Voltage and Current Waveforms Enhancement using Harmonic Filters

Similar documents
Effects of Harmonic Distortion I

Power Quality Analysis in Power System with Non Linear Load

Generator Advanced Concepts

HARMONICS CAUSES AND EFFECTS

CHAPTER 4 HARMONICS AND POWER FACTOR

Power Quality enhancement of a distribution line with DSTATCOM

Analysis of Harmonic Distortion in Non-linear Loads

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Emicon Engineering Consultants L.L.C.

High Voltage DC Transmission 2

Application of Tuned Passive Filter for Industrial Six-Pulse Rectifier with R-L Load Viralkumar A. Rana 1 Keyur Rana 2 Atul Talati 3

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Volume I Issue VI 2012 September-2012 ISSN

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

IMPORTANCE OF VSC IN HVDC

Power Upgrading of Transmission Line by Injecting DC Power in to AC Line with the help of ZIG-ZAG Transformer

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Harmonic Requirements

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Harmonic Filters and Reactors

Conventional Paper-II-2013

Effect of Harmonics on the Performance Characteristics of Three Phase Squirrel Cage Induction Motor

Harmonics Reduction in a Wind Energy Conversion System with a Permanent Magnet Synchronous Generator

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Tuningintobetter power quality

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

SHUNT ACTIVE POWER FILTER

Low Pass Harmonic Filters

Principles for Controlling Harmonics

Harmonics Elimination Using Shunt Active Filter

Performance Analysis of Passive Filter for Harmonics Due to Non-Linear Load in Power System

CHAPTER 1 INTRODUCTION

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

STUDY OF THE EFFECTS OF HARMONICS IN THE DESIGN OF TRANSMISSION NETWORK SHUNT COMPENSATORS: NETWORK SIMULATION AND ANALYSIS METHODS

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

22.0 Harmonics in Industrial Power Systems

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

UNDERSTANDING SUB-HARMONICS

(2) New Standard IEEE P (3) Core : (4) Windings :

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Long lasting transients in power filter circuits

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Thyristorised Automatic Power Factor

International Journal of Electrical Engineering and Technology (IJEET), ISSN (Print), INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING &

Power Transmission of AC-DC Supply in a Single Composite Conductor

Introduction to Rectifiers and their Performance Parameters

Alternators Reactance for Nonlinear Loads

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

Design and Simulation of Passive Filter

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Fundamentals of Power Electronics

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

Study of Power Factor Correction in Single Phase AC-DC Converter

Outcomes of Harmonics & Its Reduction Techniques: A Comprehensive Review

Multilevel Inverter Based Statcom For Power System Load Balancing System

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

G. KOBET, I. GRANT, G. GOZA Tennessee Valley Authority USA. R. GIRGIS, M. ESPINDOLA ABB Corporation USA SUMMARY

Voltage Source Converter Modelling

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Transients under energizing multiple power filter circuits

Design of Three Phase PWM Voltage Source Inverter for Induction Heater

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

The Impact of Connecting Distributed Generation to the Distribution System E. V. Mgaya, Z. Müller

GATE: Electronics MCQs (Practice Test 1 of 13)

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

New HVDC Interaction between AC networks and HVDC Shunt Reactors on Jeju Converter Stations

The unified power quality conditioner: the integration of series and shunt-active filters

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

Reducing Total Harmonic Distortion with Variable Frequency Drives

Chapter 4. Hybrid series active filter. 4.1 Introduction

Harmonics Reduction using 4-Leg Shunt Active Power Filters

VARIABLE FREQUENCY DRIVE

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Analysis of Indirect Temperature-Rise Tests of Induction Machines Using Time Stepping Finite Element Method

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Understanding the Design and Control of VSC-Based HVDC System with Shunt Passive Filters

Understanding Input Harmonics and Techniques to Mitigate Them

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

System Protection and Control Subcommittee

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Power Factor. Power Factor Correction.

