DONGLE APPLICATION

A Simple Ultra-Wideband Magneto-Electric Dipole Antenna With High Gain

IT IS of practical significance to detect, locate, characterize,

A Novel UWB Antenna with Multiple Notched Bands for WiMAX and WLAN Applications

Slotted Octagonal shaped Antenna for Wireless Applications

PULSE PRESERVING CAPABILITIES OF PRINTED CIRCULAR DISK MONOPOLE ANTENNAS WITH DIFFERENT SUBSTRATES

Keywords: Bone cancer; patch antenna; ultra-wideband; return loss; micro strip line.

EVALUATION OF LIMESTONE LAYER S EFFECT FOR UWB MICROWAVE IMAGING OF BREAST MODELS USING NEURAL NETWORK

Design of UWB Monopole Antenna for Oil Pipeline Imaging

AMONG planar metal-plate monopole antennas of various

Design of Components for a Compact Ultra Wideband Microwave Imaging System

DESIGN OF A NOVEL WIDEBAND LOOP ANTENNA WITH PARASITIC RESONATORS. Microwaves, Xidian University, Xi an, Shaanxi, China

Broadband Microphone Arrays for Speech Acquisition

SAFETY ASSESSMENT OF BREAST CANCER DETECTION VIA ULTRAWIDEBAND MICROWAVE RADAR OPERATING IN PULSED-RADIATION MODE

State and Path Analysis of RSSI in Indoor Environment

A Novel Reconfigurable Spiral-Shaped Monopole Antenna for Biomedical Applications

QUADRI-FOLDED SUBSTRATE INTEGRATED WAVEG- UIDE CAVITY AND ITS MINIATURIZED BANDPASS FILTER APPLICATIONS

Confocal Microwave Imaging for Breast Cancer Detection: Localization of Tumors in Three Dimensions

UWB SHORT RANGE IMAGING

Printed UWB MIMO Antenna with Different Polarizations and Band-Notch Characteristics

ANTENNA DESIGN FOR WEARABLE MEDICAL DEVICES USING MBAN BAND

On-chip antenna integration for single-chip millimeterwave FMCW radars Adela, B.B.; Pual, P.T.M; Smolders, A.B.

PRINTED BLUETOOTH AND UWB ANTENNA WITH DUAL BAND-NOTCHED FUNCTIONS

SMART UWB ANTENNA FOR EARLY BREAST CANCER DETECTION

A Compact Miniaturized Frequency Selective Surface with Stable Resonant Frequency

ISSN: [Sherke* et al., 5(12): December, 2016] Impact Factor: 4.116

Broadband transition between substrate integrated waveguide and rectangular waveguide based on ridged steps

R. Zhang, G. Fu, Z.-Y. Zhang, and Q.-X. Wang Key Laboratory of Antennas and Microwave Technology Xidian University, Xi an, Shaanxi , China

DUAL-WIDEBAND MONOPOLE LOADED WITH SPLIT RING FOR WLAN APPLICATION

X. Li, L. Yang, S.-X. Gong, and Y.-J. Yang National Key Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi, China

A New Dual Band E-shaped Slot Antenna Design for Wireless Applications

THERMAL NOISE ANALYSIS OF THE RESISTIVE VEE DIPOLE

A PERTURBED CIRCULAR MONOPOLE ANTENNA WITH CIRCULAR POLARIZATION FOR ULTRA WIDEBAND APPLICATIONS

IEEE Antennas and Wireless Propagation Letters. Copyright Institute of Electrical and Electronics Engineers.

Speech Enhancement Using Beamforming Dr. G. Ramesh Babu 1, D. Lavanya 2, B. Yamuna 2, H. Divya 2, B. Shiva Kumar 2, B.

