Wireless Analog Output Modules

Similar documents
Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Wireless 900 MHz Receiver

Wireless Temp/Setpoint & Override Room Transmitter

Wireless HVAC Sensors

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

ELECTRONIC THERMOSTAT: T920

MODEL AT-10 ANALOG TRANSMITTER

Digital Room Sensor Technical Guide

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

E-BUS Digital Room Sensor Technical Guide

Operating Instructions

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

DO NOT USE UNIT POWER

Wireless Analog/Digital Link NEMA 4x Transmitter/DIN-rail Receiver Set

Installation Instructions Space Temperature Transmitter

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Wireless sensor system

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

HARDWARE GUIDE. FlexIO Controller M2000 Series. Specifications and Operational Guide

Lifetime Power Energy Harvesting Development Kit for Wireless Sensors User s Manual - featuring PIC MCU with extreme Low Power (XLP) Technology

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

CX105 Conductivity/Resistivity Transmitter

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Delta Style Room Humidity Units

S ENSORLINK INSTALLATION MANUAL

Installation & Operation Manual

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

OVEN INDUSTRIES, INC. Model 5C7-362

Load Cell Accessories and Services

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

HC900 Remote Termination Panel (RTP) For Analog Inputs

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

IRRIGATION 810-3R RECEIVER GUIDE

- Wiring Brochure Universal Reset Module 423

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

PHASE CUT SIGNAL DRIVERS

Remote Radio Control. WAVE Push button radio control systems

MFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS

HLC-1000 High-limit Humidity Control

HD 48V01T... HD 4977T...

Revision RK-433-RC USER S MANUAL

ECM3 EARTH CONTINUITY RELAY

ALX-SSB 5 Band Filter Assembly Manual 19 November 2018

F2A3X Frequency to Analog Converter Module

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

ELECTRONIC THERMOSTAT: T951

4612 Reference Guide

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Installation Notes. SCR Single Channel

DC Current Transducers

900 ControlEdge Remote Termination Panel (RTP) for:

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Studio Broadcast System

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Proximity Probe Checker PC-100

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

WIRELESS MODBUS GATEWAY WGW410

Contents 1. Installation

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

TECHNICAL PRODUCT DATASHEET

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Instruction Manual. for Media Monkey. 1

DESCRIPTION DIMENSIONS HOW TO ORDER

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

+GF+ SIGNET Temperature Transmitter Instructions

8V General information. 2 Order data 8V

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Remote Site Monitoring

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

The wireless alternative to expensive cabling...

Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

SAPLING WIRELESS SYSTEM

269 Troubleshooting Guide 11/4/98 1

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Wireless Copilot. Safe2Fly - Height Only Version. Page NanoQuip Ltd

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Cat. No. H8861 Model: RCL-S-STAT

Agilent N3300 Series DC Electronic Loads

Hawk 3 Digital Panel Meter / Controller

SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

The first RADIO Communication Module designed for the weighing industry

Blue Point Engineering Inc.

ROAM XL. Commercial Remote Control. ROAM XL Commercial Remote Control Owner s Manual and Programming Instructions

JTM-97a CALIBRATION PROCEDURE

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

KanAtoN 1 / 3 AIS Transponder. Installation Manual

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

DEVAR Inc. 706 Bostwick Ave., Bridgeport CT Tel , Fax

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Transcription:

