GTEM For emission and immunity testing according to IEC/EN Introduction

Similar documents
GTEM For emission and immunity testing according to IEC/EN Introduction

GTEMCELL GTEM For emissions and immunity testing

GTEM cells. Emissions and immunity testing in a single, shielded environment

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

Double-Ridged Waveguide Horn Antennas

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Electromagnetic Compatibility ( EMC )

COM-POWER OPERATION MANUAL ACS W

Current Probes. User Manual

Schlöder GmbH - EMC Test and Measurement Systems Model #

USER'S MANUAL DMR-6700

Model 3140B BiConiLog Antenna User Manual

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

GTEM Test Cells Test Cells for EMC Radiated & Immunity Testing DC to 20GHz. Test Systems

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

E-Field Uniformity Test Volume In Gtem Cell Based On Labview

FISCHER CUSTOM COMMUNICATIONS, INC.

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

80i-110s AC/DC CURRENT PROBE

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

Appendix A: Specifications

Advanced Test Equipment Rentals ATEC (2832)

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

Model 5400 Series Gigahertz Transverse Electromagnetic (GTEM! ) Cell

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Trees, vegetation, buildings etc.

Localization and Identifying EMC interference Sources of a Microwave Transmission Module

Log Periodic Dipole Array Antenna

BENNING. CM7 Electrical Tester. Service Information

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

HAWK5000 Operators Manual

Amplifier Series BASIC. Installation & Operations Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AMPLIFIER RESEARCH... APPLICATION NOTE: 20

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

MG MW S-Band Magnetron

Electromagnetic Compatibility

Model 1791 VHF Radio User's Manual

The Important Points for Determining the Requirements of EMC Chambers

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

GTEM! Test Cells Enabling Your Success

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

3B SCIENTIFIC PHYSICS

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Broadband Current Probe Series Operation Manual

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

Double-Ridged Waveguide Horn

TT-SI MHz Active Differential Probe

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

D C 01/2019 3

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

DIGIT & POINTER MULTIMETER

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

3B SCIENTIFIC PHYSICS

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Testing for EMC Compliance: Approaches and Techniques October 12, 2006

TT-SI 9001 / TT-SI MHz Active Differential Probes

SOUNDMASTER VF 400 MOS-FET POWER AMPLIFIER OWNERS MANUAL

TT-SI MHz Active Differential Probe

Model MHz Arbitrary Waveform / Function Generator

High precision measurement system for current and voltage IHC-A/B-RM01/03

Current Probe Fixture Instruction Manual

Appearance of device and accessories may vary.

Semi Anechoic Chamber (SAC)

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

TOA 500 SERIES MIXER POWER AMPLIFIER

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

TEST REPORT... 1 CONTENT...

INVESTIGATION OF THE LONGITUDINAL FIELD COMPONENT INSIDE THE GTEM 1750

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

INSTALLATION AND OPERATING MANUAL

CBA 400M MHZ to 400 MHZ

AMM-1022 Digital Multimeter USER`S MANUAL

RADIATED IMMUNITY TEST SYSTEM 6 GHz

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

TZ-RD-1740 Rotary Dipole Instruction Manual

Models 1421 and 1422 User s Manual. Broadband Amplifiers

Broadband Current Probe Series Operation Manual

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Digital Clamp Meter Model: &

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Model AS08010, M1 AR System 10kHz 8GHz

Transcription:

page 1 of 9 GTEM-1000 For emission and immunity testing according to IEC/EN 61000-4-20 Introduction The GTEMCELL GTEM-1000 is a TEM waveguide with the upper frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides. Compared to other measuring methods like EMC test in anechoic chambers or OATS (Open Area Test Sites), GTEM-cells offer some significant advantages for the testing of small and medium sized EUT s (Equipment Under Test) up to a frequency range of 20 GHz. Quick turnarounds of the EUT as well as numerous testing variations are easy and fast to handle. Switching from emission to immunity testing requires only simple adjustments from receiver input to amplifier output. You are irrespective of long waiting times associated with off-site test labs or weather and ambient delays that can occur at OATS facilities. Whether you are at the design qualification, pre-compliance, compliance, or production sampling stage, the GTEM is the right choice for you! Key Features Ruggedized fully hot galvanized and INOX steel construction

