Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Similar documents
TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

PAD - Heavy Duty Differential Pressure Trasmitter

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Digital conductivity transmitter

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Electro-Magnetic Flowmeters COPA-XE

Series Smart Pressure Transmitter

RCM DIRECT READING FLOWMETER

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

Level Measurement Continuous level measurement Radar transmitters

Proven Measurement for A World of Applications

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Magnetostrictive Level Transmitter

OPTIFLUX 5000 Technical Datasheet

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Coriolis Massflowmeter

The transducer component converts the measured signal and displays the actual value.

Non-Submersible Industrial Pressure Transducer

Flow Measurement SITRANS F M

Magnetic Flowmeter Systems

OPTIFLUX 5000 Technical Datasheet

Model Sono-Trak Transit Time

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Metal tube variable area flowmeters for gases, liquids and steam

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

EN-2018 MAGNETIC FLOW METERS

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Advanced instrumentation solutions crafted with highest precision

Digital inductive conductivity transmitter

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Micro MV P2DAAA. Custody transfer accuracy Built-in multivariable 3-in-1 transmitter. Daily. Zigbee wireless radio. Extended length battery backup

Accutech DP20. Wireless differential pressure field unit

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Ambient Conditions. Operating Conditions. Pressure

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

ph or ORP Transmitter

Level Measurement Continuous level measurement Radar transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

TIDALFLUX 2300 F Technical Datasheet

Rosemount 3101, 3102, and 3105

OPTIMASS 1000 Technical Datasheet

Magnetostrictive Level Transmitter

Compact Orifice Flow Meter

Ultrasonic level transmitter, non-contact

Flow Measurement SITRANS F M

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

UTM10 Series Ultrasonic Transit-time Flowmeters

Conductivity Analyzer

FOSTEN AUTOMATION SÉRIE F500-RD

Echotel Model 910 Ultrasonic Level Switch

Technologies, Solutions, and Applications. Guided Wave Radar for Level

SITRANS L Level instruments

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS LR 300: High Performance Radar for Level Measurement

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

DRS390 High stability, flange mounting

Radar Level Measurement micropilot FMR 130 for stilling wells

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

A New Generation of Pressure Transmitters

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Kotron Sentinel Model 804 RF Level Transmitter

LST100 Ultrasonic level transmitter for upstream oil and gas

Submersible pressure sensor For water and wastewater Model LW-1

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Electromagnetic Flowmeter Hygienic/Sanitary

OPTITEMP TT 20 Technical Datasheet

914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Submersible pressure sensor For superior applications Model LF-1

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Submersible pressure sensor For oils and fuels Model LF-1

Using the AcuDew Moisture Transmitter

U Series Non-Contact Ultrasonic Transmitter

Coriolis Mass Flow Meter Model TM

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Process display RIA 261

A New Generation of Pressure Transmitters

Applications Features

Accutech GP10. Wireless gauge pressure field unit

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter

AT200 External Mount Magnetostrictive Level Transmitter

OEM radar transmitter, for aggressive media level measurement

Smart Pressure Transmitter

Transcription:

Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

State-of-the-art measurement solutions Flow Measurement We offer multiple flow measurement technologies to measure liquids, gases, steam and corrosive fluid Level Measurement Our specialized level measurement instruments consists of contact, non-contact, differential, and ultrasonic, to cater to all types of varied process needs Temperature Measurement Our field and panel mount designs offer an array of technologies to choose from Pressure Measurement PRESSURE MEASUREMENT Our pressure measurement ranges provide compelling accuracy and reliability ACCESSORIES To improve the efficiency and durability of a product additional accessories are always of great importance Accessories TEKVALSYS Diagnostic systems that provide real time validation and monitoring TekValSys INDICATOR CONTROLLER A full line of digital panel meters, indicators and control instrumentation for process indication and control 02 03

