Digital Clamp Meter Model: &

Similar documents
True RMS Digital Multimeter Model:

DIGITAL MULTIMETER AUTORANGING

Digital Multimeter, Pen Type

UT207A/208A/209A Operating Manual. Table of Contents

User Manual Digital Clamp Multimeter. model no.: MSR-C600

KMD-S04 Multímetro de bolsillo

MODEL: D03128 CLAMP METER

Model: &

Pocket Size Digital Multimeter Models: and

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Mini Clamp Meter Model:

AC/DC CLAMP METER USER S MANUAL

Model : OPERATING MANUAL Table of Contents (1)

Model UT10A: OPERATING MANUAL Table of Contents (1)

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MS2030 CAT III 600 V A V AUTO RS232

Model UT201/202: OPERATING MANUAL. Table of Contents

CONTENTS MS2033A. 1.Introduction Safety Information...01

Table of Contents Title Page

Digital Multimeter with Backlight

UT207/208. Digital Clamp Multimeter P/N:

Digital Clamp Meter. User Manual

Pocket Size Digital Multimeter with USB Model: A & A

Table of Contents GDM-356. Page

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User Manual Digital Multimeter. model no.: MSR-U1000

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

AMM-1022 Digital Multimeter USER`S MANUAL

DCM730. Digital Clamp Meter User s Manual

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM1190 DIGITAL MULTIMETER

User Manual Digital Multimeter

Model UT20B: OPERATING MANUAL Table of Contents (1)

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Model DIGITAL MULTIMETER

Multifunction Digital

Model UT39A/B/C: OPERATING MANUAL

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

The Meter Structure The Figure 2-1 shows the Meter structure.

DIGIT & POINTER MULTIMETER

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

OPERATOR S INSTRUCTION MANUAL

User Manual. All rights reserved. Specifications are subject to change without notice.

OPERATOR S INSTRUCTION MANUAL

Model UT50D: OPERATING MANUAL. Table of Contents

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

INSTRUCTION MANUAL DIGITAL MULTIMETER

3B SCIENTIFIC PHYSICS

ProfiScale MULTI Multimeter

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

MS8223A. CAT.IIi 600 V

DMM8900 SERIES USERS MANUAL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Title Page Overview Unpacking Inspection Safety Information

User Manual. All rights reserved. Specifications are subject to change without notice.

312, 316, 318. Clamp Meter. Users Manual

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Handheld Digital Multimeter PRO-50A

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

DIGITAL MULTIMETER INSTRUCTION MANUAL

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

374/375/376 Clamp Meter

400Amp True RMS AC/DC Clamp Meter Model EX613

USER'S MANUAL DMR-6700

DIGITAL CLAMP METER Use s Manual

374/375/376 Clamp Meter. Users Manual

AX-C Introduction. 2. Safety Information

1.General instructions Specifications Description...7

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

OPERATING INSTRUCTION

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Dawson DDM190. Digital Multimeter User s Manual

MS2109A AC/DC Clamp Meter. User Manual. Contents

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

R/C SMD Tweezers Multimeter Model RC200

UT132 Series Manual. UT132 Series. Palm Size Digital Multimeter. Operating Manual -1-

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

Transcription:

Digital Clamp Meter Model: 72-7224 & 72-7226 1

SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032, and 61010-2-033 in Pollution Degree 2, Measurement Category (CAT II 600V, CAT III 300V) and double Insulation. Do not operate the meter or use test leads if they appear damaged, or if the meter is not operating properly. There are no user-serviceable parts in this product. Refer servicing to qualified personnel. Do not apply voltage between the COM and OHM terminals, while in the resistance measuring state. Do not measure current with the test leads inserted into the voltage or OHM terminals. To avoid electrical shock and personal injury, do not attempt to measure voltage higher than 600V AC/DC, although the readings may be obtained. Do not expose the instrument to direct sunlight, extreme temperature or humidity. Before measuring current, check the fuses and turn the power to the circuit off before connecting the meter to the circuit. Disconnect circuit power and discharge all high voltage capacitors before testing continuity. diode, resistance, capacitance or current. Do not use the meter around explosive gas or vapour. When using the test leads, keep your fingers behind the finger guards. Remove test leads from the meter before opening the meter case or battery door. Never operate the meter with the cover removed or the battery door open. Use only the test leads supplied or the protection may be impaired. Probe assemblies for mains measurements shall be rated as appropriate for measurement category III according to IEC 61010-031 and shall have a voltage RATING of at least the voltage of the circuit to be measured. Replace the batteries as soon as the low battery indicator appears on the display. Remove dead batteries from the meter or if it is not going to be used for a long time. Never mix old and new batteries together, or different types of batteries. Never dispose of batteries in a fire, or attempt to recharge ordinary batteries. Before replacing the battery, turn off the meter and disconnect all the test probes. To prolong battery life turn off the meter after use. WHAT S INCLUDED Digital multimeter User manual Test lead One 9V battery Carrying bag 2

