Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Similar documents
ELT Sensor Data Sheet for S-300-3V

Intelligent Infrared CO2 Module (Model: MH-Z19)

ELT Sensor Data Sheet for C2H4-D3

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

Infrared Carbon Dioxide Sensor Module CM1108-Dual Beam

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14)

USERS MANUAL. Infrared Carbon Dioxide Module CM1102(Dual Beam With T&RH) V1.20. Wuhan Cubic Optoelectronics Co.,Ltd

Intelligent Infrared CO2 Module (Model: MH-Z19B)

Features Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ

ZG07 CO2 Module. ZG07 series CO2 Module. User Manual

Technical Information for the CDM7160 CO2 Module

ROTRONIC HygroClip Digital Input / Output

USERS MANUAL. Infrared Carbon Dioxide Module (dual beam) For safety and alarming V1.20. Wuhan Cubic Optoelectronics Co.,Ltd

RF ISM Transparent Transceiver Module V4.0

USERS MANUAL. Infrared Carbon Dioxide Module CM1102 SERIES(Dual Beam) Wuhan Cubic Optoelectronics Co.,Ltd

Catalog

Trademarks & Copyright

Stensat Radio Beacon

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing

Amphenol Advanced Sensors. SM-UART-04L PM2.5 + PM10 Particulate Dust Sensor. Application Note. Features. Applications

The MiCS-VZ-87 is an integrated sensor board for Indoor Air Quality monitoring.

3V TRANSCEIVER 2.4GHz BAND

434 MHz. Miniature narrow band radio transceiver. Operation Guide Version 4.0 (Aug. 2017) OPERATION GUIDE CIRCUIT DESIGN, INC.

MiCo SnP HT-01D HT-01D. Humidity & Temperature Sensor Module. User s Manual. MiCo SnP. 1/16

Embedded Radio Data Transceiver SV611

Catalogue 1. Brief Description Product feature Typ. Circuit Block Diagram...

Low Power with Long Range RF Module DATASHEET Description

TCS230 Color Sensor Module User s Guide

CoolEx User Manual 2008 XDIMAX LTD. Revision 1.0

Model : KY202M. Module Features. Heart Rate Variability Processing Module

Catalogue

AT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications

IS31FL CHANNEL FUN LED DRIVER July 2015

User manual. Inclinometer with Analog-RS232-Interface IK360

PREMIER PLATINUM INFRARED GAS SENSOR

Stensat Transmitter Module

RF7129 Ultra-low power Tranceiver module V2.0

Installation procedure Ground loop reader: LBS type R12 / RS232 type 5C

I-7088, I-7088D, M-7088 and M-7088D User Manual

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

um-pwm1 Pulse-width Modulation Servo Coprocessor Datasheet Release V100 Introduction Features Applications

AR1000 DATASHEET v0.1

Technical data sheet TDS0037

A Wireless Mesh IoT sensor system FEATURES DESCRIPTION. Vicotee Njord series Nodes

Product Information Using the SENT Communications Output Protocol with A1341 and A1343 Devices

DS4000 Digitally Controlled TCXO

Parameter Value Unit Notes

BV4112. Serial Micro stepping Motor Controller. Product specification. Dec V0.a. ByVac Page 1 of 18

USART Digital Compass Manual

3-Channel Fun LED Driver

FLD00042 I 2 C Digital Ambient Light Sensor

ASCII Programmer s Guide

Application Note AN 157: Arduino UART Interface to TelAire T6613 CO2 Sensor

IS31FL3209 IS31FL CHANNELS LED DRIVER; 1/24 DC SCALING WHITE BALANCE. December 2017

DRF5150S Wireless Sensor Transmitter Module V1.30

V OUT0 OUT DC-DC CONVERTER FB

Infrared Carbon Dioxide Sensor Module CM1106-Single Beam

Infrared Carbon Dioxide Gas Module ( single beam )