Technology Solutions For Process Measurement Automation & Control 04 05

Flow Measurement Tek-Trol s range of flowmeter monitors mass and volumetric flow of liquids, gases and steam with premium accuracy, high stability and robust operation Coriolis Mass Flowmeter - Tek-Cor 1100A Liquids and Gas SS 316L 0.1% or 0.2% or 0.5% For mass flow rates please refer the catalog Electromagnetic Flowmeter - Tek-Flux 1400A Repeatability For 0.1% accuracy: ±0.05%, For 0.2% Compatible conductive liquids Power Requirements Process Connections Resolution/ Display 4 to 20 ma Pulse Direct Mount: -58 F to 257 F (-50 C to 125 C) Remote Mount: -58 F to 392 F (-50 C to 200 C) 18 to 28 VDC or 85 to 220 VAC Flanges, Tri-Clamp or Threads, DIN or ANSI OLED Display Electrode Material: 316 SS or Hastealloy C Liner Materials: PTFE or Hard Rubber ±0.5% of F. S. For flow range please refer the catalog Repeatability 0.15% 4 to 20 ma; optional HART, Pulse or RS 485 Sensor (Remote Mount): -50 F to 158 F (-45 C to 70 C) Enclosure Ratings NEMA 4 x (IP67), 7, 9 Agency Approval UL (ClassⅠ) (Div Ⅰ) Converter: -40 F to 122 F (-40 C to 50 C) Direct Mount: 40 F to 122 F (-40 C to 50 C) Power Requirements 18 to 28 VDC or 85 to 220 VAC Process Connections 150# to 900# ANSI Resolution/ Display High intelligence, with back light LCD display 285 psi for ½ to 6 (10 bar for 15 mm to 150 mm) 285 psi for 8 to 24 (16 bar for 200 mm to 600 mm) 145 psi for 28 (10 bar for 700 mm) Enclosure Ratings IP68 06 Agency Approval CE 07

Vortex Flowmeter - Tek-Vor 1300C Repeatability Power Requirements Process Connections Resolution/ Display Enclosure Ratings Agency Approval Liquids, Gas, and Steam 304 SS and 316 LSS ±1% of reading Gas: 197 ft/s (60 m/s) Liquid: 23 ft/s (7 m/s) Steam: 230 ft/s (70 m/s) 0.3% of reading 4 to 20 ma and Pulse; Optional HART or Modbus RS 485 Standard: 302 F (150 C) Medium: 482 F (250 C) High: 662 F (350 C) 13.5 to 42 VDC Wafer or ANSI Flange LED See Flange Rating NEMA 4 x (IP67) CE Ultrasonic Clamp-On Flowmeter - Tek-Clamp 1200A Thermal Mass Flowmeter - Tek-Thermal 1700B Air and Nitrogen 316 SS ±0.5% of FS Flow Velocity See Velocity ranges in Catalog Repeatability 0.2% 4 to 20 ma with Pulsed output; Optional HART or RS 485-40 F to 302 F (-40 C to 150 C) Power Requirements 13.5 VDC to 42 VDC Process Connections YZ" NPT Resolution/ Display 5 Digit Display 232 PSI (16 bar) Enclosure Ratings IP65 Compatible Liquids Sensor: Aluminum alloy or Plastic alloy 1% 1200A-S2: ½" to 4", 1200A-M2: 2" to 28", 1200A-HS: ½" to 4", 1200A-HM: 2" to 28" Repeatability 0.2% 1200A-100F1: RS 485, 4 to 20mA and frequency output 1200A-100M: RS 485, 4 to 20 ma and frequency output 1200A-100H: RS 232 32 F to 320 F (0 C to 160 C) Power Requirements 1200A-100F1: 85 to 264 VAC or 24 VDC, 1200A-100M: 8 to 36 VDC 1200A-100H: 90 to 230 VAC or Ni-MH battery Process Connections ANSI 150#, 300#, 600#, 900# or AWWA Flanges Resolution/ Display 1200A-100F1: 2 H x 20 W, 2 line x 20 characters 1200A-100M: 2 H x 20 W, 2 line x 20 characters 1200A-100H: 4 H x 16 W, 4 line x 16 characters As per flange rating Enclosure Ratings 1200A-100F1: IP65, 1200A-100M: IP57 1200A-100H: IP65 08 09

