Thank you for purchasing SmartCell 212 /112 product. Registration and Type Approval Smartcell 212 /112 carries CE Certification, Australia AS/NZS3548

Similar documents
Installation Instructions

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

DTMA-1800-UMTS-12-AISG

Panoramic Power System. PAN-10, PAN-12 User Guide

Hughes 9450 Mobile Satellite Terminal. Installation Guide

Ethernet to 900 MHz RF Modem

Dual Band Home Repeater. User s Guide

Lynx. RoIP Gateway DISPATCH LYNX MOBILE. Optional serial ports provide remote control of radio configuration over the VoIP network.

900 MHz Antenna Sharing Combiner ASC900VG11A

Disclaimers. Important Notice

LINK GPS MGMT DATA. 4 GHz Licensed Backhaul Radio DATA MGMT GPS. Model: AF-4X LINK

850 MHz Antenna Sharing Combiner ASC850VG12A

Installation Instructions

PRX4SERL Four Zone Receiver Decoder

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

Installation & Service Manual

TC ANT MOBILE... Mobile communication antennas and antenna cables. Data sheet _en_00. 1 Description

MPR kHz Reader

Connecting Mains Electrical Power

BRU-100 Physical Installation

Double-Ridged Waveguide Horn Antennas

INSTALLATION AND OPERATING MANUAL

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module

E65C. Communication Industrial and Commercial CU-P40, P41, P42. User Manual

CM /100/1000BASE-T

4-Port Antenna ircu / /65 16/18.5dBi 0 10 /0 10 T V01

GS820-CSA. GS820-CSA class 1 division 2 specifications. Features: Applications: General Description:

Product Documentation

Mounting and Alignment Overview

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Field Hub Installation Guide. P/N Rev. C 05/15

DTMA AISG. Fullband Double Dual Duplex Tower Mounted Amplifier (Masthead Amplifier)

This is by far the most ideal method, but poses some logistical problems:

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

RF Power Amplifier PA15W Owner s Manual SpinCore Technologies, Inc.

REMOTE TRACKING SOLUTION. User Manual Name. CS-P000-TS-1N-Rev.A This document provides the technical specification SOLUTION.

BGU8309 GNSS LNA evaluation board

IMMS-R. IMMS-R Radio Module. Installation Instructions POWER. Controller. Comm.

C-Band Redundant LNA Systems

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

Data Sheet. ACPF-8040 Bandpass Filter for 3GPP Band 40. Features. Description. Functional Block Diagram. Specifications (Typ, 25 C) Applications

Spectrum Sharing 900 MHz Combiner

X-Band Redundant LNA Systems

General Installation Instructions

Full-motion Wall Mount

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

Multi-Channel RS-232 Serial RF Transceiver

GHS 20/20i handset. installation instructions

Kit Kit. GeoSteer GS-900 Radio Kit. GS-900 Radio Kit Installation Instructions Rev A

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

NSPL-500. AIS/VHF antenna splitter. User Manual ENGLISH.

AS-TX86. Please read these instructions carefully before using. This model will hold most Flat Panel TVs. Load capacity: 60kg (132Lbs).

VBRC 4. Radio Communicator. Installer Manual

WISENMESHNET Smart Gateway

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

Analog OptoLock FC300T

W-DMX G4. BlackBox and WhiteBox F-1 BlackBox and WhiteBox R-512 BlackBox and WhiteBox F-2 Micro F-1 Lite Micro R-512 Lite ProBox F-2500.

Hughes 9450 Mobile Satellite Terminal

Applicable for the following PLC UV Head Controller model: PLC R

MBD-8F Automatic Antenna Switch Controller

The coupling torque at 7-16 connectors is Nm! The tightning torque for fi xing the AISG connector must be Nm!

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Technical Manual. Mobile Communication Mini Booster Model: PW-MB or PW-MB10-900

AWS Antenna Sharing Combiner

Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna

Installation Instructions

Spirent Communications TAS 4500 RF Channel Emulator Operations Manual

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Cellular Signal Booster

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

SETTOPSURVEY, S.L. Bofarull 14, Barcelona (Spain) Phone: (+34) Fax: (+34)

Cross-Connect Interface

Solar Sync OWNER'S MANUAL. Solar Sync Sensor Wired and Wireless Solar Sync Sensors. Evapotranspiration Sensor for Compatible Hunter Controllers

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

GS550-CSA. GS550-CSA class 1 division 2 specifications. Features: Applications: General Description:

GainMaker Node SMC Status Monitor Transponder Installation Instructions

SERIES K: PROTECTION AGAINST INTERFERENCE

Data Sheet. ACMD-7612 Miniature UMTS Band I Duplexer. Features. Description. Specifications. Applications. Functional Block Diagram

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

TMR880i technical details

GS550-CSA/ATEX-CE. GS550 for Hazardous Locations. Features: Applications: General Description:

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

Hughes 9450 Mobile Satellite Terminal

PROFIBUS HUB REPEATER

Control Systems Ltd. Drawing Definitions WIRING DIAGRAM FOR SSP REMOTE MONITORING PANEL

Wireless Communications Module Stand-Alone HE200WCM910 and SmartStack HE800WCM900 / HE-WCM900* * HE- denotes plastic case.