Overview and Product Identification Wireless Analog s Analog s receive data from a BAPI 418 MHz receiver or 900 MHz receiver through a four-wire RS 485 bus. Up to 127 different Analog s can be connected on the data bus to send multiple variables to the controller. Resistance (ROM): Converts the communication data from a Wireless Receiver into a Resistance for the DDC controller. The unit can be factory calibrated to output a thermistor curve for temperature signals, please consult the product label for the exact type. Voltage (VOM): Converts the communication data from the Wireless Receiver into a linear 0 to 5 volt or 0 to 10 volt signal for the DDC controller. The unit can be factory calibrated for temperature or humidity, please consult the product label for the exact type. Current (COM): This loop powered unit converts the communication data from the Wireless Receiver or a Washdown into a linear 4-20mA signal for the DDC controller. The unit can be factory calibrated for temperature or humidity, please consult the product label for the exact type. Setpoint (SOM): Converts the communication data from a Wireless Receiver into a resistance, or voltage depending on model. The unit can be factory calibrated to output a setpoint signal from a wireless room transmitter, please consult the product label for the exact type. Relay (RYOM or RYOL): Converts the communication data from a Wireless Receiver into a floating solid state switch closure for the DDC controller. The RYOM is a momentary version while the RYOL is a latching version. Note: The Momentary Relay (RYOM) is ONLY used with the Wireless Room Transmitter with Setpoint and Override. Training of the RYOM is covered in the installation/operation sheet for the Wireless Room Transmitter with Setpoint and Override (20357_ins_wireless_temp_xmtr_set_ovr.pdf) which is available on the BAPI website or by contacting a BAPI sales representative. The Latching Relay (RYOL) is ONLY used with the Wireless Universal Input Transmitter. Training of the RYOL is covered in the installation/operation sheet for the Wireless Universal Input Transmitter (24227_ins_wireless_Input_ xmtr.pdf) which is available on the BAPI website or by contacting a BAPI sales representative. Fig. 1: Resistance, or Setpoint with resistance output Fig. 2: Voltage, or Setpoint with voltage output. Fig. 3: Current, Loop Powered Fig. 4: Relay. Analog Training The installation process requires that each transmitter is trained to its associated output modules so that they communicate with each other. Pushing buttons in a defined sequence on the units will bind them together. The training process is easiest on a test bench with the units within arm s reach of each other. Training can be done in the field but requires two people and a set of walkie talkies or cell phones. Be sure to place an identification mark on the transmitter and associated output modules after they have been trained so that they can be matched together at the job site. If more than one variable is transmitted by the transmitter (temperature, humidity and setpoint for instance), each variable requires a separate output module. Perform the training sequence for each output module. Any transmitted variable can be trained to more than one output module. If a Repeater is used in the system, be sure it is powered and within reception range of the transmitter and the 900 MHz Receiver to train the output modules. Continued on next page... 1 of 6

Wireless Analog s Analog Training continued... TEMPERATURE OR HUMIDITY VARIABLE TRAINING 1. To train an output module to a temperature or humidity variable, select the Resistance, Voltage or Current calibrated to the proper temperature or humidity range and connect it to the wireless receiver. Note: Multiple output modules can be trained to the same transmitter. 2. Apply power to the receiver which will supply power to the connected output modules. The power LED on the receiver will light and remain lit. (Current s must have loop power supplied to the module itself before they can be trained.) 3. Remove the cover of the room transmitter and remove the battery tabs or install the batteries, observing polarity as shown in Fig 5. Or open the cover of the BAPI-Box on non-room transmitters and remove the battery tabs or install the batteries as shown in Fig 6. The transmit LED will flash about once every 20 seconds, indicating a transmission. 4. Press and hold down the Service Button on the top of the output module (Fig 7) that you wish to train. Then, press and release the training button (Fig 5 & 6) on the transmitter. When the output module receives the training transmission from the transmitter, the output module s red LED will light steady. Release the Service Button on the output module and the red LED will go out. The transmitter and output module are now trained to each other. During normal operation, the output module s LED will flash about once every 20 seconds indicating data reception from the transmitter trained to it. Note: Combination transmitters send both the temp and humidity data when the Training Button is pressed. However, each is configured at the time of order as a temp, humidity, setpoint or override module and will only recognize the relevant data and will ignore the rest. 5. Mount the transmitter at the desired location, removing the batteries if needed. (The units will remain trained through power failures and battery replacement.) SETPOINT VARIABLE TRAINING 1. To train an output module to a Setpoint variable, select the Setpoint (SOM) calibrated to the proper setpoint range and connect it to the wireless receiver. Note: Multiple output modules can be trained to the same transmitter variable. 2. Apply power to the receiver which will supply power to the connected output modules. The LED on the Receiver will light and remain lit. 3. Remove the cover of the room transmitter and remove the battery tabs or install the batteries, observing polarity as shown in Fig 5. The transmit LED will flash about once every 20 seconds, indicating a transmission. 4. Press and hold down the Service Button on the top of the output module (Fig 7). Then, press and release the OVERRIDE button on the transmitter (Fig 5). (Note: If the unit was not ordered with an override function, then the OVERRIDE button will be shorter and will not extend outside the case but will still be accessible upon removing the cover.) When the output module receives the Training Setpoint info from the transmitter, the output module s red LED will light. Release the Service Button on the output module and the red LED will go out. The transmitter and output module are now trained to each other. During normal operation, the output module s LED will flash about once every 20 seconds indicating data reception. 5. Mount the transmitter at the desired location, removing the batteries if needed. (The units will remain trained through power failures and battery replacement.) Continued on next page... Training Button Battery polarity is important or damage to the unit may occur Transmit LED Battery Connectors Transmitter Module Fig. 6: Non-Room Transmitter battery installation and training. (Duct Temp/ Humidity Transmitter is shown but the process is similar for all nonroom transmitters.) Setpoint Slider Training Button Override Button Transmit LED Fig. 5: Room Transmitter battery installation and training Battery polarity is important or damage to the unit may occur. Output Module Service Button Fig. 7: Output Module 2 of 6