Antennas and Propagation for Body-Centric Wireless Communications

Transcription:

Comparison of Microwave Breast Cancer Detection Results with Breast Phantom Data and Clinical Trial Data: Varying the Number of Antennas Yunpeng Li, Adam Santorelli, Mark Coates Dept. of Electrical and Computer Engineering, McGill University, Montréal, Québec, Canada yunpeng.li@mail.mcgill.ca, adam.santorelli@mail.mcgill.ca, mark.coates@mcgill.ca Abstract Over the last two decades, microwave breast cancer detection has attracted an increasing amount of research attention and various research groups have recently commenced clinical testing. Much of the past assessment of algorithms and hardware has relied on breast phantoms. We illustrate in this paper through experimental data collected with breast phantoms that classification with breast phantoms can be a much easier task than that with clinical trial data (with numericallysimulated tumour responses). One antenna pair is sufficient to achieve almost perfect classification on the phantom data but has little success with the clinical trial data. The results demonstrate that we should exercise caution when evaluating classifier permance based solely on breast phantoms, and highlight the importance of validating microwave breast cancer detection algorithms with clinical trial data. Index Terms microwave breast cancer detection, clinical trial, breast phantom, ensemble classifier. I. INTRODUCTION Microwave breast cancer detection techniques have been proposed as a complementary modality breast cancer screening. They promise non-invasive screening with low-cost system fabrication and operation. These scans are conducted without breast compression and can be repeated frequently since no ionizing radiation is used. Research on the signal processing aspect of microwave breast cancer detection has primarily focused on generating images or building detection techniques specific system setups. Numerous imaging approaches [1], [2], [3], [4] were initially validated with numerical breast models. Subsequently, research groups across the globe built a variety of microwave prototypes with different configurations. A 16- element monopole antenna clinical prototype was built tomographic imaging at Dartmouth College [5]. At University of Bristol, multiple generations of microwave systems with 16, 31, and 64-element antenna arrays were constructed phantom testing and clinical trials [6], [7]. A 16-antenna time-domain microwave system [8] was developed at McGill University, tested with breast phantoms and clinical trials. Instead of being equipped with an increasing number of antennas, some recent microwave prototypes were built with one monostatic transceiver [9], [10] or one antenna pair [11]. In the last decade, microwave breast cancer detection algorithms based on machine learning techniques were developed. But they have been mainly evaluated using experimental data derived using breast phantoms [12], [13]. Because different teams developed their own prototypes with different system characteristics, it is difficult to compare results from different groups. [9] reports 90% accuracy on benign and malignant tumour classification with a set of breast and tumour phantoms and a single monostatic antenna, and [11] reports close to 100% tumour detection rate with two antennas. Two questions arise naturally: (i) do the phantombased experiments reported in [9], [11] sufficiently represent a clinical scanning scenario to provide a meaningful test of a classification technique? (ii) is it really necessary to develop systems with more than 2 antennas? The answers to these questions are important. Using a smaller number of antennas leads to more cost-effective equipment solutions with smaller m factors. If the classification task with breast phantoms is too simple compared to the task on clinical trial data, then we should strive to develop more realistic phantoms, devise a different experimental procedure, or interpret phantombased results with care and conduct algorithm validation using clinical trial data sets. Recently, together with the other members of the McGill University microwave breast cancer detection research group, we conducted a set of experiments involving both breast phantoms and clinical trials. The experimental methods and primary analysis of the results were reported in [14], [15]. For the experiments with breast phantoms, we made the data acquisition process as close to the practical clinical trial as possible, by collecting different scans on different days, and removing and re-inserting phantoms each scan. This is in contrast to the fixed phantom position scenario used in the experiments reported in [9], [11]. The clinical trial data were collected over a 8-month span [14]. Each volunteer was scanned multiple times, with a minimal interval between scans of one month. This data was collected from healthy patients, so in order to use it the evaluation of classifier algorithms, we incorporate numerically-simulated tumour responses. In light of the experimental results reported in [9], [11], this paper we revisited our experimental data. We examined how the permance of classification algorithms changes when they process measurements from only subsets of the 16 antennas available in the microwave system. This allows us to assess how many antennas are really necessary bee

