D.C. Emmony, M.W. Godfrey and R.G. White

Similar documents
visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Theory and Applications of Frequency Domain Laser Ultrasonics

la. Smith and C.P. Burger Department of Mechanical Engineering Texas A&M University College Station Tx

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

Installation and Characterization of the Advanced LIGO 200 Watt PSL

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Low Vibration, Low Thermal Fluctuation System for Pulse Tube and Gifford- McMahon Cryocoolers

Real-time displacement measurement using VCSEL interferometer

Absolute distance interferometer in LaserTracer geometry

LONGITUDINAL TRACKING OF DIRECT DRIVE INERTIAL FUSION TARGETS. 2 General Atomics, P.O. Box 85608, San Diego CA

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

Enhancing the capability of primary calibration system for shock acceleration in NML

Development of C-Mod FIR Polarimeter*

OPSENS WHITE-LIGHT POLARIZATION INTERFEROMETRY TECHNOLOGY

First and second order systems. Part 1: First order systems: RC low pass filter and Thermopile. Goals: Department of Physics

Optical detection system for ultrasonic surface displacements

Extreme Sensitivity in Photoacoustics by Using Optical Cantilever-type Microphone

SENSITIVITY OF AN EMBEDDED FIBER OPTIC ULTRASOUND SENSOR

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

Use of Computer Generated Holograms for Testing Aspheric Optics

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

Vibration-compensated interferometer for measuring cryogenic mirrors

DEVELOPMENT OF HEAT-RESISTANT OPTICAL FIBER AE SENSOR

WIDE SPECTRAL RANGE IMAGING INTERFEROMETER

LOS 1 LASER OPTICS SET

A simple high-sensitivity interferometric position sensor for test mass control on an advanced LIGO interferometer

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Department of Electrical Engineering and Computer Science

Quantum frequency standard Priority: Filing: Grant: Publication: Description

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

1.6 Beam Wander vs. Image Jitter

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

Ph 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

OPSENS WHITE-LIGHT POLARIZATION INTERFEROMETRY TECHNOLOGY

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

The Lightwave Model 142 CW Visible Ring Laser, Beam Splitter, Model ATM- 80A1 Acousto-Optic Modulator, and Fiber Optic Cable Coupler Optics Project

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

SECOND HARMONIC GENERATION AND Q-SWITCHING

Coherence radar - new modifications of white-light interferometry for large object shape acquisition

Characterization of Silicon-based Ultrasonic Nozzles

Periodic Error Correction in Heterodyne Interferometry

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza

NCSL International 2995 Wilderness Place, Suite 107 Boulder, Colorado Office: (303) Fax: (303)

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Stabilizing an Interferometric Delay with PI Control

Precision displacement measurement by active laser heterodyne interferometry

Autocorrelator MODEL AA- 10DM

Results from the Stanford 10 m Sagnac interferometer

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

International Conference on Space Optics ICSO 2000 Toulouse Labège, France 5 7 December 2000

ADAPTIVE PHOTODETECTORS FOR VIBRATION MONITORING

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

06SurfaceQuality.nb Optics James C. Wyant (2012) 1

First Observation of Stimulated Coherent Transition Radiation

FIDELITY OF MICHELSON INTERFEROMETRIC AND CONICAL PIEZOELECTRIC

Designing Optical Layouts for AEI s 10 meter Prototype. Stephanie Wiele August 5, 2008

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

DEVELOPMENT OF STABILIZED AND HIGH SENSITIVE OPTICAL FI- BER ACOUSTIC EMISSION SYSTEM AND ITS APPLICATION

Back-Reflected Light and the Reduction of Nonreciprocal Phase Noise in the Fiber Back-Link on LISA

Multiply Resonant EOM for the LIGO 40-meter Interferometer

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

R. J. Jones Optical Sciences OPTI 511L Fall 2017

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

A novel tunable diode laser using volume holographic gratings

Dynamics of a bistable VCSEL subject to optical feedback from a vibrating rough surface

A Laser Interferometer for the Undergraduate Teaching Laboratory Demonstrating Picometer Sensitivity

William R. Scott, Stephen Huber*, and Martin Ryan

Surface Finish Measurement Methods and Instrumentation

2 CYCLICAL SHEARING INTERFEROMETER

OPTICAL FIBER-BASED SENSING OF STRAIN AND TEMPERATURE

LASER ULTRASONIC THERMOELASTIC/ABLATION GENERATION WITH LASER INTERFEROMETRIC DETECTION IN GRAPHITE/POLYMER COMPOSITES

Experiments with wave, using low-cost amplitude modulated ultrasonic techniques

CO2 laser heating system for thermal compensation of test masses in high power optical cavities. Submitted by: SHUBHAM KUMAR to Prof.

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

Why is There a Black Dot when Defocus = 1λ?

