LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Similar documents
LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Characteristics 5 TeSys k contactors and reversing contactors

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

Modular equipment. Presentation, standards. Standard contactors TeSys GC

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Motor starters. TeSys E. Designed for the essential

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

3 - Protection components Circuit-breakers

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

NS..S contactor relays - with spring terminals AC operated

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RENF22R2MMW Zelio Timer Relay - Modular

Components for safety applications

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Protection components

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

Electromechanical pressure and vacuum switches 0

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

Zelio Control Measurement Relays

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pendant control stations 6

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Protection components

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

References 1 for asynchronous motors 1

Pendant control stations 6

Pendant control stations 6

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

Page 13-2 Page Page 13-7

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Type: DILEM 10 G(24VDC) Article No.:

Zelio Plug-In Relays. RXG interface relays. Catalog

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Complete units: Mushroom heads ø 22mm

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

38 Series - Relay interface modules A. Features /

Control Stations ø 22

Type CP-S, CP-C & CP-A Switch mode

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

48 Series - Relay interface modules A. Features

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Complete units: Push-buttons ø 22mm

Complete units: Selector switches ø 22mm

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Transcription:

Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Power pole contact composition [Ue] rated operational voltage [Ie] rated operational current Motor power kw Motor power HP (UL / CSA) Control circuit type [Uc] control circuit voltage Auxiliary contact composition Jan 17, 2019 TeSys TeSys D Reversing contactor LC2D Motor control Resistive load AC-1 AC-3 Preassembled with reversing power busbar 3P 3 NO <= 300 V DC for power circuit <= 690 V AC 25...400 Hz for power circuit 25 A (<= 60 C) at <= 440 V AC AC-1 for power circuit 9 A (<= 60 C) at <= 440 V AC AC-3 for power circuit 4 kw at 380...400 V AC 50/60 Hz 2.2 kw at 220...230 V AC 50/60 Hz 5.5 kw at 500 V AC 50/60 Hz 5.5 kw at 660...690 V AC 50/60 Hz 4 kw at 415...440 V AC 50/60 Hz 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors DC low consumption 24 V DC 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947 Overvoltage category III 1 Disclaimer: This documentation is not inted as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

[Ith] conventional free air thermal current 25 A at <= 60 C for power circuit 10 A at <= 60 C for signalling circuit Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Safety cover Interlocking type Mounting support 105 A <= 40 C 10 s power circuit 210 A <= 40 C 1 s power circuit 30 A <= 40 C 10 min power circuit 61 A <= 40 C 1 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 20 A gg at <= 690 V coordination type 2 for power circuit 25 A gg at <= 690 V coordination type 1 for power circuit 10 A gg for signalling circuit conforming to IEC 60947-5-1 2.5 mohm at 50 Hz - Ith 25 A for power circuit 600 V for power circuit certifications CSA 600 V for power circuit certifications UL 690 V for power circuit conforming to IEC 60947-4-1 690 V for signalling circuit conforming to IEC 60947-1 600 V for signalling circuit certifications CSA 600 V for signalling circuit certifications UL 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 0.2 W AC-3 1.56 W AC-1 With Mechanical Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals Tightening torque Operating time BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable Power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable Power circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable Power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable Power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 65.45...88.55 ms closing 20...30 ms opening 2

Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability 30 Mcycles Operating rate 3600 cyc/h at <= 60 C Complementary Coil technology Control circuit voltage limits Time constant Built-in bidirectional peak limiting diode suppressor 0.1...0.3 Uc drop-out at 60 C, DC 0.8...1.25 Uc operational at 60 C, DC 40 ms Inrush power in W 2.4 W at 20 C Hold-in power consumption in W 2.4 W at 20 C Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma for signalling circuit 17 V Signalling circuit 1.5 ms on de-energisation (between NC and NO contact) 1.5 ms on energisation (between NC and NO contact) > 10 MOhm for signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation -20...60 C Ambient air temperature for storage -60...80 C Permissible ambient air temperature around the device Operating altitude -40...70 C at Uc 3000 m without derating in temperature Fire resistance 850 C conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor open 10 Gn for 11 ms Shocks contactor closed 15 Gn for 11 ms 77 mm 90 mm 95 mm 1.017 kg Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product of life instructions Green Premium product Compliant - since 0721 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product Environmental Profile Available End of Life Information 3

Contractual warranty Warranty period 18 months 4

Product datasheet Dimensions Drawings LC2D09BL Dimensions LC2 or 2 x LC1 a b c (1) e1 e2 G D09 to D18 (AC) 90 77 86 4 1.5 80 D093 to D123 (AC) 90 99 86 80 D09 to D18 (DC) 90 77 95 4 1.5 80 D093 to D123 (DC) 90 99 95 80 D25 to D38 (AC) 90 85 92 9 5 80 D183 to D383 (AC) 90 99 92 80 D25 to D32 (DC) 90 85 101 9 5 80 D183 to D383 (DC) 90 99 101 80 e1 and e2: including cabling. (1) With safety cover, without add-on block. 5

Product datasheet Connections and Schema LC2D09BL Wiring 6