Spectro p photomete p r V-700 series

Similar documents
V-700 series. UV-Visible/NIR Spectrophotometers

Czerny-Turner mount Double monochromator Fully symmetrical double beam type

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

Croma Enterprise Cromtech India

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

T92+ UV-VIS SPECTROPHOTOMETER

UV / VIS Spectrophotometer

Lambda X65 series. UV/Vis Simplified for your Lab. Gerlinde Wita October 2015

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Lambda 1050 / 950 UV/Vis/NIR

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

instruments Analytical Instruments for Science

V-730Bio UV-Vis Double Beam Spectrophotometer for Bio-Analytical applications

SP-8001 UV/Visible Spectrophotometer

Content Spectrophotometers

Measuring optical filters

SolidSpec-3700 SolidSpec-3700DUV

V-600 Series. UV-Vis/NIR Spectrophotometers Comprehensive line of precision instruments V-630. V-630Bio V-650 V-660 V-670.

CONTENTS Product Accessory Software V /02 V-5100/UV /04 UV-5100B 05/06

Spectro UV-VIS Double Beam Research Spectrophotometer UV-VIS Double Beam

LAMBDA 800 UV/VIS and 900 UV/VIS/NIR Spectrophotometer Systems

UV-VIS Spectrophotometer

V-700 series optional accessories. UV/Vis/NIR Spectrophotometers

Visible & UV/Vis Spectrophotometers

University of Wisconsin Chemistry 524 Spectroscopic Components *

V-700 series. UV-Visible/NIR Spectrophotometers

Hitachi Double Beam Spectrophotometer

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Spectrophotometer simpler to use and higher in dependability thanks to mounting of a large-size color LCD.

UV-VIS Spectrophotometer

BIO SPECTROPHOTOMETER

UV-VIS Spectrophotometer

UV-VIS Spectrophotometer

UV-Vis/NIR Spectrophotometers

UV-VIS-NIR Spectrophotometer

C101-E109 UV Shimadzu UV-VIS Spectrophotometer

mos-500 SPECTROPOLARIMETER Circular Dichroism Spectrometer Everything you expect from a spectropolarimeter

Automated Double Aperture Accessory

Nano-100 Spectrophotometer. Brief introduction

UV-VIS-NIR Spectrophotometer

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

V-730 UV-Vis Double Beam Spectrophotometer

VWR SPECTROPHOTOMETERS

UV-VIS Spectrophotometer

UV/VIS Spectrophotometer

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

UV-VIS-NIR Spectrophotometer UV-3600 C101-E107D

LITE /LAB /SCAN /INLINE:

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Nicolet Evolution 500. UV-Visible Spectrophotometer

Cary 50 UV-Vis UV-VIS. SARIN sas di Leo Temin & C. VARIAN, INC. SPECTROPHOTOMETERS

UV/VIS Spectrophotometer

Hitachi Fluorescence Spectrophotometer

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

The FTNIR Myths... Misinformation or Truth

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

MS260i 1/4 M IMAGING SPECTROGRAPHS

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Cornerstone 260 1/4 m Monochromators

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

1/8 m GRATING MONOCHROMATOR

FTIR Spectrophotometer

SPECIFICATIONS HIGHLIGHTS SUPER AURIUS ADDITIONAL SPECIFICATION BENEFITS PERFORMANCE. High Performance Scans. Derivative Spectra.

CHEM Course Outline (Part 14) Absorption Spectroscopy update 2011 For an html version of 2005 notes, click here

Oriel Cornerstone 130 1/8 m Monochromator

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

Basic Components of Spectroscopic. Instrumentation

Thermo Scientific SPECTRONIC 200 Education

OPTIZEN SERIES UV-VIS SMART SPECTROPHOTOMETER

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

StarBright XLT Optical Coatings

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

INTERNATIONAL INTERCOMPARISON OF WAVELENGTH SCALE AND PHOTOMETRIC SCALE OF SPECTROPHOTOMETRY LABORATORIES CENAM - NRC - INMETRO - NIST.

