ECE 203 ELECTRIC CIRCUITS AND SYSTEMS LABORATORY SPRING No labs meet this week. Course introduction & lab safety

Similar documents
ECE 303 ELECTRONICS LABORATORY SPRING No labs meet this week. Course introduction & lab safety

Lab 4: Analysis of the Stereo Amplifier

EE 233 Circuit Theory Lab 3: First-Order Filters

ECE159H1S University of Toronto 2014 EXPERIMENT #2 OP AMP CIRCUITS AND WAVEFORMS ECE159H1S

ECE ECE285. Electric Circuit Analysis I. Spring Nathalia Peixoto. Rev.2.0: Rev Electric Circuits I

Experiment A8 Electronics III Procedure

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

10: AMPLIFIERS. Circuit Connections in the Laboratory. Op-Amp. I. Introduction

Basic operational amplifier circuits In this lab exercise, we look at a variety of op-amp circuits. Note that this is a two-period lab.

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Hands-On Introduction to EE Lab Skills Laboratory No. 2 BJT, Op Amps IAP 2008

ECE 404 e-notes...copyright 2008 by Gregory M. Wierzba. All rights reserved...fall 2008.

University of Utah Electrical Engineering Department ECE 2100 Experiment No. 2 Linear Operational Amplifier Circuits II

Performance-based assessments for AC circuit competencies

Experiment A8 Electronics III Procedure

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

11. Audio Amp. LM386 Low Power Amplifier:

Fall 2009 ElEn 256 Analog and Digital Signal Processing

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

Introductory Electronics for Scientists and Engineers

Week 8 AM Modulation and the AM Receiver

transformer rectifiers

Laboratory Exercises for Analog Circuits and Electronics as Hardware Homework with Student Laptop Computer Instrumentation

Homework Assignment 03

ESE 230 Syllabus Prof. D. L. Rode

Electronic Instrumentation ENGR-4300 Fall 2002 Project 2: Optical Communications Link

EELE 201 Circuits I. Fall 2013 (4 Credits)

Non_Inverting_Voltage_Follower -- Overview

Exercise 2: Temperature Measurement

OPERATIONAL AMPLIFIERS (OP-AMPS) II

Operational Amplifiers

ECE : Circuits and Systems II

Lab Equipment EECS 311 Fall 2009

EE431 Lab 1 Operational Amplifiers

Testing Power Sources for Stability

PHYS 536 The Golden Rules of Op Amps. Characteristics of an Ideal Op Amp

Introduction to basic laboratory instruments

Lab 6: Instrumentation Amplifier

Exercise 2: FM Detection With a PLL

EE 241 Experiment #4: USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS, Part III 1

DEPARTMENT OF PHYSICS PHYS*2040 W'09. Fundamental Electronics and Sensors. Lecturer: Dr. Ralf Gellert MacN 450 Ext

UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT

For the filter shown (suitable for bandpass audio use) with bandwidth B and center frequency f, and gain A:

Performance-based assessments for AC circuit competencies

55:041 Electronic Circuits The University of Iowa Fall Exam 3. Question 1 Unless stated otherwise, each question below is 1 point.

Rowan University Freshman Clinic I Lab Project 2 The Operational Amplifier (Op Amp)

Laboratory Project 1: Design of a Myogram Circuit

Sampling and Reconstruction

ME 365 EXPERIMENT 7 SIGNAL CONDITIONING AND LOADING

MODEL 3 MONO AMPLIFIER OWNER S MANUAL

ELEC 351L Electronics II Laboratory Spring 2014

Operational Amplifiers: Part II

DISCRETE DIFFERENTIAL AMPLIFIER

An input resistor suppresses noise and stray pickup developed across the high input impedance of the op amp.

Pre-Lab. Introduction

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Operational Amplifiers

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

Experiment 1: Instrument Familiarization (8/28/06)

Laboratory Project 4: Frequency Response and Filters

Syllabus for ENGR065-01: Circuit Theory

Exercise 1: Series RLC Circuits

Learning Objectives:

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

ECE 480: SENIOR DESIGN LABORATORY

Başkent University Department of Electrical and Electronics Engineering EEM 311 Electronics II Experiment 8 OPERATIONAL AMPLIFIERS

CHARACTERIZATION OF OP-AMP

Experiment 1: Instrument Familiarization

The measurement of loop gain in feedback seismometers Brett M. Nordgren April 9, 1999 Rev.

