USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

Similar documents
USER S MANUAL. Rail-mounted temperature transmitter ATL

IO.AS-dP.01(ENG) APLISENS MANUFACTURE OF PRESSURE TRANSMITTERS AND CONTROL INSTRUMENTS USER S MANUAL. DIFFERENTIAL PRESSURE TRANSMITTER TYPE AS-dP

SEPARATOR P20G TYPE USER S MANUAL

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Installation and Operating Manual

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

PRetrans Table of contents

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

MODEL AT-10 ANALOG TRANSMITTER

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Isolators A3/1. Vibration Transducer Supply Unit Series

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Temperature Input Module for Zone 1 Series 9482/32

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

MACX MCR-UI-UI-UP(-SP)(-NC)

Electromotoric actuators for stroke valves

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

DIGITAL PANEL METER N24 AND N25 METER SERIES

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

OPTITEMP TT 10 C/R Technical Datasheet

USER S MANUAL SMART TEMPERATURE TRANSMITTERS LI-24L LI-24G

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Operating Instructions

OPTITEMP TT 20 Technical Datasheet

Operating Instruction

MINI MCR-SL-UI-I-LP-NC

N24, N25 DIGITAL PANEL METER

Phase-sequence Phase-loss Relay

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Zelio Control Measurement Relays

Analog Universal Module HART for Zone 2 Series 9468/33

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

MINI-PS AC/24DC/1.3

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

SINEAX B 811 Power Pack with additional Functions

SINEAX U 553 Transducer for AC Voltage

AUG / 99 P S I P M E

Level Switch NRS 2-50 NRS Original Installation Instructions English

Electromotoric actuators for valves

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

INSTRUCTION MANUAL Vibration Meter

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

Temperature Transmitter itemp RTD DIN rail TMT 127

Industrial Pressure Transducers

Thermocouple - Transducer

Isolators A3/1.

AC/DC Current Oscilloscope Probe Model SL261

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolated Module TRPxxxxxP 系列产品

Mounting method DIN rail mounting or screw mounting Screw mounting Mass [g] Material Case: Plastics PCB: FR-4

Isolating Repeater Input Series 9163

Operating Manual. isolate501

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

TEMPERATURE CONTROLLER RE21 TYPE

SINEAX TI 807 Passive DC signal isolator

Theta 20A / 20V. Technical Data Sheet. Special Features

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

XY-Stages series 5102

Precipition Sensor with analogue Intensity Output ,

374 FC/375 FC/376 FC Clamp Meter

TRANSMITTER CSA CSA CSA-528. Instruction Manual EN C III

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Product Manual 5202 Pulse isolator

Operating instructions Fail-safe delay timer AZS About this document. Content

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Submersible pressure sensor For water and wastewater Model LW-1

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

Power supply CP-T 48/20.0 Primary switch mode power supply

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Digital Input Output Module for Zone 2 Series 9470/33

Submersible pressure sensor For oils and fuels Model LF-1

AFC Series AFC -20HG AFC-20SE

312, 316, 318. Clamp Meter. Users Manual

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

Instruction Manual MSC710 MSC710-U MSC710-I

Power supply CP-E 24/2.5

User and Safety Manual ProLine P224xx P1

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

D6020S - D6020D INSTRUCTION MANUAL. D SIL 2 Powered Isolating Driver. Hart, DIN-Rail and Termination Board, Models D6020S, D6020D

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Transcription:

(ENG) DECEMBER 2017 USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 ISOLATOR - SIGNAL CONVERTER TYPE SP 11 CURRENT SIGNAL ISOLATOR WITHOUT AUXILIARY POWER TYPE SP 02 APLISENS S.A., 03-192 Warszawa, ul. Morelowa 7 tel. +48 22 814 07 77; fax +48 22 814 07 78 www.aplisens.pl, e-mail: aplisens@aplisens.pl