SYMBOL GUIDE AC (Alternating Current) DC (Direct Current) AC or DC Grounding Double insulated Warning Low battery Continuity Buzzer Diode Fuse Application around and removal from UNINSULATED HAZARDOUS LIVE conductors is permitted. Conforms to European Union directives This symbol signifies the product complies with both USA and Canada requirements. FUNCTIONS 1. Input terminals 2. LCD Display 3. Function buttons x 3 4. Range selector 5. Trigger: press and release the trigger to open and close the detector jaw. 6. Hands guard: protects hands from touching the dangerous area. 7. Detector jaw: designed to pick up the AC and DC current flowing through the conductor. It transfers current to voltage. The tested conductor must pass centrally through the jaw. 3

OPERATING PARAMETERS Operating temperature: 23 C± 5 C Relative Humidity: 85%. Temperature Coefficient: 0.1 (specified accuracy)/1 C DC VOLTAGE 400.0mV 0.1mV ±(0.8%+3) 4.000V 1mV 40.00V 10mV ±(0.8%+1) 600V DC/AC 400.0V 100mV 600V 1V ±(1%+3) Note: The input impedance is 10MΩ. AC VOLTAGE 4.000V 1mV 40.00V 10mV ±(1%+5) 400.0V 100mV 600V DC/AC 600V 1V ±(1.2%+5) Notes: Input Impedance: 10MΩ Frequency Response: 40Hz~400Hz AC conversion type: Average-responded, calibrates the reading to be RMS by sine wave input. RESISTANCE 400.0Ω 100mΩ ±(1.2%+2) 4.000kΩ 1Ω 40.00kΩ 10Ω ±(1%+2) 400.0kΩ 100Ω 600Vp 4.000MΩ 1kΩ ±(1.2%+2) 40.00MΩ 10kΩ ±(1.5%+2) 4

DIODE AND CONTINUITY 1mV Displays approximate forward voltage drop 600Vp Note: The open circuit voltage is about 1.48V. 100mΩ When 10Ω, the buzzer beeps. 600Vp Notes: The open circuit voltage is about 0.45V. The buzzer may beep when the resistance of a circuit under test is 10Ω~100Ω. The buzzer does not beep when the resistance of a circuit under test is higher than 100Ω. FREQUENCY 10Hz 0.001Hz 100Hz 0.01Hz 1kHz 0.1Hz ±(0.1%+3) 10kHz 1Hz 600Vp 100kHz 10Hz 1MHz 100Hz 10MHz 1kHz For reference only Notes: Input Sensitivity: 100kHz, 300mVrms >100kHz, 600mVrms >1MHz, 800mVrms Input Amplitude at: 10Hz~100kHz: 30Vrms a 300mVrms 100kHz~10MHz: 30Vrms a 600mVrms DUTY CYCLE Range Resolution Accuracy Overload protection 0.1%~99.9% 0.1% For reference only 600Vp 5

DC CURRENT 40.00A 0.01A ±(2%+5) 400.0A 0.1A ±(2%+3) 400A DC/AC Notes If the reading is positive, the current direction is from down to up (See Figure 10, with the front panel facing up, and rear panel facing down). Do not release the jaw suddenly as the built-in Hall components are very sensitive to magnetic force, heat and mechanical stress, any shock will cause read errors. To measure DC current and obtain a more precise reading, perform the following steps: 1. Hold the meter, and press the trigger to open the detector jaw. Center the conductor within the detector jaw, then release the trigger gently until the detector jaw is completely closed. Make sure the conductor to be measured is placed at the center of the detector jaw, otherwise it will produce ±1.0% measuring deviation based on the stated accuracy. 2. Open the jaw and remove the detector from the current conductor. 3. Press REL to display zero. 4. Repeat Step 1. AC CURRENT Range Resolution Accuracy 40.00A 0.01A ±(2.5%+8) 400.0A 0.1A ±(2.5%+5) Frequency Response 50Hz~60Hz Overload Protection 400A DC/AC Note: To measure AC current and obtain a more precise reading, perform the following steps: 1. Hold the meter, and press the trigger to open the detector jaw. Center the conductor within the detector jaw, then release the trigger gently until the detector jaw is completely closed. Make sure the conductor to be measured is placed at the center of the detector jaw, otherwise it will produce ±1.0% measuring deviation based on the stated accuracy. 2. Open the jaw and remove the detector from the current conductor. 3. Press REL to display zero. 4. Repeat Step 1. 6

OPERATION Measuring DC/AC Voltage The DC voltage ranges are 400mV, 4V, 40V, 400V and 600V. The AC voltage ranges are 4V, 40V, 400V and 600V. To measure DC/AC voltage, perform the following steps: 1. Insert the red test lead into the Hz Duty% terminal and the black test lead into the COM terminal. 2. Turn the range selector to and DC measurement mode and auto range are set as default. To measure AC voltage press SELECT switch to AC measurement mode, and press REL to switch to manual range measurement mode. 3. Connect the test probes with the object being measured. The measured value shows on the display. Note: When a measurement has been completed, disconnect the test probes from the circuit under test, and remove the test leads from the input terminals. Measuring Resistance The resistance ranges are 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ and 40MΩ. To measure the resistance, perform the following steps: 1. Insert the red test lead into the Hz Duty% terminal and the black test lead into the COM terminal. 2. Turn the range selector to Ω. Press REL to switch from auto range as default to manual range during the measurement if required. 3. Connect the test probes with the object being measured. The measured value shows on the display. Notes: To obtain a more precise reading, you could remove the object being measured from the circuit when measuring. When a measurement has been completed, disconnect the test probes from the circuit under test, and remove the test leads from the input terminals. 7