LT Spice Getting Started Very Quickly. First Get the Latest Software!

Introduction to basic laboratory instruments

ESE 150 Lab 04: The Discrete Fourier Transform (DFT)

Amplitude Modulation Methods and Circuits

Instructions for the final examination:

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 3157 Electrical Engineering Design II Fall 2013

CI-22. BASIC ELECTRONIC EXPERIMENTS with computer interface. Experiments PC1-PC8. Sample Controls Display. Instruction Manual

Lesson number one. Operational Amplifier Basics

Chapter 9: Operational Amplifiers

Operational Amplifiers

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

6.101 Introductory Analog Electronics Laboratory

Lab 0: Introduction to basic laboratory instruments. Revised by Dan Hoang & Tai-Chang Chen 03/30/2009

When you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp

EE320L Electronics I. Laboratory. Laboratory Exercise #2. Basic Op-Amp Circuits. Angsuman Roy. Department of Electrical and Computer Engineering

ELEG 205 Analog Circuits Laboratory Manual Fall 2017

Infrared Communications Lab

Design Document. Analog PWM Amplifier. Reference: DD00004

Function Generator Using Op Amp Ic 741 Theory

AME140 Lab #2 INTRODUCTION TO ELECTRONIC TEST EQUIPMENT AND BASIC ELECTRONICS MEASUREMENTS

Variable Gm Calibration Procedure

ECE Lab #4 OpAmp Circuits with Negative Feedback and Positive Feedback

Electronics for Scientists V and G (Spring 2007)

Operational amplifiers

WELCOME TO PHYC 307L Junior Lab II

15: AUDIO AMPLIFIER I. INTRODUCTION

Source Transformation

Laboratory experiments and reports

EUA6210 Output Capacitor-less 67mW Stereo Headphone Amplifier

Matrix Multimedia Limited Tel Fax

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

Transcription:

ECE 203 ELECTRIC CIRCUITS AND SYSTEMS LABORATORY SPRING 2019 Week of Jan. 7 Jan. 14 Jan. 21 Jan. 28 Feb. 4 Feb. 11 Feb. 18 Feb. 25 Mar. 4 Mar. 11 Mar. 18 Mar. 25 Apr. 1 Apr. 8 Apr. 15 Topic No labs meet this week Course introduction & lab safety No labs meet this week Lab I: Introduction to the Oscilloscope, Function Generator and Digital Multimeter * Lab II: Thevenin Resistance Lab III: Wheatstone Bridge Applications Lab IV: Inverting and Noninverting Amplifiers Lab V: Microphone Amplifier No labs meet this week Lab VI: Noise Canceling Headphones Lab VI: Noise Canceling Headphones (continued) Lab VII: Active Band-Pass Filter Lab VIII Parts List must be emailed to your instructor 1 day before your next lab meeting. Lab VIII: Room Equalizer Design Lab VIII: Room Equalizer Design (continued) Lab VII Pspice exercise due at the start of lab Bench Exam A Lab Exam will be given on Sunday April 21st in Room 1345 EB. You should bring a pencil and ruler. You will NOT be allowed to use a calculator for this exam. Apr. 22 Do lab course evaluations (worth 30 lab points) * All lab lectures are video recorded and can be found on the ECE 203 YouTube channel at: https://www.youtube.com/user/ece203msu

