MINI MCR-SL-UI-f(-SP)

Similar documents
MINI MCR-SL-UI-I-LP-NC

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

QUINT-PS-24DC/24DC/10

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

MINI-PS AC/24DC/1.3

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Extract from the online catalog

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Signal conditioner - MACX MCR-UI-UI-NC

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/40

MACX MCR-UI-UI-UP(-SP)(-NC)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS AC/24DC/40

MINI-PS AC/2X15DC/1

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

QUINT-PS/ 1AC/24DC/20

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

PHOENIX CONTACT - 01/2007

Medium Converter FL MC 10BASE-T/FO G850

PHOENIX CONTACT - 09/2009

Power supply CP-D 24/1.3

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Power supply CP-D 24/4.2 Primary switch mode power supply

TRIO-PS-2G/1AC/24DC/5

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

Power supply CP-D 12/2.1

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power supply CP-E 24/0.75

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Power supply CP-E 24/2.5

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Type CP-S, CP-C & CP-A Switch mode

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Switching power supplies CP range, Linear power supplies CP-L range. Content

onlinecomponents.com

High precision measurement system for current and voltage IHC-A/B-RM01/03

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Three-phase monitoring relay CM-PFS

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Overcurrent Protection / 7SJ45

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Liquid level monitoring relay CM-ENS.2x

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays

02/11/2015

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

08/07/2015

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

PHOENIX CONTACT

Installation / Monitoring Technique

SINEAX B 811 Power Pack with additional Functions

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Electronic timer CT-TGD.22

Extract from the online catalog

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-T 24/20.0 Primary switch mode power supply

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Analog signal converters CC-E I/I

PSD-S AE SM DB/1

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

PHOENIX CONTACT

IB IL TEMP 2 RTD (-PAC)

02/11/2015

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

PHOENIX CONTACT - 03/2007

Electronic timer CT-SDD.22

MODEL IAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

Subject to changes 11/2003 Page 1/7

Assembly. Front view. Parametrization interface. Power Bus

Power supply CP-T 24/10.0 Primary switch mode power supply

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

08/07/2015

Electronic timer CT-SDS.22

Thyristor power controller B DI1002 V1.0 Manual/Operating instructions

Transcription:

Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard signals to frequency signals or pulse width modulated (PWM) signals. On the input side, there are the analog signals 0 ma... 20 ma, 4 ma... 20 ma, 0 ma... 10 ma, 2 ma... 10 ma, 0 V... 10 V, 2 V... 10 V, 0 V... 5 V, or 1 V... 5 V. The DIP switches are accessible on the side of the housing and allow the following parameters to be configured: Input signal, Output signal, Output behavior with measuring range overrange or underrange, and Filter type (for smoothing interferences on the input signal). The voltage supply (19.2 V DC... 30 V DC) can be provided via connecting terminal blocks "3"/ "4" or "7"/ "8" of the modules, or together, via the DIN rail connector (see Figure 6 on page 6). Please also observe point "Power Supply" on page 7.. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page: 102477_02_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 1 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com www.phoenixcontact.com/salesnetwork

Ordering Data Products Description Type Order No. Pcs./Pck. Configurable analog frequency transducer with screw terminal block MINI MCR-SL-UI-f 2864082 1 Configurable analog frequency transducer with spring-cage terminal block MINI MCR-SL-UI-f-SP 2810243 1 Accessories Description Type Order No. Pcs./Pck. DIN rail connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 1 Power terminal block with screw connection MINI MCR-SL-PTB 2864134 1 Power terminal block with spring-cage connection MINI MCR-SL-PTB-SP 2864147 1 System power supply (not for Zone 2!) MINI-SYS-PS-100-240AC/24DC/1,5 2866983 1 Technical Data General Data Supply voltage U B 19.2 V DC... 30 V DC Nominal voltage 24 V DC Current consumption < 10 ma Power consumption < 200 mw Transmission error < 0.1% Temperature coefficient (max.) < 0.02%/K Step response 0%... 99% With largest filter Test voltage (input / output / supply) Ambient temperature range Operation Storage Error messages Dimensions (W x H x D) < 15 ms + (1/T) < 1 s + (1/T) 1.5 kv, 50 Hz, 1 min. -20 C... +65 C -40 C... +85 C LED red 6.2 mm x 93.1 mm x 102.5 mm Conductor cross section 0.2 mm 2... 2.5 mm 2 Stripping length Screw connection Spring-cage connection Housing design Electromagnetic compatibility UL approvals (planned) Statement of conformity in accordance with EN 60079-15 GL approval 12 mm 8 mm Polybutylenterephthalate PBT, green c compliant u U PROCESS CONTROL EQUIPMENT FOR HAZARDOUS LOCATIONS LISTED 31ZN Class I Div 2 Groups A, B, C, D T5 A) This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. B) Warning - explosion hazard - substitution of components may impair suitability for Class 1, Division 2. C) Warning - explosion hazard - do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. X II 3 G Ex na II T4 X (planned) Planned 102477_02_en PHOENIX CONTACT 2