Wireless Analog s Analog Training continued... OVERRIDE FUNCTION TRAINING Training of the Relay s and the Override Function on other Analog s is covered in the installation/operation sheets 20357_ins_wireless_temp_xmtr_set_ovr.pdf and 27986_Wireless_System_Ins.pdf which are available on the BAPI website or by contacting a BAPI sales representative. Note on Training of systems with a Repeater: If a Repeater (BA/RPT49) is used, be sure it is powered and within reception range of the receiver to train the output modules. Also, if a repeater is used, then the receiver must be the 900 MHz version (BA/RCV-900-EZ) rather than the 418 MHz version. Mounting of the 418 MHz Receiver, 900 MHz Receiver and Analog s The 418 MHz Receiver, 900 MHz Receiver and Analog s can be mounted in snap track, DIN Rail or surface mounted. The text and figures refer to the 418 MHz Receiver, but the mounting process is the same for both receivers. SNAPTRACK MOUNTING Push in the blue mounting tabs on the bottom of the receiver and output modules. These units will now fit into the board slots of 2.75 snap track. Insert the receiver at the far left of the snap track, then insert each analog output module and slide it to the left until its connectors are fully mated into the receiver or the next analog output module. You may attach up to 127 analog output modules to a receiver. If your output modules cannot fit in one piece of snap track, then mount another piece of snap track nearby and insert the additional modules. Connect wires from the right side of the first string of modules to the left side of the second string of modules on the second snap track. (See Extending the RS485 Network on pg. 5.) This configuration requires one or more Pluggable Terminal Block Connector Kits (BA/AOM- CONN). DIN RAIL MOUNTING Push out the blue mounting tabs on the bottom of the receiver and output modules. These units will now snap onto DIN Rail. Catch the EZ mount hook on the edge of the DIN rail as shown in Fig 10. Then rotate into place. Fig. 9: Receiver & output modules mounted on DIN Rail. Attach the receiver at the far left of the DIN Rail, then attach each analog output module and slide it to the left until its connectors are fully mated into the receiver or the next analog output module. You may attach up to 127 analog output modules to a receiver. If your output modules cannot fit onto one piece of DIN Rail, then mount another piece nearby and attach your additional modules. Connect wires from the right side of the first string of modules to the left side of the second string of modules on the second DIN Rail. (See Extending the RS485 Network... on pg. 5.) This configuration requires one or more Pluggable Terminal Block Connector Kits (BA/AOM-CONN). SURFACE MOUNTING Push out the blue mounting tabs on the bottom of the receiver and output modules. Attach the receiver to the surface by inserting a screw in each blue tab. Attach Analog s by placing each one against the surface and sliding it to the left until its connectors are fully mated into the receiver or the next analog output module. Attach each module to the surface with two screws, one in each blue tab. You may attach up to 127 analog output modules to a receiver. If your output modules cannot fit in one straight line on the surface, then mount a second string of modules nearby. Connect wires from the right side of the first string of modules to the left side of the second string of modules. (See Extending the RS485 Network... on pg. 5.) This configuration requires one or more Pluggable Terminal Block Connector Kits (BA/AOM-CONN). Fig. 8: Receiver and output modules mounted in snaptrack. Fig. 10: Catch the EZ Mount hook on the edge of the DIN Rail, then rotate into place. Fig. 11: Receiver and output modules surface mounted. 3 of 6

