Ideal for testing taping machines and sorters

Similar documents
Ideal for testing taping machines and sorters. C METER C HiTESTER 3504

Ideal for testing taping machines and sorters C METER C HiTESTER / / Electronic measuring instruments

BATTERY HiTESTER BT3563, BT3562, 3561

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

A New Series of LCR Meters to Meet Your Applications

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

3535 LCR HiTESTER Components measuring instruments

IMPEDANCE ANALYZER IM3570

High-Speed Resistance Meters Optimized for Automated Systems. RESISTANCE HiTESTER RM3542, RM Measure in as little as 0.

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

DIGITAL HiTESTER 3237, 3238, 3239

CHEMICAL IMPEDANCE ANALYZER IM3590

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

High-precision portable RESISTANCE METER

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

High speed Stability. DC, 4 Hz to 8 MHz. Measurement frequency LCR METER IM3536

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.

RESISTANCE HiTESTER 3541

High-speed DMM. DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced)

World-Class Accuracy & Measurement Range (40 Conventional Models)

3541 RESISTANCE HiTESTER

From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications LCR METER IM3523, IM3533

CATALOG including...

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

Ω and 0.1 fa Current Resolution DIGITAL SUPER MEGOHMMETER DSM-8104, DSM Fast, Highly Accurate Measurement. DSM-8104 (Single-Channel)

An Evolution in Stable Measurements

INSULATION TESTER SERIES

99 Washington Street Melrose, MA Phone Toll Free Visit us at

POWER HiTESTER 3331, 3332

LCR METER IM3523/IM3533/IM


Ohmmeter Replacement Guide

AC/DC CLAMP METER CM4371, CM4373

CATALOGO STRUMENTI Ricerca & Sviluppo

PRECISION DC VOLTMETER DM7275, DM ½ Digit. Precision DC Voltmeter. 9 ppm DC Voltmeter for R&D to Production Lines

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

3331, 3332 POWER HiTESTER

MEASURING INSTRUMENT. Capacitance Leakage Current / IR Meter Model IR Features.

AC/DC CLAMP METER CM4370 series

AC/DC CLAMP METER CM4370 series

High-accuracy bench-top meter ideal for production lines RESISTANCE METER RM3545, RM3544

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Standard models. Introducing a line of field-optimized instruments that can be chosen based on the application at hand

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

Battery Analyzers BA6010 Series

Ω and 0.1 fa Current Resolution DIGITAL, ULTRA-HIGH RESISTANCE/ ULTRA-LOW CURRENT METERS. Fast, Highly Accurate Measurement DSM-8104, DSM-8542

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

DB230 Capacitor Tester

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

Wide-band Models from DC to 100 MHz

Featuring super-high accuracy and multi-channel capabilities (20 channels with 4-terminal measurement)

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

Ohmmeter Replacement Guide

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis

Wide-band Models from DC to 100 MHz

Wide Spectrum Power Meter for Comprehensive Device Assessment

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

Fluke 83V and 87V Digital Multimeters

DIGITAL / ANALOG HiTESTER SERIES

DIGITAL / ANALOG HiTESTER SERIES

Model 6517B Electrometer / High Resistance Meter Specifications

General Specifications

CATALOGO STRUMENTI Ricerca & Sviluppo

DC Resistance Meters 2840 Series

DIGITAL MULTIMETER DT4200 Series

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

Agilent 4285A Precision LCR Meter

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

79/26 Series III Multimeter

Data sheet IDM 99III Digital Multimeter

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER DSM-8104, DSM-8542

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

CLAMP ON HiTESTER SERIES

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Fluke 8845A/8846A Digital Multimeters Extended Specifications

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

Fast 10-ms Sampling Up to 600 Channels Data Logging. MEMORY HiLOGGER 8423

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

2300 REMOTE MEASUREMENT SYSTEM Data Logger

DIGITAL STORAGE OSCILLOSCOPES

Resistance Meters for Production Lines and MRO. Easy to use with high-accuracy RESISTANCE METER RM3544, RM3548