Antenna Array Radome Data Recording Control Switching Matrix Module Pulse Generator + Oscilloscope + Clock Fig. 1. The experiment system we use to collect measurements. classification becomes viable. We compare the results the phantom data with those from the clinical data in order to assess whether the phantom-based testing is adequately representing the clinical measurement setting. The rest of the paper is organized as follows: Section II presents the microwave system, and the data acquisition process. Detection algorithms are presented in Section III. We present and discuss experimental results in Section IV. Concluding remarks are made in Section V. II. SYSTEM OVERVIEW AND DATA COLLECTION A. System overview The system (Figure 1) uses a 16-element antenna array to transmit and record pulses to and from the breast. The antennas are resistively loaded sensors which are designed microwave breast cancer detection [16]. The antenna array is embedded on the hollowed-out dielectric radome which also houses the breast or the breast phantom. When a breast scan starts, a short-duration Gaussian-modulated pulse concentrated in the 2-4GHz range [17] is propagated into the breast and collected by a receiving antenna specified by a switching matrix. An equivalent-time sampling oscilloscope records and saves the pulse to a computer. This process is repeated each antenna pair a total of 240 pulses are obtained one breast scan. B. Breast phantom data set We constructed 9 breast phantoms with varying dielectric properties. Three are heterogeneous and contain mixtures that mimic the dielectric properties of skin, gland, fat and tumour. The construction process is described in [15]. Those three phantoms are rotated by 120 and 240 to mimic 6 new phantoms, as different structures are presented to the measurement system after the rotation. Thus, we have 15 phantoms in total. 14 of these phantoms contain a plug position so we can insert either the fat plug or the tumour plug to mimic the tumour-free or the tumour-bearing breasts. We collected 10 sets of scans on tumour-free phantoms and 10 sets of scans on tumour-bearing phantoms. Each phantom is removed from the radome once a scan is completed. Scans on the same phantom are permed in different days with the system being re-initialized each day. These steps are used to introduce variations common in a real clinical trial data collection process. C. Clinical trial data set We permed breast scans on 12 healthy volunteers over an 8 month span. Their ages ranged from 21 to 77, and the bra cup sizes varied from A to D. Each volunteer visited a minimum of two and a maximum of six times, with the visit interval being at least one month. As scans are permed on both breasts, a total of 96 scans were collected in 48 volunteer visits. Since all volunteers are healthy, we insert numerically simulated tumour responses into the clinical trial data set. The detailed description of the data-adaptive tumour response construction that factors in the heterogeneous propagation environment inside the breast is described in [18]. Tumour responses with attenuation factor 1 are inserted in the data set we analyze in this paper. III. CLASSIFICATION METHODS In this section, we describe the classification algorithms that we compare, and provide details concerning the antenna configurations that are examined. 1) Imaging-based detection algorithm: The delay-multiplyand-sum (DMAS) algorithm [2] is a popular method to generate images from microwave breast cancer screening data. It first extracts backscatter from pulses received in each antenna pair. For each voxel position, the time delays with each antenna pair are estimated and the time-aligned backscatter are multiplied in a pairwise fashion. This is followed by a summing and integration operation which outputs the image intensity at each voxel. We proposed in [19] to use the maximum image intensity as the classifier input the detection task. The maximum image intensity is compared with a threshold to decide whether a tumour is present. 2) Ensemble algorithm: The ensemble algorithm microwave breast cancer detection is proposed in [18]. Principal component analysis (PCA) is first applied to measurements from each antenna pair feature extraction. 2µ-support vector machines (SVM) [20] with different hyperparameter values are then trained on the extracted features from each antenna pair. These trained base models m a model library the base models include 2ν-SVMs trained using different antenna pairs and those the same antenna pair but with different hyper-parameter values. The ensemble algorithm selects the best base models by evaluating the achieved cross validation error, to create an ensemble of more effective models. They are used to classify the test data and reach a final detection decision using a majority vote across the decisions of all model in the ensemble. The process is described in Figure 2. 3) Antenna configuration: Our current system consists of 16 antennas. To investigate the impact of the number of antennas on classification error, we perm classification using the measurements recorded by different subsets of the 16 antennas. Configurations with 16, 8, 4 or 2 antennas are investigated. Experiments are designed so that different relative geometric relations between antennas are explored in different experiments.