DRF7020D13 13dBm ISM RF Transceiver Module

IS31FL3190 IS31FL CHANNEL FUN LED DRIVER. Preliminary Information November 2015

Analog (4~20mA) & Digital (TTL) Transmitter Boards

CO2 Engine - ICB Sensor module for bio applications

Catalog

Integrated IR Application Note 1

Two-/Four-Channel, I 2 C, 7-Bit Sink/Source Current DAC

TRANSCEIVER FSK. Version: 434 MHz Band / 868 MHZ Band / Code: / A

XYO Series Optical oxygen sensors

Dual, 8-Bit, Low-Power, 2-Wire, Serial Voltage-Output DAC

A RF44 UART TTL modules

CDR-915 Data Radio Module INTEGRATOR S GUIDE

U2C-1SP4T-63H. Typical Applications

2W UHF MHz Radio Transceiver

Infrared Carbon Dioxide Sensor Module CM1106-Single Beam

Copley ASCII Interface Programmer s Guide

INTRODUCTION Laser Particle Sensor Module PM2007

Select datum Page backward in. parameter list

Please keep the following using conditions certainly

DRF4432D20 20dBm ISM RF Transceiver Module V1.21

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E

3V DUAL MODE TRANSCEIVER 434 MHz BAND Product Code:

AC / DC Sensing Current Module with Digital Data output

Temperature Sensor and System Monitor in a 10-Pin µmax

MX200 Sensor Controller Manual

RF1276 Long Distance Transceiver module V2.0

Serial Servo Controller

SenseAir S8 Miniature infrared CO 2 sensor module

USER MANUAL. Laser Particle Sensor Module PM fan series. Wuhan Cubic Optoelectronics Co.,Ltd. Ver.:

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

+Denotes lead-free package. *EP = Exposed paddle. V CC GND AGND AV CC GND I 2 C INTERFACE. -35dB TO +25dB GAIN AUDIO SOURCE AUDIO AMPLIFIER DS4420

IS31FL3236A 36-CHANNEL LED DRIVER; SELECTABLE PWM FREQUENCY IS31FL3236A. February 2018

Two-/Four-Channel, I 2 C, 7-Bit Sink/Source Current DAC

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14)

Catalogue

RF1212 RF1212 Ultra-low Power ISM Transceiver Module V2.0

DRF7020D20 20dBm ISM RF Transceiver Module V1.31

T5340, T5341, T5440, T5441 T6340, T6341, T6440, T6441

The MiCS-VZ-87 is an integrated sensor board for Indoor Air Quality monitoring.

E31-TTL-500 Datasheet V Feature E31-TTL-500

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

CLEANING. <7.5mA (streaming 1 sample per second), <20mA Peak mbar ppo₂ 0-25% O₂ (LOX-02) Indication Only / 0.1 C

Transcription:

Carbon Dioxide (Tiny CO2) Gas Sensor Rev. 1.2 TG400 User Manual

The TG400 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors having a different way. This sensor has been developed with standard gas and is efficiently calibrated using our state of the art gas sensor calibration technology. Furthermore, this sensor comes with Serial Communication (UART) and Analog Output. So, CO2 density can be checked using these inter faces easily. Features NDIR Gas Sensor High Precision Long Life Span, 5 years Compact Size, 32 x 19 mm RoHS Compliance Model : TG400 Interfaces UART, 38400 Baud Rate PWM Output Analog Output 1

Specifications Table 1. Electrical Specifications Parameter Symbol Min Typ. Max Unit Notes Regulated DC Power Supply is used, Test Condition V DD = 5 V Power Supply V DD 4.9 5 5.1 V Current Consumption I DD 12-21 ma ready state I DD 100-210 ma while gas measurement * The noise on power supply may cause incorrect measurement. Table 2. Sensor Specifications Parameter Symbol Min Typ. Max Unit Notes Measuring Range 0-5k ppm Accuracy ±5% ±30ppm Reading Value Detection Limit - 10 - ppm ( Resolution @ 0ppm region) Response Time t 1/e - - 18 sec t 90 - - 30 sec Operating Temperature T O 0-50 Operating Humidity H 0-95 %,RH Non Condensing Storage Temperature T S -30-70 Storage Humidity H 0-95 %,RH Non Condensing 2