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

U1730C Series Handheld LCR Meters

HP 34401A Specifications 8

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

PRECISION COMPONENT ANALYZER 6430B / 6440B

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

Bipolar Output Working Standard

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Agilent E4981A Capacitance Meter 120 Hz/ 1 khz/ 1 MHz. Data Sheet

Transcription:

METER 506-10 HiTESTER 504 For Low apacitance METER 506-10 Measures at 1 khz and 1 MHz For High apacitance MLs HiTESTERs 504-60, 504-50 and 504-40 Measures at 120 Hz and 1 khz Ideal for testing taping machines and sorters METER 506-10 High-speed measurement with an analog measurement time of 0.6 ms (1 MHz) Improved noise resistance and dramatically increased repeatability for measurement of minuscule capacitance values Stable measurement of low-capacitance capacitors at 1 MHz HiTESTER 504-60/504-50/504-40 onstant-voltage measurement with an analog measurement time of 1 ms (1 khz); ideal for measurement of high-capacitance MLs onstant-voltage measurement of high capacitance values up to 1.45 mf (120 Hz, 500 mv) Model 504-60 provides four-terminal contact checking.

2 METER Analog measurement times as low as 0.6 ms for improved capacitor productivity ommon Features of Models 506-10, 504-60, 504-50 and 504-40 -Meter measurement frequencies comply with JIS 5101-1 Measurement Frequency [Hz] apacitor Type Range Indicates recommended frequency Non-Electrolytic 1000 pf 1000 pf < 10 μf 10 μf < Electrolytic - 120 1k 1M Supporting Models 506-10 504-60 504-50 504-40 120 511-50 (for ref.) BIN function measurement values can be classified into up to 14 *1 ranks for easy sorting. *1 Models 506-10 support up to 1 ranks. omparator function Upper and lower limits can be specified for first () and second () parameters. Evaluation results can be indicated by beeper, LE indicators and external output, with the setting values always displayed. Memory function Measurement data is stored in the instrument and can be downloaded via GP-IB or RS-22. 506-10... 1,000 measurements 504-60, 504-50 and 504-40... 2,000 measurements Intuitive operation with LE indicators Simply select the desired operation on the front panel. The current measurement configuration settings are indicated by LEs so you can check your settings at a glance. Trigger-synchronous output The measurement signal is applied to the test sample only when a measurement trigger is applied. Because large current does not flow when making and breaking contact with the sample, contact point wear is minimized. Stores 99 *2 measurement configurations Store up to 99 sets of measurement configuration settings for quick recall when switching test sample types on lines with many repeating measurements. Any measurement configuration can be recalled by EXT I/O. *2 Models 506-10 store up to 70 measurement configurations. ontact-checking functions included etect contact errors during measurement. Improve yield rates by separately managing samples that exhibit contact errors.

