Preamplifier Options for Reducing Cable-Braid Loop Error

Similar documents
The 2-Port Shunt-Through Measurement and the Inherent Ground Loop

How the Braid Impedance of Instrumentation Cables Impact PI and SI Measurements

Opamp stability using non-invasive methods

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

PDN Probes. P2100A/P2101A Data Sheet. 1-Port and 2-Port 50 ohm Passive Probes

RF Characterization Report

Do not measure PDN noise across capacitors!

<Insert Picture Here> DC and AC Bias Dependence of Capacitors

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

DesignCon Effect of Power Plane Inductance on Power Delivery Networks. Shirin Farrahi, Cadence Design Systems

Battery Impedance Measurement

How to Design Good PDN Filters

Evaluating DC-DC Converters and PDN with the E5061B LF-RF Network Analyzer. Application Note

Keysight E5061B ENA Vector Network Analyzer CONFIGURATION GUIDE

Demo Circuit DC550A Quick Start Guide.

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Measuring Power Line Impedance

Keysight Technologies Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer. Application Note

NATIONAL UNIVERSITY of SINGAPORE

DC Biased Impedance Measurement

Aries Kapton CSP socket

How to Design a PDN for Worst Case?

Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz

Physical Test Setup for Impulse Noise Testing

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

PARAMETER CONDITIONS TYPICAL PERFORMANCE Operating Supply Voltage 3.1V to 3.5V Supply Current V CC = 3.3V, LO applied 152mA

Vector Network Analyzers (VERY) Basics. Tom Powers USPAS SRF Testing Course 19 Jan. 2014

Power Supply Rejection Ratio Measurement

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Vector Network Analyzer Application note

Configuration of PNA-X, NVNA and X parameters

1000BASE-T1 EMC Test Specification for Common Mode Chokes

S3602A/B Vector Network Analyzer Datasheet

Differential Signal and Common Mode Signal in Time Domain

TRANSDUCER INTERFACE APPLICATIONS

EMC Near-field Probes + Wideband Amplifier


Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

Agilent AN Applying Error Correction to Network Analyzer Measurements

The Active Bridge 11/20/09

Designing Microphone Preamplifiers. Steve Green 24th AES UK Conference June 2011

How the Braid Impedance of Instrumentation Cables Impact PI and SI Measurements

Characterizing Non-Standard Impedance Channels with 50 Ohm Instruments

Frequency-Domain Characterization of Power Distribution Networks

Track and Hold Evaluation Module. Figure 1 EVRTH90 Module. Track and Hold Evaluation Module with a RTH090-HQ

Wafer-Level Calibration & Verification up to 750 GHz. Choon Beng Sia, Ph.D. Mobile:

Low Distortion Mixer AD831

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

A Termination Insensitive Amplifier for Bidirectional Transceivers

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 678A 40MHZ TO 900MHZ DIRECT CONVERSION QUADRATURE DEMODULATOR

A Low-Loss VHF/UHF Diplexer

Signal Injectors. Documentation. Version 1.00, October, Picotest Corp. All Rights Reserved.

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

M5090. Extended Specifications EXTEND YOUR REACH TM

Low Distortion Mixer AD831

DC Biased Impedance Measurements MOSFET

Features and Technical Specifications

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues

SWR/Return Loss Measurements Using System IIA

Cobalt Series 20 GHz EXTEND YOUR REACH TM

Validation & Analysis of Complex Serial Bus Link Models

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Measurement and Comparative S21 Performance of Raw and Mounted Decoupling Capacitors

Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

Making Invasive and Non-Invasive Stability Measurements

1-Port USB VNA - R60 Extended Specifications

Harmonic Comb Injector

Bias-T Design Considerations for the LWA Brian Hicks and Bill Erickson May 21, 2008