Symbols used Symbol Description Carefully follow the information in this document to ensure safety and full functionality of the device. Information particularly useful for the installation and use of the device. Information particularly useful for the installation and use of the device by Ex. Information on the disposal of used equipment. BASIC REQUIREMENTS AND SAFETY OF USE The producer takes no liability for damage resulting from incorrect installation of the device, neglecting to keep the device in proper technical condition, and using the device for purposed other than its intended purpose. Installation should be conducted by qualified personnel, authorized for installation of electrical equipment and measuring devices. The installer is responsible to conduct the installation according to this manual as well as laws and standards of safety and electromagnetic compatibility applicable for this kind of installation. In any installation equipped with measuring devices, there is an injury hazard from compressed agent in case of a leak. Follow all safety requirements during the installation, use, and inspection of the display. In case of malfunction, disconnect the device and return it to the producer or an authorized service unit for repair. In order to minimize the possibility of malfunction and the resulting hazard to personnel, avoid installing the device in dangerous environment where there is a possibility of the following: Mechanical impact, excess shock and vibration. Excess temperature fluctuation. Steam condensation, dusting, icing. Installation of intrinsically safe devices must be conducted very carefully, following all standards and laws applicable for installations of this kind. Changes and alterations introduced in production documents may anticipate the update of user's paper documents. Up-to-date instruction manuals are available on producer's website at www.aplisens.pl

CONTENTS 1. INTRODUCTION... 2 2. SAFETY PROCEDURES... 2 3. CONSIGNMENT CONTENTS... 2 4. TRANSPORT AND STORAGE... 3 4.1. Transport... 3 4.2. Storage... 3 5. WARRANTY... 3 6.1. Intended use and features... 3 6.2. Construction and dimensions... 3 7. INSTALLATION... 4 8. CONNECTING... 4 8.1. Connecting the ZSP-41 and ZSP-41/2... 4 8.2. Connecting the SP-11... 7 8.3. Connecting the SP-02... 8 9. TECHNICAL PARAMETERS... 9 9.1. Electrical parameters of ZSP-41 and ZSP-41/2... 9 9.2. Electrical parameters of SP-11... 10 9.3. Electrical parameters of SP-02... 10 9.4. Permissible operating conditions:... 11 9.4.1. Mechanical resistance... 11 9.4.2. Housing protection class... 11 9.4.3. Housing... 11 9.5. Marking... 12 10. INSPECTION... 13 10.1. Periodical inspection... 13 10.2. Non-periodical inspection... 13 11. SCRAPPING, DISPOSAL... 13 12. ADDITIONAL INFORMATION... 13 1

1. INTRODUCTION The subject of this user s manual are rail-mounted signal converters (isolators) type ZSP-41, ZSP-41/2, SP-11 and SP-02. The manual includes data, hints, and recommended action for installation and use of the converters, as well as troubleshooting tips. 2. SAFETY PROCEDURES Read this instruction carefully prior to, installation, startup, or any other work. Installation and maintenance can only by conducted by qualified personnel, authorized to install electrical equipments and measuring devices. Use the device according to its intended use, without exceeding maximum acceptable parameters. Prior to assembly or disassembly of the device, be sure to disconnect the power source. It is not acceptable to conduct any repair or otherwise tamper with the electronic circuit of the device. Damage assessment and possible repair can only be made by the producer or an authorized unit. Do not use the device when it is damaged. If malfunction occurs, disconnect the device. 3. CONSIGNMENT CONTENTS Along with the device, the user receives the following: a) Product certificate, functioning as a warranty card; b) Declaration of conformity (on customer's request); c) User s manual designated IO.ZSP-41.SP-11.SP-02(ENG) Positions b), c) are available from the website www.aplisens.pl 2

4. TRANSPORT AND STORAGE 4.1. Transport When transported, the devices should be packed in individual and/or group packaging and carried on a covered means of transport. The packaging should be secured against shifting and atmospheric weather effects. 4.2. Storage The device should be stored in the manufacturer's packaging, in a covered room, free of vapor and corrosive agents, where temperature and relative humidity do not exceed maximum acceptable limits. 5. WARRANTY The producer provides warranty under the conditions specified in Product Certificate that works as a warranty card. Warranty will be void if the device is not used according to its intended use, the user does not follow this instruction manual, the device is handled by unqualified personnel or the construction has been tampered with. 6. CONSTRUCTION 6.1. Intended use and features Rail-mounted Signal Converters (isolators) are intended to operate in automatic adjustment systems wherever a galvanic separation of system input or output signal is required. They also enable to change analogue signals of 0...20mA, 4...20mA, 0...10V. Also, versions with nonstandard analogue signals are available. Moreover, the ZSP-41/2 is installed wherever additional duplication of output signals is required. 6.2. Construction and dimensions All elements of the isolators electronic systems are installed on a printed circuit board. A front panel with clamps is welded to the circuit board. The entire set is assembled in housing made of plastic. Signal converters have switches to selected input and output signals, accessible after sliding the printed circuit board out of the housing. 3

