PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation User s Guide

Similar documents
ES Arbitrary Signal Generator Board User s Guide

PB1651PWM1 Module. User s Guide

ES PWM I/O Board (48/32-CH) User s Guide

ES Internal Combustion Engine Application User s Guide

ES Compact Failure Simulation Module User s Guide

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

Thermocouple - Transducer

PART NUMBERING SYSTEM

Technical Documentation

External brake resistor AX2090-BW5x

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

High precision measurement system for current and voltage IHC-A/B-RM01/03

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

NI PXI-2557 Specifications

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

SCC-CO20 Isolated Current Output Module

PU202 Level converter & encoder signal generator without potential separation

TETRIS 1000 High Impedance Active Probe. Instruction Manual

NI PXI-2555 Specifications

RSMFX-2R MULTIFUNCTIONAL

FOM-5A, 6A Asynchronous Fiber Optic Modems

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Franck-Hertz Control Unit

Astra-R Kit Wireless Alarm System Operation Manual

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

User Manual EnOcean V 0.1

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

NI SCXI Specifications

Low Noise Variable Gain Low Frequency Voltage Amplifier

PART NUMBERING SYSTEM

Installation Guide Multi Position Servo Controller E1100-MP and E1100-MP-HC

Wireless Room Thermostat Installation and Operation Y6630D1007

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Appendix A: Specifications

Advanced Test Equipment Rentals ATEC (2832)

Low Noise Variable Gain Low Frequency Voltage Amplifier

Current Loop Interface Module M 2025D

Instruction Manual MSC710 MSC710-U MSC710-I

MINI MCR-SL-UI-I-LP-NC

NI PXI-2520 Specifications 80-Channel SPST Relay Module

SPECIFICATION. Online UPS 3000VA

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

Keysight U9397A/C FET Solid State Switch (SPDT)

Galaxy VM. Kit for IP32. Installation 06/

Precipitation Monitor ,

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

SCXI MHz Quad 8x1 50 Ω Multiplexer

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

Positioning Controller. Cable Starting Set. Document ID: rel5883

Bosch Smart Home. Door/Window Contact Instruction Manual

NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

1- or 2-Port, High-Speed, Flexible Data Rate PXI CAN Interface Module

Procontrol P14 89AS30R0100 Module and Application Description Analog Signal Multiplier

Positioning Controller. Cable Starting Set. Document ID: rel5183

Wind Direction Transmitter First Class analogue output x0.1xx

Digital Input Module. ST-1xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

z488xx RF Switches/Multiplexers PXI

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

z47524 PXI Quad SPDT RF Changeover Switch Module

SOM i.mx6. Regulation Information. Simple. Robust. Computing Solutions. Rev 1.1

SPLIT.CONVERTER. User's Manual. Version 2.0

Baro Transmitter PTB x1.073

NI Channel SPST Electromechanical Relay Module

Current Loop Interface Module M-2025C

EMC Installation Guidelines

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

1- or 2-Port, Software-Selectable PXI CAN Interface Module

Fit IPL-R. Instruction Manual (Rev06 - Jun 2018; Firm. Vers.11)

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Operator s Manual. PP016 Passive Probe

BDD-UM 3023 Digital Display

Agilent G1888 Network Headspace Sampler

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

Installation and Operational Instructions for ROBA -switch Type 017._00.2

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

Operator s Manual. PP017 and PP018 Passive Probes

For detailed specifications and ordering info go to

high performance needs great design. Coverpage: AS89000 Datasheet

IF30. User's manual. Description. Table of contents IF30

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

OPERATING INSTRUCTIONS NI Port DeviceNet Module

Circuit Breaker Finder

Industrial motor controller for brushed DC motors 24 VDC

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

SCC-FV01 Frequency Input Module

Analog signal converters CC-E I/I

dmx2pwm 9 channel dimmer setup manual

Operating Instructions for Microwave Level Switch. Model: LNM

Precipition Sensor with analogue Intensity Output ,

Transcription:

PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation User s Guide

Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license. Using and copying is only allowed in concurrence with the specifications stipulated in the contract. Under no circumstances may any part of this document be copied, reproduced, transmitted, stored in a retrieval system or translated into another language without the express written permission of ETAS GmbH. Copyright 2013-2015 ETAS GmbH, Stuttgart The names and designations used in this document are trademarks or brands belonging to the respective owners. V1.0.0 R01 EN - 06.2015 2

ETAS Contents Contents 1 Introduction...................................................... 5 1.1 Features.................................................... 5 1.1.1 Using with a Carrier Board................................ 6 1.1.2 Block Diagram......................................... 6 1.2 Basic Safety Instructions........................................ 7 1.2.1 Correct Use........................................... 7 1.2.2 Labeling of Safety Instructions............................. 7 1.3 RoHS conformity.............................................. 8 1.3.1 European Union....................................... 8 1.3.2 China............................................... 8 1.4 CE marking.................................................. 8 1.5 Taking the Product Back and Recycling............................. 8 2 Hardware........................................................ 9 2.1 Assembly................................................... 9 2.2 Configuration............................................... 10 2.2.1 Jumpers for Ground Reference........................... 10 2.2.2 Relays for the Simulation of Wide-Band Sensors of the Type "LSU5.1" 11 2.2.3 Configuration of Switching-Type Sensors.................... 11 2.2.4 Integration of Lambda Sensor Simulation in LABCAR........... 12 3 Pin Assignment and LEDs........................................... 13 3.1 Front-Facing Connector of the ES1652.2 Carrier Board................ 13 3.2 LEDs...................................................... 14 4 Technical Data.................................................... 15 4.1 Fulfilled Standards and Norms................................... 15 Signal Conditioning for Lambda Sensor Simulation - User s Guide 3

Contents ETAS 5 ETAS Contact Addresses............................................ 17 Index.......................................................... 19 4 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Introduction 1 Introduction This User s Guide describes the PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation. This chapter contains information on the basic functions and the area of use of the PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation. 1.1 Features CAUTION! Some components of the PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation can be damaged or destroyed by electrostatic discharge. Leave the board in the transport packaging until it is installed. The PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation must always be removed from the transport packaging, configured and installed at a workstation that is protected from electrostatic discharge. The PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation is a signal conditioning module for simulating lambda sensors on the ES1652.2 Carrier Board for Signal Conditioning Circuits. The module enables two wide-band and two switching-type sensors to be simulated. It enables the simulation of the following types of lambda sensor: LSU4.x, LSU5.1 ADV4.2 LSF4.x NTK ZFAS The following controllers are supported: CJ135STEP1 Signal Conditioning for Lambda Sensor Simulation - User s Guide 5

Introduction ETAS 1.1.1 Using with a Carrier Board In addition to this module, an analog output and a resistor cascade are required for every lambda sensor simulation (Fig. 1-1). Experimental Target LABCAR-RTPC ES4100 Backplane ES1652 Carrier Board ES1385 Resistor Cascade PB4350DAC Output UP UN VM IP IA ECU Lambda Measurement Fig. 1-1 1.1.2 Block Diagram Lambda Sensor Simulation in the HIL System The functions of the PB1652LAMBDA.1-C and its inputs and outputs are shown in the following block diagram. UN UP + + U N VM + _ Shunt IP IA Path for LSU5.1 SPRUNGSONDE_A/B U_DAC_SPRUNG_A/B 100R 100R JP201 (A) JP301 (B) LSF_A/B Fig. 1-2 Block Diagram of the PB1652LAMBDA.1-C (Wide-band/Switchingtype Sensors) 6 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Introduction An explanation of the abbreviations used: UP: Pump voltage (from the HIL system) UN: Nernst voltage [ECU pin: RE] VM: Virtual ground [ECU pin: IPE] IP: Pump current [ECU pin: APE] IA: Compensating current [ECU pin: MES] 1.2 Basic Safety Instructions Please adhere to the safety instructions in this manuals to avoid injury to yourself and others as well as damage to the device. 1.2.1 Correct Use ETAS GmbH cannot be made liable for damage which is caused by incorrect use and not adhering to the safety instructions. 1.2.2 Labeling of Safety Instructions The safety instructions contained in this manual are shown with the standard danger symbol shown below: The following safety instructions are used. They provide extremely important information. Please read this information carefully. CAUTION! indicates a low-risk danger which could result in minor or less serious injury or damage if not avoided. WARNING! indicates a possible medium-risk danger which could lead to serious or even fatal injuries if not avoided. DANGER! indicates a high-risk, immediate danger which could lead to serious or even fatal injuries if not avoided. Signal Conditioning for Lambda Sensor Simulation - User s Guide 7