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

Compact VNA - TR1300/1

AV3672 Series Vector Network Analyzer

CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS

WI-FI/BLUETOOTH & PCB TUNING AND ANTENNA TESTING

Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1455A 5MHZ TO 1600MHZ HIGH LINEARITY DIRECT QUADRATURE MODULATOR LTC5598 DESCRIPTION

Measure Low Value Impedance Current Shunt Impedance

Vector Network Analysis

Model 176 and 178 DC Amplifiers

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Model 25A Manual. Introduction:

Micro Coaxial Connector. Ultrasmall Series with mating height 1.00 mm

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

S3602C Vector Network Analyzer Datasheet

A Noise-Temperature Measurement System Using a Cryogenic Attenuator

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

Description RF Explorer RFEAH-25 1 is a 25mm diameter, high performance near field H-Loop antenna.

5 ESSENTIAL HINTS TO IMPROVE Millimeter-wave Network Analysis

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

Microwave Metrology -ECE 684 Spring Lab Exercise I&Q.v3: I&Q Time and Frequency Domain Measurements

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

AN-671 APPLICATION NOTE One Technology Way P.O. Box 9106 Norwood, MA Tel: 781/ Fax: 781/

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

Audio Amplifier Frequency Response

RBW FILTER SWITCH BOARD FOR THE MSA Sam Wetterlin 5/30/10 (modified 9/9/10)

An electronic unit that behaves like a voltagecontrolled

1.3 Watt Audio Power Amplifier

Yana Dongles Tom Berger K1TRB (c)2016 v171227

Transcription:

QuietPower columns, December 2018 Preamplifier Options for Reducing Cable-Braid Loop Error Istvan Novak, Samtec It has been known for quite some time [1] that when we measure low impedance with the Two-port Shunt-through configuration, we potentially create an error due to the resistance of cable braids. This error, illustrated in Figure 1 (reproduced from [2]), can be reduced or eliminated in a number of ways, among others by using measuring instruments with floating or semi-floating [3] connector references or with appropriate preamplifiers. Figure 1.: Illustration of the cable braid error when measuring a 2.5 mohm resistor with semi-floating connections. Red trace: all connectors grounded. Blue trace: connector shells are semi-floating. But what is the true nature of this error and what features of a preamplifier can help us to eliminate it? This is what we look at in this article. I. Introduction Figure 2 shows the equivalent circuit of a two-port shunt-through measurement connection. You can easily see what creates the error shown in Figure 1 if you follow the current in the simplified equivalent circuit. The source is practically shorted, driving its shunt current through the Port 1 cable. This current goes through the DUT and has to return to the VNA on the cable braids, which will lift the potential of the DUT_return point. If you then follow the path highlighted by the red line, you can also see a direct connection from the DUT_return point to the Port 2 input.

Figure 2.: Two-port Shunt-through impedance measurement scheme with a two-port vector network analyzer. Full and simplified equivalent circuits on the left and right, respectively. Our problem is that while we want to measure the differential voltage across the unknown Zdut impedance, Port2 receives this voltage riding on a common-mode error voltage on the DUT_return point and our typical VNA inputs have no common-mode rejection. This tells us that to reduce or eliminate this error, we have to either reduce the common-mode error voltage by limiting the current flowing in the cable braids, or we have to sense the voltage across Zdut in a differential fashion, or some combination of these two. All methods that address this problem, are various implementations of these options. Using preamplifiers is one possibility, but the actual characteristics of the preamplifier still matter. Some preamplifiers work well on the Port 1 cable, some others work well on the Port 2 cable, yet some others will work equally well on both cables. Figure 3 shows these two options: preamplifier in series of the Port 1 or the Port 2 cable. Figure 3: Preamplifier connection options: placing it on the Port 1 cable (on the left) or on the Port 2 cable (on the right). 2