Table 3. UART Interface Specifications Parameter Symbol Min Typ. Max Unit Notes Recommended Request Time T UR 0.5 1 - sec Transmitted Time T UT - 2 - sec Acceptable TTL Signal High Level V HU 2.31 3.3 5.25 V TXD, RXD Acceptable TTL Signal Low Level V LU - - 0.99 V TXD, RXD Table 4. Analog Output Specifications Parameter Symbol Min Typ. Max Unit Notes Analog Output Range V A 0-2500 mv Conversion Time T V - 2 - sec * The range of analog output depend on maximum value of measured ppm. 3

UART Interface This sensor comes with a serial interface for user to read ppm values. Also, several commands are supported. To use UART interface, refer to serial communication configuration in Table 5. Table 5. Serial Communication Configuration Baud Rate Stop Bits Parity Check Data Length TTL Level 38,400 bps 1 bit None 8 bits 3.3V or 5V If the communication configuration is set correctly, user will get the protocol message as mentioned below. Table 6. Protocol Format Byte 1 1 1 1 1 1 1 1 1 1 1 1 Value D6 D5 D4 D3 D2 D1 <SP> p p m <CR> <LF> Table 7. Protocol Format Explanation Value D6 ~ D1 <SP> ppm <CR> <LF> Gas density is indicated as string, Maximum length is 6 bytes. Space : 0x20 ppm : 0x70 0x70 0x6D Carriage Return : 0x0D Line Feed : 0x0A The number of <SP> between D6 and D1 will be different for different gas densities. So, user will get ppm values in ASCII format, shown below. To write commands, Follow the important points below to keep in mind while sending serial commands and refer to the examples given on pages 5. 1 This protocol format conforms to ASCII format. 2 Before send command, Enter command mode. 3 To enter in command mode, Send ATTN<CR><LF> and to exit, Send RUN<CR><LF>. 4 All commands should be delimited by<cr><lf>. 4

Getting Started with UART Commands User can communicate with sensor using PC software / terminal program or another device. Which supports serial communication on same baud rate as mentioned in serial interface specification. If user has connected their serial device correctly, they will receive string message from sensor. The message will be transmitted at intervals of about two seconds. Example RX> <SP>643<SP>ppm<CR><LF> Example 1. ASCII Code Message Example RX> 20 36 34 33 20 70 70 6D 0D 0A Example 2. HEX Code Message Entry Command Mode To use any command, sensor should be entered in command mode. To enter in command mode, user should send ATTN<CR><LF>. Otherwise, the commands will not recognized by the sensor. Example TX> ATTN<CR><LF> RX> ATTN<CR><LF> RX> <ACK> Example 3. ATTN Message Exit Command Mode To exit from the command mode, user should send RUN<CR><LF>. When user is not using serial interface, to continue with normal running mode. Example TX> RUN<CR><LF> RX> RUN<CR><LF> RX> <ACK> Example 4. RUN Message 5

I 2 C Interface This sensor communicates with the host controller, over a digital I 2 C interface. The 7-Bit base slave address is 0x31. Table 8. I 2 C Slave Address Byte Bit 7 6 5 4 3 2 1 0 Data 0 1 1 0 0 0 1 R/W * R/W : Read = 1, Write = 0 Master I 2 C device communicates with our sensor, using a command structure. The commands are listed in, Table 9. Commands, other than those documented below are undefined and should not be sent to the device. COMMAND DATA n Table 9. I 2 C Command Table 0x52 7 Byte Read PPM and state of configuration In the I 2 C sequence diagrams in the following sections, bits produced by the master and slave are color coded as shown : Master Slave Table 10. I 2 C Bit s Value Symbol START S SDA goes low while SCL high STOP P SDA goes high while SCL high Repeated START Sr SDA goes low while SCL high. It is allowable to generate a STOP bef ore the repeated start. SDA can transition to high before or after SCL goes high in preparation for generating the START READ R Read bit = 1 WRITE W Write bit = 0 ACK A Acknowledge NACK NA No acknowledge Inside sensor, there are pullup resistors on each I 2 C line. Refer to the circuit below. 6