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

PRODUCT BROCHURE. Affordable Lab Technology

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Spotlight 150 and 200 FT-IR Microscopy Systems

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

Microscope-Spectrometer

Company synopsis. MSU series

Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA)

IBIL setup operation manual for SynerJY software version

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Maya2000 Pro Spectrometer

MANUAL BMS SPEC5000 Spectrophotometer

Components of Optical Instruments

SPECTRAL IRRADIANCE DATA

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

ScanArray Overview. Principle of Operation. Instrument Components

Oriel MS260i TM 1/4 m Imaging Spectrograph

GENESYS 20 GENERAL PRACTICES AND INFORMATION

Spectrophotometer. Operational Manual

TECHNICAL MEMORANDUM

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Lab Junior Educational UV-VIS Spectrometer

Transcription:

Spectrophotometer p V-700 series

V-700 Series UV-Vis/NIR Spectrophotometers V-730 SBW=1.0 nm Class-leading high S/N V-730BIO New irm & Spectra Manager V-750/760/770 Wavelength-independent dynamic range V 780 New! V-780 New! Highly sensitive measurement in NIR

New Features 1. Wavelength-independent dynamic range V-750/760/770/780 2. High resolution as 1.0 nm bandwidth 3. High signal to noise ratio 4. New model: High sensitivity in NIR 5. Wide dynamic range in NIR V-770/780 6. Stable measurement platform 7. Alignment-free lamp replacement 8. Spectra Manager II & CFR 9. irm-1000 10.Upgraded accessories V-730 V-730/750/760/770/780 V-780 V-730/750/760/770/780 V-730/750/760/770/780 V-730/750/760/770/780 V-730/750/760/770/780 V-730/750/760/770/780

1.Wavelength-independent dynamic range V-750/770/780 Linearity up to 4 absorbance in wide UV-Vis wavelength range 5 Ranitidine Food Food Food Nickel sulfate hydrochloride Yellow 4 Red 2 Blue 2 4 Abs 3 2 1 0 190 400 600 800 900 Wavelength [nm]

1.Wavelength-independent dynamic range Ranitidine hydrochloride Food Yellow 4 Food Red 2 Food Blue 2 Nickel sulfate 228 nm 314 nm 427 nm 522 nm 611 nm 722 nm 5 5 5 5 5 5 4 4 4 4 4 4 3 3 3 3 3 3 Abs Abs Abs Abs Abs Abs 2 2 2 2 2 2 1 1 1 1 1 1 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 1 2 3 4 5 0 0 1 2 3 4 5 6 0 0 1 2 3 4 5 Conc. Conc. Conc. Conc. Conc. Conc. [mg/100ml] [mg/100ml] [mg/50ml] [mg/50ml] [mg/50ml] [g/200ml] Abs=0.4546 Conc R 2 =1.0000 Abs=0.4337 Conc R 2 =0.9997 Abs=0.9277 Conc R 2 =1.0000 Abs=0.7786 Conc R 2 =0.9996 Abs=0.8611 Conc R 2 =0.9995 0 0 5 10 15 20 25 Abs=0.2014 Conc R 2 =1.0000

1.Wavelength-independent dynamic range V-750/770/780 Excellent linearity up to 5 absorbance using KMnO 4 solution 6 5 4 3 2 1 0 0 5 10 15 20 Abs=0.2993 Conc R 2 =0.9977

1.Wavelength-independent dynamic range V-760 Linearity up to 6 absorbance in wide UV-Vis wavelength range 7 6 Ranitidine Food Food Food Nickel sulfate hydrochloride Yellow 4 Red 2 Blue 2 Abs 4 2 0 187 400 600 800 900 Wavelength [nm]