Wireless Analog s 418 MHz Receiver and 900 MHz Receiver with Analog s Termination 418 MHz System Relay 418 MHz Receiver Resistance Voltage Current Requires loop power before it can be trained. RS-485 Bus To Other Analog s System Power Supply 9 to 30VDC or 17 to 31VAC Power for the Power Bus can be supplied to the receiver or to the Analog on the far right of the string of modules, but not to both places. The Power Bus must be connected to the controller - power terminal. The Resistive Thermistor Temp. Signal is Polarity Sensitive to the Controller and Must Have Less than a 5VDC Bias Voltage. Both + and - must be connected to the controller signal input and the negative - connected to the power supply negative - 0 to 5VDC or 0 to 10VDC Analog Signal Current Loop Power Supply 9 to 36VDC 4 to 20mA Current Loop Signal to the Controller Solid State Relay 40 VAC/VDC Max 150 ma Max 1 ua Leakage Max Fig 12: 418 MHz Receiver and System Wiring Termination Notes for 418 MHz and 900 MHz Systems: 1. The wireless receiver and Analog s are interconnected and require module power along the Power Bus terminals. The bus can be powered from either the receiver end on the left or the last output module on the right side. Be sure you have enough DC current or AC VA for all the devices on the bus. 2. The Current (BA/COM) signal is LOOP POWERED and must be externally powered with 9 to 36 VDC separate from the Power Bus. The Loop Power must be connected to the Current before it can be trained. 3. Be sure to follow the polarity (+ or ) symbols listed on each receiver and the output modules to maintain communication and Power Bus integrity. 900 MHz System Relay 900 MHz Receiver Resistance Voltage Current Requires loop power before it can be trained. RS-485 Bus To Other Analog s System Power Supply 9 to 15VDC Power for the Power Bus can be supplied to the receiver or to the Analog on the far right of the string of modules, but not to both places. The Power Bus must be connected to the controller - power terminal. The Resistive Thermistor Temp. Signal is Polarity Sensitive to the Controller and Must Have Less than a 5VDC Bias Voltage. Both + and - must be connected to the controller signal input and the negative - connected to the power supply negative - 0 to 5VDC or 0 to 10VDC Analog Signal Current Loop Power Supply 9 to 36VDC 4 to 20mA Current Loop Signal to the Controller Solid State Relay 40 VAC/VDC Max 150 ma Max 1 ua Leakage Max Fig. 13: 900 MHz Receiver and System Wiring 4 of 6

