Comprehensive Ultrasound Research Platform

Similar documents
Ultrasound Brain Imaging System

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

Electronic Buzzer for Blind

Development of the air-coupled ultrasonic vertical reflection method

CHAPTER 1 INTRODUCTION

Ultrasound Brain Imaging System

Current consumption from V CC1 and V EE1 (per channel), MAX4805 V CC1 = -V EE1 = +2V, V CC2 = -V EE2 = +5V. Current consumption from MAX4805A

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

EMBEDDED DOPPLER ULTRASOUND SIGNAL PROCESSING USING FIELD PROGRAMMABLE GATE ARRAYS

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound.

Ultrasonic Multiplexer OPMUX v12.0

AN5258. Extending output performance of ST ultrasound pulsers. Application note. Introduction

Operational Amplifier

Effect of coupling conditions on ultrasonic echo parameters

When you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp

ULTRASCOPE USB, ULTRAWOOD. all the power of a. the palm of your

Fundamentals of Arbitrary. Waveform Generation

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Directivity Controllable Parametric Loudspeaker using Array Control System with High Speed 1-bit Signal Processing

DISTANCE MEASURING EQUIPMENT

CLOUDSDR RFSPACE #CONNECTED SOFTWARE DEFINED RADIO. final design might vary without notice

Chapter 3 Data and Signals

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers

Measuring Distance Using Sound

Faculty of Information Engineering & Technology. The Communications Department. Course: Advanced Communication Lab [COMM 1005] Lab 6.

2. The design and realization of the developed system

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Electronics Design Laboratory Lecture #10. ECEN 2270 Electronics Design Laboratory

HOME ASSIGNMENT. Figure.Q3

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY

MR24-01 FMCW Radar for the Detection of Moving Targets (Persons)

Accurate Harmonics Measurement by Sampler Part 2

EISCAT_3D: Preparation for Production EISCAT3D_PfP

EE3204 D2015 HW Set 3

Scalable Front-End Digital Signal Processing for a Phased Array Radar Demonstrator. International Radar Symposium 2012 Warsaw, 24 May 2012

GPS7500 Noise & Interference Generator

Technology Super Live Audio Technology (SLA)

Digital Fundamentals 8/25/2016. Summary. Summary. Floyd. Chapter 1. Analog Quantities

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

A Model Based Approach for Human Recognition and Reception by Robot

Concepts to be Reviewed

Design & Development of 4-channel Phased Array Control & Amplifier for EMAT based Phased Array UT System for Weld Joints

Fractional Fourier Transform Based Co-Radar Waveform: Experimental Validation

Scope. Here are the times schedule of the pulse-echo technique detect method. Reflect pulse. Emit detect pulse (Ultrasound)

APPLYING SYNTHETIC APERTURE, CODED EXCITATION, AND TISSUE HARMONIC IMAGING TECHNIQUES TO ALLOW ULTRASOUND IMAGING WITH A VIRTUAL SOURCE ROBYN T.

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Pulse Code Modulation (PCM)

FLASH rf gun. beam generated within the (1.3 GHz) RF gun by a laser. filling time: typical 55 μs. flat top time: up to 800 μs

Fast Tuning Synthesizer

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique

A Multichannel Pipeline Analog-to-Digital Converter for an Integrated 3-D Ultrasound Imaging System

Guide to OPKUD and OPBOX Ultrasonic testing units Software Revision 3.0 / 2003

Simulating and Testing of Signal Processing Methods for Frequency Stepped Chirp Radar

As delivered power levels approach 200W, sometimes before then, heatsinking issues become a royal pain. PWM is a way to ease this pain.

Attenuation and velocity of ultrasound in solid state materials (transmission)

Answer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths.

LIMITATIONS IN MAKING AUDIO BANDWIDTH MEASUREMENTS IN THE PRESENCE OF SIGNIFICANT OUT-OF-BAND NOISE

Exercise 2: Distance Measurement

AC LAB ECE-D ecestudy.wordpress.com

! # % & () () +, & ). ) /) : 7 7

Design of Joint Controller Circuit for PA10 Robot Arm

Chapter 4 Digital Transmission 4.1

Pegasus-21. Preliminary Design Review. Senior Design Project Fall 2016

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Challenges of 5G mmwave RF Module. Ren-Jr Chen M300/ICL/ITRI 2018/06/20

Lab 9: Operational amplifiers II (version 1.5)

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

Hardware/Software Co-Simulation of BPSK Modulator and Demodulator using Xilinx System Generator

Signal Characteristics

High Current High Power OPERATIONAL AMPLIFIER

Waveform Encoding - PCM. BY: Dr.AHMED ALKHAYYAT. Chapter Two

430. The Research System for Vibration Analysis in Domestic Installation Pipes

Equipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up

Physical Layer. Networks: Physical Layer 1

Ultrasonic Signal Processing Platform for Nondestructive Evaluation

DS H01 DIGITAL SYNTHESIZER MODULE SYSTEM SOLUTIONS. Features Applications 174 x 131 x 54 mm. Technical Description

Proceedings of Meetings on Acoustics

HA Features. 650ns Precision Sample and Hold Amplifier. Applications. Functional Diagram. Ordering Information. Pinout

Development and Application of 500MSPS Digitizer for High Resolution Ultrasonic Measurements

Laboratory 8 Operational Amplifiers and Analog Computers

UNIT I LINEAR WAVESHAPING

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

Digital Logic ircuits Circuits Fundamentals I Fundamentals I

Outline / Wireless Networks and Applications Lecture 3: Physical Layer Signals, Modulation, Multiplexing. Cartoon View 1 A Wave of Energy

Digital Sounder: HF Diagnostics Module:Ionosonde Dual Channel ( ) Eight Channel ( )

ADVANCES in VLSI technology result in manufacturing

EE 3305 Lab I Revised July 18, 2003

Testing Sensors & Actors Using Digital Oscilloscopes

350MHz, Ultra-Low-Noise Op Amps

12/26/2017. Alberto Ardon M.D.