page 2 of 9 Unique compact design with new Apex impedance matching transition Optimized for EMI and EMC Strong fields achieved with low input power Broadband line and termination up to 20GHz Excellent quality at low cost Technical panel Line filters box

page 3 of 9 Technical specifications Frequency range Septum height Max EUT size (LxWxH) Defined test volume Typical VSWR (average value) Typical VSWR at critical frequency (average value) Max. input power, W continuous/pulsed Input connector Nominal impedance For emissions: 9KHz - 3 Ghz, For immunity applications: 80MHz 6GHz * DC-20GHz optional 1000 mm 75x75x50 cm 35,5x33,5x33,5 cm 1:1.2 (for immunity test range) < 1:1.6 (for immunity test range) 1,5 kw/2.5 kw 7/16 or N UG-21 50 Ohm Mechanical Construction Materials Outer dimensions (LxWxH) Door (WxH) Window in the door (WxH) Weight Wheeled undercarriage (with brakes) Hot galvanized steel, Door Inox steel, Carbon loaded poliurethan pyramidal foam 65cm Height 500 x 271 x 188cm + 25cm Trolley Standard: 80 x 80cm * * Optional: circular Diam.200mm. Approx. 650kg Electrical Mains connectors Main switch Input socket plug Output socket EUT tape Additional EUT sockets Ground connection EMI AC Line filter (mono phase + ground) EMI AC/DC secondary filter Channel for fiber optic leads RF feed-thru connector RF feed-thru SMA connectors Technical panel pre-drilled for options Fix/CEE magneto-thermal 16A mono phase 16 AC IEC Type ( mono phase + ground) 16 AC SHUCO type (mono phase + ground) * Optional M6 bolt,(it is required be always connected) 16A 250V n.2 terminals +ground 10A 250V AC/DC N.2 terminals 3 couples (18GHz Cut-off frequency) N.1 N-N female N.2 SMA-SMA female supplied Options Midia filter unit Video camera system Indoor lighting Manipolator X,Y,Z *Optional: N.1 RJ45, N.1 DB9-RS232, N.2 USB-2, N.1 DC filter. *Optional 20W LED *Optional: Motorized USB, Manual, Remote controlled

page 4 of 9 Installation manual and general safety instructions The GTEM (Giga Hertz Transverse Electromagnetic) cell is a precision electromagnetic compatibility (EMC) test instrument primarily intended for use as radiated immunity and radiated emission test facility without environmental electromagnetic interference. The cell is electrically similar to a coaxial cable with one side open (the apex) and other side closed on the impedance of the generator or receiver connected. In this case with a multimeter appears a 50 Ohm resistance. Measurement setup The setup for emission measurements in a GTEM cell is shown in Fig. 1. The EUT is placed inside the GTEM and its radiation is measured with a receiver. The receiver can be software controlled and some software that includes the GTEM to OATS correlation is commercially available. Fig. 1

page 5 of 9 Testing Volume Fig.2 - Maximum EUT size and maximum size of the usable test volume in a GTEM cell, longitudinal section Fig.3 Maximum EUT size and maximum size of the usable test volume in a GTEM cell, cross section

page 6 of 9 Calculating Power Required - Theory Basically, we have to consider the volts per meter, the height of the septum, the allowance of voltage peaks caused by amplitude modulation and the flatness with frequency. For flatness, we generally allow 3 db, this only takes effect after the first resonance point. The example above shows 10 V/m with a GTEM 1000 Septum height = 1,0m Flatness = 3 db = 2 Power Required = [ (E x h)2 /R] x Flatness x Modulation Allowance E [V/m] = required field strength: (i.e. 10V/m) h [m] = septum height R = GTEM input impedance (50 Ohm) Power Required = [(10 x 1,0) 2/ 50] x 2 x 3,24 = 9,88 Watt GTEM-1000 Power requirement Field Strenght E Flatness Modulation allowance Required power modulated Required power CW V/m 3dB = 2 80% AM, 1kHz Watts Watts 3 2 3,24 1,17 0,36 10 2 3,24 12,96 4 20 2 3,24 51,84 16 Factory control s - Performance test: A verification test was performed on site of the installation with a Network analyzer VNA Tiny. REFLECTION COEFFICIENT: S11 magnitude of GTEM-1000 in the range 80-3000MHz