UM User manual for the BGU7004 GPS LNA evaluation board. Document information. Keywords LNA, GPS, BGU7004. Abstract

Wing Gate Instructions. Applicable Models: FB1000 / FB3000 FB1200 / FB3200 Version: 1.0 Date: Jun. 2016

GSM Amplifier/Repeater SIGNAL GSM-1205

Hughes 9450 Mobile Satellite Terminal Series. Installation Guide

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

Mounting Instruction. Compact Mini EGC Amplifier and Application

Radio Control Installation and Operating Instructions System 4

Eltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions

Data Sheet. ACMD-7605 Miniature UMTS Band 8 Duplexer. Description. Features. Specifications

Transcription:

Thank you for purchasing SmartCell 212 /112 product. Quasar Communication Systems Ltd. and its distributors assume no responsibility for any damage or loss resulting from the use of its products or this user manual. Quasar Communication Systems Ltd and its distributors assume no responsibility for any loss or claims by third parties, which may arise through the use of its products. Registration and Type Approval Smartcell 212 /112 carries CE Certification, Australia AS/NZS3548 Corporate contacts E-mail: Web address: sales@quasar.biz www.quasar.biz Quasar Communication Systems Ltd. All rights reserved. Quasar, the Quasar Logo, CelluLink and CellBox are registered trademarks of Quasar Communication Systems Ltd. Other product and brand names may be trademarks or registered trademarks of their respective owners. September 2003

1. Introduction 1.1 Overview The SmartCell 212 and 112 gateway enables direct connection of an organization's internal telephony system to commercial cellular networks via an already existing Private Branch Exchange (PBX) system. The SmartCell 212 has a standard ISDN BRI S0 interface on the Line side and connects with 2 channels to any GSM cellular network to create a cellular gateway. The SmartCell 112 is a single channel gateway. SmartCell 212/112 operates at 900MHz/1800MHz. The 212-1900 and 112-1900 models operate at 900MHz/1900MHz. 1.2 Packing List for 212 for 112 Item Description Qty 1 SmartCell 212 unit 1 2 Power Supply 1 3 ISDN S Interface Cable (straight) 1 4 SYNC IN Cable (straight) 1 5 Antenna 2 6 Bag with Screws and Dowel Pins 1 7 Bracket 2 8 Installation Guide 1 Same list apart of one antenna and one bracket provided. 2

SmartCell 212/112 SmartCell 212/112 unit Cables Power Cable ISDN Interface Cable SYNC IN Cable Antenna 2 Bags with Screws & Dowel pins Drill Template 3

2. Safety Precautions Main voltages are present at specific points in this equipment. Some of the parts can also have high operating temperatures. Non-observance of these conditions and safety instructions can result in personal injury or in property damage. The Smartcell 212 system complies with the standard IGC 950. All connected equipment must comply with the applicable safety standards: EN 55022 IEC 1801-2/91 IEC 801-3 IEC 801-4 To avoid injury and prevent equipment damage, observe the following safety precautions: Do not ship equipment unless it is properly packed in its original wrapping and shipping containers. Do not connect the 212 or 112 to any power supply other than the one provided with it. Equipment service and maintenance should be done only by qualified personnel. 4

SmartCell 212/112 3. Product Description 3.1 Technical Specifications* Power supply Supply voltage (secondary) Supply current 12V DC 2 A max. Operating temperature 0 ºC to 40 ºC Standards Full CE ISDN specifications Line interface BRI S/T point reference (indoor only), Type Protocol Connector type Data Port Specifications Interface port/connector type Protocol NT or partial TE. Euro ISDN. RJ-45 RS232 AT command compatible Dial tone 400 Hz ± 1% GSM channel specifications Cellular interface Wavecom GSM module Networks supported Dual band EGSM 900/1800 MHz for 212 or 900/1900 for 212-1900 Full type approval according to GSM phase 2+ Standards specifications. Antenna Antenna gain Antenna gain 2.5 0dB Antenna connector FME or SMA *Specifications are subject to changes without notice 5

3.2 LED Indications Led Description Operation Power Status 1 RCPT.LVL 1 (Reception Level Channel 1) Indicates the status of the power connection. Indicates the SmartCell 212 operational status of channel 1 Indicates the reception level of the GSM channel 1 On the SmartCell 112/212 is powered on. Off the SmartCell 112/212 is powered off. Off the channel is idle and no calls are being handled. On the channel is handling a call. Slow blinking the SmartCell 112/212 is initialising following power up or is being programmed. Fast blinking an error has occurred in the PIN code entry and the outgoing call cannot be completed. The PIN code must be disabled or the default PIN code 1234 must be entered. Green -High reception. Orange -Medium reception. Red-Low reception Off -Very low reception or no reception at all. 6