Orifice meters - Tek-DP 1610A Liquids and Gas SS304, SS316, SS316L as standard. Hastelloy-C, Monel, PP, PVC, PTFE coated Standard -20 F to 100 F (-28 C to 37 C), optional -40 F to 1200 F (-40 C to 648 C) Indicator Controller Cone Flowmeter - Tek-DP 1620A A full line of digital panel meters, indicators and control instrumentation for process indication and control Liquids and Gas SS304, SS316, SS316L as standard. Hastelloy-C, Flow nozzles - Tek-DP 1630A Venturi Tubes - Tek-DP 1640A Liquids and Gas Carbon steel for weld in type, 304SS, 304L SS, 316SS, 316L SS for holding ring type and Ni, Cr, Mo Alloy Steel for flanged type Explosion-Proof Loop-Powered Indicators- Tek-Lcd 7800B Series Display Display Update Rate Over Range Feet & Inches display: 0.60 (15.2 mm) high, 0 to 699 FT 11 15/16 IN with 1/16 or 1/8 fraction display Ambient > -25 C: 2 Updates/Second Ambient < -25 C: 1 Update/5 Seconds Level display flashes to 699 FT 11 15/16 IN Volume display flashes 9999999 if over range Under Range Display flashes -999999 Recalibration Normal Mode Rejection Operating Temperature Range Recommended at least every 12 months. 64 db at 50/60 Hz -40 F to 167 F Storage Temperature -40 F to 167 F Relative Humidity Connections 0 to 90% non-condensing Screw terminals accept 12 to 22 AWG wire 5.00 lbs (80 oz, 2.27 kg) Liquids and Gas All standard materials available 10 11

Analog Input Batch Controller - TEK-BATCH 7900A Display Display Update Rate Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs. 5/second (200 ms) Over Range Display flashes 999999 Under Range Display flashes -99999 Recalibration Normal Mode Rejection Operating Temperature Range Recommended at least every 12 months. Greater than 60 db at 50/60 Hz (PD8-6210) Isolation: 4 kv input/output-to-power line. 500 V input-to-output or output-to-p+ supply. T6 Class: -40 F to 140 F T6 Class: -40 F to 65 F Storage Temperature -40 C to 75 C Relative Humidity Connections 0 to 90% non-condensing Screw terminals accept 12 to 22 AWG wire 16.0 lbs (7.26 kg) 12 13

Explosion-Proof Loop-Powered Feet And Inches Level Meter- Tek-Lcd 7801B Display Display Update Rate Five digits (-9999 to 99999) 0.70 (0.05ft) high, 7-segment, automatic lead zero blanking Ambient > -25 C: 2 Updates/Second. Ambient < -25 C: 1 Update/5 Seconds Over Range Display flashes 999999 Under Range Display flashes -99999 Recalibration Normal Mode Rejection Operating Temperature Range Recommended at least every 12 months. 64 db at 50/60 Hz -40 F to 167 F Storage Temperature -40 F to 167 F Relative Humidity Connections Agency Approval 0 to 90% non-condensing Screw terminals accept 12 to 22 AWG wire 5.00 lbs (80 oz, 2.27 kg) FM, CSA, ATEX, CE 14 15

Large Display Batcher- Tek-Batch 7900B Operating Temperature 32 F to 122 F Storage Temperature -40 F to 185 F Humidity Materials Keypad 0-95% Non-condensing Plastic, UL94V-0, Flame retardant Bezel: Textured per matt finish 0.02% FS at -4 F Basic Measurement Resolution Update Automatic Fault Detection Calibration Extended Calibration Real Time Clock Keypad Type: Membrane Keypad with 16 keys Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC Current: 4-20 ma, 0-20 ma, 4-20 ma 16 bit 4 updates/sec Signal over/under-range, Current Loop Broken Software Calibration (no trimmers) Learns Zero and Full Scale of each range using special test mode The Tek-Batch is equipped with a battery backed real time clock with display of time and date. Format: 12 or 24 hour time display; Day, Month, Year, date display SERIES NEMA 4X FLOW COMPUTER- TEK-FC 8000B Operating Temperature -4 F to 131 F Storage Temperature -40 F to 185 F Humidity Materials 0-95% Non-condensing UL, CSA, VDE approved Keypad Keypad Type: Membrane Keypad with 116 0.02% FS at -4 F Basic Material Resolution Update Automatic Fault Detection Calibration Extended Calibration Real Time Clock keys, Keypad Rating: Sealed to NEMA 4X / IP65 Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC Current: 4-20 ma, 0-20 ma, 4-20 ma stacked, 16 bit 4 updates/sec Signal over/under-range, Current Loop Broken Operator assisted learn mode Learns Zero and Full Scale of each range The Flow Computer is equipped with a non-volatile real time clock with display of time and date. Format: 24 hour format for time Day, Month, Year for date 16 17