Figure 1. Housing - dimensions 7. INSTALLATION Isolator housing allows for installation on the following rails: TS-32 (EN 50 035), TS-35 (EN 50 022). Rail-mounted Signal Converters must be used in conditions specified in this user manual. Clamp connection configuration and typical operation configuration is illustrated in figure 2, 5, 8, 11. Selection of input and output signals with switches while isolators are energized does not cause damage. 8. CONNECTING All connection and installation steps must be performed with power disconnected. 8.1. Connecting the ZSP-41 and ZSP-41/2 The ZSP-41 isolator is only equipped with one input clamp block, mounted to clamps 1-2. After selecting dual-line converter, the connection must be reclamped to clamps 3-4. 4

(Power) (Loop) 4 20mA two-wire Figure 2. ZSP-41 connection diagram SWITCHES IN OUT 1 2 3 4 5 6 0-20mA 0-20mA - - - - - - 0-20mA 4-20mA - + - - - - 0-20mA 0-10V - - - + - - 4-20mA 0-20mA - - + - - - 4-20mA 4-20mA - + + - - - 4-20mA 0-10V - - + + - - 0-10V 0-20mA - - - - + + 0-10V 4-20mA - + - - + + 0-10V 0-10V - - - + + + PD 0-20mA - - + - - - PD 4-20mA - + + - - - PD 0-10V - - + + - - Figure 3. ZSP-41 Selecting input and output signals with switches OWC version Input Output DP2 DP4 Dip 1 2 1 2 3 4 1 2 3 4 4 20mA + + + - + + - + - + 0 20mA + + + + - + - - - - 0 10V + + - + - + + - + - PD - + + - + + Figure 4. ZSP-41 - Selecting input and output signals with switches OW version 5

(Power) Figure 5. ZSP-41/2 connection diagram. Output 1 Output 2 Input Dip 1 2 3 4 5 6 1 2 3 4 5 6 4 20mA + - + - + - - + - + - - 0 20mA - - - - - - - + - + - - 0 10V - + - + - + - + - + + - PD + - + - + - - - Figure 6. ZSP-41/2 - Selecting input and output signals with switches OWC version Input Output 1 Output 2 Dip 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 4 20mA - + - + + - + + - + - + - + - + 0 20mA - + - + + + - + - - - - - - - - 0 10V - + - + - + - + + - + - + - + - PD + - + - + - + + Figure 7. ZSP-41/2 - Selecting input and output signals with switches OW version (+) Switch ON (-) Switch OFF (PD) Two-wire transmitter 6

8.2. Connecting the SP-11 Figure 8. SP-11 connection diagram INPUT SWITCHES 1 2 3 4 4 20mA - + - - 0 20mA - - - - 0 5mA - - + - 1 5mA - + + - 0 10V + - - + 2 10V + + - + Figure 9. SP-11 - Selecting input and output signals with switches OWC version INPUT SWITCHES 1 2 3 4 4 20mA + - + + 0 20mA + + - + 0 5mA + + - - 1 5mA + - + - 0 10V - + - + 2 10V - - + + Figure 10. SP-11 - Selecting input and output signals with switches OW version (+) - Switch ON (-) - Switch OFF 7

8.3. Connecting the SP-02 Figure 11. SP-02 connection diagram 8

9. TECHNICAL PARAMETERS 9.1. Electrical parameters of ZSP-41 and ZSP-41/2 Two-wire power supply 24V DC ±20% Power consumption <2 VA with ZSP-41 <3 VA with ZSP-41/2 When switching on in the ZSP-41 isolator, the maximum temporary power consumption is about 3,5VA (power necessary to start up the internal converter) Input signal Input resistance Output signal Output resistance Insulation type Resistance to electrical breakdown Conversion errors - basic error (***) - temperature change effect - load resistance change effect - power voltage change effect 0...20mA, 4...20mA, two-wire (4 20mA + converter power supply) 0...10V 50kΩ (voltage input) 50Ω (current input) 0...20mA, 4...20mA, 0...10V 0...500 Ω (current output) 1 kω (voltage output) optoelectronic 1.5kV AC 50Hz 1min ±0.16% ±0.1%/10 C ±0.1%/100Ω (current output) ±0.1% with 1kΩ (voltage output) ±0.1% (***) ERROR VALUE REFERS TO RANGE SETTING 4...20mA/4...20mA WITHOUT POWER SUPPLY TO INPUT CONVERTER. WITH OTHER SETTINGS (WITHOUT ADDITIONAL CALIBRATION) BASIC ERROR IS 0.25% - not applicable to OWC version. 9