High-speed measurements as fast as 1.5 ms (0.6 ms for analog measurements) High-speed testing such as with taping machines is supported by the 1.5 ms minimum measurement time (at FAST, 1M Hz measurements, 506-10). Select from FAST, NORMAL and SLOW measurement speeds. 506-10 Measurement Frequency 1 khz 1 MHz Measurement Speed Output Signal FAST NORMAL SLOW INEX 1.1 ms 4.1 ms 1. ms EOM 2 ms 5 ms 14 ms INEX 0.6 ms 4.1 ms 1. ms EOM 1.5 ms 5 ms 14 ms 504-60, 504-5 0, 504-40 Measurement Speed Measurement Frequency 120 Hz 1 khz Output Signal FAST NORMAL SLOW INEX 8. ms. ms 1. ms EOM 10 ms 7.5 ms 146 ms INEX 1 ms 4 ms 24 ms EOM 2 ms 5.5 ms 29.5 ms Easy integration into automatic testing equipment EXT I/O RS-22 GP-IB Voltage selector Voltage selector EXT I/O GP-IB * RS-22 * Model 504-40 does not include a GP-IB interface. METER 506-10 HiTESTER 504-60, 504-50, 504-40 EXT I/O Triggering and loading of measurement conditions can be controlled externally. apable of external output of comparator results, BIN measurement results, and end-of-measurement signals, these meters support full interfacing with automated devices. EXT I/O Timing hart TRIG 1 huck 1 End-of-Measurement 2 Transport 2 huck Inputs External power input (+5 to 24 V, may be supplied from external device) External trigger signal Panel number (Measurement configuration) selection Panel-number-valid signal alibration EXT I/O Features Outputs Internal power output (+5 V) omparator result output (first and second parameters, and ANed results) Bin measurement judgment output Analog End-of-Measurement signal End-of-Measurement signal Error message output RS-22 and GP-IB interface *4 Except for turning the instrument's power on and off, all meter functions can be controlled from a computer. This facilitates efficient data handling when controlling or processing data in batches on a computer or when setting instrument processing or measurement conditions. *4 GP-IB is available on Model 504-60, 504-50, 504-40. INEX RS-22 interface Transfer method: Start-stop transfer ata length: 8 bits Stop bit: 1 bit GP-IB interface 0.6 ms* 1 Analog Measurement 1.5 ms* 1 Analog End-of-Measurement EOM 1 Measuring 1 End-of-Measurement HI, IN, LO, BIN 0 Judgment 1 Judgment * Measurement Speed: FAST used for example. Applicable for 1 MHz measurements. Transfer speed: 9600, 19200 bps Parity: None elimiter: R+LF, R IEEE-488-2 1987 common commands (mandatory) can be used onformance standard: IEEE-488.1 1987 Reference standard: IEEE-488.2 1987

-value repeatability during 1 pf measurement 4 METER 506-10 Measure low-magnitude capacitors with high accuracy Measurement parameters and frequency ranges Measurement Frequencies Range of Measurements (, ) 120 Hz 1 khz 1 MHz : 0.000 ff to 15.0000 μf 506-10 : 0.00001 to 1.99999 N/A Features of Models 506-10 METER Faster measurement and improved repeatability ompared to the previous model (506), the 506-10 delivers higher measurement speeds in FAST mode and an improvement by a factor of approximately 7 in repeatability for measurement of minuscule capacitance values in high-noise environments. These characteristics make the instrument ideal for embedded measurement in taping machines, sorters, and other automatic systems. Enhanced absolute accuracy A self-calibration function minimizes variations in measurement values due to changes in ambient temperature. In addition, the cable-length-compensation function minimizes measurement errors when the measurement cable is extended from 1 to 2 meters (using 1.5-2V cable). 1.6% 1.4% 1.2% 1.0% 0.8% 0.6% 0.4% 0.2% 0.0% Power supply noise of 0 V Power supply noise of 1,500 V Improvement by a factor of about 7 in repeatability in highnoise environments 0.025% 0.016% 1.4% Faster measurement (Analog measurement time, FAST mode) 0.21% 0.6ms 1.1ms 506-10 (INEX=0.6ms) 506 (INEX=1.1ms) Repeatability in high-noise environments (1 MHz, 1 V, FAST mode) Enhanced contact-checking function ontact errors while measuring can be detected by the hatter etection function, Low- Reject function, urrent etection ircuit Monitoring function and the Applied Voltage Value Monitoring function. Yield rates are improved by judging measurement-object contact errors as ERR instead of FAIL. Extremely low capacitance judged as Low (ERR) hatter Faulty ontact hatter hatter etection Function Unstable Voltage and urrent While Measuring ERR Pass / Fail Judgment ontact ondition Normal ontact hatter etection Function Stable Voltage and urrent While Measuring Pass / Fail Judgment hatter Monitoring Interval INEX Analog Measurement Low- Reject Function hatter etection Function