We could certainly add preamplifiers in series to both cables, but it would be an overkill, and as we will see below, if we are not careful how we choose the preamplifier features, two incorrectly selected preamplifiers actually may help less than one preamplifier with the correct features. In Figure 3 the preamplifier is represented with a very simplified equivalent circuit: for now, we ignore its power supply requirements and don t consider any frequency dependency either. There are five elements in the equivalent circuit: three resistors representing the common-mode and differential-mode input resistance and a voltage source and a series resistor representing the output. For the purposes of this discussion, the voltage gain or the output resistance do not matter much. A unity-gain amplifier with 50-ohm output impedance is a good start, but different values could equally work. The two parameters that really matter are the input impedance and common-mode rejection of the preamplifier. As we explain below, whether we want to use the preamplifier on the Port 1 or Port 2 cable, different requirements will apply. When the preamplifier is on the Port 1 cable, we can eliminate the cable-braid error with high input impedance. A high input impedance will significantly reduce the return current on the cable braid, and even if there is no common-mode rejection in the amplifier, the error is eliminated. On the other hand, when we chose to put the preamplifier on the Port 2 cable, input impedance does not matter, since the amplifier input is driven by the low-impedance DUT. However, in this case the common-mode rejection becomes important: with the full shunt current of the source returning on the cable braid, we can suppress the error only if the preamplifier ignores the common-mode voltage on the DUT_return node and responds only to the differential voltage across the DUT. If we want a preamplifier to be effective on either the Port 1 or Port 2 cable, we need an amplifier with high input impedance AND high common-mode rejection. Dependent on the application, there is a long list of further practical considerations. The cable braid error usually diminishes above a few hundred kilohertz, so luckily the common-mode rejection performance of the amplifier does not need to be very wide band. However, the common-mode input and output voltage ranges may become the limitation when we measure DUTs with DC bias voltage coming from the VNA or when the DUT itself is active, having its own DC source voltage: this can happen if we measure a power converter. Also, when we have the preamplifier on the Port 1 cable, a high common-mode rejection (something that in this case we don t need to reduce the cable braid error) would eliminate the possibility of measuring a capacitor with DC bias voltage coming from the VNA port. The output in this case may be stressed when we measure a live DC source: battery or voltage regulator. When we put the preamplifier on the Port 2 cable, the good common-mode rejection and high common-mode input voltage range become important so that we can measure active DUTs and components with DC bias. The power supply for the preamplifier is equally important. If we want the ultimate isolation, battery powered preamplifiers are the best. 3

II. Build your own preamplifier There are professional preamplifiers on the market [4], which do a great job reducing the cable braid error. If you want to experiment with your own circuit, the rest of this article will help you. For the examples shown here, we use the robust AD815 dual operational amplifier. It has a guaranteed output current of 0.4A, 120 MHz closed-loop bandwidth and a 5 ua worst-case input bias current. With this operational amplifier we can build preamplifiers with very good performance up to at least 10 MHz. II.1. Preamplifier with high input impedance A preamplifier with a single package of AD815 is shown in Figure 4. The amplifier has 200 kohm differential input resistance, but practically no common-mode rejection. It has a forward gain of -6dB between 50-ohm terminations and it can handle up to +- 2V DC bias on its input. Note that the input common-mode voltage range will increase if you use higher supply voltage. The schematics is shown in Figure 4. The preamplifier was built up on perforated prototype board with no copper on either side. The power source was two sets of AAA batteries supplying +-6V nominal voltage. This preamplifier is a good choice for Port 1 applications so that the braid current can be blocked by its high input impedance. Because it has no common-mode rejection, this amplifier is not a good choice for Port 2 cables. Figure 4.: Schematics of preamplifier with high input impedance and no common-mode rejection. Figure 5.: Construction of the preamplifier with high input impedance and no commonmode rejection. 4