9.2. Electrical parameters of SP-11 Two-wire power supply Power consumption Input signal Input resistance Output signal Output resistance Insulation type Resistance to electrical breakdown Conversion errors - basic error (***) - temperature change effect - load resistance change effect - power voltage change effect 9 36 V DC <1 VA 0...20mA, 4...20mA, 0...5mA, 1...5mA 0...10V, 2...10V 50kΩ (voltage input) 50Ω (current input) 4...20mA 0...( Usup[V]-9V)/0,025A [Ω] Max. 500Ω optoelectronic 1.5kV AC 50Hz 1min ±0.16% ±0.1%/10 C ±0.1%/100Ω ±0.1% (***) ERROR VALUE REFERS TO RANGE SETTING 4...20mA/4...20mA WITHOUT POWER SUPPLY TO INPUT CONVERTER. WITH OTHER SETTINGS (WITHOUT ADDITIONAL CALIBRATION) BASIC ERROR IS 0.25% - not applicable to OWC version. 9.3. Electrical parameters of SP-02 Input voltage Input signal Output signal Output resistance Insulation type Resistance to electrical breakdown Conversion errors - basic error - temperature change effect - load resistance change effect - power voltage change effect 3.5V + Iout x R L 4...20mA 4...20mA 0...10V 0...500 Ω (current output) 2 kω (voltage output) transformer 1.5kV AC 50Hz 1min ±0.16% ±0.1%/10 C ±0.1%/100Ω ±0.1% 10

9.4. Permissible operating conditions: Ambient temperature +5 ºC 60 ºC Relative humidity do 80% Atmospheric pressure Working position 9.4.1. Mechanical resistance Stroke: acc. to PN-EN 60068-2-27, 31 50g/11ms Sinusoidal vibration: acc. to PN-EN 60068-2-6, Fc test; Up to 1,6mm; 2 25Hz; Up to 4g with 25 100Hz; 9.4.2. Housing protection class acc. to PN-EN 60529:2003 IP20 9.4.3. Housing 80...120kPa any Type Housing material Width/Length/Height Weight ME 12,5 (PHOENIX) Polyamide 12,5/114,5/99 mm 0.1 kg 11

9.5. Marking Power supply isolator signal converter type ZSP 41 ZSP-41/1 standard version ZSP-41/1 / special version Non-standard input signal Power supply isolator signal converter signal multiplier type ZSP 41/2 ZSP-41/2 standard version ZSP-41/2 / / / special version Input signal Output signal 1 Output signal 2 Isolator signal converter type SP-11 Single-line version: SP-11/1 standard version SP-11 /1 / special version Non-standard input signal Dual-line version SP-11/2: SP-11/2 standard version SP-11 /2 / / special version Non-standard input signal Line 1 Non-standard input signal Line 2 Current signal isolator without auxiliary energy type SP-02 SP-02/ standard version Number of lines (1 or 2) SP-02/0 10V / special version (with voltage output 0 10V) Number of lines (1 or 2) 12

10. INSPECTION 10.1. Periodical inspection Periodical inspection must be conducted according to user standards in force. While inspecting, check the condition of electrical connections on clamps (firmness of connections) and the stability of fixing. 10.2. Non-periodical inspection If the device is exposed to mechanical damage, electrical overvoltage or it works improperly conduct inspection as necessary. If there is no signal on the transmission line or signal value is incorrect, check the condition of the cable, the condition of connections on clamps, etc. Check if the power voltage value and load resistance is correct. If the line is functional, check the operation of the device. 11. SCRAPPING, DISPOSAL Used or damaged devices must be scrapped according to EU Directive (2002/96/EU) on waste electrical and electronic equipment, or returned to the producer. 12. ADDITIONAL INFORMATION The producer retains the right to implement structural and technological alterations that do not lower the device parameters. 13