5 Specifications Measured parameters (apacitance), (dissipation factor tan ), Q (1/tan ) Measurement frequencies Measurement signal level Range of measurable values 1 khz and 1 MHz Accuracy: ±0.01% or better Frequency shift: 1 MHz ±1%, ±2% Open-circuit terminal voltage: 500 mv or 1 V Signal level accuracy: ±10% ±5 mv Output resistance: Approx. 1Ω (@1 khz in 2.2 μf and higher ranges), approx. 20 Ω (in ranges other than the above) : 0.000 ff to 15.0000 μf : 0.00001 to 1.99999 Q: 0.0 to 19999.9 Equivalent circuit mode Series-Parallel Equivalent ircuit mode (Auto/Manual) Measurement time Measurement speed Averaging function 1 to 256 Low- reject function hatter detection function urrent detection circuit monitoring function Applied voltage value monitoring function Trigger function Trigger delay Memory function Representative value: 1.5 ms (FAST) (Actual measurement time depends on measurement configuration settings) FAST, NORMAL and SLOW Bad ontact etection (open circuit between terminals) Bad ontact etection (chatter) A measurement signal fault is detected when external noise causes measurement levels to be out of tolerance for the measurement range. An error is detected when voltage monitored across a test sample is outside of the judgment standard. Internal and external triggers can be enabled 0 to 9.999 s Up to 1,000 measurement values can be stored in the instrument (ownloadable by GP-IB and RS-22) ompensation Trigger-synchronous output function Key-lock function BIN measurement omparator Panel save and load Audible beeper Interface Printer function isplay device METER 506-10 Open- and short-circuit compensation, load and cable length compensation, and self calibration Functions to inhibit measurement voltage except while actually measuring Settings can be made and cancelled by front panel keys : 1 ranks, -NG, OUT OF BINS, Absolute value setting, setting, % setting : HI, IN, LO; (Q): HI, IN, LO Absolute value setting, setting, % setting 70 setting configurations can be stored Load method: key operation or external I/O Setting the buzzer for comparator judgment results (IN or NG) to ON or OFF is possible RS-22, GP-IB and EXT I/O (included as standard) Measurement values can be printed (requires Model 9442 or 9444 cable) LEs (on/off) Operating temperature 0 to 40, 80% rh or less (non-condensating) and humidity Storage temperature and -10 to 55, 80% rh or less (non-condensating) humidity Operating environment Indoors, to 2000 m ASL Power supply Selectable 100, 120, 220 or 240 V ±10%, 50/60 Hz Max. power consumption 40 VA Withstand voltage Power line to ground: 1.9 kv A for 15 s Backup battery life Approx. 6 years imensions Mass Applicable standards Supplied accessories Approx. 260 W 100 H 298 mm (10.24" W.94" H 11.7" ) (exc. projections) Approx. 4.8 kg (169. oz) EM: EN6126, EN61000--2, EN61000-- Safety: EN61010-1 Power ord, Spare Fuse Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 2 ±5%, 80% rh or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation, and self calibration set to Auto Measurement area : 0.001 ff to 15.0000 μf; : 0.00001 to 1.99999 Measurement accuracy Use the following equation to calculate the measurement accuracy. Measurement accuracy = basic accuracy B E [B: Measurement signal level coefficient] 1 V: 1, 500 mv: 2 [: Measurement speed coefficient] FAST: 1.5 (1k Hz), (1M Hz) NORMAL: 1.2, SLOW: 1 [: able length coefficient] (using 1.5-2V cable) 0 m: 1, 1 m: 1.5, 2 m: 2 [E: Temperature coefficient] 1+ 0.1 t- 2 t = operating temperature ( ) Basic accuracy (Accuracy guaranteed for 1 year when 0.1, Post-adjustment accuracy guaranteed for 1 year) range Parameter 100 pf 220 pf 470 pf 1 nf 2.2 nf 4.7 nf 10 nf 22 nf 47 nf 100 nf 220 nf 470 nf 1 μf 2.2 μf 4.7 μf 10 μf Accuracy 1 khz 0.12%rdg+0.2%rdg (r/x) 0.002+0.001 (r/x) 0.12%rdg+0.08%rdg (r/x) 0.0012+0.0004 (r/x) 0.12%rdg+0.04%rdg (r/x) 0.0012+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.0012+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.0012+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) range Parameter 220 ff 470 ff Accuracy 1 MHz [x : the electrical capacity of the sample / r : the electrical capacity of the measurement range] 1 pf 2.2 pf 4.7 pf 10 pf 22 pf 47 pf 100 pf 220 pf 470 pf 1 nf 0.2%rdg+1%rdg (r/x) 0.004+0.002 (r/x) 0.15%rdg+0.%rdg (r/x) 0.00+0.001 (r/x) 0.12%rdg+0.16%rdg (r/x) 0.002+0.001 (r/x) 0.12%rdg+0.08%rdg (r/x) 0.0012+0.0004 (r/x) 0.12%rdg+0.04%rdg (r/x) 0.0012+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.0012+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x) 0.12%rdg+0.02%rdg (r/x) 0.001+0.000 (r/x)