Introduction ETAS 1.3 RoHS conformity 1.3.1 European Union 1.3.2 China The EU Directive 2002/95/EU limits the use of certain dangerous materials for electrical and electronic devices (RoHS conformity). ETAS confirms that the product corresponds to this directive which is applicable in the European Union. ETAS confirms that the product meets the product-specific applicable guidelines of the China RoHS (Management Methods for Controlling Pollution Caused by Electronic Information Products Regulation) applicable in China with the China RoHS marking affixed to the product or its packaging. 1.4 CE marking ETAS confirms that the product meets the product-specific applicable European Directives with the CE marking affixed to the product or its packaging. The CE Declaration of Conformity for the product is available upon request. 1.5 Taking the Product Back and Recycling The European Union has passed a directive called Waste Electrical and Electronic Equipment, or WEEE for short, to ensure that systems are set up throughout the EU for the collection, treatment and recycling of electronic waste. This ensures that the devices are recycled in a resource-saving way representing no danger to health or the environment. Fig. 1-3 WEEE-Symbol The WEEE symbol on the product or its packaging shows that the product must not be disposed of as residual garbage. The user is obliged to collect the old devices separately and return them to the WEEE take-back system for recycling. The WEEE Directive concerns all ETAS devices but not external cables or batteries. For more information on the ETAS GmbH Recycling Program, contact the ETAS sales and service locations (see "ETAS Contact Addresses" on page 17). 8 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Hardware 2 Hardware This chapter describes the assembly and configuration of the PB1652LAMBDA.1- C Signal Conditioning for Lambda Sensor Simulation. 2.1 Assembly To assemble the PB1652LAMBDA.1-C module on the ES1652.2 Carrier Board, proceed as follows: Screw the M3x10 metric spacers supplied with the carrier board onto the protruding screws. Align the pin headers of the module with the female headers of the carrier boards in such a way that they match, i.e. discontinuous pin header on a discontinuous female header and continuous pin header on a continuous female header. Screw the module tight to the carrier board. Signal Conditioning for Lambda Sensor Simulation - User s Guide 9

Hardware ETAS 2.2 Configuration 2.2.1 Jumpers for Ground Reference For the analog circuit to work, the analog output board in the HiL must output the voltage with reference to UBatt. The jumpers establish the connection between Ext. GND_CHx and UBatt. Out_CHx UP_p Ext. GND_CHx UP_n PB4350DAC PB1652LAMBDA.1 AGND -UBatt Note If, in the wiring harness, Ext.GND_CHx of the board is already connected with UBatt, the jumper should be opened! The jumpers are next to the CO100 pin header. CO100 JP100 JP101 JP102 JP103 Fig. 2-1 Position of the Jumpers The functions of the individual jumpers are listed below: Jumper Connects With JP100 UP_SOLL_N_A* ("IN 6") UBatt ("IN 5") (wide-band sensor A) JP101 UP_SOLL_N_B* ("IN 7") UBatt ("IN 5") (wide-band sensor B) JP102 DAC_SPRUNG_GND_A* "IN 8") UBatt ("IN 5") (switching-type sensor A) JP103 DAC_SPRUNG_GND_B* "IN 9") (switching-type sensor B) UBatt ("IN 5") * A, B specify the two sensors simulated with the module Tab. 2-1 Function of Jumpers JP100 - JP103 10 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Hardware 2.2.2 Relays for the Simulation of Wide-Band Sensors of the Type "LSU5.1" For the simulation of wide-band sensors of the type "LSU5.1", relays on the board have to be switched (see Fig. 1-2 on page 6). For this purpose, 12 V has to be applied at Pin 15 ("RELAY_VCC") of the "OUT 1..15" port (see Tab. 3-2 on page 14). The relay for wide-band sensor A is switched when Pin 12 ("RELAY_LSW_A") is connected with GND; the relay for wide-band sensor B is switched when Pin 11 ("RELAY_LSW_B") is connected with GND. 2.2.3 Configuration of Switching-Type Sensors The resistors (200 Ohm) of the switching-type sensors are already present on the modules. External variable resistors can be used by setting the jumpers on the board (P201/JP301 - see Fig. 2-2). SPRUNGSONDE_A/B U_DAC_SPRUNG_A/B 100R 100R JP201 (A) JP301 (B) LSF_A/B Fig. 2-2 Jumpers for the Resistors of a Switching-Type Sensor Signal Conditioning for Lambda Sensor Simulation - User s Guide 11