DIODE CHECK Use the diode test mode to check diodes, transistors and other semiconductor devices. In diode test mode, a current is sent through the semiconductor junction and the voltage drop across the junction is measured. A good silicon junction drop is between 0.5V and 0.8V. To test a diode out of a circuit, perform the following steps, 1. Insert the red test lead into the Hz Duty% terminal and the black test lead into the COM terminal. 2. Turn the rotary switch to. Press SELECT to switch from diode measurement mode as default to continuity measurement mode if needed. 3. For forward voltage drop readings on any semiconductor component, connect the red test probe to the component s anode and the black test probe to the cathode. Notes: To obtain a more precise reading, you could remove the object being measured from the circuit when measuring. When a measurement has been completed, disconnect the test probes from the circuit under test, and remove the test leads from the input terminals. CONTINUITY CHECK To test continuity, perform the following steps: 1. Insert the red test lead into the Hz Duty% terminal and the black test lead into the COM terminal. 2. Turn the rotary switch to and press SELECT button to choose the measurement mode. The buzzer will sound if the resistance of a circuit under test is less than 50Ω. The buzzer may sound if the resistance of a circuit under test is between 50Ω and 100Ω. The buzzer does not sound if the resistance of a circuit under test is higher than 100Ω. Note: When a measurement has been completed, disconnect the test probes from the circuit under test, and remove the test leads from the input terminals. 8

FREQUENCY MEASUREMENT The frequency ranges are 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz and 10MHz. To measure frequency, perform the following steps: 1. Insert the red test lead into the Hz Duty% terminal and the black test lead into the COM terminal. 2. Turn the rotary switch to Hz. 3. Connect the test probes with the object being measured. The measured value shows on the display. Note: When a measurement has been completed, disconnect the test probes from the circuit under test, and remove the test leads from the input terminals. DUTY CYCLE MEASUREMENT The duty cycle range is 0.1%~99.9%. To measure duty cycle, perform the following steps, 1. Insert the red test lead into the Hz Duty% terminal and the black test lead into the COM terminal. 2. Turn the rotary switch to Hz and press REL to select duty cycle measurement mode. 3. Connect the test probes with the object being measured. The measured value shows on the display. Note: When a measurement has been completed, disconnect the test probes from the circuit under test, and remove the test leads from the input terminals. 9

DC/AC CURRENT MEASUREMENT The current ranges are 40.00 A and 400.0 A To measure current, perform the following steps, 1. Turn the rotary switch to 40.00 A or 400.0 A and press SELECT to switch between DC (as default) and AC measurement mode. 2. Press the trigger to open the detector jaw. 3. Centre the conductor within the detector jaw, then release the trigger gently until the detector jaw is completely closed. Make sure the conductor to be measured is placed centrally otherwise it will produce an inaccurate measurement. The meter can only measure one conductor at a time. If more than one conductor is measured, incorrect readings will be displayed. To obtain a positive reading when measuring DC current, the current must flow in the direction from the rear of the meter to the front. 4. Do not release the jaw suddenly as the built-in Hall components are very sensitive to magnetic force, heat and mechanical stress, any shock could cause damage and create read errors. Notes: Press REL to subtract a stored value from the present measurement value, then a differential measurement result is displayed. When a measurement has been completed, open the detector jaw and remove the meter from the conductor. The operating temperature must be 0ºC ~40ºC when measuring current. Change to AC: Model: 72-7224: Change to AC by using average response method. Input sine wave, then adjust the reading until it is same as the effective value. Model: 72-7726: Combine AC and True RMS response method. Input sine wave to adjust. Non sine wave must follow the data below to adjust: Peak factor: 1.4~2.0, add 1.0% on the stated accuracy. Peak factor: 2.0~2.5, add 2.5% on the stated accuracy. Peak factor: 2.5~3.0, add 4.0% on the stated accuracy. 10

MAINTENANCE Replacing the battery When the meter displays the low battery symbol, replace the battery immediately in order to maintain normal operation. Disconnect and remove all test probes from any live source and the meter. Open the battery cover on the rear case with a screwdriver. Remove the old battery and fit a new 9V battery into the battery holder. Replace the battery cover. Screw Battery Cleaning Clean the meter with a clean, soft cloth. Do not use any chemicals, abrasives or solvents that could damage the meter. Clean the terminals with a mild detergent, as dirt on the terminals can affect readings. 11

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. Made in China. PR2 9PP Man Rev 1.0 12