6 HiTESTER 504-60, 504-50 and 504-40 Perform high-speed, constant-voltage testing even of high-capacitance MLs Measurement parameters and frequency ranges 504-60 504-50 504-40 Range of Measurements (, ) : 0.9400 pf to 20.0000 mf : 0.00001 to 1.99999 Measurement Frequencies 120 Hz 1 khz 1 MHz N/A Functional differences between Models 504-60, 504-50 and 504-40 onstant-voltage Four-Terminal Measurement (V) Bin Interface ontact heck Function 100mV 500mV 1V Function RS-22 GP-IB EXT I/O 504-60 504-50 N/A N/A 504-40 N/A N/A N/A N/A Features of Model 504-60, 504-50 and 504-40 HiTESTERs onstant voltage measurement (V) onstant measuring voltages of 1 V, 500 mv and 100 mv *1 are provided for voltage-dependent capacitance measurements. Measurement frequency is selectable from 120 Hz or 1 khz. *1 100 mv in Model 504-60 only. ompatible with taping machine assemblies Model 504-40 provides the speed and good cost-performance suitable for taping machine systems. Specifications Measured parameters (capacitance), (dissipation factor tan ) Measurement frequencies Measurement signal level *1 100 mv in Model 504-60 only 120 Hz or 1 khz Accuracy: ±0.01% or better (1) onstant voltage mode: 100 mv *1, 500 mv and 1 V V 1V measurement ranges: up to 70 μf range (1 khz) up to 0.7 mf range (120 Hz) V100 mv *1, V 500 mv measurement ranges: up to 170 μf range (1 khz) up to 1.45 mf range (120 Hz) Signal level accuracy: ±10% ±5 mv (2) Open terminal voltage mode: 100 mv *1, 500 mv and 1 V Measurement range: Other than the above Output resistance: approx. 5Ω Signal level accuracy: ±10% ±5 mv Range of measurable : 0.9400 pf to 20.0000 mf values : 0.00001 to 1.99999 Equivalent circuit mode Series/parallel equivalent-circuit mode (Auto/Manual) Measurement time Measurement speed Trigger function Trigger delay ompensation Nominal 2 ms (1 khz, FAST) (The measurement time differs depending on the measurement frequency and measurement speed that are set.) FAST / NORMAL / SLOW Internal and external trigger sources can be selected. 0 to 9.999 s (at 0.001 s resolution) Open, Short, Load and Offset compensation, Self-calibrating Averaging function 1 to 256 Four-terminal contact-checking etects contact anomalies (open state in four-terminal function* measurements) (* 504-60 only) Low- reject function etects contact anomalies (open state in two-terminal measurements) hatter detection function etects contact bounce (chatter) Four-Terminal ontact-hecking Function The 504-60 features a 4-terminal contact checking mechanism. etection of contact errors involving all four terminals, including the POT terminal, ensures improved measured value reliability. Enhanced ontact-hecking Functions ontact errors can be detected while measuring by the Low- Reject and hatter etection functions. Yield rates are improved by judging measurement object contact errors as ERR instead of FAIL. Trigger-synchronous output function Key-lock function BIN measurement (Not available on the 504-40) Memory function omparator Panel save and load Audible beeper Interface Function to apply a measurement signal only when performing measurement. The key lock can be set and cancelled by key operation on the front panel ; 14 ranks, -NG, OUT OF BINS Absolute value setting, Δ% setting Up to 2,000 measurement values can be stored in the instrument (ownloadable by GP-IB and RS-22) : HI / IN / LO, : HI / IN / LO Absolute value setting, Δ% setting Up to 99 sets of measurement conditions can be saved. Load method: Key operation, external I/O. The beeper can be set on or off according to the comparator evaluation result ( IN or NG ) and Bin decision result. Models 504-50, 504-60: RS-22, GP-IB, EXT I/O (standard) Model 504-40: RS-22, EXT I/O (standard) Measurement values can be printed (requires Printer 9442 and Printer function optional onnection able 9444) isplay device LE Operating temperature and humidity 0 to 40, 80% rh or less (no condensation) Storage temperature and humidity -10 to 55, 80% rh or less (no condensation) Operating environment Indoors, up to 2000 m ASL Power supply A 100 V, 120 V, 220 V, or 240 V±10% (selectable), 50/60 Hz Max. power consumption 110 VA max. Withstand voltage Power line to ground, A 1.69 kv, 15 sec. Backup battery life Approx. 6 years imensions Mass Applicable standards Supplied accessories Approx. 260 (W) 100 (H) 220 () mm (10.24 W.94 H 8.66 ) (excluding protrusions) Approx..8 kg (14.0 oz) EM: EN6126, EN61000--2, EN61000-- Safety: EN61010-1 Power cord, spare fuse