Significance of a low noise preamplifier and filter stage for under water imaging applications

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 9: Multiple Access, GSM, and IS-95

Final Report (Group 15-22)

Where DSP meets Measurement Science: A Sound Example. By Andrew Hurrell PhD

Lab 9 RF Wireless Communications

Identifying Materials using Radio Frequency

Transcription:

Comprehensive Ultrasound Research Platform Functional Requirements List and Performance Specifications Emma Muir Sam Muir Jacob Sandlund David Smith Advisor: Dr. José Sánchez Date: November 9, 2010

Introduction The goal of this project is to create a prototype ultrasound research platform that will test theoretical developments on methods that use coded pulses to excite ultrasound transducers. These theoretical developments can then be compared to the current methods to conclude that a clearer ultrasound image is obtained. This prototype will test arbitrary waveforms on a multi-pin device, to compare experimental results with theoretical predictions. The preliminary results obtained in this project, by using devices that are already available or at a reasonable cost, will be used to guide the development of a future system (outside of this project s scope) using higher end components. Page 2 of 5

System Block Diagram The steps are as follows: create an arbitrary waveform that will be used to excite an ultrasonic transducer, receive the backscattered echoes, process, and display an image. The excitation waveform must be initially transformed to sigma-delta modulation form to synthesize a digital-to-analog converter. As shown in Figure 1 below, the sigma-delta waveform will be stored in a memory device that is connected to an FPGA. The FPGA will be used to excite the transducer with the arbitrary waveform. Analog circuitry will be required to amplify and filter the digital output from the FPGA pins. After exciting the transducer with a voltage waveform, a pressure wave will propagate through the medium being imaged. The echo received by the transducer will be processed by the analog front end and stored on an embedded device. Finally, the stored data will be sent to a PC, processed, and displayed. Sigma Delta Modulation 128-element Ultrasonic Array Analog Front End FPGA Tx/Rx Switch Embedded Device High Voltage Amplifier PC Low-Pass Filter Figure 1: System Block Diagram Page 3 of 5

Functional Requirements System Requirements The research platform will transmit and receive signals on up to eight channels on the transducer. Excitation waveforms shall be 3 µs or less in duration to maintain a timebandwidth product of 40. Circuitry will be designed to achieve a signal to noise ratio greater than 50 db. Resolution enhancement will create excitation signals capable of enhancing the bandwidth of the transducer to 12.45 MHz (150% of the center frequency of 8.3 MHz). Transmitting FPGA The FPGA shall connect to the PC via Ethernet. The connection must be able to transmit 24 kbits of data to the FPGA in roughly 10 seconds (2.4 kbits/s) or less. The waveform data after being retrieved from the DDR2 shall be parallelized to prepare sending out on the FPGA pins. After parallelization, each pin shall change at a rate of 1 GHz. The waveform data to transmit must be stored in DDR2 memory when it is brought in from PC. Then it must be retrieved when the transmission occurs. The memory speed to support the 8 pin requirement is 62.5 MHz. The FPGA shall store independent sigma-delta encoded excitation waveforms of a maximum of 3072 samples for each of the eight channels. Each channel shall have a configurable delay of up to 5 µs relative to the other channels prior to transmission. The transmitting FPGA shall output a signal to the receiving FPGA when all excitations have been transmitted to start data collection. Signal Conditioning Waveforms from the transmitting FPGA shall be amplified from ±1V (or 0 to 3.3V) to ±10V with a high speed op-amp. Slew rate for this op-amp shall be adequate to avoid distortion of the waveform. A second stage amplifier shall amplify the signals to ±100V to increase energy transmitted by the probe. A low pass filter shall decode the sigma-delta encoded waveforms into a chirp signal. The chirp shall match the desired waveform to within 10% mean squared error. Receiving FPGA To simulate a pulse repetition frequency of 1 KHz, each channel will be recorded for 997 µs after all excitation waveforms have been transmitted for a maximum depth of 76 cm. Received signals shall be recorded using an A/D converter at a rate of 65 MHz and a resolution of 14 bits. Page 4 of 5

The recorded data will be stored in DDR2 memory. The DDR2 memory speed shall be at least 65 MHz. Total data for 8 channels will be approximately 8 Megabytes. Data shall be transmitted to the PC in less than 10 seconds after full data collection using Ethernet (bit rate greater than 5.8 Mbit/s). Data Processing All data processing shall be performed in less than 2 minutes. The image created will display an image for depths between 0.25 cm and 30 cm. Page 5 of 5