ECE 203 ELECTRIC CIRCUITS AND SYSTEMS LABORATORY MATERIALS: PREREQ: G.M. Wierzba, ECE 203 Lab Manual and e-notes, Spring 2019 Edition, available at: http://www.circuitlava.com/the-analog-university ECE 202 or concurrently GRADING: LAB REPORTS* 60% BENCH EXAM** Pass/Fail EXAM (S 4/21 @ 8:00-8:50 pm; Room 1345 EB) 40% * Your lab report grade consists of 60 points maximum. Your total lab report grade is multiplied by a scale factor at the end of the course such that all sections have the same average grade. ** You must pass the bench exam to pass the course. OVERVIEW: Your project consultant will also give a weekly quiz on the lab you are about to perform including the lab lecture material. This will count for 10 points of the maximum 60 points. It is very important that you are currently enrolled in ECE 202 while you are taking ECE 203. If you drop 202 you must also drop ECE 203. This lab is intended to teach measurement techniques as well as reinforcing concepts taught in ECE 201 and ECE 202. As you complete each task in lab you will be asked to record, calculate and evaluate your data. You cannot go on to the next step or circuit unless each task is completed as stated in the lab experiment. This method emphasizes accuracy over speed. Your lab report is due at the end of the period. Your project consultant will return your graded lab at the beginning of the next lab period. If you come to lab unprepared you will probably be unable to finish all of the tasks in each lab. You must read the lab thoroughly before you come to lab and review past labs for measurement procedures. POLICIES: Any copying of lab data from another group or section will result in a failing grade. If you miss more than two labs you will receive a failing grade. There are no make up labs. If you are seriously ill you must contact your project consultant before you miss lab. Since everyone in lab is trying to complete their lab report during lab you are not allowed to ask other lab groups for help. The project consultant will try to help you but you are responsible for your own work. TARDINESS: Lab needs to start on time. Your project consultant will take attendance at the start of lab. Your lab report grade will be multiplied by 0.9 if you are tardy from 1 to 10 min., by 0.85 if you are tardy from 11 to 30 min. If you are late more than 30 min you will not be allowed to enter lab.

Electrical Safety Considerations for ECE 203 Safety glasses are required. Minimally prescription glasses are ok but full wrap around glasses are preferred. If you fail to wear safety glasses or come to lab without a pair of safety glasses, you will be asked to leave. You can purchase another pair at the bookstore and return to lab but the penalty for tardiness described on the previous page will apply. The equipment used in ECE 203 Lab is primarily low voltage. There is no danger associated with this equipment when used as instructed. Care should always be taken not to touch the prongs of an electrical plug when inserting or removing it from an electrical outlet. In some lab experiments we are going to use polarized electrolytic capacitors. These elements must at all times have a positive voltage across their terminals with respect to an indicated polarity. Failure to do so can result in the component overheating which could cause severe burns. In such experiments warning boxes are placed in the experimental procedure and your project consultant will be required to check your wiring before you proceed. We will be cutting and stripping wires in most labs. This sometimes causes pieces of wire or plastic to fly through the air. This and the danger from capacitors is why we need safety glasses at all times. Lastly, the ECE department does not allow any food or drink in any of the experimental labs at any time. This is for your safety. Anyone who brings food or drink into lab will be asked to leave the food or drink in the hallway outside of lab. If the student refuses they will receive a lab grade of zero for that lab.

EXPERIMENT DETAILS 1. TITLE: Lab I - Introduction to the Oscilloscope, Function Generator and Digital Multimeter PURPOSE: The oscilloscope, function generator and digital multimeter are the basic tools in the measurement and testing of circuits. This lab introduces the first time operation of these instruments. 1. the resistor color code; 2. accuracy of components and the digital multimeter. 1. voltage amplitude and time measurement with an oscilloscope; 2. measurement of resistors; 3. measurement of resistance using a 4-wire probe 2. TITLE: Lab II - Thevenin Resistance PURPOSE: This lab looks at techniques for measuring a Thevenin resistance. It also introduces the use of a Proto-Board for the quick assembly of a circuit without the need to solder wires. 1. accuracy of the Infiniium; 2. measuring source resistance in linear circuits; 3. poles and throws of switches; 4. battery performance and characterization; 5. microphone characterization. 1. using the Infiniium s Toolbar to measure peak-to-peak voltages; 2. re-programming the function generator s calibration for High Impedance loads; 3. measuring DC voltage with a digital multimeter. 3. TITLE: Lab III - Wheatstone Bridge Applications PURPOSE: The Wheatstone Bridge has a very unique cancellation property. This lab looks at some of the properties of the Wheatstone Bridge and one application in the use of a compensated scope probe. 1. Wheatstone Bridge with resistive and reactive components; 2. the use of a balanced bridge to compensate for the stray capacitance of a measuring cable and the equivalent impedance of the oscilloscope; 3. capacitor coding. 1. use of an LCR meter to measure resistance and capacitance; 2. measurement of resistance and capacitance with a Wheatstone Bridge; 3. a procedure for compensating an oscilloscope probe.