Accessories Level Measurement Tek-Trol provides wide range of instrumentation accessories, products and configurations for optimum efficiency and durability for all industrial applications Tek-Trol s level measurement devices offers the right solution for your level measuring requirements Manifold Valve - Tek-Manifold 7500A Guided Wave Radar Level Transmitter - Tek-Flex 4100A Compatible liquids, gases, or steam Body, stem, valve assembly: SS 316; Stem packing: PTFE 450 F (232 C) 6000 PSI (400 bar) Liquids and Bulk Solids SS 316, PTFE 2 lbs. (no probe) ±0.039" ( 1 mm) or 0.02% of measured distance, whichever is greatest Cable: up to 60, Rod: Up to 10 Repeatability <.08 4 to 20 ma Electronics: -40 F to 158 F (-40 C to 70 C) Process/Probe: -40 F to 398 F (-40 C to 203 C) Power Requirements 12-28 VDC (4 - Wire) Process Connections 1 - YZ" NPT Resolution/ Display 0.0008" -14.50 to 580 PSI Enclosure Ratings NEMA 6 Agency Approval Optional ATEX 18 19

Two Wire TDR Level Transmitter with HART - TEK-FLEX 4100C Liquids and Bulk Solids 316 SS, PTFE ±0.4" (10mm) Up to 10' with minimum dielectric constant of 0.3 Repeatability ±0.02" (0.5 mm) 4 to 20 ma/hart Electronics: -40 F to 158 F (-40 C to 70 C) Process/Probe: -40 F to 398 F (-40 C to 203 C) Power Requirements 16 to 36 VDC 2-wire Process Connections 1 ½" NPT Resolution/ Display 5 Digits -14.50 PSI to 580 PSI (-1 bar to 40 bar) Enclosure Ratings NEMA 4X 2 lbs. (without probe) 2-Wire Loop Powered TDR Level Meter - Tek-Flex 4100B Liquids 316 SS, PTFE ±0.039 ( 1 mm) or 0.02% of measured distance, whichever is greatest Up to 60 Repeatability ±0.02 (0.5 mm) 4-20 ma Electronics: -40 F to 158 F (-40 C to 70 C) Process/Probe: -40 F to 398 F (-40 C to 203 C) Power Requirements 12 to 28 VDC (2-Wire) Process Connections ¾ NPT Resolution/ Display 5 Digits -14.50 PSI to 580 PSI (-1 bar to 40 bar) Enclosure Ratings NEMA 6 Agency Approval Optional ATEX 2 lbs. (without probe) Ultrasonic Level Transmitter - Tek-Sound 4200A Liquids and Bulk Solids PVC ±0.25% of max range 9' (2.7 m), 16' (4.9 m), 20' (6.1 m), 30' (9.1 m), 50' (15.2 m), 60' (18.2 m) Repeatability 0.08 4 to 20 ma as Standard or Optional RS 232 or RS 485 or 750 Ω on 4 Wire Electronic Enclosure: -40 F to 140 F (-40 C to 60 C); Temperature Compensation: -40 F to 140 F (-40 C to 60 C) Power Requirements 4 Wire: 115 VAC at 60 Hz or 230 VAC at 50Hz 3 Wire: 12 VDC to 30 VDC Process Connections 1" NPT or 3" NPT Resolution/ Display 3 Digits Up to 72 PSI (5 bar) Enclosure Ratings NEMA 6 (IP68) 4.0 lb (1.8 kg) Agency Approval CE 20 21

