TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

Similar documents
INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Installation Instructions

316R Series Installation Instructions

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Instructions. Installation Type

Installation Instructions. Installation Type

(Wood Door and Frame)

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

Door Closers. General Information

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

5200 Series Door Closer Installation Instructions

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

DC3210. Recommended Closer Size

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door.

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

MUTO COMFORT DORMOTION XL 150/80 L 80

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

1530(F) Mortise Exit Devices Installation Instructions

1500(F) Rim Exit Devices Installation Instructions

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

400 Toll Free: (800) Phone: (718) Fax: (718) RIXSON Overhead Holders. Closer-Holder Packages

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

Assembly Instructions

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

MUTO COMFORT XL 150 L 80

F l a t S c r e e n A R M S I n s t a l l a t i o n

LF Series Assembly Instructions

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

CRL JACKSON 900 SERIES

Installation Instructions for Converting Hinging on Roll-In Refrigerators

Be sure any accessory used will fit with the soft upper doors before installing. Not all accessories will be compatible.

ASSEMBLY AND ADJUSTMENT

Overhead Concealed Closers

Calf-Tel Pen System Assembly Instructions

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

FINISH GROUPS #17 GRP #17 CLEAR

Vigilant Cigar Humidor Vault. Assembly Instructions

#27541 Mobile Laptop. Charging Station. Assembly Instructions

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

Sentinel Series Cigar Humidor End Tables

SERVICE MANUAL. For the ENCORE NON-CATALYTIC WOODBURNING STOVE MODEL 1450

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS INTERIOR WINDOW GUARDS WGI-C1, C2, C3 & C CHEVROLET FULL SIZE WINDOW VANS

#27541 Mobile Laptop Charging Station

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

s tops & holder s Absolute Door Control and Entire Opening Protection

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Door Controls. Table of Contents

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

AndyMark DART 12.

C PART LIST HARDWARE LIST. Kitchen Cart IMPORTANT NOTE

INSTALLATION INSTRUCTIONS CRL JACKSON

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

TITAN2-EDGE Public Access Computer Station Dual Track

How To Measure Your Finished Opening

Kawasaki Teryx 750 Cab Kit* Caution: Before using this product, read this manual and follow all Safety Instructions.

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

Sentinel Series Cigar Humidor End Tables

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

Installation Instructions

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

Installation Instructions. Hold Open Arm Models. Sized (Sizes 2,3,4,5) Weaker BC-H 9303BC-H 9304BC-H 9305BC-H

Swing Door Installation Manual

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Installing Your Electronic Deadbolt

Pedestal Desk IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratches

WG-4 Wall Guard Installation Instructions

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

Senior Swing. Caution

EPPA2-KIT DUAL MONITOR ARM CONVERSION

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

Colonial Classic Bar

Assembly Instructions Nevins Phone Booth

ESA-300 Full Breakout

DuraRac Shelving System

INSTALLATION INSTRUCTIONS

Quick Fit Installation Guide Retractable Screen - Double Door

RANGE DIGITAL HANDSET OPERATION. 1. Panel. 2. Initialization Procedure. 3. Move Up & Down. 4. Set Memory Positions. 5. Move to the Memorized Positions

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

BARLOW TYRIE quality since Ref: x 3m - 12 x 10 Pavilion with Cabrio Folding Roof Step by Step Assembly Instructions

Barnside Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratch

Preference Collection and Treatment Console INSTALLATION GUIDE

Vinyl Sliding Glass Door Assembly Instructions

PART #MSP-DCCST Flat Panel Tilt Mount

Transcription:

Surface applied door closer Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

TABLE OF CONTENTS Closer overall Technical specifications Door template Size selection chart Closer setup Exploded parts list Handing of the door A. Mounting the surface closer Installing the mounting plate Installing the surface closer 4 B. Adjustments Adjusting the closing speeds Adjusting the spring force 6 Adjusting the optional hold open 7 C. Mounting the closer cover Installing the cover 7 Technical specifications Templates Contents NOTE: Refer to the included drawing for pull side door closer back plate mounting templating. Size selection chart Door Width Closer Interior/ Exterior '-0" max. '-6" max. 4'-0" max. TS95 Interior Note. Drawing is not to scale.. Dimensions are in inches/[mm].. Right hand door is shown. 4. Caution: sex nuts are required for attachment of components to unreinforced doors and to wood or plastic faced composite type fire doors, unless an alternative method is identified in the individual door manufacturer's listings. 5. Template is for 4-/ x 4-/ butt hinges & /4" offset pivots 6. Maximum door opening degree is 0. 7. Minimum door width is 6". 8. Hold open range is from 80 to 05. 9. Use closer body style "G" for this installation. 0. Arrows on closer mounting plate point downward. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800-5-848 E-mail: dormaarchitectural@dorma.com 08806 06/4 Reamstown, PA 7567 Fax: 800-74-974 Subject to change without notice

Closer setup Follow included template to properly prepare door and frame for all accessories of the closer installation. Know the swing of the door which is being installed prior to installation. Make sure door efficiently operates prior to installing closer. Verify closer spring size prior to installation. See "Size selection chart" on page. The surface closer is comprised of the following components.. Closer body: "G" body. Main arm. Track assembly 4. Pinion 5. Cover and end caps 6. Closing/sweep speed adjustment 7. Latch speed adjustment 8. Backcheck adjustment 9. Delayed action adjustment 6 7 8 G 9 4 5 5 5 Handing of the door Left hand door (LH) Interior side of door Right hand door (RH) Hinge Hinge Left hand reverse door (LHR) Exterior side of door Right hand reverse door (RHR) DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800-5-848 E-mail: dormaarchitectural@dorma.com 08806 06/4 Reamstown, PA 7567 Fax: 800-74-974 Subject to change without notice

