Design and Construction a Set of Linear Control Laboratory

Similar documents
Mechatronics. Analog and Digital Electronics: Studio Exercises 1 & 2

EE 370/L Feedback and Control Systems Lab Section Post-Lab Report. EE 370L Feedback and Control Systems Lab

ME451: Control Systems. Course roadmap

LAB 4: OPERATIONAL AMPLIFIER CIRCUITS

Comparative Study of PID and Fuzzy Controllers for Speed Control of DC Motor

Electrical Engineering. Control Systems. Comprehensive Theory with Solved Examples and Practice Questions. Publications

DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY EEE 402 : CONTROL SYSTEMS SESSIONAL

AC : A STUDENT-ORIENTED CONTROL LABORATORY US- ING PROGRAM CC

Switch Mode Power Conversion Prof. L. Umanand Department of Electronics System Engineering Indian Institute of Science, Bangalore

EET 438a Automatic Control Systems Technology Laboratory 1 Analog Sensor Signal Conditioning

Further Control Systems Engineering

Position Control of DC Motor by Compensating Strategies

AN EXPERIMENTAL INVESTIGATION OF THE PERFORMANCE OF A PID CONTROLLED VOLTAGE STABILIZER

LECTURE 2: PD, PID, and Feedback Compensation. ( ) = + We consider various settings for Zc when compensating the system with the following RL:

Design of PID Control System Assisted using LabVIEW in Biomedical Application

Mechatronics. Introduction to Analog and Digital Electronics: Laboratory Exercises 1 & 2

[ á{tå TÄàt. Chapter Four. Time Domain Analysis of control system


While the Riso circuit is both simple to implement and design it has a big disadvantage in precision circuits. The voltage drop from Riso is

Chapter 2. Operational Amplifiers

Figure 1: Unity Feedback System. The transfer function of the PID controller looks like the following:

Experiment 9. PID Controller

Karadeniz Technical University Department of Electrical and Electronics Engineering Trabzon, Turkey

Motor Control. Suppose we wish to use a microprocessor to control a motor - (or to control the load attached to the motor!) Power supply.

Introduction to PID Control

Spacecraft Pitch PID Controller Tunning using Ziegler Nichols Method

Comparative Analysis of P, PI, PD, PID Controller for Mass Spring Damper System using Matlab Simulink.

ANNA UNIVERSITY :: CHENNAI MODEL QUESTION PAPER(V-SEMESTER) B.E. ELECTRONICS AND COMMUNICATION ENGINEERING EC334 - CONTROL SYSTEMS

GE420 Laboratory Assignment 8 Positioning Control of a Motor Using PD, PID, and Hybrid Control

EE 482 : CONTROL SYSTEMS Lab Manual

MEM01: DC-Motor Servomechanism

Figure 1.1: Quanser Driving Simulator

EE 3TP4: Signals and Systems Lab 5: Control of a Servomechanism

EC CONTROL SYSTEMS ENGINEERING

THE differential integrator integrates the difference between

SYLLABUS. osmania university CHAPTER - 1 : CONTROL SYSTEMS CLASSIFICATION

Readings: FC: p : lead compensation. 9/9/2011 Classical Control 1

Comparative Analysis of a PID Controller using Ziegler- Nichols and Auto Turning Method

1. Consider the closed loop system shown in the figure below. Select the appropriate option to implement the system shown in dotted lines using

BANDPASS delta sigma ( ) modulators are used to digitize

Filter Design, Active Filters & Review. EGR 220, Chapter 14.7, December 14, 2017

SKEE 2742 BASIC ELECTRONICS LAB

CDS 101/110: Lecture 8.2 PID Control

EE 3CL4: Introduction to Control Systems Lab 1: Introduction

Introduction to Operational Amplifiers

C H A P T E R 02. Operational Amplifiers

Analytical study and Designing of a I-PD controller (a practical Modified PID controller) for a third order system using MATLAB simulation

ITT Technical Institute. ET4771 Electronic Circuit Design Onsite Course SYLLABUS

MTE 360 Automatic Control Systems University of Waterloo, Department of Mechanical & Mechatronics Engineering

BSNL TTA Question Paper Control Systems Specialization 2007

Başkent University Department of Electrical and Electronics Engineering EEM 311 Electronics II Experiment 8 OPERATIONAL AMPLIFIERS

Rotary Motion Servo Plant: SRV02. Rotary Experiment #02: Position Control. SRV02 Position Control using QuaRC. Student Manual

JNTUWORLD. 6 The unity feedback system whose open loop transfer function is given by G(s)=K/s(s 2 +6s+10) Determine: (i) Angles of asymptotes *****

