Celerity Fiber Termination Kit

Similar documents
SUPERSEDED. NOT the LATEST REVISION

3M No Polish SC/APC Angle Splice Connector Jacket for 2 x 3 mm FRP and 1.6 to 3.0 mm Cable 8802-T/APC/AS/1.6-3

Termination Procedure

Applications Engineering Notes

Ox-RAC-08 Ribbon Angled Fiber Cleaver User Manual

OxFAC-08 Angled Fiber Cleaver. User Manual. Issue 1.5

MIL-STD B (SH) UPDATE

Harmony Remote Repair

COMPONENT IDENTIFICATION

Applications Engineering Notes

COMPONENT IDENTIFICATION

Reasons for reissue are in Section 6, REVISION SUMMARY.

COMPONENT IDENTIFICATION

Repairing Microsoft Wedge Touch Mouse Battery Cover Retaining Clip

Termination for M29504/4, /5, /6 & /7, Style 2 (Tight)

Issue 2 JUly Fitel USA Corp Page 1 of 16 All Rights Reserved Printed in U.S.A.

UniCam Connector Critical Steps

Field Installed Connectors for TraceTek 7000-HUV Bulk Cable Installation Instructions

SC One Piece Connectors Termination Procedure Series: 728-NNN0-NNN0N

Speed of light E Introduction

Fiber Optic Tool Kit P/N IF-TK4

SC & FC/PC3 Pull-Proof Fiber Optic Connectors

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.

Lab V Multimode Optical Fibers ECE 476

5. Carefully remove the printer from the lower boxed foam support and place it on a solid, level base where it will be used

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

PS4. Ragnarok Flex Modchip Installation Instructions.

ASSEMBLY INSTRUCTIONS

GORE Aerospace Ethernet Cables

Electron Microscopy Sciences

The Useless Machine. DIY Soldering Edition. Instruction Guide v0004

ABM International, Inc.

TOYOTA Tundra 2014 Fender Flare Set

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (ALUMACORE CABLE DESIGNS) FOR BPA

Instructions for Preparing OPTICAL GROUND WIRE IN AN ISOLATOR

Glass cleaning hp scanjet 4500c/5550c scanner

MT RJ Jack Kits [ ],

Aurora,Ohio Fax:

Max Launch Abort System Prod. No *Kevlar is a registered trademark of Dupont

The Useless Machine. Parts Only - Build Guide v0001

Solder is a metallic glue that holds the parts together and forms a connection that allows electrical current to flow.

Custom Pendant- Hardwire Assembly and Installation Instructions

Installation tutorial for Console Customs Xbox 360 Dual Rapid fire Microchip for wired and wireless controllers (all versions)

Be Crafty. Technique Tutorial. How To Apply a Press Lock with Prongs PAGE 1

40 & 50 Foot PS-1 Box Car Assembly Instructions

Service Manual for XLE/XLT Series Laser Engravers

Wiring Devices. Description. Lesson Outcomes. Assumptions. Electrician

FSM-30P SPECIFICATIONS FOR FIBER FUSION SPLICER 1. GENERAL

Circuit Board Assembly Instructions for Babuinobot 1.0

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

Cut-True 16M Manual Paper Cutter

3M Impact Protection Profile Installation System Instructions

Advanced Optical Communications Prof. R. K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay

ILFORD SPORTSVIEW PROJECTOR INSTRUCTION BOOK

CommScope Tool-less IDC Instruction Sheet Connector Block Issue 3, February 2004 Material ID

Repairing your Porsche 928 Central Warning System (CWS) controller

STRIPPING-TOOL-SR-CABLE Stripping Tool for Raychem Self-Regulating Cable Operating Instructions

OpenROV. Guide 3 - Electronics. We will now move to the assembly of the electronics that will control the ROV. Written By: OpenROV

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. DOORS/DRAWERS/LIDS

Volume Control PJ AN

Sabre Series 2 Inspired Design Precision Engineering

Signal Mirror Installation Instructions

Dusty Harp Pickup for lever harps

Vinyl Cutter Instruction Manual

DASH KIT INSTALLATION

Scissor Stool. Written By: Feitan

Welding & Fabrication Tools FT-Flat Electrode Welding

OCT 15 Rev E

PRO 400 M401 MFP M425 CF-280A/X TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS

Written By: Brett Hartt

Octagon Vinyl Gazebo Assembly Instructions

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

Assembly, Installation, Operation and Maintenance Instructions Kit, Base Rail Bracket Part # 31852

Signal Mirror Installation Instructions Dodge Charger, Dodge Magnum, Chrysler 300

Cleaning the cutter blade

COMPOSITES LAB MANUAL

Executive Decision Maker Pro Assembly Guide

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

SYSTIMAX 360 ipatch G2 Fiber Shelf with Faceplate Instructions

Scratch Assay Device for Wound Healing Studies

Repairs. Chapter 10 Repairs 10. 1

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Vinyl Installation Guide and Tips

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

Assembly Instructions: Kit #5

Lexus ES350 Window Clip Replacement

Epson Work Force 1100 CFS System Installation Instructions

GORE Aerospace Ethernet Cables

AAG CloudWatcher Update Humidity sensor (*)

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

PORTROD WALL MOUNTED HEIGHT ROD

Please contact us at BLMAmodels.com for any spare part requests.