7 HiTESTER 504-60, 504-50 and 504-40 Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 2 ±5%, 80% rh or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation Measurement area : 0.9400 pf to 20.0000 mf; : 0.00001 to 1.99999 Measurement accuracy Basic accuracy (Accuracy guaranteed for 6 months when 0.1, Post-adjustment accuracy guaranteed for 6 months) Use the following equation to calculate the measurement accuracy. Measurement accuracy = basic accuracy B E [B: Measurement signal level coefficient] 1 V and 500 mv: 1, 100 mv: 1.5 [: Measurement speed coefficient] FAST: 1.5 NORMAL: 1.0 (at 1k Hz, 1 V), 1.2 (except at 1k Hz, 1 V) SLOW: 1 [: able length coefficient] (using 1.5-2V cable) 0 m: 1 1 m: 1 (at 1k Hz, 1 V) 1.5 (except at 1k Hz, 1 V) [E: Temperature coefficient] 1+ 0.1 t-2 t = operating temperature ( ) Range No. range Basic accuracy *2 V opera- 120 Hz 1 khz Parameter 120 Hz 1 khz tion 1 200 pf 20 pf 2 2 nf 200 pf 20 nf 2 nf 4 200 nf 20 nf 5 2 μf 200 nf 6 20 μf 2 μf 7 200 μf 20 μf 8 0.7 mf(1v) 1.45 mf(500 mv, 100 mv) 70 μf(1v) 170 μf(500 mv, 100 mv) 9 2 mf 200 μf 10 20 mf 2 mf ±0.20%rdg.±00dgt. ±0.0120±2/L ±0.20%rdg.±60dgt. ±0.0020±2.2/L ±0.16%rdg.±20dgt. ±0.006 ±0.15%rdg.±15dgt. ±0.0020 ±0.15%rdg.±15dgt. ±0.0016 ±0.15%rdg.±15dgt. ±0.0020 ±0.25%rdg.±20dgt. ±0.005 ±1.2%rdg.±50dgt. ±0.0060 ±1.2%rdg.±50dgt. ±0.0060 ±2.5%rdg.±50dgt. ±0.0200±0.008 H [ L: apacitance of component (pf), H: apacitance of component (mf)] *2 Accuracy of range nos. 1 and 2 are not guaranteed at 100 mv measurement signal level. ±0.20%rdg.±00dgt. ±0.0120±0.25/L ±0.20%rdg.±60dgt. ±0.0020±0.265/L ±0.14%rdg.±20dgt. ±0.006 ±0.1%rdg.±15dgt. ±0.0020 ±0.1%rdg.±15dgt. ±0.0016 ±0.09%rdg.±10dgt. ±0.0016 ±0.1%rdg.±15dgt. ±0.000 ±0.7%rdg.±40dgt. ±0.0050 ±0.7%rdg.±40dgt. ±0.0050 ±2.0%rdg.±40dgt. ±0.0180±0.08 H N/A N/A LR meter for production lines and automated testing LR METER IM52 ± 0.05% accuracy with wide measurement range (R testing, 40Hz to 200kHz, 5mV to 5V, 10uA to 50mA) Non-stop testing over mixed measurement conditions such as - and ESR at 10 times the speed of previous models (compare with the model 522-50) Built-in comparator and BIN functions Rapid 2ms test time This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5-2V coaxial cable. For an RS-22 connection: A crossover cable for interconnection can be used. You can use the RS-22 ABLE 967 without hardware flow control. Single evice Solution for High Speed Testing and Frequency Sweeping IMPEANE ANALYZER IM570 Special Model with 100 mv Measurement Signal METER 506-10 100 mv special model LR measurement, R measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument High-speed testing, achieving maximum speeds of 1.5ms (1 khz) and 0.5ms (100kHz) in LR mode High-accuracy measurements, basic accuracy of Z parameter: ± 0.08% This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-22 connection: A crossover cable for interconnection can be used. You can use the RS-22 ABLE 967 without hardware flow control. 100 mv measurement signal level (500 mv measurement signal level not available) Ideal for use in applications requiring a low measurement signal level, for example diode junction capacitance measurement ontact your HIOKI distributor for more information about this special model.