Wireless Analog s Extending the RS485 Network between the Receiver and the Analog s The Analog s may be mounted up to 4,000 feet away from the 418 MHz or 900 MHz Receiver. The total length of all the shielded, twisted pair (TSP) cables shown in Fig. 14 is 4,000 feet (1,220 meters), and T taps are not allowed. Connect the terminals together as shown in Fig. 14. BAPI s VC350A EZ Voltage Converter and a small transformer can be used to power the group of Analog s. *If the distance from the receiver to the group of Analog s is greater than 100 feet (30 meters), provide a separate power supply for that group of Analog s and install a 120Ω load resistor (1/4 watt) across the + and - communication terminals. Note: This configuration requires one or more Pluggable Terminal Block Kits for the extra wire terminations on the left and right side of the Analog s. Each kit includes 4 connectors. Pluggable Terminal Block Kit (BA/AOM-CONN) RS485 TSP Wiring 120Ω load resistor (1/4 watt) across the + and - communication terminals. See Asterisk (*) above. RS485 TSP Wiring 120Ω*Y 418 or 900 MHz Receiver Analog s Analog s BAPI VC350A EZ Voltage Converter BAPI VC350A EZ Voltage Converter BAPI VC350A EZ Voltage Converter Transformer Transformer Transformer Analog Specifications Fig. 14: Extended RS485 Network between the Receiver and the Analog s All Analog s: Overall Dimensions: 2.5 H x 2 W x 1.25 D, (63.5 x 49 x 31.7mm) Enclosure Material & Rating: ABS Plastic, UL94 V-0 Resistance (ROM): Resolution: ~0.5ºF ROM-102: 35 to 120ºF (1 to 50ºC), 10K-2 Thermistor Curve ROM-103: 32 to 120ºF (0 to 50ºC), 10K-3 Thermistor Curve ROM-10311: 32 to 120ºF (0 to 50ºC), 10K-3 (11K) Therm. Curve ROM-20: 53 to 120ºF (12 to 50ºC), 20K Thermistor Curve Power Consumption: 11.9 ma max. DC,.36 VA max AC Thermistor Bias: Less than 5 VDC max Output Resolution: 10 bit Voltage (VOM): Output Voltage Range: 0 to 5 volts or 0 to 10 Volts Output Current: 1 ma Power Consumption: 11.9 ma max. DC,.36 VA max AC Output Resolution: 10 bit Setpoint (SOM): Setpoint Output Ranges: See data sheet Power Consumption: 11.9 ma max. DC,.36 VA max AC Output Resolution: 10 bit Current (COM): External Loop Power Required: 9 to 36VDC, 9Vmin (no load) (Vsupply - Xmtr Vmin) R-Load Max =.02A Output Max Loop Impedance: 750Ω @ 24VDC Output Current Range: 4 to 20 ma (factory calibrated) Supply Bus Power: Not used by module just feeds through Output Resolution: 12 bit Note: Loop must be powered to train the output module. Relay : Relay Output: 40V (DC or AC peak), 150 ma max. Off state leakage current 1 ua max. On state resistance 15Ω max. 5 second momentary actuation (RYOM only) Latching pending next change (RYOL only) 5 of 6

Wireless Analog s Wireless System Diagnostics Possible Problems: Temperature or Humidity is reading its low limit or high limit, or the LED at the top of the Analog is blinking rapidly: Possible Solutions: - Check for proper wiring and connections from the output modules to the controller. - Check to see if the controller s software is configured properly. - Check for proper power to the receiver, repeater (if used) and output modules. - Retrain the Analog. - Check that the associated transmitter is transmitting (the LED will flash about once every 20 seconds when it transmits). If not, replace the batteries. Check that the associated receiver is receiving the tranmissions (its LED will blink right after the transmitter LED if it receives that transmission.) If it is not receiving the transmissions, move it closer to the transmitter or reposition the antenna for maximum reception. Note: The receiver will receive transmissions from all transmitters that are within range, not just the one you are testing. - Retrain the Analog. Temperature or Humidity reading is coming out the wrong output module - Check for proper wiring and connections from the output modules to the controller. Temperature or Humidity reading is incorrect - Check to see if the controller s software is configured properly. - Check to see if the correct output module is connected to the correct controller. Analog Default Status when Wireless Transmission is Interrupted: If an output module does not receive data from its assigned transmitter for 15 minutes, the red LED on the top of the module will blink rapidly. If this happens, the individual Analog s will react as follows: Resistance s (BA/ROM) calibrated for temperature will output the highest resistance in their output range. Voltage s (BA/VOM) calibrated for temperature will set their output to 0 volts. Current s (BA/COM) calibrated for temperature will set their output to 4 ma. Voltage s (BA/VOM) calibrated for humidity will set their output to their highest voltage (5 or 10 volts). Current s (BA/COM) calibrated for humidity will set their output to 20 ma. Setpoint s (BA/SOM) will hold their last value indefinitely. Relay s (BA/RYOM Units Only) will go to their default state (example: open for a normally open unit). When a transmission is received, the output modules will revert to normal operation in 60 seconds or less. 6 of 6