COMPARISON OF THE MEDICONTUR 860FAB

Similar documents
ROTATIONAL STABILITY MAKES THE DIFFERENCE

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

Dr. Magda Rau Eye Clinic Cham, Germany

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

József Győry. Veszprem, Hungary

Raise your expectations. Deliver theirs.

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Long-term quality of vision is what every patient expects

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

Clinical Evaluation 3-month Follow-up Report

Evolution of Diffractive Multifocal Intraocular Lenses

Clinical Update for Presbyopic Lens Options

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

IOL Review and FLACS Update

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Intraocular lens Difficulties

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Treatment of Presbyopia during Crystalline Lens Surgery A Review

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

Improving Lifestyle Vision. with Small Aperture Optics

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Evolution of the Cataract Patient

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Medicontur IOLs: Materials & Design Main Characteristics

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Ocular Scatter. Rayleigh Scattering

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

Aberrations Before and After Implantation of an Aspheric IOL

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Unique Aberration-Free IOL: A Vision that Patients

Comparison of Visual Performance with Photochromic, Yellow and Clear Intraocular Lenses

Advanced Technology IOLs

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

The Aberration-Free IOL:

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

AFollowing cataract or refractive lens surgery, the crystalline

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Roadmap to presbyopic success

Clinical Evaluation 3-month Follow-up Report

Multifocal and Accommodative

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress!

Multifocal IOL Basics

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Advances in the design and

UIN: IOL Date of Prep: April Avansee Preload1P. Technical Slide Kit April 2017

The Dysphotopsia Mystery. John J. Bussa, M.D.

Preloaded. PreciSAL. EZ Toric

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

THE ASPHERIC PRELOADED INJECTION

The Miracle of Pi in Eye. Rajesh Khanna, MD

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

Wide Diopter Range and Different Haptic Platforms

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

The complete choice in refractive lens solutions

LASIK & Refractive Surgery

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design

ASPIRA PUBLICATION LIST

Vision for What They Love.

IOL Predictions for the Coming Year

Sulcoflex Pseudophakic Supplementary IOLs

Accommodating IOL s History and Clinical Management

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs

University of Groningen. Young eyes for elderly people van Gaalen, Kim

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs

Easy to identify: The color-coded forceps and scissors make identification during September September September 2016

Comparison of Contrast Sensitivity in Eyes with Toric and Aspheric Intraocular Lenses

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

Update on Aspheric IOL Technology

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

The Blueprint for Improved Image Quality

In vitro optical performance of a new aberration-free intraocular lens

Aberrometry in Clinical Practice

Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

HYDROPHILIC ACRYLIC ADVANCED POLYMER

Transcription:

COMPARISON OF THE MEDICONTUR 860FAB HYDROPHOBIC IOL AND THE ACRYSOF IQ LONG TERM FOLLOW UP Péter Vámosi MD, Amanda Argay MD, Zsófia Rupnik MD, János Fekete Péterfy Sándor Hospital Budapest, Hungary

PREFERENCE OF AMERICAN OPHTHALMOLOGIST What optic material would you want in an IOL implanted in your own eye regardless of cost? And why? Type of material Hydrophobic acrylic 63% Silicone 19% Collamer 9% Hydrophilic acrylic 9% PMMA 0% Assuming no astigmatism, cost no factor, and considering all aspects such as vision quality, near quality, risk of needing LVC after and complication risk, what IOL regimen would you what in your own eyes? And why? Type of IOL Conventional IOL, emmetropia OU and wear reading glasses 37% Conventional IOL with monovision 37% Multifocal IOL 16% Crystalens, emmetropia OU 2% Crystalens, with a judicious amount of monovision boost 8% Gossman M: What intraocular lens would you want in your eyes? EyeWorld 21(7): 34 (2016)

MEDICONTUR HYDROPHOBIC IOLS Since 2011 on the market Z-Flex or 860FAB / 860FABY Bi-Flex or 877FAB / 877FABY SEMTE hydrophobic co-polymer material - reduced tackiness - optimal glass transition temperature (Tg) at 4 C - excellent pseudo-plasticity for quick centration and positioning - low rate of cell adhesion enhanced PCO prevention Z-Flex Bi-Flex More than 4000 implantation