Model onfigurations and Options Probes and Test Fixtures for 506-10 FOUR-TERMINAL PROBE L2000 FOUR-TERMINAL PROBE 9140-10 able length 1 m (.28 ft), to 8 MHz, able length 1 m (.28 ft), to 200 khz, impedance characteristics of 50 Ω, 4-termi- impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor nal pair configuration, measurable conductor diameter: ø0. mm (0.01 in) to 5 mm (0.20 in) diameter: ø0. mm (0.01 in) to 5 mm (0.20 in) Probes and Test Fixtures for 504-60/504-50/504-40 FOUR-TERMINAL TEST FIXTURE PROBE 9140 9261 able length 1 m (.28 ft), to 100 khz, imped- able length 1 m (.28 ft), to 8 MHz, impedance characteristics of 75 Ω, 5-terminal design, 4 ance characteristics of 75 Ω, 4-terminal design, 4 electrode terminals, measurable conductor diam- electrode terminals, measurable conductor diameter: eter: ø0. mm (0.01 in) to 5 mm (0.20 in) ø0. mm (0.01 in) to 1.5 mm (0.06 in) TEST FIXTURE 9261-10 SM TEST FIXTURE IM9100 able length 1 m (.28 ft), to 8 MHz, impedance characteristics of 50 Ω, 4-terminal Measurable range: to 8 MHz, For SM pair configuration, measurable conductor with electrodes on bottom, Measurable sample diameter: ø0. mm (0.01 in) to 1.5 mm (0.06 in) sizes: 01005 to 0402 (EIA) 0402 to 1005 (JIS), PINHER PROBE irect connection type L2001 *Ships standard with one set of IM9901 able length 70 mm (2.40 ft), to 8 MHz, SM TEST FIXTURE characteristic impedance of 50 Ω, 4-terminal pair IM9110 design, 2-terminal electrode, tip electrode spacing of 0. to approx. 6 mm (0.01 to approx. 0.24 in) Options for L2001 Replaceable contact tips ONTAT TIPS IM9901 ompatible chip sizes: 1608 to 5750 (JIS) ONTAT TIPS IM9902 ompatible chip sizes: 060 to 5750 (JIS) Measurable range: to 1 MHz, For SM with electrodes on side, Measurable sample sizes: 008004 (EIA), 0201 (JIS), Please contact Hioki for information about other sizes, irect connection type Probes and Test Fixtures for 506-10 / 504-60 / 504-50/504-40 TEST FIXTURE 9262 SM TEST FIXTURE 926 SM TEST FIXTURE 9677 SM TEST FIXTURE 9699 irect connection type, to 8 MHz, measurable conductor diameter: 0. to 2 mm (0.01 to 0.08 in) irect connection type, to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.9 in) irect connection type, Electrodes on side for SM, to 120 MHz, Test sample dimensions:.5 mm ±0.5 mm (0.14 in ±0.02 in) irect connection type, Electrodes on bottom for SM, to 120 MHz, Test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, maximum 1.5 mm (0.06 