N data Channel 1 Channel 1 M antenna pairs N data Channel 2 Channel 2... PCA... Base models Base models... Base models Ensemble N data Channel M Channel M N x 1 vectors d x 1 vectors set. The number of retained is 30, and the number of best base models retained in ensemble is set to Q = 100. We perm parameter the 2ν-SVM using cross validation over values listed in Table I. The number of folds of cross validation is 14 the breast phantom data set and 11 the clinical trial data set, both being equal to the number of phantoms or volunteers in the training data set. Each fold contains all data from one breast phantom or one volunteer. We do not need to specify the value of the intensity threshold the DMAS-based classification algorithm as we examine its permance when varying the value of the threshold. TABLE I CANDIDATE PARAMETER VALUES USED IN THE ENSEMBLE SELECTION ALGORITHM. Fig. 2. Selected base models Majority vote +1/-1 The classification procedure based on ensemble. γ 2 15, 2 13,..., 2 5 ν + 1 10 5, 3 10 5, 1 10 4, 3 10 4, 0.001, 0.003, 0.01, 0.03, 0.1, 0.2, 0.3..., 1 ν 1 10 5, 3 10 5, 1 10 4, 3 10 4, 0.001, 0.003, 0.01, 0.03, 0.1, 0.2, 0.3..., 1 r 0.4, 0.3,..., 0.4 To facilitate the grouping of antennas, we categorize antennas into four groups, using the antenna indices shown in Figure 3: Z 1 = {1, 5, 9, 13}, Z 2 = {2, 6, 10, 14}, Z 3 = {3, 7, 11, 15}, Z 4 = {4, 8, 12, 16}. Antennas in the same group have the same z coordinates. The antennas used in each experiment are listed in Table II. Fig. 3. Positions of antennas A1 to A16 (blue) correspond approximately to the locations in our experimental system. IV. RESULTS For the breast phantom data set, we use all of the data from one phantom as the test data; the clinical trial data set, we use all data from one volunteer as the test data, We use all of the measurements from the other phantoms or volunteers as the training data. So, 15 training-testing pairs are constructed the breast phantom data set, and 12 the clinical trial data Table II presents the area under curve (AUC) values of the average receiver operating characteristic (ROC) among all training-test pairs, classification with different antenna configurations. An AUC with value 1 corresponds to perfect classification, while 0.5 indicates a permance similar to a random guess. With breast phantoms, we observe very high detection rate using the ensemble algorithm any combination of antennas tested in the experiment. When the number of antennas used is 2, ensemble algorithm does not select antennas since only one antenna pair is available. This shows that almost every antenna pair records measurements that contain enough inmation the detection algorithm to make very accurate classification. The DMAS-based algorithm on breast phantoms has poor permance, and its AUC values are not significantly different than that of random guess most antenna configurations tested. This is probably due to poor model matching and data alignment challenges. We have constructed heterogeneous phantoms, and attempted to make the data collection process similar to that of the clinical setting, by conducting different scans of the same phantom in different days, removing and replacing the breast phantoms from the radome, and re-initializing the microwave system bee each day s collection. But even with all these efts to mimic the complexities encountered when working with human patients, the data set with breast phantoms suggests that sufficient inmation is obtained by a single antenna pair the ensemble algorithm to achieve almost perfect classification. For the clinical trial data set, the ensemble algorithm achieves an AUC of 0.81 using all 16 antennas. Occasional decrease of detection permance is observed antenna configurations with 4 or 8 antennas. The difference