MEDICONTUR HYDROPHOBIC IOLS Specific lathe cut manufacturing and patented design guarantees the sharp square edge all over 360 including the optic haptic junction zone SEMTE material presents the highest ABBE number (57) on the market resulting in low chromatic aberration and excellent optical quality

DEMOGRAPHIC DATA Aim: Compare retrospectively the performance of two hydrophobic IOLs 860FAB (Medicontur), 26 eyes, 76.09 (±5.3) years SN60WF (Alcon), 25 eyes, 70.60 (±8.1) years One surgeon Average follow-up: 4.0 years Exclusion criteria: Any intra- or postoperative complication during phaco Corneal or retinal pathology Severe dry eye Severe or untreated glaucoma Anterior capsulorhexis covers not in 360 the edge of the optic Other ocular surgery than previous phaco Previous YAG laser capsulotomy

REFRACTIVE STABILITY 70% 68% 35% 44% Pearson s chi-square (Yates continuity correction) (χ²=0.159, p=0.690) (χ²=0.009, p=0.925) Mean spherical equivalent (Mann-Whitney U test): Medicontur +0.36 D Alcon +0.19 D (p=0.416)

CDVA 860FAB 0.08 (±0.14) logmar ~ 0.91 decimal SN60WF 0.02 (±0.06) logmar ~ 0.96 decimal Mann-Whitney U teszt (U=248.500, p=0.052) 3 eyes in the Medicontur group moderate to severe amblyopia

CONTRAST SENSITIVITY CSV-1000 SYSTEM Mann-Whitney U test (U=272.00 p=0.425) (U=236.00 p=0.139) No difference in the average CS, or at any spatial frequencies

PCO, OBJECTIVE MEASURING Rotating Scheimpflug camera (Pentacam HR, Oculus) Density value of PCO on Scheimpflug slit image Pixel intensity using ImageJ64 medical imaging software Area inside the capsulorhexis Area densitometry light intensity of each pixel was analyzed automatically between 0 (white) and 255 (black) Hirnschall N et al. Comparison of methods to quantify posterior capsule opacification using forward and backward light scattering. J Cataract Refract Surg 40:728-735 (2014)

PCO, OBJECTIVE MEASURING Levene test 860FAB 40.7 (±10.7) 20.2 (11.7) SN60WF 41.4 (±10.1) p=0.82 30.5 (7.3) p<0.001

GLISTENINGS, OBJECTIVE MEASURING Glistenings consist of multiple microvacuoles in IOLs that cause retinal stray light and may affect quality of vision Scheimpflug photography (Pentacam HR) and subsequent digital image analysis by ImageJ program Full thickness and deep glistenings Behndig A, Mönestam E: Quantification of glistenings in intraocular lenses using Scheimpflug photography. J Cataract Refract Surg 35:14-17 (2009)

GLISTENINGS OBJECTIVE AND SUBJECTIVE MEASURING Mann-Whitney U test 34.1 (±1.6) 39.7 (±3.7) p<0.0001 Mann-Whitney U test 0.58(±0.6) 1.82 (±0.9) p<0.0001 objective and subjective measurement strength of association: r=0.446

GLISTENINGS DOES IT MATTER? Last 20 years ~ 8000 foldable Medicontur IOLs no explantation because of a problem of lens material ~ 4000 foldable Alcon IOLs 2 explantations because of glistenings Diminished CS, MTF, color vision Oshika T et al. Influence of glistenings on the optical quality of acrylic foldable intraocular lens. Br J Ophthalmol 85:1034-1037(2001) 67 years old woman, 10 years postop. AcrySof MA60AC

CLEAR OR YELLOW-TINTED? Yellow tint or clear in your eye? Clear 86% Yellow 14% No final certainty Sometimes yellow is favourable Gossman M: What intraocular lens would you want in your eyes? EyeWorld 21(7): 34 (2016) Exclusively yellow platform (Alcon) Exclusively clear platform (AMO) Medicontur has both

CONCLUSIONS Medicontur hydrophobic IOLs have unique material and lens design, which provide the good visual performance of these lenses Against other hydrophobic materials these IOLs are less sticky, very flexible and easy to implant Medicontur hydrophobic IOLs are firm competitors on the hydrophobic market