in) high For Low-Magnitude apacitors Model: METER 506 Model No. (Order ode) (Note) 506-10 Measurement frequencies: 1 khz and 1 MHz For High-Magnitude ML Model: HiTESTER 504 Model No. (Order ode) 504-60 504-50 504-40 (Note) Measurement frequencies: 120 Hz and 1 khz, constant voltage measurement at 100 mv, 500 mv and 1 V, four-terminal contact-checking function, with GP-IB, RS22 Measurement frequencies: 120 Hz and 1 khz, constant voltage measurement at 500 mv and 1 V, with GP-IB, RS22 Measurement frequencies: 120 Hz and 1 khz, constant voltage measurement at 500 mv and 1 V, no GP-IB interface, no Bin function, with RS22 interface Probe and test fixtures are not supplied with the unit. Select an optional probe and test fixture when ordering. Printer Measurement values, comparator results, and BIN measurement A AAPTER 944-01 A AAPTER 944-02 results can be printed out on the optional Printer 9442 via the (for 9442, Japan) (for 9442, EU) standard RS-22 interface. onvenient for applications that require printed data to be attached to inspection results. ONNETION ABLE REORING PAPER 1196 Printer 9442 specifications 9444 (for 9442, 25 m (984.25 ), Printing method: Thermal serial dot printer (for 9442) Paper width: 112 mm 10 rolls) Print speed: 52.5 cps PRINTER 9442 Power supply: A Adapter 944 or supplied NiMH battery (prints (The optional onnection able 000 lines after full charge using 944) 9444 and A Adapter are required imensions and weight: Approx. 160W 66.5H 170 mm to connect the Printer 9442.) (6.0 W 2.62 H 6.69 ), 580 g (20.5 oz) Interface able GP-IB ONNETION ABLE 9151-02 2 m (6.56 ft) length Note: ompany names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) SALES & TRAING O., LT. TEL +86-21-691-0090/0092 FAX +86-21-691-060 http://www.hioki.cn / E-mail: info@hioki.com.cn ISTRIBUTE BY HEAQUARTERS 81 Koizumi, Ueda, Nagano 86-1192 Japan TEL +81-268-28-0562 FAX +81-268-28-0568 http://www.hioki.com / E-mail: os-com@hioki.co.jp HIOKI USA ORPORATION TEL +1-609-409-9109 FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: hioki@hiokiusa.com HIOKI SINGAPORE PTE. LT. TEL +65-664-7677 FAX +65-664-7477 E-mail: info-sg@hioki.com.sg HIOKI KOREA O., LT. TEL +82-2-218-8847 FAX +82-2-218-60 E-mail: info-kr@hioki.co.jp HIOKI EUROPE GmbH TEL +49-617-2406 FAX +49-617-24064 E-mail: hioki@hioki.eu All information correct as of Oct., 2017. All specifications are subject to change without notice. 506-10E9-7XB Printed in Japan