WIRELESS MODBUS GATEWAY WGW410

Similar documents
PLUS WGW420 WIRELESS GATEWAY 868MHz

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

Industrial Modbus I/O Modules

Modbus communication module for TCX2: AEX-MOD

PROCESS & TEMPERATURE CONTROLLERS

Data Acquisition Modules/ Distributed IO Modules

SPECIFICATION. Online UPS 3000VA

1 What s in the shipping package?

RSMFX-2R MULTIFUNCTIONAL

WLS (Wireless Locating System)

DTM.OCS.S/N - Modbus Level Transmitter

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

The Rosemount 848T Wireless Temperature Transmitter

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

SV613 USB Interface Wireless Module SV613

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

High Performance Process & Temperature Controllers

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Accutech BR20. DIN rail mounted base radio

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

02/11/2015

Excellent low-cost Process & Temperature Controllers

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

SHIMADEN DIGITAL INDICATORS

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5

SYSTEM SENSOR WIRELESS REMOTE INDICATOR PRODUCT SPECIFICATION

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

TxBlock-USB Transmitter

Isolators A3/1.

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor

Lifetime Power Energy Harvesting Development Kit for Wireless Sensors User s Manual - featuring PIC MCU with extreme Low Power (XLP) Technology

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Technical Information Barrier RB223

JUMO Wtrans Receiver with Wireless Data Transmission

02/11/2015

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

AERINOS Profisens - Wireless IoT Platform

The wireless alternative to expensive cabling...

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

The wireless alternative to expensive cabling...

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

P5201 Universal Programmable Transmitters with Galvanic Isolation

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Netbiter IO Extender 4RO 6RTD 8DIO DAIO 8AIV 8AIIS

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Rail mounted Temperature Transmitter TH102/TH102-Ex

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES

[ tima-datasheet-en v11.1 ]

A6500-UM Universal Measurement Card

em4 em4 alert em4 alert 2G

z488xx RF Switches/Multiplexers PXI

Power Meter Series PM3200 Functions and characteristics

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

ONE CALIBRATOR ONLY MAIN FEATURES:

The wireless alternative to expensive cabling...

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Q.raxx A101-8 slimline RS / EC

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Temperature Transmitters - Head Mounted

Catalog

Temperature transmitter itemp PCP DIN rail TMT 121

1 INTRODUCTION ORDER CODE / INFORMATION

Catalog

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

RN-41-SM. Class 1 Bluetooth Socket Module. Features. Applications. Description. Block Diagram. rn-41sm-ds 9/9/2009

The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement.

The wireless alternative to expensive cabling...

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

CompoBus/D-type Digital Controller

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

MEMOCAL 2000/2000S. Hand-held calibrator

FA Wireless SS Terminals

z8801 Local Oscillator PXI

Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

SWT 3000 Teleprotection technical data siemens.com

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Accutech RT10. Wireless RTD temperature field unit

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Temperature Measurement

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Accutech AP10. Wireless absolute pressure field unit

Transcription:

WIRELESS MODBUS GATEWAY WGW410 The Tekon Wireless Modbus Gateway WGW410 is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to their reduced dimensions, they can be easily installed in junction boxes or in the control cabinet. It receives the information transmitted by the Universal Wireless Temperature Transmitter THW401 and makes it available on the RS485 interface with Modbus protocol. Additionally, the first 8 addressed wireless transmitters can be read through the 4 to 20mA analog outputs. KEY FEATURES SUPPORTS UP TO 16 THW401 TEMPERATURE TRANSMITTERS UP TO 2 KM LINE OF SIGHT (LoS) LONG DISTANCE RANGE COMMUNICATION REAL TIME TRANSMISSION PROCESS AND AMBIENT TEMPERATURE, RF SIGNAL STRENGTH AND BATTERY LEVEL 1 SECOND NETWORK REFRESH TIME RS-485 INTERFACE WITH MODBUS PROTOCOL Dimensions: 98mm x 66,22mm x 35,80mm Weight: 120g Material: PA UL 94 V0 Protection Index: IP40 8 X ANALOG OUTPUTS (4...20MA) ON SITE BATTERY AND RF SIGNAL STRENGTH VERIFICATION PA123730100-PA123710100.DS.ENG.V01.2.2018 TEKON ELECTRONICS AVEIRO, PORTUGAL P.: +351 234 303 320 M.: +351 939 992 222 E.: sales@tekonelectronics.com

TECHNICAL SPECIFICATIONS POWER SUPPLY Voltage supply 12 VDC to 24 VDC +/- 10% Current consumption 70 ma @ 12 VDC / 45 ma @ 24 VDC (@ 25 ºC) Power consumption 0.85 W @ 12 VDC / 1.1 W @ 24 VDC (@ 25 ºC) Power up time 900 ms RF TRANSMISSION Transmission frequency Transmission interval Maximum output power Sensitivity Range 2.4 GHz (worldwide) 60 ms per remote node 18 dbm -108 dbm 2 Km LoS RS-485 INTERFACE Protocol Baud rate Galvanic isolation Modbus RTU [4800; 115200] Kbps 1KV ANALOG OUTPUTS signal Max. load Out of range Fault signal (e.g. sensor fault) Sample cycle Protection Power on or reset initial value 8 x 4 to 20 ma 360 Ω @ 12VDC / 1 KΩ @ 24VDC [3.2;4.0] ma and [20.0;20.2] ma 3.1.mA or 20.4 ma 1s to 24h (configurable) Against reversed polarity Surge protection Last written value FACTORY SETTINGS Wireless Network ID 0x00 Modbus Slave Address 0x00 Baud rate 9600 bps Parity None Stop Bits 2 HOUSING Material PA UL 94 V0 Color RAL 7035 Weight 120 g Cross-section of cables 2.5mm 2 Protection type Antenna connection IP40 SMA Reverse Polarity 2