Input (see Figure 1, detail 1) I IN U IN Input signal range (configurable) 0 ma... 20 ma, 4 ma... 20 ma, 0 ma... 10 ma, 2 ma... 10 ma 0 V... 10 V, 2 V... 10 V, 0 V... 5 V, 1 V... 5 V Max. input signal 5 V DC 30 V DC Input resistance 50 Ω, approx. 110 kω, approx. Behavior in the event of a fault Alarm signal via red LED Output (see Figure 1, detail 5) f OUT PWM OUT Output signal range (configurable) 0 khz... 10 khz, 0 khz... 5 khz, 0 khz... 2,5 khz, 0 khz... 1 khz, 0 Hz... 500 Hz 0 Hz...250 Hz, 0 Hz...100 Hz, 0 Hz...50 Hz 7.8 khz (10 Bits), 3.9 khz (10 Bits), 1.9 khz (12 Bits), 977 Hz (12 Bits), 488 Hz (14 Bits), 244 Hz (14 Bits), 122 Hz (16 Bits), 61 Hz (16 Bits) Min. load 6 kω 2 kω Max. load current 20 ma Max. switching voltage Overrange/underrange Output protection Conformance With EMC Guideline 89/336/EEC And Low Voltage Directive 73/23/EEC Immunity to Interference According to EN 61000-6-2 1 30 V Configurable Short circuit and polarity protection Discharge of static electricity (ESD) EN 61000-4-2 Criterion B 2 Electromagnetic HF field EN 61000-4-3 Criterion A 3 Fast transients (Burst) EN 61000-4-4 Criterion B 4 Surge voltage capacities (Surge) EN 61000-4-5 Criterion B 4 Conducted disturbance EN 61000-4-6 Criterion A 3 Noise Emission According to EN 61000-6-4 Noise emission of housing EN 55011 5 Class A 6 1 EN 61000 corresponds to IEC 1000 2 Criterion B: Take protective measures against electrostatic discharge. 3 Criterion A: Normal operating behavior within the defined limits. 4 Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. 5 EN 55011 corresponds to CISPR11 6 Class A: Area of application industry. 102477_02_en PHOENIX CONTACT 3

Structure 4 3 2 1 1 Input: Standard signals 2 Transparent cover 3 Diagnostics LED 4 Groove for ZBF 6 Zack marker strip 5 Output: Frequency signals 5 6 c Serial No. XXXXXXXX Out + 5 + 1 OUT IN Out - 6-2 19,2...30VDC 7+ + 3 POWER GND 2 8 - - 4 In U,I GND 1 19,2...30VDC GND 2 on off 1 S2 8 1 S1 8 6 7 8 This output is floating. i.e. voltage must be applied externally. 6 Supply voltage 7 Universal snap-on foot for EN mounting rails 8 DIP switch S1 9 DIP switch S2 10 Connection option for DIN rail connector 0 9 Figure 1 Structure Dimensions 93,1 6,2 102,5 Bild 2 Dimensions (in mm) 102477_02_en PHOENIX CONTACT 4

Installation Screw Connection Spring-Cage Connection Figure 3 MINI MCR-SL-UI-f Figure 4 MINI MCR-SL-UI-f-SP The device may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. VDE, DIN) must be observed. Notes for Ex: The device is category 3 electrical apparatus. Please observe the instructions given here for installation. The device must be installed in a housing with IP54 protection in acc. with EN 60529. The limits for mechanical or thermal loads described for the device must not be exceeded. Only devices designed for operation in the hazardous areas of Zone 2 may be connected. Under no circumstances may repairs be carried out by the user. Only engage or connect conductors in the hazardous area when the device is deenergized! The assignment of the connecting terminal blocks is shown in Figure 5. Block Diagram U Ref IN UI GND 1 1 2 A D C 5 OUT + 6 GND - externally, max. 30 V / 20 ma DC DC UB+ GND 2 DC 3 7 4 8 UB+ GND2 ME 6,2 TBUS-... Figure 5 Block diagram The MINI Analog module can be snapped onto all 35 mm DIN rails corresponding to EN 60715. 102477_02_en PHOENIX CONTACT 5