Hardware ETAS 2.2.4 Integration of Lambda Sensor Simulation in LABCAR The following figure shows an example of how to connect the lambda sensor simulation to LABCAR. VM_B VM_A ExtGND_CH07 ExtGND_CH06 Out_CH04 6 8 17 18 Lambda external BoB 150 VM ExtGND_CH04 Out_CH05 ExtGND_CH05 Out_CH06 ExtGND_CH06 Out_CH07 ExtGND_CH07 IA2 UN2 IP2 UN1 IA1 IP1 149 VM ES1652.2 ES1385.1 Out_CH06 IN 1 UP_SOLL_P_A IP_A OUT 1 137 IP1 ExtGND_CH06 IA_A OUT 2 138 IA1 IN 6 OUT 13 UP_SOLL_N_A VM_A UN_A LSU_A OUT 3 Res2 + - 139 155 156 UN1 Res2- Res2+ Out_CH07 IN 2 UP_SOLL_P_B IP_B OUT 4 140 IP2 PB4350DAC1 #2 ExtGND_CH07 IN 7 OUT 14 UP_SOLL_N_B VM_B IA_B UN_B LSU_B OUT 5 OUT 6 Res3 + - 141 142 157 158 IA2 UN2 Res3- Res3+ ECU1 Out_CH08 IN 3 SPRUNGSONDE_A U_DAC_SPRUNG_A OUT 7 OUT 8 143 144 IP3 IA3 LSF_A OUT 9 Res4 + - 145 159 UN3 Res4-160 Res4+ Out_CH09 IN 4 SPRUNGSONDE_B U_DAC_SPRUNG_B OUT 10 OUT 11 146 147 IP4 IA4 LSF_B OUT 12 Res5 + - 148 161 UN4 Res5- -UBatt IN 5 162 Res5+ Fig. 2-3 Connection to LABCAR Note The connections shown in red must be explicitly established! 12 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Pin Assignment and LEDs 3 Pin Assignment and LEDs Once the PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation has been mounted on the ES1652.2 Carrier Board for Signal Conditioning Circuits, the required signals are available over both front-facing connectors. 3.1 Front-Facing Connector of the ES1652.2 Carrier Board IN 1..9 Signal CO100 on Carrier Board 1 UP_SOLL_P_A 18 2 UP_SOLL_P_B 17 3 U_DAC_SPRUNG_A 16 4 U_DAC_SPRUNG_B 15 5 UBatt 14 6 UP_SOLL_N_A 13 7 UP_SOLL_N_B 12 8 DAC_SPRUNG_GND_A 11 9 DAC_SPRUNG_GND_B 10 Housing Protective earth Tab. 3-1 Signals at the "IN 1..9" Connector Note To avoid problems with leakage current detection with the CJ135, we recommend using a galvanically isolated, analog output for addressing UP. Signal Conditioning for Lambda Sensor Simulation - User s Guide 13