page 7 of 9 REFLECTION COEFFICIENT: S11 magnitude of GTEM-1000 in the range 80-3000MHz

page 8 of 9 Guaranteed reflection coefficient S11 GTEM-1000 Reflection coefficient S11 <-14 db in 80 MHz -4GHz S11 accuracy magnitude/phase ± 2 db / 1 degrees Electronic Component list (Filter box): 16A, 250V IEC input power line panel male socket (external) 16A, 250V SCHUCO output power line female tape (internal) FILTER CONCEPTS 250Vac 2x20A, 50/60 Hz L=2x60uH+2x8.3mH, Cx=2x2,2uF, Cy=2x0.0068uF, R=1.2MOhm N.2 Feed-thru filter Arcotronics 16A 250Vac N.1 Magnet-thermally switch GEWISS Mod. C-16, 16Amp.* Mains switch WARNINGS! READ BEFORE USING HANDLE CAREFULLY The GTEM cell is professional test equipment intended for EMC emissions and immunity test purposes operated by trained personnel. Some care are necessary: - Don t push or pull the apex to move the cell, move only from the frame trolley. Before move the cell, loosen the unlock the wheel brake than when you finish lock again. Open or close the door softly. Handle carefully. Insert always straight the N and SMA connectors, don t tight too much, it is not necessary! One N type corner adaptor connector is supplied to protect the apex, please don t remove it. If it brokes replace with one of the same quality RADIO FREQUENCY RADIATION Personnel should not be exposed to the microwave energy which may radiate from this device. All inputs or output RF connection gaskets must be leak proof. Never look inside or leave doors open when this device is energized! ELECTROMAGNETIC FIELD Strong RF levels may cause de-magnetization and interference to others services. Operate always with the door closed and keep sensitive devices far from the door. SHOCK HAZARD Accidental short circuit or leakage current may occurs: Supply the unit through magneto-thermal differential switches lines. Keep always the GTEM cell grounded also with power supply disconnected. During normal tests operation connect energy only with the door closed. ELECTROSTASTIC DISCHARGE To avoid ESD keep always the GTEM cell grounded fitted with a permanent earth 16 mmq. wire conductor. DANGER Risk of injury at hands and head or cuts around the metallic surfaces of the chamber may occur. Leave around the cell a free area from obstacles.

page 9 of 9 MAINTENANCE Verify periodically: the status of the door gasket, I/O connectors integrity. Oil the wheels of the trolley and the door hinges. Clean inside the chamber excess of dust with a vacuum cleaner. Protect metallic surfaces against corrosion, clean it with a soft cloth wet of Vaseline, Silicon or Paraffin oils. Avoid cleaning with water based products or chlorine solutions! Maintenance - When you are not operating live partially open the door avoiding stressing too much the gasket (they could take memory form reducing the shielding properties). - Avoid touching the anechoic pyramids with the fingers or objects as they can be damaged easily. - Take care at the N input connector, do not remove the protection angle adaptor, if damaged occurs replace urgently the adaptor with one similar: straight or angular just to save the input connector. - For cleaning purposes remove before any power supply source from the GTEM cell, then use only a wet of water added with soft detergent tissue for the window, avoid aggressive products: they can damage the meta-acrylate glass. - Periodically remove dust inside the cell with a vacuum cleaner Troubleshooting No power supply in the plugs : fuse interrupted in the socket (replace with the same value 16A to protect the line filter) or magneto-thermall switch off. No field with RF power applied: pin of the corner coaxial adaptor broken: replace urgently with a similar one Additional info Power supply: when necessary connect the AC 230V or 400V power cord, verify the presence of differential switch and magneto-thermal switches. Load: Do not apply over load to the line filter: remember the max. load is 16A for the plug and 10Amps for the banana jacks. Ground: A ground connection is necessary for your safety: please connect a 16mm 2 wire at the building earth system permanently by the screw placed down the filter box. Verify periodically the status of the connection. Keep in mind that the metallic structure in case of leackage is conductive! Door: During immunity test the door (if necessary) could remain also opened; the field losses are negligible and the result of the test do not suffer a lot. Additional holes: You can make feed-throught passages only on the technical panel (remove it if necessary) RF Max Power input: No care are necessary, the terminations are over dimensioned, the limit is 1200W and Peack pulse power up to 2,5KW (2uSec) with operating temperature up to 100 C.