1.Wavelength-independent dynamic range Ranitidine hydrochloride Food Yellow 4 Food Red 2 Food Blue 2 Nickel sulfate 7 228 nm 314 nm 427 nm 522 nm 611 nm 722 nm 7 7 7 7 7 6 6 6 6 6 6 5 5 5 5 5 5 Abs 4 3 Abs 4 3 Abs 4 3 Abs 4 3 Abs 4 3 Abs 4 3 2 2 2 2 2 2 1 1 1 1 1 1 0 0 0 0 0 0 0 5 10 15 0 5 10 15 0 1 2 3 4 5 6 7 0 2 4 6 8 10 0 2 4 6 8 0 10 20 30 40 mg/100ml mg/100ml mg/50ml mg/50ml mg/50ml g/200ml Abs=0.4580 Conc R 2 =1.0000 Abs=0.4379 Conc R 2 =0.9997 Abs=0.9307 Conc R 2 =1.0000 Abs=0.7794 Conc R 2 =0.9999 Abs=0.8457 Conc R 2 =0.9990 Abs=0.2016 Conc R 2 =0.9998

1.Wavelength-independent dynamic range V-760 Excellent linearity up to 8 absorbance using KMnO 4 aqueous solution 8 6 Abs 4 2 0 0 5 10 15 20 25 30 mg/50ml Abs=0.2984 Conc R 2 =0.9994

(1) Optimization with High-order Diffraction Light Cut-off Filter V-650/660/670 U340 B370 B460 Y48 O58 R66 V-750/770/780 U340 B370 L39 Y44 Y48 O58 R66 V-760 U340 B370 L39 Y44 Y48 O58 R66 BP60

(2) Ultra-high Resolution ADC, 24 bit V-750/760/770/780 32-times higher resolution than 18 bit in V-600

(3) Offset-free Signal acquisition in S, R, D V-650/660/670 Sector Mirror D Timing Circuit S ADC V-750/760/770 Sector Mirror PMT Pre-amplifier R Sample Hold Timing Circuit PMT Pre-amplifier ADC

2. High resolution as 1.0 nm bandwidth Emission line of D2 lamp V-630 V-730 Resolution test of EP -Toluene/Hexane SBW=1.483 Resolution=2.0954 V-730 Shimazu UV-1800 SBW=0.974 Resolution=1.94

Noise Level of V-730 Specification RMS Noise 0.00004 Abs RMS Noise=0.000016 Pass

Dynamic Range of V-730 Abs 3 with caffeine aqueous solution Abs 3.5 3.5 3 2.5 2 3 2.5 2 1.5 1 1 0.5 0 0 0 0.5 1 1.5 2 2.5 3 3.5 0 20 40 60 Conc [mg/l] Abs=0.0499 Conc R 2 =0.9999

Dynamic Range of V-730 Abs 3.5 with KMnO 4 aqueous solution Abs 4 3.5 3 2.5 2 15 1.5 1 0.5 0 0 50 100 150 200 250 Conc [mg/l] Abs=0.0155 Conc R 2 =0.9997

3. High signal to noise ratio V-730/750/760/770/780 V-750 Enhanced signal-to-noise ratio by improving the light source power supply Time course data at 500 nm 0.000065 0.000106 V-650

4. New model: High sensitivity in NIR V-780 High S/N in NIR 100 80 Optical System Light Sources Single monochromator, Czerny-Turner mount Double beam type Deuterium lamp, Halogen lamp Grating UV/VIS: 1200 lines/mm plane grating NIR: 600 lines/mm plane grating Detector Wavelength Range Spectral Bandwidth 0.05 Photomultiplier tube, Peltier cooled InGaAs detector 190 to 1600 nm UV/VIS:0.1, 0.2, 0.5, 1, 2, 5, 10, L2, L5, L10, M1, M2 nm NIR:0.2, 0.4, 1, 2, 4, 10, 20, L4, L10, L20, M2, M4 nm Cut-off filter for 1.3 μm band for optical communication 0.04 InGaAs PbS %T 60 40 20 %T 002 0.02 0 0 850 1000 1200 1400 1600 Wavelength [nm] -0.02 1200 1250 1300 1350 Wavelength [nm]

4. New model: High sensitivity in NIR

4. New model: High sensitivity in NIR High resolution in NIR The vibration spectrum of CO2 The spectrum of NIR notch filter 90 80 60 %T 40 20 0 950 1000 1050 1100 1150 Wavelength [nm]