Radar Level Transmitter - Tek-Wave 4300A Liquids and Bulk Solids Antenna: Polypropylene (PP) Enclosure Aluminum ±0.25% of max range 17' (5.1 m), 33' (10 m), 50' (15.2 m), 100' (30.4 m) Repeatability 0.08 4 to 20 ma HART -40 F to 140 F (-40 C to 60 C) Power Requirements 12 to 30 VDC (2 Wire) Process Connections 1½" NPT or 2" NPT Resolution/ Display No Display Up to 72 PSI (5 bar) Enclosure Ratings NEMA 6 (IP68) 6 Lbs. Agency Approval FM Differential Pressure Level Transmitter - Tek-Hydro 4500A-D Two Wire Ultrasonic Level Transmitter - TEK-Sound 4200B Liquids and Bulk Solids Enclosure Transducer: PTFE Powered Coated Aluminum 2 lbs. 0.5% 0.25 m to 4 m Repeatability.08 4 to 20 ma/hart -40 C to 70 C Power Requirements 16 to 36 VDC (2-Wire) Process Connections 1½" NPT Resolution/ Display 5 Digit Display -0.02 to 0.1 Enclosure Ratings IP67 Beam Angle 5.5" From Center 2 lbs. Compatible Liquids See Model Chart ±0.075% of span 1.5 in H₂O to 1450 PSI (0.0037 bar to 100 bar) 4 to 20 ma with HART Process temperature: -40 F to 248 F (-40 C to 120 C) Operating temperature: -40 F to 185 F (-40 C to 85 C) Power Requirements 12 to 45 VDC Process Connections See Model Chart Resolution/ Display 6 Digit Display Enclosure Ratings IP67 (NEMA 4X) Agency Approval FM/FMC, KOSHA KTL, ATEX 22 23

PTFE Submersible Level Transmitter - Tek-Sub 4800A Compatible Liquids Body: PTFE, O-Ring: FKM fluorine rubber Diaphragm: Ceramic (Al₂O₃, 96%) Cable: PTFE or Polyurethane ±0.5% FS 2.8 psig to 15 psig (2 mh2o to 10.5 mh2o) Optional ranges available 150% of span 4 to 20 ma RS 485 or 0.5 to 4.5 VDC -20 F to 160 F (-29 C to 71 C) 2.8 psig to 15 psig Enclosure Ratings IP68 0.9 lb (415 g) Hydrostatic Level Transmitters - Tek-Hydro 4500A-G Compatible Liquids See Model Chart ±0.075% of span 0.21 PSI to 8700 PSI (0.015 bar to 600 bar) 4 to 20 ma HART Process temperature: -40 F to 248 F (-40 C to 120 C) Operating temperature: -40 F to 185 F (-40 C to 85 C) Power Requirements 12 to 45 VDC Process Connections See Model Chart Resolution/ Display LCD display Enclosure Ratings IP67 (NEMA 4X) Agency Approval FM/FMC, KOSHA KTL, ATEX Submersible Level Transmitter - Tek-Sub 4800B Compatible Liquids Body 304 SS, 316 SS Cable: PTFE or Polyurethane ±0.5% FS 5 psig to 20 psig (3.5 mh2o to 14 mh2o), Optional ranges available 4-20 ma, RS-485, 0.5-4.5 VDC Power Requirements 12 to 36 VDC 150% of span Enclosure Ratings IP68 0.9 lbs (408 g) 24 25

0.062 ft Submersible Level Transmitter- Tek-Sub 4800C Compatible Liquids 304 SS, 316 SS 0.25% FS 10 psig to 50 psig (7 mh2o to 35 mh2o), Optional ranges available 4-20 ma, RS-485, 0.5-4.5 VDC -40, ºF to 25 ºF Power Requirements 12 to 36 VDC 150% of Span Enclosure Ratings IP68 0.49 lb (225 g) Validation System Diagnostic systems that provide real-time validation and monitoring TekValSys DP Wastewater Submersible Level Transmitter - Tek-Sub 4800D Compatible Liquids 304 SS ±0.5% FS 5 psig to 20 psig (3.5 mh₂o to 14 mh₂o), Optional ranges available 150% of Span 4-20 ma, RS-485, 0.5-4.5 VDC -40 ºF to 25 ºF Power Requirements 12 to 36 VDC Enclosure Ratings IP68 8.8 lb (4000g) This patented technique has proven to be an extremely powerful tool in ensuring accuracy, providing real-time alerts of meter mismeasurement, and performance shifts, and reducing maintenance overheads on DP systems. Applicable to all types of differential pressure metering systems, including Orifice, Venturi, Cone, Flow Nozzle, and Wedge; TekValSys DP uses 3 Differential Pressure (DP) measurements to monitor the entire pressure field through the meter body. Reduced Financial Exposure to Mismeasurement Reduced Maintenance Cost Reduced Risk to Personnel Health and Safety Assurance of Meter System Performance Possibility of Achieving Financial Payback in Few Days 26 27