INTERFEROMETRIC VIBRATION DISPLACEMENT MEASUREMENT

Politecnico di Torino. Porto Institutional Repository

R. D. Huber and G. H. Thomas

Heterodyne Interferometry with a Supercontinuum Local Oscillator. Pavel Gabor Vatican Observatory, 933 N Cherry Ave., Tucson AZ 85721, USA

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

Initial Results from the C-Mod Prototype Polarimeter/Interferometer

Experience with Signal- Recycling in GEO600

Experimental Test of an Alignment Sensing Scheme for a Gravitational-wave Interferometer

Advances in laboratory modeling of wave propagation

Evaluation of Scientific Solutions Liquid Crystal Fabry-Perot Etalon

Measure the roll-off frequency of an acousto-optic modulator

An Arduino based automated procedure for measuring refractive indices of optical materials for educational purposes using Michelson s interferometer

LISA and SMART2 Optical Work in Europe

Microscopic Laser Doppler Vibrometer

Transcription:

A MINIATURE OPTICAL ACOUSTIC EMISSION TRANSDUCER ABSTRACT D.C. Emmony, M.W. Godfrey and R.G. White Department of Physics Loughborough University of Technology Loughborough, Leicestershire LEll 3TU United Kingdom The optical transduction of acoustic emission signals offers many advantages over piezoelectric devices. These include high bandwidth, no modification to the signal as well as providing contactless measurement. The major difficulties associated with optical devices are stability against low frequency vibrations and the generally complex nature of an optical interferometer. This paper describes the attempts to miniaturize a Michelson interferometer while at the same time overcoming some of the stability problems associated with these devices. Active stability of an interferometric transducer with dimensions of ~ 5cm (2") cube has been achieved over 8 fringes of red light at 100Hz and 4 fringes at 300Hz. The range of active stabilization of the interferometer is limited by the frequency response of the large amplitude piezoelectric element and the filter characteristics of the feedback electronics. A sensitivity of 0.5R (0.5 x 10-lOm) has been achieved. INTRODUCTION The ideal acoustic emission transducer will possess a number of characteristics. It will not need to be contacted to the surface being investigated and therefore will not load the surface in any way. Consequently the signal being measured will be unchanged. Because the optical sensing beam is massless it is theoretically capable of a very wide bandwidth. Light can be focussed and therefore the area of the surface being investigated can be very small. Conventional piezoelectric transducers do not fullfill 533

534 D. C. EMMONY ET AL. the above criteria but they are very sensitive. Capacitative transducers can be made to have a high sensitivity but at the expense of large interaction area and a requirement for a high degree of finish on the structure surface. Several authors1,2 have investigated the use of optical interferometry to measure small high frequency displacements such as those associated with acoustic emission events. The interferometers tend to be relatively large instruments requiring substantial mechanical stability and are therefore rather unsuited to most practical experimental environments. A microscope interferometer has been modified using,a cantilever driven reference mirror to allow active stabilization of the instrument against low frequency vibrations. This has advantages over a thickness mode piezoelectric reference in that the excursions of the reference mirror can be several wavelengths for the application of relatively low voltages. However, optimisation of the stabilization must be a careful trade-off between bandwidth and the range of stabilization. INTERFEROMETRY DESIGN The principle of operation of an optical interferometer is well known. Briefly the optical path difference (OPD) between a sensing beam and a reference beam varies as shown in fig. 1. When the OPD is zero or an integer number of wavelengths the two beams constructively interfere leading to a maximum signal on a.photodetector (A). When the OPD is given by (n+i)a where A is the light wavelength, then the photodetector signal is zero (B). It can be seen that the sensitivity of the interferometer is given by di/dx and this is a maximum when the OPD is an odd number of A/4 at c. Therefore to maintain maximum sensitivity the reference mirror must be adjusted and maintained to satisfy this last criterion. This is known as optical stabilization and is normally carried out by means of some active element in the reference beam together with feedback to maintain the mid-fringe position near C. The sensitivity is not a Detedor A A A Figure 1.