4. New model: High sensitivity in NIR New accessories - Integrating sphere - Absolute reflectance measurement unit Absolute reflectance spectrum of anti-reflection coat tfor NIR A wide variety of application Band gap measurement of Si Band Gap=1.13 13 ev -5 degree -20 degree -40 degree -60 degree

5. Wide dynamic range in NIR V-770/780 WI Lamp Brightness control of light source by digital feedback Sector Reference Monochromator PbS ] Control (S+R=Constant) DAC Sample CPU Outdated instruments (not V-600): The bandwidth and gain could only be adjusted for the optical signal in NIR. To obtain the stable optical signal intensity, ty, the bandwidth dt could be changed depending on the wavelength to be used but the high resolution could not obtain in low-energy range of light sources. For the instrument with the fixed bandwidth, if the bandwidth is too large, the optical signal may be saturated depending on the wavelength to be used.

6. Stable Measurement Platform V-730/750/760/770/780 Holmium glass filter is used for checking the spectrophotometer performance everyday. Test items: Peak position Wavelength accuracy Peak intensity Photometric accuracy FWHM Resolution Spectrum comparison Overall spectrum profile [Daily check] program Display of message when D2 and WI lamps has been used for more than 1000 hours (New!) Validation program Instrument self-diagnosis function Display of lamp operation time

7. Alignment-free Lamp Replacement The design of the socket deuterium lamp and socket tungsten halogen lamp facilitates light source over replacement, simplifies maintenance and reduces operation error. Single beam spectra Lamp1 Lamp2 Lamp3 Lamp4 Validation results Inspection 1 2 3 4 Items Wavelength Pass Pass Pass Pass Accuracy Photometric Pass Pass Pass Pass Accuracy Noise Level Pass Pass Pass Pass Baseline Pass Pass Pass Pass Flatness

8. Spectra Manager II & CFR

Standard Programs Measurement Programs Spectra Measurement (Improved!) Quantitative Analysis (Improved!) Time Course Measurement Dual-Wavelength Time Course Measurement (New!) Parallel Time Course Measurement (Cell Changer) Fixed Wavelength Measurement Abs/%T Meter Validation (Improved!) Daily Check (New!)

Standard Programs Analysis Programs Spectra Analysis JASCO Canvas Enzymatic Reaction Rate Calculation Film Thickness Analysis Color Analysis (Compatible with international standards!) X-Unit Conversion Photon Time-Axis Offset Peak Normalization UV/Vis Kramers-Kronig Transform Channel Conversion Data Dump Data Accumulation Arithmetic between Channels Arithmetic between Data

Spectra Measurement Data processing functions Correction: Noise elimination, smoothing, arithmetic operations, derivatives, KM transform, x-axis conversion, relative reflectance correction Result display: Photometric value, peak detection, peak area, FWHM, spectrum comparison, quick quantitation, film thickness calculation Statistical calculations Statistical calculations (average, standard deviation, coefficient of variation) can also be performed for a specified number of measurements. Sequential measurements Flowchart measurement Autosampler available

Quantitative Analysis Quantitative analysis (from creating the calibration curve to performing the quantitative analyses) can be performed using one program package Sequential measurements Autosampler available

Dual-Wavelength Time Course Measurement Kinetics measurement can be performed by dual wavelength. The difference between dual photometric value and the ratio of dual photometric value can be plotted.

Expanded Functions Sequential measurements Enhanced Basic mode Measurements can be performed using a sequence sheet in which h measurement types, sample names and comments are specified. The sequence sheet can be saved and utilized again. Sequence Tab Programs Spectra Measurement Quantitative Analysis Fixed Wavelength Measurement The response time is automatically determined depending on the selected bandwidth and scan speed so that the spectrum profile does not become broad. The data interval is also automatically determined depending on the selected bandwidth.