4. TITLE: Lab IV - Inverting and Noninverting Amplifiers PURPOSE: The operational amplifier is a basic building block used in many electronic circuits. 1. accuracy of components and instruments; 2. the properties of the ideal operational amplifier; 3. inverting and noninverting amplification. 1. the measurement of true RMS voltage using a digital multimeter; 2. the use of the dual trace feature of an oscilloscope for measuring gain and phase of an amplifier. 5. TITLE: Lab V - Microphone Amplifier PURPOSE: Long wires in electronic circuits cause problems. In power supply connections they can cause oscillations on the wires to our integrated circuits. In microphones they pick up unwanted signals that also get amplified. We will look how to address these problems in this lab. 1. differential amplification; 2. power supply stability; 3. common-mode noise cancellation; 4. power boosting stage for an op-amp. 1. measuring RMS voltage with the oscilloscope; 2. one shot triggering. 6. TITLE: Lab VI - Noise Canceling / Eavesdropping Headphones PURPOSE: The popularity of very small portable music players is evident as you walk around campus. A real problem and danger is that the listener may attempt to cancel background noise by increasing the volume of the music. Besides making the user less aware of their surrounding, high sound levels over time can damage hearing. The nature of the problem is that your ear is picking up two sources of sound, the music and the background noise. To cancel the background noise, all we would need to do is to sense it and create the same amplitude but the opposite sign. This would mean adding a microphone to each of our headphones. By adding the noise with an opposite sign to the music from our player, we can let our ear drum add these two sounds to the background noise. The net result ideally is a cancellation of the background noise but not the music. In this lab, you will build a circuit to cancel background noise without increasing the volume of the music. We will investigate which types of background noise we can cancel and we will modify the circuitry to turn the noise canceling headphones into eavesdropping headphones.

1. bandwidth limiting to reduce noise; 2. using low noise op-amps to reduce noise; 3. using ganged pots to vary two gains simultaneously; 4. using a double-pole-double-pole (DPDT) switch to change the noise canceling headphones into eavesdropping headphones; 5. dispelling myths about noise canceling headphones through testing. 7. TITLE: Lab VII - Active Band-Pass Filter PURPOSE: Active filters are used extensively in audio preamplifier circuits and test instruments. Active filters consist of resistors, capacitors and op-amps and can realize filter functions similar to that of circuits using resistors, capacitors and inductors. 1. multiple loop feedback filters; 2. developing a design procedure for component selection; 3. using a Fourier series to model a periodic wave form; 4. the effects of capacitor quality factor on filter response. 1. using the x-y feature of the scope to display a Lissajous pattern for tuning; 2. measuring the quality factor of a capacitor using an LCR meter. 8. TITLE: Lab VIII - Room Equalizer Design PURPOSE: Furniture, drapes, walls and rugs cause amplitude and phase distortion when playing music in a confined space. Some tones are suppressed and some tones are enhanced by the room acoustics. One way to compensate for this is to amplify or attenuate the frequencies that are affected, respectively. This is done by dividing up the audio band (20 Hz to 20 khz) into smaller bands which can be amplified, attenuated or just passed. We will do this with three band-pass active filters. By summing the results we can then put the audio band back together with the compensated music and play this through a power amplifier. In lab, we have one high quality speaker per lab bench so to play a stereo source of sound we need to add the two channels creating a monaural source of sound. 1. designing a stereo-to-monaural converter; 2. determining design constraints and component selection for the band-pass filters of the equalizer; 3. designing a variable summer.