TABLE II AREA UNDER CURVE (AUC) FOR EACH ANTENNA COMBINATIONS Experiment indice # antenna 1 16 2 Antenna indices {Z 1, Z 2, Z 3, Z 4 } Phantom data ensemble Clinical trial data DMAS ensemble DMAS 0.99 0.52 0.81 0.56 {Z 1, Z 2 } 0.99 0.68 0.81 0.54 3 {Z 1, Z 3 } 0.99 0.64 0.81 0.57 4 {Z 1, Z 4 } 0.99 0.53 0.86 0.60 5 {Z 2, Z 3 } 1.00 0.72 0.74 0.49 6 8 {Z 2, Z 4 } 0.99 0.36 0.78 0.46 7 {Z 3, Z 4 } 0.99 0.36 0.56 0.43 8 9 10 11 {1,2,7,8, 9,10,15,16} {1,3,6,8, 9,11,14,16} {1,4,6,7, 9,12,14,15} 0.99 0.49 0.87 0.54 0.99 0.63 0.85 0.58 0.99 0.67 0.78 0.56 Z 1 1.00 0.43 0.82 0.57 12 Z 2 0.99 0.49 0.76 0.47 13 Z 3 0.98 0.61 0.58 0.47 14 4 Z 4 0.98 0.63 0.52 0.42 15 {1, 6, 9, 14} 0.98 0.45 0.80 0.53 16 {1, 7, 9, 15} 0.99 0.35 0.82 0.52 17 {1, 8, 9, 16} 0.99 0.65 0.85 0.62 18 {1,2} 0.99 0.54 0.52 0.55 19 {2,3} 0.97 0.52 0.46 0.48 20 {3,4} 0.96 0.49 0.46 0.46 2 21 {1,3} 0.97 0.52 0.41 0.47 22 {2,4} 0.97 0.53 0.49 0.52 is not significant, possibly due to the ability of ensemble algorithm to select the most inmative antenna pairs from all of the available antenna pairs. However, when we only have access to data from a single pair of antennas, the AUC decreases to around 0.5, indicating that the detection permance is similar to that of a random guess. This shows that at least four antennas are needed good classification permance, and the permance becomes more reliable as we increase the number to 8 or 16. V. CONCLUSION In this paper, we investigated the classification permance with data sets collected using breast phantoms and from a preliminary clinical trial. We show that classification permance with the ensemble learning algorithm is very good with the breast phantoms even when only two antennas are used, despite our attempts to mimic the practical clinical data acquisition process. This indicates that the variations in data collection, tissue, and breast shape are more complex and varied than we can currently mimic with (our state-of-theart) phantoms. The classification permance achieved in an experiment using breast phantoms may not correspond to that obtained in a clinical setting. We consider that it is important to continue to develop breast phantom construction techniques and to carefully design phantom experiments to incorporate as many of the clinical challenges as possible. The recent work towards 3D-printable phantoms [21] is a promising step in this direction. Our analysis of the clinical trial data suggests that a single antenna pair is insufficient effective classification, and that permance becomes more robust as the number of antennas is increased to sixteen, the maximum available in our system. REFERENCES [1] E. C. Fear, X. Li, S. C. Hagness, and M. A. Stuchly, Confocal microwave imaging breast cancer detection: localization of tumors in three dimensions, IEEE Trans. Biomed. Eng., vol. 49, pp. 812 822, Aug. 2002. [2] H. B. Lim, N. T. T. Nhung, E.-P. Li, and N. D. Thang, Confocal microwave imaging breast cancer detection: Delay-multiply-and-sum image reconstruction algorithm, IEEE Trans. Biomed. Eng., vol. 55, pp. 1697 1704, June 2008. [3] E. J. Bond, X. Li, S. C. Hagness, and B. D. Van Veen, Microwave imaging via space-time beamming early detection of breast cancer, IEEE Trans. Antennas Propagat., vol. 51, pp. 1690 1705, Aug. 2003. [4] M. O Halloran, E. Jones, and M. Glavin, Quasi-multistatic MIST beamming the early detection of breast cancer, IEEE Trans. Biomed. Eng., vol. 57, pp. 830 840, Apr. 2010. [5] P. Meaney, M. Fanning, D. Li, S. P. Poplack, and K. Paulsen, A clinical prototype active microwave imaging of the breast, IEEE Trans. Biomed. Circuits Syst. IEEE Trans. Microw. Theory Tech., vol. 48, pp. 1841 1853, Nov 2000. [6] M. Klemm, J. Leendertz, D. Gibbins, I. Craddock, A. Preece, and R. Benjamin, Microwave radar-based differential breast cancer imaging: Imaging in homogeneous breast phantoms and low contrast scenarios, IEEE Trans. Antennas Propag., vol. 58, pp. 2337 2344, July 2010. [7] M. Klemm, D. Gibbins, J. Leendertz, T. Horseman, A. Preece, R. Benjamin, and I. Craddock, Development and testing of a 60-element UWB conmal array breast cancer imaging, in Proc. European Conf. Antennas and Propag. (EuCAP), Apr. 2011, pp. 3077 3079. 23 {1,4} 0.96 0.52 0.54 0.54