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Transcription:

Voltage and Current Waveforms Enhancement using Harmonic Filters Rajeb Ibsaim rabsaim@yahoo.com, Azzawia University, Libya Amer Daeri ibnjubair1@yahoo.co.uk Azzawia University, Libya Abstract The demand on reactive power in transmission and distribution systems is remarkably increasing especially in areas where extensive utilization of electric furnaces, induction machines, computers, thyristors and florescent lighting fixtures. These have resulted to unbalance in system operation and malfunctions causing distortions to both, voltage and current sinusoidal waveforms by what so known "The Harmonicas". In this paper, power system components with inductive loads were modeled using computer to monitor the shape of the voltage/current waveforms in the absence of any means of filters. An appropriate filter was designed by the model to limit the distortions and obtain better sine waveforms of the voltage/current variables. The paper outlined the essential design of appropriate filters to dissipate these harmonics to the ground before entering the appliances and cause malfunctions or damage to its insulations. Keywords: harmonics, distortion, waveforms, filters 1. Introduction In the last two decades, there has been an explosion of microprocessor based equipments which are known as nonlinear loads. These include computers, variable frequency drives, AC/DC converters, electronic ballasts, hospital endoscope equipment such as X-ray machines and MRI. Harmonics are voltage and current frequencies riding on top of the normal sinusoidal voltage and current waveforms. Nonlinear loads cause some distortion of AC line voltage and current. High harmonic content can disturb or damage the sensitive electronic equipment connected to the same power line or network with frequencies that are integer multiples of the fundamental frequency. It can result in variety of problems such as; system inefficiency, motors/transformers to run hot, audible noise from motor, improper operation of protection devices, high current in neutral conductor, low power factor and increased power system losses. In this paper, a test is carried out on the effect of using filters in limiting the impact of harmonic phenomena using the available powerful application of MATLAB to simulate the system components and the associated filters. 2. Overview: Power systems have always had harmonics present. In long past history of power system, harmonics were associated with distorted voltage and current wave shapes observed on transmission systems and they did not cause much of problems to industry office buildings as equipment was less sophisticated. Over the recent years, the increasing utilization of electronic devices brought the subject up-front. Electronic devices are very sensitive to their power quality environment. As the number of electronic devices increased, so did the number of other harmonic-creating devices are also increasing. Large industries such as steel and aluminum complexes used electricity to power arc furnaces which also distort the waveforms because the current flow is not directly proportional to the voltage. These non-linear loads cause waveforms that are multiples (Harmonics) of the normal frequency sine waves to be superimposed on the base waveform. For instance, the second harmonic is a 100 Hz waveform (2 times 50 Hz), the third is a 150 Hz waveform, and so on. The combination of the sine wave with all the harmonics creates a new, non sinusoidal wave of distortion. 3. Harmonics Distortions Harmonic frequencies can be "Even" or "Odd" multiples of the sinusoidal fundamental frequency. A linear electrical load is one, which draws a purely sinusoidal current when connected to a sinusoidal voltage source such as resistors, capacitors and inductors. Traditional devices connected to distribution systems such as transformers, motors and resistive heaters have linear characteristics. Nonlinear electrical loads are those which draw a nonsinusoidal current when connected to a sinusoidal voltage source. Fig1 illustrates an example of a periodic distorted waveform which repeats itself 50 times a second. Fig.1: Distorted A.C waveform (Fundamental plus 3rd Harmonic)

When a sinusoidal signal of a single frequency is applied at the input of a nonlinear device or circuit, the resulting output contains frequency components that are integer multiples of the input signal. These harmonics are generated by the nonlinearity of the circuit and the harmonic distortion is measured by comparing the magnitudes of the harmonics with the fundamental component (input frequency) of the output. Consider the input signal to be of the form: x(t) = Cos t / 2π 1 Where: = t / 2π is the amplitude of the input signal Let the output of the nonlinear circuit be: Y(t) = + Cos t + Cos t + Cos t +... 2 Where: is the dc component of the output is the amplitude of the fundamental component, & are the amplitudes of 2 nd and 3 rd harmonics. The 2 nd harmonic distortion factor ( ), the 3 rd harmonic distortion factor ( ), and the n th harmonic distortion factor ( ) are define as: = 3 = 4 = 5 The total harmonic distortion (THD) of a waveform is defined to be the ratio of the rms value of the harmonics to the amplitude of the fundamental component. THD = 6 content by virtue of the relatively high X/R ratio of their blocked rotor circuit. Harmonic voltages or currents give rise to additional losses in the stator windings, rotor/stator circuits and rotor/stator laminations. The losses in the stator and rotor conductors are greater than those associated with the d.c. resistances because of eddy currents and skin effect. Leakage fields set up by harmonic currents in the stator and rotor end-windings produce extra losses. In the case of induction motors with skew rotors, the flux changes in both stator and rotor and high frequency can produce substantial iron loss. The magnitude of these losses depends upon the amount of skew, and the iron-losses characteristics of the laminations. In considering the harmonic heating losses of synchronous machine rotors, it must be remembered that pairs of stator harmonics produce the same rotor frequency. For example the 5 th and 7 th harmonics both give induced rotor currents at frequency 6. Each of these currents takes the form of an approximately sinusoidal spatial distribution of damper bar currents traveling around the rotor at velocity 6 but in opposite directions. Thus for a linear system, the average rotor surface loss density around the periphery will be proportional to (I 2/5 + I 2/7), however because of their opposing rotations, at some point around the periphery the local surface loss density will be proportional to ( + ) 2 If the 5 th and 7 th harmonic currents are of similar magnitude then the maximum local loss density would be about twice the average loss density caused by these two currents. Extra power loss is probably the most serious effect of harmonics upon AC machines. An approximate assessment of the additional thermal stress of the coils can be achieved with the help of weighted distortion factor adapted to inductance i.e. THD can be expressed in terms of the individual harmonic distortion factors as: THD = 7 4. Harmonic Losses and effect on Rotating Machines Non-sinusoidal voltages applied to electrical machines may cause overheating. Motors are not normally derated so long as the harmonic distortion remains within the 5% normally recommended by the regulations [6]. Above that limit, they will often experience excessive heating problems. On the positive side, motors contribute to the damping of the system harmonic Where: α = 1 to 2 is the single frequency r.m.s. voltage at harmonic n, N is the maximum order of harmonic to be considered, and is the fundamental line to neutral r.m.s. voltage. The capability of a machine to cope with extra harmonic currents will depend on the total