Using DIN rail connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GN (Order No.: 2869728) Please also pay particular attention to the direction of the MINI Analog module and DIN rail connector when snapping into position: Snap-on foot (Figure 6, detail D 7) below and plug (Figure 6, detail C 11) left! First position the DIN rail connector in the DIN rail to bridge the voltage supply (see Figure 6).. Figure 6 Mounting/removing 102477_02_en PHOENIX CONTACT 6

Power Supply Never connect the supply voltage directly to the DIN rail connector! It is not permitted to draw power from the DIN rail connector or from individual MINI Analog modules! Feeding in power via the MINI Analog module Where the total current consumption of the aligned MINI Analog modules does not exceed 400 ma, the power can be fed in directly at the connecting terminal blocks of a MINI Analog module. We recommend connecting a 400 ma fuse upstream. Feeding in power with a power terminal block Power terminal block MINI MCR-SL-PTB (Order No.: 2864134) or MINI MCR-SL-PTB-SP (Order No.: 2864147), of the same shape, is used to feed in the supply voltage to the DIN rail connector. We recommend connecting a 2 A fuse upstream. Feeding in the power with a system power supply unit System power supply unit MINI-SYS-PS-... (Order No.: 2866983) with 1.5 A output current contacts the DIN rail connector with the supply voltage, allowing several MINI Analog modules to be supplied from the network. Configuration Electrostatic Discharge! The module contains components that can be damaged or destroyed by electrostatic discharge. When handling the module, observe the necessary safety precautions against electrostatic discharge (ESD), in accordance with EN 61340-5-1 and EN 61340-5-2, as well as IEC 61340-5-1 and IEC 61340-5-2. At delivery, the modules are configured as follows: Input 0 V... 10 V Overrange: Freeze at 100% measuring range end value Underrange: Freeze at 100% measuring range start value Output: Frequency output 0 khz... 10 khz Moving Average Filter: 1 value Oversampling: 1 value (All DIP switches in the "off" position). Output Signals Frequency output: Variable frequency/period duration T Figure 7 Frequency output PWM output (Pulse Wide Modulation): Variable pulse to pause ratio/fixed period duration T Figure 8 PWM output 102477_02_en PHOENIX CONTACT 7

DIP Switch S1 Using DIP switch S1 (see Figure 1, detail 8), you can set the input values and the values for Moving Average Filter and Oversampling. Analog 1 2 3 4 IN 0 V... 10 V 1 V... 5 V 0 V... 5 V 2 V... 10 V 0 ma... 20 ma 4 ma... 20 ma 0 ma... 10 ma 2 ma... 10 ma The moving average filter can group values (1, 2, 4, 6) according to the bucket chain principle to form a new measured value. In the bucket chain procedure, the average of a fixed number of measured values is taken, whereby the oldest value is always dropped and the most recent added. 5 6 Moving Average Filter 1 value 2 values 4 values 6 values In order to smooth the measured values, an average can be formed from several measured values (1, 10, 50, 100) (Oversampling). DIP Switch S2 Using DIP switch S2 (see Figure 1, detail 9), you can set the output values and the overrange and underrange values. OUT 1 2 3 4 f / PWM 0 khz... 10 khz 0 khz... 5 khz 0 khz... 2,5 khz 0 khz... 1 khz 0 Hz... 500 Hz 0 Hz... 250 Hz 0 Hz... 100 Hz 0 Hz... 50 Hz 10 Bits, 7.8 Hz 10 Bits, 3.9 Hz 12 Bits, 1.9 Hz 12 Bits, 977 Hz 14 Bits, 488 Hz 14 Bits, 244 Hz 16 Bits, 122 Hz 16 Bits, 61 Hz 5 6 Overrange Freeze at 100% measuring range end value 105% measuring range end value 110% measuring range end value Fault detection OFF 7 8 Oversampling 1 value 10 values 50 values 100 values 7 8 Underrange Freeze at 100% measuring range start value 105% measuring range end value 110% measuring range end value Fault detection OFF PHOENIX CONTACT 02/2006 102477_02_en PHOENIX CONTACT 8