OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY

Similar documents
PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

CHARACTERIZATION OF PASCHEN CURVE ANOMOLIES AT HIGH P*D VALUES

ANALYSIS OF A PULSED CORONA CIRCUIT

INVESTIGATION OF A HIGH VOLTAGE, HIGH FREQUENCY POWER CONDITIONING SYSTEM FOR USE WITH FLUX COMPRESSION GENERATORS

TRANSMISSION LINE AND ELECTROMAGNETIC MODELS OF THE MYKONOS-2 ACCELERATOR*

PHASING CAPABILITY. Abstract ARRAY. level. up to. to 12 GW. device s outpu antenna array. Electric Mode. same physical dimensions.

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

PULSED POWER SWITCHING OF 4H-SIC VERTICAL D-MOSFET AND DEVICE CHARACTERIZATION

L. B. Gordon Space Power Institute 231 Leach Center Auburn University, Alabama 36849

IB2-1 HIGH AVERAGE POWER TESTS OF A CROSSED-FIELD CLOSING SWITCH>:< Robin J. Harvey and Robert W. Holly

RAVEN, A 5 kj, 1.5 MV REPETITIVE PULSER* G. J. Rohwein Sandia National Laboratories Albuquerque, New Mexico 87185

A NEW BROADBAND PULSED HIGH VOLTAGE MONITOR *

FLASH X-RAY (FXR) ACCELERATOR OPTIMIZATION BEAM-INDUCED VOLTAGE SIMULATION AND TDR MEASUREMENTS *

David L. Lockwood. Ralph I. McNall Jr., Richard F. Whitbeck Thermal Technology Laboratory, Inc., Buffalo, N.Y.

Development of a charged-particle accumulator using an RF confinement method FA

ANALYSIS OF SWITCH PERFORMANCE ON THE MERCURY PULSED- POWER GENERATOR *

DEVELOPMENT OF AN ULTRA-COMPACT EXPLOSIVELY DRIVEN MAGNETIC FLUX COMPRESSION GENERATOR SYSTEM

DIELECTRIC ROTMAN LENS ALTERNATIVES FOR BROADBAND MULTIPLE BEAM ANTENNAS IN MULTI-FUNCTION RF APPLICATIONS. O. Kilic U.S. Army Research Laboratory

Robotics and Artificial Intelligence. Rodney Brooks Director, MIT Computer Science and Artificial Intelligence Laboratory CTO, irobot Corp

A RENEWED SPIRIT OF DISCOVERY

Durable Aircraft. February 7, 2011

Strategic Technical Baselines for UK Nuclear Clean-up Programmes. Presented by Brian Ensor Strategy and Engineering Manager NDA

DEVELOPMENT OF STITCH SUPER-GTOS FOR PULSED POWER

MERQ EVALUATION SYSTEM

Loop-Dipole Antenna Modeling using the FEKO code

EFFECTS OF ELECTROMAGNETIC PULSES ON A MULTILAYERED SYSTEM

ULTRA FAST, HIGH REP RATE, HIGH VOLTAGE SPARK GAP PULSER

Best Practices for Technology Transition. Technology Maturity Conference September 12, 2007

Technology Maturation Planning for the Autonomous Approach and Landing Capability (AALC) Program

Solar Radar Experiments

SILICON CARBIDE FOR NEXT GENERATION VEHICULAR POWER CONVERTERS. John Kajs SAIC August UNCLASSIFIED: Dist A. Approved for public release

FAA Research and Development Efforts in SHM

MINIATURIZED ANTENNAS FOR COMPACT SOLDIER COMBAT SYSTEMS

Presentation to TEXAS II

Signal Processing Architectures for Ultra-Wideband Wide-Angle Synthetic Aperture Radar Applications

COMPACT FLASH X-RAY UNITS. Abstract

[Research Title]: Electro-spun fine fibers of shape memory polymer used as an engineering part. Contractor (PI): Hirohisa Tamagawa

A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND

Underwater Intelligent Sensor Protection System

AN INSTRUMENTED FLIGHT TEST OF FLAPPING MICRO AIR VEHICLES USING A TRACKING SYSTEM

ULTRASTABLE OSCILLATORS FOR SPACE APPLICATIONS

REPORT DOCUMENTATION PAGE

14. Model Based Systems Engineering: Issues of application to Soft Systems

HIGH TEMPERATURE (250 C) SIC POWER MODULE FOR MILITARY HYBRID ELECTRICAL VEHICLE APPLICATIONS

8.2. Washington, D. C delivered 65 kj into a matched load with 63 ns FWHM. Peak power was about 1 TW.

REPORT DOCUMENTATION PAGE

Lattice Spacing Effect on Scan Loss for Bat-Wing Phased Array Antennas

0.18 μm CMOS Fully Differential CTIA for a 32x16 ROIC for 3D Ladar Imaging Systems

