ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

Similar documents
ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

References 1 for asynchronous motors 1

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Electronic timer CT-SDD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-SDS.22

Electronic timer CT-TGD.22

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

RENF22R2MMW Zelio Timer Relay - Modular

Protection components

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Zelio Control Measurement Relays

Power supply CP-D 24/1.3

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Power supply CP-E 24/2.5

ATV12H018M3 frekv.pretvarač promj.brzine ATV12 0,18 KW 0,25 ks V 3 faze

Three-phase monitoring relay CM-PFS

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Three-phase monitoring relays

Three-phase monitoring relays CM-PFE and CM-PFE.2

Power supply CP-E 24/20.0

Power supply CP-E 24/0.75

Power supply CP-D 12/2.1

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Protection components

Power supply CP-E 24/2.5

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

02/11/2015

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

02/11/2015

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Power supply CP-D 24/4.2 Primary switch mode power supply

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Three-phase monitoring relay

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

CP-T range Product group picture

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

08/07/2015

Transcription:

Characteristics soft starter for asynchronous motor - ATS01-6 A - 110..480V - 0.75..3 KW Product availability : Stock - Normally stocked in distribution facility Price* : 115.00 USD Main Range of product Altistart 01 Product or component type Product destination Product specific application Device short name Phase Jan 22, 2019 Soft starter Asynchronous motors Simple machine ATS01 1 phase [Us] rated supply voltage 110...480 V - 10...10 % Motor power kw Motor power hp IcL starter rating 3 kw 3 phases 400 V 0.75 kw 3 phases 230 V 1.1 kw 3 phases 230 V 2.2 kw 3 phases 400 V 0.75 kw 1 phase 230 V 1 hp 3 phases 230 V 2 hp 3 phases 460 V 3 hp 3 phases 460 V 0.5 hp 3 phases 210 V 1.5 hp 3 phases 230 V Utilisation category AC-53B EN/IEC 60947-4-2 Current consumption Type of start Power dissipation in W Complementary Assembly style Function available Supply voltage limits 6 A 30 A at nominal load Start with voltage ramp 1 W at full load and at end of starting 31 W in transient state With heat sink Integrated bypass 99...528 V Supply frequency 50...60 Hz - 5...5 % Network frequency Output voltage [Uc] control circuit voltage 47.5...63 Hz <= power supply voltage 110 V AC +/- 10 % 30 ma 24 V AC/DC +/- 10 % 25 ma 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

240 V AC +/- 10 % 65 ma Starting time 1 s 100 5 s 20 Adjustable from 1 to 5 s Starting torque Discrete output current Tightening torque Electrical connection Marking Operating position Height Width Depth Product weight Compatibility code Motor power range AC-3 Motor starter type 30...80 % of starting torque of motor connected directly on the line supply 2 A DC-13 3 A AC-15 7.08 lbf.in (0.8 N.m) Cage type connector rigid 1 2.5 mm² AWG 14 control circuit Cage type connector rigid 1 2.5 mm² AWG 14 power circuit Cage type connector rigid 2 1 mm² AWG 17 control circuit Cage type connector rigid 2 1 mm² AWG 17 power circuit Cage type connector flexible with cable end 1 2.5 mm² AWG 14 control circuit Cage type connector flexible with cable end 1 2.5 mm² AWG 14 power circuit Cage type connector flexible without cable end 1 2.5 mm² AWG 14 control circuit Cage type connector flexible without cable end 1 2.5 mm² AWG 14 power circuit Cage type connector flexible with cable end 2 0.75 mm² AWG 18 control circuit Cage type connector flexible with cable end 2 0.75 mm² AWG 18 power circuit Cage type connector flexible without cable end 2 1 mm² AWG 17 control circuit Cage type connector flexible without cable end 2 1 mm² AWG 17 power circuit CE Vertical +/- 10 degree 3.94 in (100 mm) 0.91 in (23 mm) 3.94 in (100 mm) 0.35 lb(us) (0.16 kg) ATS01N1 0.55...1 kw at 200...240 V 1 phase 2.2...3 kw at 380...440 V 3 phases 0.55...1 kw at 200...240 V 3 phases 1.1...2 kw at 380...440 V 3 phases 1.1...2 kw at 200...240 V 3 phases Soft starter Environment Electromagnetic compatibility Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/Current impulse level 3 IEC 61000-4-5 Conducted and radiated emissions level B CISPR 11 Conducted and radiated emissions level B IEC 60947-4-2 EMC immunity EN 50082-2 Harmonics IEC 1000-3-2 Harmonics IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6 Micro-cuts and voltage fluctuation IEC 61000-4-11 EMC immunity EN 50082-1 Standards EN/IEC 60947-4-2 Product certifications IP degree of protection B44.1-96/ASME A17.5 for starter wired to the motor delta terminal CCC CSA C-Tick GOST UL IP20 Pollution degree 2 EN/IEC 60947-4-2 Vibration resistance 1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6 1 gn 13...150 Hz EN/IEC 60068-2-6 Shock resistance 15 gn 11 ms EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation or dripping water EN/IEC 60068-2-3 Ambient air temperature for operation 14...104 F (-10...40 C) without derating 104...122 F (40...50 C) with current derating of 2 % per C Ambient air temperature for storage -13...158 F (-25...70 C) EN/IEC 60947-4-2 2

Operating altitude <= 3280.84 ft (1000 m) without derating > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m Ordering and shipping details Category 22392 - ATSU01/ATS01 LOW HP SOFT STARTERS Discount Schedule I11 GTIN 00785901416937 Nbr. of units in pkg. 1 Package weight(lbs) 0.40000000000000002 Returnability Y Country of origin DE Offer Sustainability California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. - - - - - - - Substance 2 Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions Mounting on Symetrical (35 mm) Rail or Asymetrical Rail with Adaptor RHZ 66 4

Connections and Schema Example of 3-phase Power Supply Connection (1) A line contactor must be used in the sequence. A1 : Soft starter Q1 : Motor circuit-breaker KM1 : Contactors F1, F2 : Control protection fuses S1, S2 : Pushbuttons 5

Technical Description Function Diagram Us : Uc : LED 1 : LED 2 : Um : Power supply voltage Control supply voltage Green LED Yellow LED Motor voltage 6