TekValSys GC A unique and comprehensive Condition-Based validation software package for Gas Chromatographs (GCs), comprising GCAS software and Panel PC for hazardous or safe areas. As an automated, condition-based monitoring software, TekValSys GC: Provides real time assurance that the GC is operating correctly Analyzes historical data to identify changes and predict future failures Reduces the need for conventional maintenance and unnecessary costs Determines dynamic GC uncertainty for quantification of GC performance Validates that the pressure let down system provides a representative sample Creates a fully auditable database of GC performance Helps to support and increase a technician's competence level 28 29

Temperature Measurement Pressure Measurement Tek-Trol s Temperature measurement devices provides accurate measurement of temperature even in the most challenging conditions Our high-quality pressure measuring devices provides stable, reliable and accurate measurements inprocess industries that requires high-precision measurement solutions Explosion-Proof Temperature Transmitter - Tek-Temp 2100A Explosion-Proof Differential Pressure Transmitter - Tek-Bar 3110A Liquids and Gases See Model Chart 2.4 lb (1.2 kg) ±0.003% of span As per sensor, refer the catalog for details Repeatability ±0.1% typical 4 to 20 ma Without condensing: -40 F to 185 F (-40 C to 85 C) With LCD module: -22 F to 176 F (-30 C to 80 C) Power Requirements 10 to 45 VDC Process Connections See Model Chart Resolution/ Display Optional 5 digit LCD display Enclosure Ratings FM for Class I, Division 1 Agency Approval CE, FM s Range Ability Stability s Pressure Renges Power Requirements Signal Loop Resistance Electrical Connection Process Connection Display Enclosure Rating Compatible gases, steam, liquids Hastelloy C, 316L SS 0.075% of URL 40:1 Turn Down ±0.2% URL/5 yr Process: -40 F to 185 F (-40 C to 85 C) 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) 10.5 to 55 VDC 4 to 20 ma / HART Operation: 0 to 2119 Ω; HART Communication: 250 Ω ½" female NPT conduit ½" male NPT Optional 5 digit LCD 3.43 lb (1.56 kg) NEMA 4 x (IP66) 30 31

Smart Gauge Pressure Transmitter - Tek-Bar 3120B s Range Ability Stability s Pressure Renges Power Requirements Signal Loop Resistance Electrical Connection Process Connection Display Enclosure Rating Compatible gases, steam, liquids Hastelloy C, 316L SS 0.075% of URL 40:1 Turn Down ±0.2% URL/5 yr Process: -40 F to 185 F (-40 C to 85 C) 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) 10.5 to 55 VDC 4 to 20 ma / HART Operation: 0 to 2119 Ω; HART Communication: 250 Ω ½" female NPT conduit ½" male NPT Optional 5 digit LCD 3.43 lb (1.56 kg) NEMA 4 x (IP66) 32 33

Smart Differential Pressure Transmitter - Tek-Bar 3110B Explosion-Proof Gauge Pressure Transmitter - Tek-Bar 3120A s Range Ability Stability s Pressure Renges Power Requirements Signal Loop Resistance Electrical Connection Process Connection Display Enclosure Rating Compatible gases, steam, liquids Hastelloy C, 316L SS 0.075% of URL 40:1 Turn Down ±0.2% URL/5 yr Process: -40 F to 185 F (-40 C to 85 C) 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) 10.5 to 55 VDC 4 to 20 ma / HART Operation: 0 to 2119 Ω; HART Communication: 250 Ω ½" female NPT conduit ½" male NPT Optional 5 digit LCD 3.43 lb (1.56 kg) NEMA 4 x (IP66) s Range Ability Stability s Pressure Renges Power Requirements Signal Loop Resistance Electrical Connection Process Connection Display Enclosure Rating Compatible gases, steam, liquids Hastelloy C, 316L SS 0.075% of URL 40:1 Turn Down ±0.2% URL/5 yr Process: -40 F to 185 F (-40 C to 85 C) 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) 10.5 to 55 VDC 4 to 20 ma / HART Operation: 0 to 2119 Ω; HART Communication: 250 Ω ½" female NPT conduit ½" male NPT Optional 5 digit LCD 3.43 lb (1.56 kg) NEMA 4 x (IP66) 34 18 35 23