The construction is shown in Figure 5. There are right-angle SMA connectors on the input and output. For sake of convenience, there are male and female connectors paralleled up on both sides, this will allow us to connect cables with SMA connectors without adaptors. The connectors, operational amplifier, bulk capacitors and the power connector are on the top side, all other components are on the bottom side of the board. To protect the small components on the back from mechanical damage and to provide some insulation, the back side is covered with epoxy resin. The preamplifier was measured in several different configurations. A typical test result is shown in Figure 6, taken with a Keysight E5061B VNA in the 1 khz 100 MHz frequency range. Figure 6.: S parameters of the preamplifier shown in Figure 4 and 5. Note that S11 magnitude is practically one because of the high input impedance. The output impedance is fairly well matched up to 10 MHz. Similarly, the forward and reverse transfer parameters, S21 and S12, behave well up to at least 10 MHz. 5

Figure 7.: Setup for measuring the preamplifier. The measurement setup is shown in Figure 7. Full two-port calibration was done on the network analyzer together with the coaxial cables. The RF power and the DC bias voltage on Port 1 were varied to find the compression points. II.2. Preamplifier with high common-mode rejection The same dual operational amplifier can be used to create high common-mode rejection. In fact, if we don t need high input impedance at the same time, using just one side of the dual operational amplifier is sufficient. The schematics is shown in Figure 8. Figure 8.: Preamplifier with high common-mode rejection. 6

The key to the high common-mode rejection is the balanced impedances in the positive and negative input paths. Precision 499-ohm resistors provide the good balance. The forward gain across a 50-ohm load is approximately unity, the input can handle commonmode voltages up to +- 3V DC. The common-mode input resistance, on the other hand is just 499 Ohms, so this preamplifier is best used on Port 2 cables. The measured S parameters are shown in Figure 9. Note that the forward transfer parameter, S21 is -0.38 db at low frequencies. This is due to the attenuation between the 50-ohm source impedance and the 1 kohm one-sided input impedance. The construction is similar to the previous preamplifier, it will be shown in the next section. Figure 9.: S parameters of the preamplifier shown in Figure 7. II.3. Preamplifier with high input impedance and high common-mode rejection If we want a universal preamplifier that can be used either on the Port 1 or on the Port 2 cable, we can cascade the two preamplifiers shown above. The schematics is shown in Figure 10. This amplifier has 6 db forward gain between 50-ohm terminations and for this reason its common-mode input voltage range is limited to +- 1.2 V DC. The measured S parameters are shown in Figure 11. 7

Figure10.: Preamplifier with high common-mode rejection and high input impedance. Figure 11.: Measured S parameters of the preamplifier shown in Figure 10. 8

The second and third preamplifiers require a total of four operational amplifiers, so to utilize the unused half of the second dual operational amplifier in the preamplifier shown in Figure 10, the preamplifier shown in Figure 8 was built up on the same single proto board. The construction is shown in Figure 12. Figure 12.: Construction of the preamplifiers shown in Figures 8 and 10. Conclusions Common-mode input impedance and common-mode rejection ratio are the two main parameters of preamplifiers that help to reduce the cable braid error in Two-port Shuntthrough impedance measurement setups. When the preamplifier is used on the Port 1 cable, high common-mode input impedance is important. Common-mode rejection does not matter on the Port 1 cable. In fact no common-mode rejection is preferred so that DC bias voltage from the source can propagate to the DUT when we need to measure DC bias dependence. When the preamplifier is on the Port 2 cable, common-mode rejection is the important parameter and input impedance does not matter. References [1] Measuring Milliohms and Picohenrys in Power Distribution Networks, DesignCon 2000, available at http://www.electricalintegrity.com/paper_download_files/dc00_measuringmiliohms.pdf [2] How the Braid Impedance of Instrumentation Cables Impact PI and SI Measurements, DesignCon 2019, January 2019, Santa Clara, CA [3] Accuracy Improvements of PDN Impedance Measurements in the Low to Middle Frequency Range, DesignCon 2010, February 1-4, 2010, Santa Clara, CA. Available online at www.electrical-integrity.com [4] Picotest J2113A Semi-Floating Differential Amplifier - Ground Loop Breaker, https://www.picotest.com/products_j2113a.html 9