Modeling Antennas on Automobiles in the VHF and UHF Frequency Bands, Comparisons of Predictions and Measurements

VHF/UHF Imagery of Targets, Decoys, and Trees

EXPERIMENTS ON A HIGH-VACUUM, HIGH-ELECTRIC FIELD STRESS PULSED POWER INTERFACE

Acoustic Measurements of Tiny Optically Active Bubbles in the Upper Ocean

A Comparison of Two Computational Technologies for Digital Pulse Compression

Coherent distributed radar for highresolution

COM DEV AIS Initiative. TEXAS II Meeting September 03, 2008 Ian D Souza

RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY

Modeling of Ionospheric Refraction of UHF Radar Signals at High Latitudes

Research on High Power Railguns at the Naval Research Laboratory

Design of Synchronization Sequences in a MIMO Demonstration System 1

Adaptation of ASTERIX to Positive Polarity for 2 to 4-MV Rod-Pinch Diode Experiments and Diode Electrical Analysis *

REPORT DOCUMENTATION PAGE

Two-Way Time Transfer Modem

Thermal Simulation of a Silicon Carbide (SiC) Insulated-Gate Bipolar Transistor (IGBT) in Continuous Switching Mode

PERFORMANCE OF A 10 KV, 625 KA, 85 KJ ENERGY DISCHARGE MODULE UTILIZING A SOLID DIELECTRIC SWITCH.*

3. Faster, Better, Cheaper The Fallacy of MBSE?

Ship echo discrimination in HF radar sea-clutter

U.S. Army Training and Doctrine Command (TRADOC) Virtual World Project

Ultrasonic Nonlinearity Parameter Analysis Technique for Remaining Life Prediction

INSULATION AND DIELECTRIC BREAKDOWN DESIGN CONSIDERATIONS IN SUB-ATMOSPHERIC ENVIRONMENTS

UNCLASSIFIED UNCLASSIFIED 1

Key Issues in Modulating Retroreflector Technology

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

REPORT DOCUMENTATION PAGE. Thermal transport and measurement of specific heat in artificially sculpted nanostructures. Dr. Mandar Madhokar Deshmukh

NEURAL NETWORKS IN ANTENNA ENGINEERING BEYOND BLACK-BOX MODELING

Modeling an HF NVIS Towel-Bar Antenna on a Coast Guard Patrol Boat A Comparison of WIPL-D and the Numerical Electromagnetics Code (NEC)

"OPTIMAL SIMULATION TECHNIQUES FOR DISTRIBUTED ENERGY STORE RAILGUNS WITH SOLID STATE SWITCHES"

Evanescent Acoustic Wave Scattering by Targets and Diffraction by Ripples

Innovative 3D Visualization of Electro-optic Data for MCM

A HIGH-PRECISION COUNTER USING THE DSP TECHNIQUE

ANALYSIS OF WINDSCREEN DEGRADATION ON ACOUSTIC DATA

INTEGRATIVE MIGRATORY BIRD MANAGEMENT ON MILITARY BASES: THE ROLE OF RADAR ORNITHOLOGY

INFRASOUND SENSOR MODELS AND EVALUATION. Richard P. Kromer and Timothy S. McDonald Sandia National Laboratories

2008 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies INFRAMONITOR: A TOOL FOR REGIONAL INFRASOUND MONITORING

SA Joint USN/USMC Spectrum Conference. Gerry Fitzgerald. Organization: G036 Project: 0710V250-A1

Non-Data Aided Doppler Shift Estimation for Underwater Acoustic Communication

An experimental system was constructed in which

Effects of Fiberglass Poles on Radiation Patterns of Log-Periodic Antennas

Wavelength Division Multiplexing (WDM) Technology for Naval Air Applications

Reduced Power Laser Designation Systems

A 1.1 MV REP-RATE IN-LINE OUTPUT SWITCH AND TRIGGERING SYSTEM

Acoustic Monitoring of Flow Through the Strait of Gibraltar: Data Analysis and Interpretation