I 2 C Sequence to perform a ppm measurement and read manual calibration state The master device should request to slave device. The slave device means this sensor. S Slave Address W A COMMAND A Bit Slave Address 0b0110001 Byte Command 0x52 * If Slaver Address = 0b0110001, They can be represented in hexadecimal as Slave Address = 0x31. Sr Slave Address R A DATA 0 A DATA 1 A DATA 2 A Configuration PPM data Byte 0x08 (fixed) Byte 0x0000 ~ 0x2710 * DATA 1 = High Byte, DATA 2 = Low Byte If DATA1 = 0b00000011, DATA2 = 0b11101000 (Binary), They can be represented in hexadecimal as DATA1 = 0x03, DATA2 = 0xE8. And they can be combined as 0x03E8, It also can be represented in decimal as 1000. So DATA1 and DATA2 are represented 1000 as ppm density. DATA3 A DATA 4 A Byte ACAL. Period 0x07 (7days) 0x1E (30days) Byte MCAL. State 0x00 (Ready) / 0x01 (Running) To know a finished manual calibration, Check a change that 0x01 0x00. The default value is 0x1E. It is unrelated to ACAL State. DATA 5 NA P Byte ACAL. State 0x00 (Disable) 0x01 (Enable) Figure 2. I 2 C Packet while reading data 7

PWM Output This sensor has PWM Output to read ppm value. To read ppm value, the PWM Output should be convert to ppm value. Refer to function 1. C ppm = 5000 T H 2ms (T H + T L 4ms) Function 1. Formula for obtaining PPM from PWM Output C ppm : CO2 level which calculated by PWM Output T H : high level output time during cycle T L : level output time during cycle Table 11. PWM Format Explanation Value CO2 Range 0 ~ 5000ppm Cycle 1004ms ±5% Cycle start high level output The middle cycle Cycle end low level output ppm : 0x70 0x70 0x6D Carriage Return : 0x0D Line Feed : 0x0A 0 PPM 10 PPM 20 PPM 4980 PPM 4990 PPM 5000 PPM Picture 1. PWM Cycle 8

Analog Output, Voltage (V) T G 4 0 0 Analog Output This sensor has analog output to read ppm value. To read ppm value, the analog voltage value should be convert to ppm value. Refer to Function 2. ppm = V Analog Output 0.0005 Function 2. Formula for obtaining PPM from Analog Output 2.5 Voltage vs. ppm value 2 1.5 1 0.5 0 0 1000 2000 3000 4000 5000 CO2 Concentration (ppm) Graph 1. Voltage to ppm Graph In case of analog output, the accuracy of ppm may be different when compared with other interface. 9

Package Dimension Dimension 1. Product Dimension Caution : Do not attempt to reassemble or give physical stress while handling. 10

Pin - TOP Table 12. Upper Pin Table 13. Lower Pin No. Pin Assigned No. Pin Assigned 1 PWM 2 SDA 3 GND 4 V DD 5-6 SCL 7 UART TXD 8 UART RXD 9 Analog Output Caution : Reserved pins should not be connected to anything. 11

Revision History Table 14. Revision History Revision Date Author 1.0 Initial release 21 July 2018 DH Jeong 1.1 Add PWM Spec. 20 August 2018 DH Jeong 1.2 Add I2C Interface. 25 October 2018 DH Jeong 12

This document contains information of products and processes in development. All information provided here is subject to change without notice. Information in this document supersedes and replaces information previously supplied in any prior versions of this document. We do not guarantee the performance of this device in case of disassembling, operating without complying with instructions in this document. Contact your TRUEYES representative to obtain the latest forecast, schedule and specifications. Or It may be obtained by calling +82-2-2083-2377~8 or by visiting http://www.trueyes.co.kr Copyright 2018 TRUEYES Incorporated. All rights reserved.