SmartCell 212/112 Led Description Operation STATUS 2 RCPT.LVL 2 (Reception Level Channel 2) ISDN Ready Sync/ TE Indicates the SmartCell 212 operational status of channel 2. Indicates the reception level of the GSM channel 2 ISDN NT interface indicate the ISDN NT port physical layer status. ISDN TE interface indicates the TE physical layer status or the Sync IN status. Off the channel is idle and no calls are being handled. On the channel is handling a call. Slow blinking the SmartCell 112/212 is initialising following power up or is being programmed. Fast blinking an error has occurred in the PIN code entry and the outgoing call cannot be completed. The PIN code must be disabled or the default PIN code 1234 must be entered. Green -High reception. Orange -Medium reception. Red-Low reception. Off -Very low reception or no reception at all. Off No ISDN NT Layer 1 connection. On ISDN NT layer 1 connection established. Off No ISDN TE Layer 1 connection or no Sync IN. On ISDN TE layer 1 connection established or Sync IN is active. 7

4. SmartCell 212/112 Installation 4.1 Installation Instructions 4.1.1 Locate template on the wall and mark screw location 4.1.2 Bore 3 holes. 8

SmartCell 212/112 4.1.3 Insert 3 dowel pins. 4.1.4 Tighten the two upper screws. Leave a gap of 3mm minimum between the screw head and the wall. 4.1.5 Mount the SmartCell 212/112 on the 2 screws. 9

4.1.6 Tighten the lower screw. 4.1.7 Connect cables. Power cable NT cable SYNC IN cable (only if necessary) 10

SmartCell 212/112 4.1.8 Connect antennas. Antenna x2 Bracket x2 11

4.2 Configuration of the PABX The PABX connected to a SmartCell device must be properly configured in order to operate. The table below describes the configurations. For more detailed information regarding the programming of the PABX, please contact your PABX supplier. Description PBX ISDN Interface Definitions (for normal connection) 1 Define the ISDN interface (TE point reference, point to point with TEI=0.) 2 On LCR (Least Cost Routing) enabled systems, set the CLI programmed to identify cellular prefixes. Comments Required Optional SmartCell 212/112 becomes transparent to internal callers. 3 Use only the original ISDN cable (straight) Required to insure proper operation. 4.3 RJ-45 Connector Pin Layout 12 NT Side TE Side PIN # Function 1 NC (not connected) NC (not connected) 2 NC (not connected) NC (not connected) 3 RX (A) TX (A) 4 TX (A) RX (A) 5 TX (B) RX (B) 6 RX (B) TX (B) 7 NC (not connected) NC (not connected) 8 NC (not connected) NC (not connected) In order to avoid damage, do not use the reserved pins.

SmartCell 212/112 4.4 Cable Connections 4.4.1 Normal Connection In normal connection, the 212/112 is used as the NT side and the PABX as the TE side. The Sync (timing) is delivered from the 212/112 to the PABX over the ISDN cable. The Sync IN/TE port of the 212/112 is not used. Note: If the PABX will not accept the 212/112 as a sync source, use the configuration described in paragraph 4.4.3. 212/112 PABX TE Note: ISDN Ready LED will be ON. 4.4.2 Partial TE mode In this mode, the 212/112 is used as the TE side and the PABX is used as the NT side of the ISDN connection. The Sync (timing) is delivered from the PABX to the 212/112 over the same ISDN cable. To enable this mode, use the QMS S/W to set the 212/112 to partial TE mode (Layer 1 = TE, Layer 2 = TE, Layer 3 = NT). 212/112 PABX NT Note: Sync IN/TE LED will be ON. 13

4.4.3 External Sync mode In this mode, the PABX is used as the TE side and the 212/112 is used as the NT side of the ISDN connection. However, the Sync (timing) is delivered from the PABX to the 212/112 over a second cable (a straight RJ-45 cable, provided with 212/112). This cable connects to any NT port of the PABX, without interrupting the traffic. If more than one 212/112 need to be connected to the PABX - a chain connection can be used such that the first 212/112 provides timing to the second, the second 212/112 to the third and so on. 212/112 Other ISDN telephones may be connected here TE NT TE PABX 14

SmartCell 212/112 4.5 Getting Started 4.5.1 After making all connections and installing the SIM cards, make sure the POWER LED is lit. If it is not, make sure that the power supply is properly connected to the unit and to the AC mains. 4.5.2 During the first few seconds after powering the unit, the STATUS LED will start blinking, indicating unit initialisation. Once the SIM cards have been registered and are operational, the STATUS LEDs will stop blinking. 4.5.3 Verify that the RCPT. LVL LED is green, indicating high reception level. To improve the reception level: Move the antenna to a better location. Place the antenna on a metal plate larger than 20X20cm. Reception Level Indication RCPT. LVL LED Reception Level Reception Level Green High reception -75dBm to 51dBm Orange Medium reception -87dBm to 77dBm Red Low reception -101dBm to 89dBm Off Very low reception or no reception at all less than 103dBm 15