additional losses and its effect on the overall machine temperature rise and local overheating (probably in the rotor). Cage-rotor induction motors tolerate higher rotor losses and temperatures provided that these do not result in unacceptable stator temperatures, whereas machines with insulated rotor windings may be more limited. Some guidance as to the probably acceptable levels may be obtained from the fact that the level of continuous negative-sequence current is limited to about 10% for generators and negativesequence voltage to about 2% for induction motors. It is therefore, reasonable to expect that if the harmonic content exceeds these negative sequence limits, then problems will start to occur. 5. Power System Model A three phase harmonic filter model is constructed to measure the influence on current and voltage waveforms in a way to reduce the effect of harmonic phenomena. The constructed circuit uses a 12 pulse AC/DC converter as shown in Fig. 2. Fig 2: Three-Phase Harmonic Filters Model used on a 12-pulse AC/DC Converter The HVDC rectifier is built up from two 6-pulse thyristor bridges connected in series. The converter is connected to the system with a large 3-ph transformer of 1200-MVA to view the overall effect harmonics in modeled large unites. A 1000-MW resistive load is connected to the DC side through a 0.5 H smoothing reactor. The filters set are made of the following components: 1. One capacitor bank (C1) rated at 150 MVAr modeled by a "Three-Phase Series RLC Load". 2. Three filters mode "Three-Phase Harmonic Filter" a) One C-type high-pass filter tuned to the 3rd (F1) of 150 MVAr. b) One double-tuned filter 11/13th (F2) of 150 MVAr. c) One high-pass filter tuned to the 24th (F3) of 150 MVAr. The total MVAr rating of the filters set is then 600 MVAr. A three-phase circuit breaker (Bk1) is used to connect the filters set on the AC bus. The converter is open-loop controlled using the "Synchronized 12-Pulse Generator" with a constant conduction angle alpha of 19 degrees. A three-phase power supply balanced source is implemented with internal R-L impedance. The sources connected in star with a neutral connection that can be internally grounded or made accessible. The source can therefore be specified as internal resistance and inductance either directly by entering R and L values or indirectly by indicating the source inductive short-circuit level and X/R ratio. A three-phase transformer with configurable winding connections is also implemented. The saturation characteristic was activated in the model as the fluxes are not specified, hence, the initial values are automatically adjusted and the simulation starts in steady state. The leakage inductances and resistance of each winding are given in p.u based on the transformer nominal power Pn and on the nominal voltage of the winding (V1,V2, or V3). An implementation of a universal power converter with selectable topologies and power electronic devices was made. These consist of up to six power switches connected in a bridge configuration. The Universal Bridge block allows simulation of converters using both naturally commutated (or line-commutated) power electronic devices (diodes or thyristors) and forced commutated devices (GTO,IGBT, MOSFET). The Universal Bridge block is considered as the basic block for building up of two-level voltage sourced converters (VSC). 6. Filters Design The Three-Phase Series RLC Load block implements a three-phase balanced load as a series combination of RLC elements. At the specified frequency, the load exhibits constant impedance. The active and reactive powers absorbed by the load are proportional to the square of the applied voltage. Shunt element three-phase harmonic filters were used in the power system model for decreasing voltage distortion and power factor correction (Fig 3). Nonlinear elements such as power electronic converters generate harmonic currents or harmonic voltages, which are injected into power system. The resulting distorted currents flowing through system impedance produce harmonic voltage distortion. Harmonic filters reduce distortion by diverting harmonic currents in low impedance paths.