OPERATING ENVIRONMENT Ambient range Storage range Relative humidity -20 to 80 ºC (-4 to 176 ºF) -20 to 80 ºC (-4 to 176 ºF) 95 %, without condensation CERTIFICATIONS AND APPROVALS EN 61326 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 EN 300 228 EN 300 440 Electrical equipment for measurement, control and laboratory use. EMC requirements. Electrostatic discharge immunity test Radiated, Radio-Frequency, Electromagnetic Field Immunity test Electrical fast transient/brust immunity test Surge Immunity Test Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive MODBUS HOLDING REGISTER TABLE (FUNCTION 0X03 READ HOLDING REGISTER; FUNCTION 0X10 WRITE HOLDING REGISTER) FOR OTA (OVER THE AIR CONFIGURATION) - THW401 Description in ºC x 100 Transmission interval in seconds probe type (see table below) Node Model (see table below) Battery Voltage in Volts x 100 RSSI in dbm Information life time in seconds Board in ºC x 100 Variable type INT32 UINT32 UINT16 UINT16 UINT16 UINT16 UINT32 INT16 Address (1) + 18 + 20 +21 + 22 + 23 + 24 + 26 Permissions Read Read/Write Read/Write Read Read Read Read Read Range According to sensor type [0 to 86400] [1 to 99] [1 to 99] [3.00 to 20.00] [70 to 180 ] [0 to 86400] Node 0 0 18 20 21 22 23 24 26 Node 1 27 45 47 48 49 50 51 53 [-20.00 to 80.00] Node n n*27 (n*27)+18 (n*27)+20 (n*27)+21 (n*27)+22 (n*27)+23 (n*27)+24 (n*27)+26 probe type Code probe type Code PT100-2 Wires 1 Thermocouple K 10 PT100-3 Wires 2 Thermocouple J 11 PT100-4 Wires 3 Thermocouple T 12 PT500-2 Wires 4 Thermocouple S 13 PT500-3 Wires 5 Thermocouple R 14 PT500-4 Wires 6 Thermocouple N 15 PT1000-2 Wires 7 Thermocouple B 16 PT1000-3 Wires 8 Thermocouple E 17 PT1000-4 Wires 9 End node models THW401 2 Code (1) = [ NodeID x 27] 3

MODBUS HOLDING REGISTER TABLE (FUNCTION 0X03 READ HOLDING REGISTER; FUNCTION 0X10 WRITE HOLDING REGISTER) FOR ANALOG OUTPUT CONFIGURATION Input Minimum Value Input Maximum Value Number of failed messages to alarm Modbus Address Link Alarms Damaged signal Description Communication failure signal Device Status Temperature *100 Variable type INT16 INT16 UINT16 UINT16 UINT16 UINT16 UINT16 UINT16 INT32 UINT16 Address Offset (2) Offset + 1 Offset + 2 Offset +3 Offset +4 Offset + 5 Offset + 6 Offset + 7 Offset + 8 Offset + 10 Permissions Read/Write Read/Write Read/Write Read only Read only Read only Read only Read only Read only Read only Range Temperature that defines 4mA Temperature that defines 20mA 2...10 N/A 0... 3 204 (20.4mA) 310 (3.10mA) 1... 4 N/A N/A Info Default Values Min. read (ºC) Max. read (ºC) Time refresh cycles to alarm Additional Modbus Address to read 0: All Off 1: On +Com. Fail Off 2: Off + Com Fail On 3: On + Com Fail On when sensor is damaged (ma) x 100 when communication alarm condition is reached (ma) x 100 Device status code: 1 Normal Operation; 2 Damaged 3 OK but out of range 4 - Com. error read (converted to ºC x 100) equivalent to given (ma) x 100 0 100 3 3 204 310 N/A N/A N/A 0 432 433 434 435 436 437 438 439 440 442 1 443 444 445 446 447 448 449 450 451 453 2 454 455 456 457 458 459 460 461 462 464 3 465 466 467 468 469 470 471 472 473 475 4 476 477 478 479 480 481 482 483 484 486 5 487 488 489 490 491 492 493 494 495 497 6 498 499 500 501 502 503 504 505 506 508 7 509 510 511 512 513 514 515 516 517 519 (2) Offset = [432 + IDx11] 4

TECHNICAL DRAWINGS DIMENSIONAL DRAWINGS AND INTERFACE DESIGN MODBUS CONFIGURATION BAUDRATE (BPS) Pin 1 Pin 2 Pin 3 4800 OFF OFF OFF 9600 OFF OFF ON 14400 OFF ON OFF 19200 OFF ON ON 38400 ON OFF OFF 56000 ON OFF ON 57600 ON ON OFF 115200 ON ON ON PARITY Pin 4 Pin 5 None OFF OFF Even OFF ON Odd ON OFF None ON ON Note: 1. Pin 7 is reserved for future use. 2. Pin 8 at ON state connects an internal 120Ω resistance for line adaptation. STOP BITS Pin 6 One ON Two OFF 5

ELECTRICAL CONNECTIONS ANALOG OUTPUT LED CODING LED state Color Meaning Fixed RED loop is open Blinking GREEN The output is in error. Could be out of range, sensor damaged or communication lost. Please see the device status values over the Modbus. Fixed GREEN Correct operation. Current loop is closed, communication between node and gateway OK and rage configured and measured is OK. 6

TEKON ELECTRONICS a brand of Bresimar Automação S.A. Quinta do Simão 3800-230 Aveiro PORTUGAL P.: +351 234 303 320 M.: +351 933 033 250 E.: sales@tekonelectronics.com