MINIATURE OPTICAL ACOUSTIC EMISSION TRANSDUCER 535 strongly varying function around C. A 20% excursion from Conly results in a 2% change 1n calibration. Palmer and Green l have used the Mirau or Fizeau in-line interferometer as well as the Michelson. In the former the reference mirror is on or near the focussing lens which leads to a compact design which is particularly insensitive to axial bending, but in any attempt at miniaturization the position of the reference mirror is rather inaccessible. In the Michelson interferometer the reference mirror is parallel to the axis of the instrument as in fig. 1. In order to compensate for low frequency vibrations the reference mirror must be capable of moving at the same speed as the subject mirror and the amplitude of the reference mirror must also be equal to that of the subject. Thickness mode ceramics typically have piezoelectric coefficients of ~ 10-6mm V-I with a corresponding 300 volts required for one complete fringe traversal. This is the lowest voltage acceptable if an over-under switch in the electronic circuitry is to be avoided with the associated dead time in these arrangements (Palmer and Green) I. In order to provide continuous access it was decided that the optical stabilizing system should be capable of compensation over several fringes and that this was best done using a reference mirror attached to a piezoelectric bimorph which acts as a cantilever. Initially an optical bench interferometer was constructed for feasibility tests and then a surface finish interference microscope objective was adapted by the installation of a 3mm long piezoelectric bimorph element with a 1mm diameter aluminised mylar mirror at the free end. The characteristics of the bimorph are such that the amplitude is l~m with the application of 150 volts. A full account of the stabilization and cantilever properties will be given elsewhere. The interference objective is based on a Michelson interferometer with the beam splitter cube arranged to lie just above the normal specimen surface (fig. 2). In its unmodified state the objective may be used with white light, that is the reference arm exactly matches the distance to the focus. The reference mirror mount was removed and replaced by the cantilever mirror and its associated power supply leads. A 2mW ReNe laser was coupled to the interferometer by a rigid rectangular box containing a x10 microscope objective and a 50% reflecting beam splitter. The optical system is shown diagrammatically in fig. 3. The single transverse mode ReNe laser has a beam diameter of ~ 1mm and the x10 objective spreads this beam to fill the interference objective. The laser radiation traverses the interferometer and returns to the beam splitter where half of the laser energy is deflected to the silicon photodiode. This simple photodetector is used to detect high frequency oscillations as 1n acoustic emission and also acts as the sensor in the optical

536 D. C. EMMONY ET AL. f.- Figure 2. stabilization feedback loop. returned to the photodiode. Only 12.5% of the HeNe laser beam is CHARACTERISTICS OF THE TRANSDUCER The performance of the transducer was assessed and amplitude calibration carried out using a cantilever target and a thickness Photodetector Reference mirror Figure 3.

MINIATURE OPTICAL ACOUSTIC EMISSION TRANSDUCER 537 mode piezoelectric plate. The cantilever target which was essentially of the same construction as the stabilising reference mirror was driven by an r.f. oscillator at 50kHz and the amplitude was such that more than one whole interference fringe was displayed on an oscilloscope. This gave the photodetector output with displacement and allowed the minimum displacement above the noise level to be measured. This figure was then confirmed by using the thickness mode ceramic at the same frequency but with a displacement amplitude down to the noise level using the theoretical piezoelectric coefficient. The minimum detectable displacement measured as described above was 0.5R. Calculations on shot noise for a Michelson interferometer employing a 2mW laser as a light source suggest this figure is an order of magnitude too large 3 The major contribution to the degradation of the noise ratio was found to be loss of light energy in the system due to unwanted reflections. In addition to increasing the shot noise to signal ratio this also puts more stringent requirements on amplifier noise levels. The system was limited by amplifier noise; laser noise was not a problem. The characteristics of the stabilization loop were also determined. A long cantilever element and mirror acting as an object surface was driven with an oscillator. The ability of the stabilizing system to maintain the fringe mid-point as the amplitude of the oscillations increased was noted as a function of frequency. The system was able to maintain stability over 8 fringes at 100Hz but only 2! fringes at 500Hz. Using more elaborate electronic filtering it should be possible to extend the 500Hz figure to 3! fringes. The present stability range is the result of careful optimisation of the bimorph length, the feedback filter points and the total system gain. CONCLUSION AND DISCUSSION The prototype transducer described here uses a small interferometer 4 but the whole instrument including laser light source has dimensions 5 x 5 x 40cm. Several modifications can in principle lead to a very compact overall instrument. It is stated above that the optical system is very wasteful in laser light and the 12.5% figure does not include reflection losses. The laser input/output beamsplitter could be dispensed with by positioning the photodetector in the unused beam of the interferometer opposite the reference mirror with an immediate improvement of light on the detector of 400%. Furthermore, the signal to noise ratio could be improved with the use of a higher power laser. The removal of the input/output beamsplitter would lead to a shortening of the light source unit but the need to fill the microscope objective aperture may still require a diverging lens.

538 D. C. EMMONY ET AL. Considerable reduction ~n s~ze is feasible with a change in light source. The use of a semiconducter injection laser is an obvious choice although a move into the infrared may involve a reduction in sensitivity as well as difficulties in setting up the instrument. In conclusion, it should be possible to increase the sensitivity to o.osr (S x 10-12m) by adopting some of the above modifications and by making use of low noise detector/amplifier combinations. ACKNOWLEDGEMENTS This project was carried out with support from the Procurement Executive, Ministry of Defence. M.W.G. and R.G.W. acknowledge the support of SERC and University Research Studentships respectively. REFERENCES 1. C. H. Palmer and R. E. Green, Jr. "Optical Probing of Acoustic Emission Waves, Final Report," U.S. Army Research Office, 31 August, 1979. 2. D. Vilkomeson, "Measuring Pulsed Picometer Displacement Vibrations by Optical Interferometry," Appl. Phys. Lett. 29, (1976),183-8S. 3. Th. Kwaaitaal, B. J. Luymes and G. A. van der Pijl1, "Noise Limitations of Michelson Laser Interferometers," J. Phys. D. 13: 100S (1980). 4. Vickers Instruments, York, United Kingdom.