PID Controller Tuning Optimization with BFO Algorithm in AVR System

Interface Electronic Circuits

EFFICIENT FPGA IMPLEMENTATION OF 2 ND ORDER DIGITAL CONTROLLERS USING MATLAB/SIMULINK

LECTURE FOUR Time Domain Analysis Transient and Steady-State Response Analysis

DEGREE: Biomedical Engineering YEAR: TERM: 1

EE 435. Lecture 16. Compensation Systematic Two-Stage Op Amp Design

SRV02-Series Rotary Experiment # 3. Ball & Beam. Student Handout

DESIGN OF COMPENSATOR FOR DC-DC BUCK CONVERTER

(1) Identify individual entries in a Control Loop Diagram. (2) Sketch Bode Plots by hand (when we could have used a computer

BUCK Converter Control Cookbook

DESIGN AND ANALYSIS OF FEEDBACK CONTROLLERS FOR A DC BUCK-BOOST CONVERTER

5 Lab 5: Position Control Systems - Week 2

ME 5281 Fall Homework 8 Due: Wed. Nov. 4th; start of class.

A Primer on Control Systems

Lecture 10. Lab next week: Agenda: Control design fundamentals. Proportional Control Proportional-Integral Control

Power and Control. Course Description

Lecture 7:Examples using compensators

A Searching Analyses for Best PID Tuning Method for CNC Servo Drive

EE 4314 Lab 3 Handout Speed Control of the DC Motor System Using a PID Controller Fall Lab Information

Circuit Systems with MATLAB and PSpice

Module 08 Controller Designs: Compensators and PIDs

De Anza College Department of Engineering Engr 37-Intorduction to Circuit Analysis

Chapter 8. Natural and Step Responses of RLC Circuits

Introduction... 1 Part I: Getting Started with Circuit Analysis Part II: Applying Analytical Methods for Complex Circuits...

Hands-on Lab. PID Closed-Loop Control

Lecture#1 Handout. Plant has one or more inputs and one or more outputs, which can be represented by a block, as shown below.

Compensation of a position servo

JUNE 2014 Solved Question Paper

EELE 201 Circuits I. Fall 2013 (4 Credits)

Basic Analog Circuits

CIRCUITS, SYSTEMS, AND SIGNALS FOR BIOENGINEERS: A MATLAB-BASED INTRODUCTION

Chapter 2. Operational Amplifiers

Ver. 4/5/2002, 1:11 PM 1

VCSO Mechanical Shock Compensation

Syllabus for ENGR065-01: Circuit Theory

DC SERVO MOTOR CONTROL SYSTEM

A Tool and Methodology for AC-Stability Analysis of Continuous-Time Closed-Loop Systems

Actuators. EECS461, Lecture 5, updated September 16,

AC : A CIRCUITS COURSE FOR MECHATRONICS ENGINEERING

General Purpose Operational Amplifiers

EECE251 Circuit Analysis I Set 5: Operational Amplifiers

Design of Fractional Order Proportionalintegrator-derivative. Loop of Permanent Magnet Synchronous Motor

Closed-Loop Position Control, Proportional Mode

PERSONALIZED EXPERIMENTATION IN CLASSICAL CONTROLS WITH MATLAB REAL TIME WINDOWS TARGET AND PORTABLE AEROPENDULUM KIT

Lecture #2 Operational Amplifiers

Analog front-end electronics

Transcription:

Design and Construction a Set of Linear Control Laboratory Davood Davoodi Khavaran Higher Education Institute student Email: davood.davodi@gmail.com Mahnoosh Shajiee Lecturer of Islamic Azad University, Mashhad branch Email: ma.shajiee@gmail.com Paper Reference Number: 256700 Name of the Presenter: Davood Davoodi Abstract This control set designed and built for the first time by a student. The purpose of design is to better understand the benefits of control systems and comparison theory with practice. View the effect of changing parameters of a system as well as all the effects to impose a compensation controller system that parallel or series can be used in the system. Also being familiar with how the design principles and building a system with equivalent electronic circuits, especially operational amplifier has been studied. Responses of the blocks are designed with the same block in response to content was the same as in Matlab software and in most cases are without any error. One of the obvious advantages of this set is that the noise level which in control systems is very important, in this set is very low. Privileges of created set in comparison with similar sets on the market are more. Key words: controllers, Design and modeling of control systems, Electronic circuits,. Introduction When studying control systems the reader should be able to model dynamic systems and analyze the dynamic characteristics of them. Mathematical model of a dynamical system is a set of equations in different states of the system to accurately or at least a good show [8]. Each system can be shown in different displays depending on individual perspective models. Dynamic behavior of many systems, including electrical, mechanical, thermal, economic, biological, etc can be described by differential equations. The differential equations can be gained by physical laws governing systems for example, Newton's law and Kirchhoff laws for mechanical and electrical systems [7].