[8] E. Porter, E. Kirshin, A. Santorelli, M. Coates, and M. Popović, Timedomain multistatic radar system microwave breast screening, IEEE Antennas Wireless Propag. Lett., vol. 12, pp. 229 232, 2013. [9] R. C. Conceição, H. Medeiros, M. O Halloran, D. Rodriguez-Herrera, D. Flores-Tapia, and S. Pistorius, SVM-based classification of breast tumour phantoms using a UWB radar prototype system, in Proc. URSI General Assembly and Scientific Symposium (GASS), Beijing, China, Aug. 2014, pp. 1 4. [10] E. Fear, J. Bourqui, C. Curtis, D. Mew, B. Docktor, and C. Romano, Microwave breast imaging with a monostatic radar-based system: A study of application to patients, IEEE Trans. Microw. Theory Tech., vol. 61, pp. 2119 2128, May 2013. [11] S. A. AlShehri, S. Khatun, A. B. Jantan, R. S. A. R. Abdullah, R. Mahmud, and Z. Awang, Experimental breast tumor detection using NN-based UWB imaging, Prog. Electromagn. Res. (PIER), vol. 111, pp. 447 465, 2011. [12] D. Byrne, M. O Halloran, M. Glavin, and E. Jones, Breast cancer detection based on differential ultrawideband microwave radar, Prog. Electromagn. Res. (PIER), vol. 20, pp. 231 242, 2011. [13] Y. Li, A. Santorelli, O. Laest, and M. Coates, Cost-sensitive ensemble classifiers microwave breast cancer detection, in Proc. Intl. Conf. Acoustics, Speech and Signal Proc. (ICASSP), Brisbane, Australia, Apr. 2015. [14] E. Porter, M. Coates, and M. Popovich, An early clinical study of time-domain microwave radar breast health monitoring, IEEE Trans. Biomed. Eng., vol. PP, no. 99, pp. 1 1, 2015, to appear 2015, EPUB ahead of print: http://www.ncbi.nlm.nih.gov/pubmed/26259214. [15] A. Santorelli, O. Laest, E. Porter, and M. Popović, Image classification a time-domain microwave radar system: Experiments with stable modular breast phantoms, in European Conf. Antennas and Propag. (EuCAP), Lisbon, Portugal, Apr. 2015. [16] H. Kanj and M. Popović, A novel ultra-compact broadband antenna microwave breast tumor detection, Prog. Electromagn. Res., vol. 86, pp. 169 198, 2008. [17] A. Santorelli, M. Chudzik, E. Kirshin, E. Porter, A. Lujambio, I. Arnedo, M. Popović, and J. D. Schwartz, Experimental demonstration of pulse shaping time-domain microwave breast imaging, Prog. Electromagn. Res., vol. 133, pp. 309 329, 2013. [18] Y. Li, E. Porter, A. Santorelli, M. Popovic, and M. Coates, Microwave breast cancer detection via cost-sensitive ensemble classifiers: Phantom and patient investigation, submitted publication. [19] Y. Li, E. Porter, and M. Coates, Imaging-based classification algorithms on clinical trial data with injected tumour responses, in Proc. European Conf. Antennas and Propag. (EuCAP), Lisbon, Portugal, Apr. 2015. [20] H.-G. Chew, R. E. Bogner, and C.-C. Lim, Dual ν-support vector machine with error rate and training size biasing, in Proc. Int. Conf. Acoustics, Speech and Signal Proc. (ICASSP), Salt Lake City, UT, May 2001, pp. 1269 1272. [21] M. Burfeindt, T. Colgan, R. Mays, J. Shea, N. Behdad, B. Van Veen, and S. Hagness, Mri-derived 3-d-printed breast phantom microwave breast imaging validation, IEEE Antennas Wireless Propag. Lett., vol. 11, pp. 1610 1613, 2012.