Star Trek TOS communicator upgrade kit Install instructions Hyperdyne Labs 2002

SYSTIMAX 360 ipatch Fiber Shelf with Faceplate Instructions

2004-(Z Series) HDILA Lamp Replacement Procedure Quick Step Guide

Basic Users Manual for Tecnai-F20 TEM

Fidelity & Guaranty Building

CORNING. Workstation Multimedia Outlet (WMO) 1. General. Discovering Beyond Imagination. Table of Contents

PanelKeeper GL1500 Kit

Xkitz.com XLO-5CP Control Panel for Five Channel Color Light Organ

Transcription:

Celerity Fiber Termination Kit User Guide Product Overview The Celerity Fiber Termination Kit (CT-FTK) is a professional tool set for splicing and terminating fiber optic cables in the field or at an assembly workstation. The CT-FTK includes all the necessary tools for proper and reliable fiber optic cable terminations. Included items Fiber scissor to cut the fiber jacket, strength members & fibers Thermal stripper to remove the fiber coating Fiber cleaver to precisely cleave the bare fibers Brush for cleaning the thermal stripper and fiber cleaver 10X Magnifier for viewing the fibers in the V-groove glass plate LED UV light to cure the UV glue when applied to the fibers Tweezers to place the bare fibers into the v-groove glass plate Plastic bottle fill with isotropic alcohol for cleaning the bare fiber Tissues for cleaning the bare fibers Required materials (not included) ZapIt Super Glue Isotropic alcohol Recommended UV glue to bond the fiber to glass plate. to clean the bare fibers

Step 1 - Fiber Scissors Cleanly cut the fiber cable with fiber scissors. Using fiber scissors, score and remove the cable jacket 1 (25mm) and then bending the yellow strength member yarn (Kevlar material) back so that the fiber ribbon is fully visible. Cut the yellow strength member yarn at the jacket edge. Step 2 - Thermal Stripper Connect the thermal stripper to its power supply. Do not turn on. Open the magnetic top cover of the thermal stripper and insert 1 of the fiber ribbon in the center channel. Close the magnetic top cover. Press the power button on the thermal stripper. Wait 3 seconds and slowly but firmly pull the fiber ribbon from the stripper. Proper technique result will be six fully exposed 3/4 (18 mm) long glass fibers. Ensure that all six fibers are visible and are not damaged. If any blue color is visible on the fibers, this means the ribbon has not been correctly removed. Re-insert the fiber ribbon repeating the above steps. Confirm the ribbon has been fully removed. In some instances, it may be necessary to repeat Step 1. Precision guideline: The fiber ribbon must be positioned in the thermal stripper ribbon channel perfectly straight to ensure that all 6 fibers are fully exposed and not damaged after stripping. View the fibers carefully before proceeding. If all 6 are not present and the same length, you must repeat step 2 for thermal stripping. Step 3 - Fiber Cleaning before cleaving Using the isotropic alcohol and wiping tissue, clean the fibers, gently wiping AWAY from the cable jacket to the end of the fibers. Check the fibers to be sure there is no damage.

Step 4 - Fiber Cleaver WARNING: NEVER TOUCH THE FIBER CLEAVING BLADE. IT IS SURGICAL-GRADE SHARP AND TOUCHING CAN CAUSE INJURY. Position the fiber cleaver on a flat, stable surface. Open its top cover and fiber holder lid and insert the fiber ribbon carefully into the fiber ribbon alignment channel. The fiber ribbon channel is next to the single fiber channel which is used for cleaving single conductor fiber. The 0.75 bare fibers must fully cross the two black pads. Correct positioning of the fiber to the cleaving blade is accomplished as follows: There is a blue coating along one side of the fiber ribbon. The end of the blue coating is a visual reference for the end of the fiber ribbon where the bare fibers become exposed. Position the end of the blue coating at the inside edge of the black pad to the left of the cleaving blade. Close the fiber holder lid and top cover and push in the cleaving blade assembly. The cleaving blade assembly will lock into place. Open the top cover and fiber holder lid and carefully remove the fiber cable. There should be, to the visual eye, 3/8 ( 9 mm) of 6 bare fibers remaining. Carefully put the cable aside where the exposed and cleaved fibers cannot be damaged. Using the brush and holding the fiber cleaver over a trash receptacle, brush out the fiber channel to remove and safely dispose of fiber splinters. Precision guideline: The 6 stripped and cleaned fibers must be positioned exactly in the fiber cleaver to ensure that the cleaved length of fibers will be 9mm. The 9mm cleaved fiber length is critical to step 6.

Step 5-10X Magnifier and Mechanical Fiber Splice (MFS) bottom section Place the 10X magnifier on a flat, stable surface. The magnifier includes two small LED lights for viewing the tiny fibers to be spliced. Turn on the LEDs using the switch on the side of the magnifier. Place the bottom section of the CT-MFS under the magnifier. Inside the CT-MFS bottom section is a precision glass v-groove plate which serves to properly align the 6 fibers. While viewing under the magnifier, use the tweezers to carefully position the bare fibers into the V-groove glass plate. Precision guideline: The 6 fibers 9mm in length will perfectly fit into the v-groove glass plate and be secured under the top glass surface. View their position using the magnifier and ensure the fiber ends are at the mid-point. Ensure the blue alignment stripe is at the top as you view the fibers. Repeat the same process for the adjoining fibers. The two sets of fibers to be spliced will remain in place as glue is applied. View the splice after glue to ensure the fibers are aligned before proceeding to step 7

Step 6 - Apply Glue and Curing Light Continue working under the 10X magnifier, hold each fiber end with forefront and index fingers, use the other hand to carefully apply 1 drop of glue onto the center of the v-groove where the bare fibers meet. Hold for three (3) seconds and release. The glue will secure the splice for curing. Place the LED curing light on the top of the 10X magnifier and turn on. Hold the fiber end with forefront and index fingers, positioning the splice under the center of the curing light for 30 seconds. The glue will cure. Repeat steps 1-7 for the other end of the Celerity fiber ribbon to be spliced. Step 7 - Mechanical Fiber Splice (MFS) top section Apply glue around edge of MFS. The top section will snap into place with the bottom section to protect the fiber splice.