2 In order to implementation of control systems, set of linear control laboratory made. This device can be used in Linear Control Systems Lab of electrical engineering, automatic control laboratory, mechanical engineering and chemical engineering process control laboratory. This set implemented as analog blocks and the circuit design is such that the effect of external noise on the system is very low. To simulate various control loops in accordance with the classical linear control headings course is designed and built []. Response of system to various inputs in compare of the response of same system in MATLAB software is very close, that is of high accuracy has been designed. In making this device more features than sets used in other training centers are considered, including the input noise, step, ramp, two-variable and three variable lead controller and lag controller. 2.Data and Material This device includes parts of feeding, generating inputs of step and ramp, addition, subtraction circuits, various blocks with constant coefficients, block with the noise input, controllers such as KP, KDs, KIs apart from the other in two ranges (- 0.) and (-0), two and three-variables structural compensators. Considering the system transfer function using current and voltage laws kirchhoff derived. Whit using the integral and derivative circuits, design began. The set Components are described as below. 2- Integrator Transfer Function This transfer function is a basic linear control block which is most used in modeling mechanical or electrical systems. Also in Mason method and analysis of circuits in the state space plays an essential role. To achieve this transfer function, the operational amplifier was used. Input and output relationship is as follows: Fig. s Transfer function circuit Vo CS Z 3, Vi R3 Z Vo, Vi R3CS S R3CS, R3 0K, C 00F, ()

3 2-2 First Order Transfer Function Implementation of the first order system with different time constants of the form G( S) Ts To achieve this transfer function the operational amplifier was used. Input and output relationship in the model function is as follows: )2( Fig. 2 Transfer function circuit s R2 Vo Z 2 CS, Vi Z R R2 Vo R, Vi R2CS S R2 R2CS,, R R2 0K, R 0K, C 00F, (3) Also other blocks with T 0.0,0.00 were built. 2-3 Proportional Controller K p Proportional controller essentially is an amplifier with adjustable gain that is included in this set. Different range for the intended change of 0. to and other interest is from to 0. If necessary to access more gain, by changing the potentiometer that considered in the design of manufacturing control set can be provided. The controller circuit design was made as following.

4 Fig. 3 proportional amplifier electrical circuit 2-4 Proportional Integral Controller Transfer Function K I s The integral term (when added to the proportional term) accelerates the movement of the process towards set point and eliminates the residual steady-state error that occurs with a proportional only controller. 2-5 Proportional Derivative Controller KDs Fig. 4 proportional integral electrical circuit Derivative control is used to reduce the magnitude of the overshoot produced by the integral component and improve the combined controller-process stability. Fig. 5 proportional derivative electrical circuit 2-6 Lead-Lag Compensator Controllers which are used to improve system parameters such as (steady state error, reducing resonant peak, improve system response by reducing rise time). All these operations can be

5 done by Compensators as well. Lead and lag compensator introduce a pole-zero pair into the open loop transfer function [2]. Different methods for construction of Compensators exist. Op-amp networks, RC electrical network and mechanical systems springs - shock are samples of this compensation. In practice, much compensation op-amp instruments are used. The transfer function of three-variable compensator can be written in the Laplace domain as: (4) Fig. 6 Lea d-lag electrical circuit This circuit if R C R2C 2 acts as lead controller and if RC R2C2 acts as lag controller. Also two variables compensation in this device is included. With this compensation that you get series with the original transfer function can directly impact your change added to the pole and zero applied separately and be seen. 3. Research Methodology The activity of research is to execute the practical system block. It provides advancement of look in these blocks objectively. It constitutes special attitude in students. 4. Results and Analysis Answer all of the hardware blocks were made with the responses obtained in the MATLAB software environment were compared with the same answers that were resulting from this detailed hardware design is done. 5. Conclusions G C S ( S) S 2 (5)

6 With this device any hardware block can be tested. The advantages and disadvantages of each software and hardware procedures in control systems be investigated and compare this two responses. The set that is made in comparison with similar devices on the market are having more features such as low price, noise input, ramp reference and high accuracy. For better outcomes of this set, a digital function generator and digital scope recommended. Another paper in this regard is in progress that includes analyzing the output signal in Matlab environment to achieve characteristics such as frequency domain analysis. References [] Mousavi, M. (2007). principles and laboratory application of linear control systems, Sarafraz publication. [2] A.Hla Myo Tun, S.San Hlaing Oo and C.Myint Myint Yi. (2008). Analysis of Phase Lead Compensator Design for Laser Guided Missile System using MATLAB. World Academy of science, Engeering and Technology 42 [3] Khaki Seddigh, A. (2000). Linear control system, Noor University [4]Taghirad, H. (2002). Introduction to industrial automation and process control. Khaje Nasir University. [5] Rezaee, A and Zahabi M. (2000).Electronic Measurement. Prof Hesabi publication. [6] Doomani, A and Khaki Sedigh, A. (2005). Design of first order stable controller to achieve defined charactrestic. ASCE 05 conference. Cairo Eygept. [7] Dorf, R and Bishop R H (200). Modern Control Systems. 9 th edition-addison Wesley Publishing Company [8] Kuo, B. (995). Automatic Controls Systems, Prentice Hall, Englewood Cliffs, NJ, 7th edition. [9]Jacob, M. (989). Industrial control Electronics. Prentice Hall International