Harmonic filters are designed to be capacitive at fundamental frequency, so that they are also used for producing reactive power required by converters and for power factor correction. In order to achieve an acceptable distortion, several banks of filters of different types are usually connected in parallel. The most commonly used filter types are: (1) Band-pass filters, which are used to filter lowest order harmonics such as 5 th, 7 th, 11 th, 13 th, etc. In (Figure 5), the constructed model showing a recording of the un-switched multiple of harmonic filters illustrating the voltage and current distortions at points of common coupling. As a result of the nature of load imposed to the system, the figure indicates the impact of such harmonic currents flowing into the system producing harmonic voltages resulting in the presence of great deal of distortion in voltage and current waveforms. Upon applying the designed specified filters, an appropriate enhanced sinusoidal waveforms were obtained as plotted in (Fig 6). Fig 3: Three-Phase Harmonic Filter These filters can be tuned at a single frequency (singletuned filter) or at two frequencies (double-tuned filter). (2) High-pass filters, which are used to clear highorder harmonics and cover a wide range of frequencies. A special type is the C-type high-pass filters which are used to provide reactive power and avoid parallel resonances. It also allows filtering low order harmonics (such as 3rd), while keeping zero losses at fundamental frequency. The Three-Phase Harmonic Filter is built of RLC elements. The resistance, inductance, and capacitance values are determined from the filter type and from the following parameters: - Reactive power at nominal voltage. - Tuning frequencies. - Quality factor which is a measure of the sharpness of the tuning frequency that is determined by the resistance value. The four types of filters that are modeled with the Three-Phase Harmonic Filter block are shown in Fig 4. Fig 4: Applicable filter Types 7. Results The following results were obtained form the simulation. Each with its specific condition of multiple filters switching state: Fig 5: Current and voltage waveforms before Switching-On the filters Fig 6:Typical Improvement of current and voltage waveforms in the filters Switched-On mode The results of the waveform shapes in (Figure 6) achieved by applying the multiple designed filters when compared with those waveforms recorded in (Figure 5) and before Switching-On the filters, clearly proves that such filters are beneficial to reduce the harmonic current which enhance the load voltage wave and the line current wave for a satisfactory steady state operation of the entire power system containing such operating characteristics. 8. Conclusions Harmonics are multiple of the fundamental frequency that continues to exist in our power systems and can distort or degrade the operating characteristics of any protective relays depending on the design features and principles of operation. Continuous operation of power systems with excessive harmonic current can also lead to increased voltage stress and

overheat and can shorten the live cycle of any installed capacitors. The paper concludes the essential of designing appropriate filters to dissipate and convey such harmonics which result in damage to its insulations. A remarkably, satisfactory results were obtained from the simulation as clearly indicated from the different waveforms illustrated before and after the application of the multiple filters which remarkably reduced the harmonic currents and enhanced the quality of system voltage and current sinusoidal waveforms. 9. REFERENCES [1] L. Daloub, R. Mustafa, "The Effect of Harmonics on Reactive Power Compensation of Distribution Networks", Cigre Regional Committee Conference, Muscat, Oman, Oct 2003. [2] Angelo Baggini, "Power Quality Hand Book", Willy, 2008 [3] El-Saadany E.F., Salama M.M.A"Effect of Interactions between Voltage and Current Harmoincs on the Net Harmonic Current Produced by Single Phase Linear Loads". Electric Power System Research, Vol 40, No 3, Mar 1997, pp 155-160(6). [4] S.M. Rafiei, "Optimal and Adaptive Compensation of Voltage and Current Harmonics Under Non-Stiff Voltage Conditions", IEE Proceedings: Generation Transmission and Distribution, ISSn 1350-2360, Vol 152, No 5, 2005, pages 661-672. [5] 4.P519A Task Force, Harmonics Working Group (IEEE PES t&d Committee) and SCC22-Power Quality "Guide for Applying Harmonic Limits on Power Systems" (Un-approved draft). [6] IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, ANSI/IEEE Std. 519-1992. [7] Timothy J.E. Miller, "Reactive Power Control in Electric Systems" John Wiley, Canada, 1982