A. Mounting the surface closer Tools recommended Drill Bits Metal: No. 7, No. " & /4-0 Tap Wood: 9/64" & /64"" #0 Phillips screwdriver # Phillips screwdriver /6" flat head screwdriver 5/64", /6" and M5 hex key Installing the mounting plate Reference template 08806 NOTE: For use on an inverted T-mount application (closer on frame, track on door) on the pull side of the door.. Attach the plate to the mounting surface using the four screws [0- machine screws or #0 wood screws] provided with the surface closer. NOTE: Make sure arrows on plate point downward. Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws () provided with the plate itself [M5x45mm flat head screw].. Attach the main arm () to the top pinion with an M6x0 socket head cap screw () using an M5 hex key. Be sure the main arm is parallel to the door during application. Right hand door 4 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800-5-848 E-mail: dormaarchitectural@dorma.com 08806 06/4 Reamstown, PA 7567 Fax: 800-74-974 Subject to change without notice

HINGE Right hand door A B C D F E F D C B A Left hand door HINGE 4 NOTE: Spring tracks are preassembled. 4. Attach the track channel () to the door frame through the end blocks with two flat head Phillips screws () [/4-0 x -/4' flat head screws or #4 - -/4" wood screws]. A. End block B. Spring C. Shock block D. Hold open mechanism E. Track channel F. Hold open slide shoe 5 5. Align the arm () with the hold open slide shoe in the track channel. 5. Attach with one /8-4 x /" shoulder bolt () using an M5 hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800-5-848 E-mail: dormaarchitectural@dorma.com 08806 06/4 Reamstown, PA 7567 Fax: 800-74-974 Subject to change without notice 5

B. Adjustments Set closer spring size prior to making any closing speed adjustments. Do not back valves out beyond closer casting. Maximum opening angle is 0º. Door should close in to 6 seconds from 90º. Do not close valves completely. Adjusting the closing speeds: sweep, latch or backcheck and delayed actions Delayed action [Sweep] [Latch] [Backcheck] Backcheck Sweep 4 [Delayed action] Latch Decrease Increase Sweep & Latch Speed. Adjust the sweep speed () for the area from 70-0 Increase sweep speed: Turn valve counter-clockwise Decrease sweep speed: Turn valve clockwise.. Adjust the latch speed () for the area from 7-0. Increase latch speed: Turn valve counter-clockwise Decrease latch speed: Turn valve clockwise Increase Decrease. Adjust the backcheck () for the area from 65-0. Increase resistance: Turn valve clockwise Decrease resistance: Turn valve counter-clockwise..4 Adjust the delayed action (4) for the area from 0-70. Increase delayed action: Turn valve clockwise Backcheck & Delayed actions Decrease delayed action: Turn valve counter-clockwise Adjusting the spring force TS95 NOTE: Supplied with a size spring setting. Barrier free openings: Take an opening force reading from the pull on the door. If required, adjust the spring force to meet the barrier-free requirement. Decrease force: turn counter-clockwise 5 times (max) Increase force: turn clockwise times (max) Depending on opening conditions, a door adjusted to meet barrier-free forces may not have sufficient power to reliably close and latch the door. TS956 NOTE: Supplied with a size 6 spring setting. Increase force: turn clockwise 6 times (max) Increase Decrease CLOSER TYPE TS95 TS956 TS95 TS956 MAX DOOR WEIGHT (LBS) SPRING SIZE FULL TURNS OF SPRING ADJUSTER 00 0 5 + 50 4 +9 00 5 + 00 5-4 50 6 0 DOOR WIDTH FULL TURNS OF CLOSER INT. EXT. SPRING ADJUSTER SIZE '6" ----- 0 ' '6" + '6" ' +9 4 4' '6" + 5 4' '6" -4 5 4'6" 4' 0 6 6 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800-5-848 E-mail: dormaarchitectural@dorma.com 08806 06/4 Reamstown, PA 7567 Fax: 800-74-974 Subject to change without notice

Adjusting the optional hold open 5/64" set screw (inside the shoulder bolt) NOTE: Refer to section A, step #4 for hold open mechanism location dependent upon hand of door.. To engage the hold open mechanism (), open the door until the hold open slide shoe () connects with the hold open mechanism.. Inside the shoulder bolt () is a 5/64" set screw. To adjust the hold open force, use an 5/64" hex key and turn the set screw: Clockwise = increase force Counter clockwise = decrease force C. Mounting the closer cover Installing the cover 4. Snap both end covers () into place.. Remove the un-needed tab (), and snap the closer body cover () into place.. Attach with a 4-40 Phillips pan head screw (4). DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800-5-848 E-mail: dormaarchitectural@dorma.com 08806 06/4 Reamstown, PA 7567 Fax: 800-74-974 Subject to change without notice 7

DORMA USA, INC. DORMA DRIVE, DRAWER AC REAMSTOWN, PA 7567 TOLL-FREE: 800-5-848 FAX: 800-74-974 E-MAIL: DORMAARCHITECTURAL@DORMA.COM WWW.DORMA-USA.COM 08808 05/04, Subject to change without notice