Optional Programs Programs for Biochemical Applications Protein Nucleic Acid Measurement (Improved!) Kinetics Analysis Temperature Control Measurement (Improved!) Programs for Quantitation Spectrum Quantitative Measurement (New!) Spectrum Quantitation CLS Quantitative Measurement PCR Quantitative Measurement PLS Quantitative Measurement PCA Chromaticity/Turbidity Measurement (Compatible with international standards!)

Optional Programs Programs for Versatile Applications Interval Scan Measurement Temperature Interval Measurement Macro Command Program Name for Color Analysis Color Diagnosis (Compatible with international standards!) Color Matching Color Matching for Color Materials Luminous Color Measurement ASTM Color Analysis Saybolt Color Analysis

Optional Programs Programs for Material Analysis Solar Transmittance/Reflectance Calculation (Compatible with international standards!) Solar Transmittance/Reflectance Measurement (Compatible with international standards!) Sample Haze Calculation (Compatible with international standards!) UPF Calculation (Compatible with international standards!) UPF Measurement (Compatible with international standards!) Absolute Reflectance Spectra Measurement Absolute Reflectance with Variable Incident Angle Measurement Phase Difference Spectra Measurement Multi-Layer Film Thickness Analysis UV Shield Factor Calculation l Band Gap Calculation Film Thickness and Refractive Index Average Reflectance Calculation

Optional Programs Compatible with International Standards Programs Color Analysis [Color Diagnosis] program Chromaticity/Turbidity Measurement Color Diagnosis Solar Transmittance/Reflectance Calculation Solar Transmittance/Reflectance Measurement Sample Haze Calculation l UPF Calculation UPF Measurement

Enhanced DNA Melting Analysis Program Not just Tm and H, S can be calculated Fitting method or van t Hoff plot method can be selected

9. irm-1000 USB memory available Analysis programs for DS type are installed as default Enriched standard programs Increased applicable printers

irm data can be moved to Spectra Manager using USB flash drive Analysis programs for PC type are as standard

Increased Applicable Printers Thermal printer in wide width, enabling the print of spectrum Non-thermal type of compact printer Print image of Printy4 Support of color printing by ESC/P-R EPSON Printer (compatible with ESC/P-R)

Standard Programs Measurement Programs Spectra Measurement Quantitative Measurement Time Course Measurement Fixed Wavelength Measurement Macro Command Abs/%T Meter Validation program Daily Check (New!) Analysis Programs Spectra Analysis Enzymatic Reaction Rate Calculation Film Thickness Analysis Color Analysis program

Optional Program Name Components Bio Package Protein Nucleic Acid Measurement (Improved!) Parallel Time Course Measurement (Cell Changer) Kinetics Analysis Temperature Control Measurement DNA Melting Analysis

10. Updated Accessories Compatible with V-500/600 series accessories Model No. Name NQF-781 Vacuum Sipper NPF-782 Peristaltic Sipper NQF-783 Vacuum Sipper with Long-Path Cell ISV-922/ISN-923/ISN-901i 60-mmɸ Integrating Sphere ILV-924/ILN-925/ILN-902i 150-mmɸ Integrating Sphere PIN-903i Horizontal Sampling Integrating Sphere ARV-913/ARN-914/ARN-915i Absolute Reflectance Measurement Unit (synchronous) ARSV-916/ARSN-917/ARSN- 918i Absolute Reflectance Measurement Unit (asynchronous) ARMV-919/ARMN-920/ARMN- 920/ARMN Automated Absolute Reflectance 921i Measurement Unit SLM-907 Specular Reflection Unit SLM-908 Specular Reflection Unit (accommodating 6-inch silicon wafers)

10. Upgraded Accessories NQF-781 Vacuum Sipper ISV-922/ISN-923/ISN-901i 60-mmɸ Integrating Sphere Space-saving Absolute Reflectance Measurement Unit USB communication Improved sample compartment lid Improved sample holder

Conclusion V-730 Class-leading specification V-730BIO Quite satisfactory function of Bio market V-750/760/770 Wavelength-independent dynamic range V 780 New! V-780 New! Highly sensitive measurement in NIR