Pin Assignment and LEDs ETAS OUT 1..15 Signal (Meaning) [ECU Pin] CO100 on Carrier Board 1 IP_A (pump current sensor A) [APE] 34 2 IA_A (compensating current sensor A) [MES] 33 3 UN_A (Nernst voltage sensor A) [RE] 32 4 IP_B (pump current sensor B) [APE] 31 5 IA_B (compensating current sensor B) [MES] 30 6 UN_B (Nernst voltage sensor B) [RE] 29 7 SPRUNGSONDE_A 28 8 n.c. 27 9 n.c. 26 10 SPRUNGSONDE_B 25 11 RELAY_LSW_B 24 (see section 2.2.2 on page 11) 12 RELAY_LSW_A 23 (see section 2.2.2 on page 11) 13 VM_A (virtual ground sensor A) [IPE] 22 14 VM_B (virtual ground sensor B) [IPE] 21 15 RELAY_VCC 20 (see section 2.2.2 on page 11) Housing Protective earth Tab. 3-2 Signals at "OUT 1..15" Connector 3.2 LEDs 1 2 3 4 5 6 7 8 Fig. 3-1 LEDs on the Front Panel of the ES1652.2 Carrier Board The yellow LEDs always light up when there is a module on the carrier board. The red LEDs are not addressed by the PB1652LAMBDA.1-C. 14 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Technical Data 4 Technical Data Analog Inputs Input voltage UP Input current IP 0...5 V ±3 ma between IP and VM Analog Outputs Output voltage UN Overvoltage protection IP, IA, VM Usable with ES1652.1 and ES1652.2 0...1 V ±12 V for every channel Yes Supported Controllers CJ135STEP1 LSU4.x, LSF4.x, LSU5.1, ADV4.2, NTK ZFAS Environmental Conditions Operating temperature Relative humidity Storage temperature Relative humidity +5 C to +50 C (+41 F to +122 F) 0 to 95% (non-condensing) +5 C to +85 C (+41 F to +185 F) 0 to 95% (non-condensing) 4.1 Fulfilled Standards and Norms The PB1652LAMBDA.1-C Signal Conditioning for Lambda Sensor Simulation complies with the following standards and norms: Norm EN 61326-1 EN 61000-6-2 EN 61000-6-3 Test Electrical equipment for measurement, control and laboratory use EMC requirements Immunity (industrial environments) Emission standard (residential, commercial and light-industrial environments) Note The device confirms only with radio disturbances class A (only for industrial environment). This can cause radio disturbances in residential, commercial and light industry environment. In such a case the operator has to consider additional measures for shielding to avoid disturbances. Signal Conditioning for Lambda Sensor Simulation - User s Guide 15

Technical Data ETAS 16 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS ETAS Contact Addresses 5 ETAS Contact Addresses ETAS HQ ETAS GmbH Borsigstraße 14 Phone: +49 711 3423-0 70469 Stuttgart Fax: +49 711 3423-2106 Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php Signal Conditioning for Lambda Sensor Simulation - User s Guide 17

ETAS Contact Addresses ETAS 18 Signal Conditioning for Lambda Sensor Simulation - User s Guide

ETAS Index Index A Assembly 9 B Block diagram 6 C CE Declaration of Conformity 8 Configuration 10 Connector "IN 1..9" 13 E ETAS Contact Addresses 17 F Features 5 J Jumpers for ground reference 10 L LEDs 14 P Port "OUT 1..15" 14 Product Back 8 Relays simulation of wide-band sensors of the type "LSU5.1" 11 RoHS conformity China 8 European Union 8 S Safety instructions, basic 7 Safety instructions, labeling 7 Standards and norms 15 Switching-Type Sensor Configuration 11 T Technical data 15 U Use, correct 7 Using with a carrier board 6 W Waste Electrical and Electronic Equipment 8 WEEE take-back system 8 R Recycling 8 Signal Conditioning for Lambda Sensor Simulation - User s Guide 19

Index ETAS 20 Signal Conditioning for Lambda Sensor Simulation - User s Guide