USAARL NUH-60FS Acoustic Characterization

Frequency Stabilization Using Matched Fabry-Perots as References

Validated Antenna Models for Standard Gain Horn Antennas

Bistatic Underwater Optical Imaging Using AUVs

EFFECT OF TRANSFORMER LEAKAGE INDUCTANCE ON THE THREE PHASE CAPACITIVE INPUT RECTIFIER

Characteristics of an Optical Delay Line for Radar Testing

Ground Based GPS Phase Measurements for Atmospheric Sounding

Hybrid QR Factorization Algorithm for High Performance Computing Architectures. Peter Vouras Naval Research Laboratory Radar Division

AFRL-RX-WP-TP

Transcription:

OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY K. Koppisetty ξ, H. Kirkici 1, D. L. Schweickart 2 1 Auburn University, Auburn, Alabama 36849, USA, 2 Air Force Research Laboratory, Wright Patterson Air Force Base, Ohio 45433, USA. Abstract In general, power devices and systems operating in vacuum or space environment are more susceptible to partial discharges, corona, or volume discharge due to the partial vacuum conditions. Partial discharge and breakdown measurements have been performed on electrical equipment operating in such environments for over decades. In spite of all the studies, fundamental understanding of partial discharge or corona initiation has not been understood completely. Various means of detection have been used over the years, including the detection of electromagnetic emissions using antennas or by observing the current through the ground cables to obtain a better understanding. The measurements are usually analyzed together with other techniques like visual inspection, transient voltage/current measurements and acoustic/optical characteristics. In this paper we present our work on optical emission characteristics of breakdown events at partial vacuum for point-to-plane electrode configuration, operating at dc and 20 khz frequency in helium. A dc-offset-ac voltage source for the high frequency experiments and a pure dc power supply for dc breakdown experiments were used. Preliminary data of voltage and current waveforms along with the light emission data are presented. The optical signal detection of this set-up includes a photo-multipliertube and a digital pico-ammeter. Optical data collected by a PMT (Photo Multiplier Tube) as a function of time is presented. Presence of optical emission was also recorded by a video camera and frame-by-frame images were used for data analysis. I. INTRODUCTION The next generation space vehicles are likely to utilize higher voltages than the traditional 28 Vdc for onboard power distribution. Such is already the case for the International Space Station (ISS), which utilizes 120 Vdc. The availability of switching power supplies operating at high switching frequencies makes it important to consider the effects of these higher operating frequencies with respect to corona and gas breakdown in space applications. Such phenomena within power system components are considered unacceptable in systems where long lifetime and reliability is necessary [4]. The literature suggests that the dielectric strength of certain gases falls off drastically at frequencies of 10s of khz, which is not theoretically predictable [1]. Although there have been studies on the influence of voltage signal frequency on gas breakdown over specific frequency range, this behavior over the range below 1 MHz is not completely understood. In addition, existing data cannot be extrapolated for miniature systems with smaller electrode gaps operating at very low pressures. Our recent studies confirm that high frequency operation in space could be a major concern when designing space power systems [2], and that the breakdown voltage levels at high frequencies (< 1 MHz) can indeed be lower than the dc breakdown voltage levels, at certain pressures. Partial discharges are detrimental to a power system as they are constant sources of power loss and electrical noise (EMI). Furthermore, they can be a major problem at the component level, causing solid insulation deterioration and eventual breakdown. With the development of the next generation space and aerospace vehicles using higher voltages than traditional 28 V dc power, the need for data to design high voltage space power systems is more desirable. Currently, there are several initiatives within the government agencies (such as NASA and Air Force), planning to use 270-volt distribution power [4]. Some sub-systems also use high frequency (in the 10s of khz) voltages, for switched mode power conversion. In general, the corona or partial discharge initiation voltage is a function of several design and environmental parameters. The most important factors to be noted are the operation pressure, the electrode gap/geometry, and the frequency and voltage level of the applied power within a power system [6]. Commercial dc to dc voltage converters typically operate with intermediate frequencies in the range of 20 to 100 khz. These voltages and frequencies are considered problem areas for corona and breakdown concerns in flight vehicles subjected to low pressure environments [5]. Work supported by the Universal Technology Corp., under contract to the Air Force Research Laboratory, Propulsion Directorate, contract number F33615-02-D-2299/DO-0024 ξ email: kalyan_k@ieee.org 0-7803-9189-6/05/$20.00 2005 IEEE. 419

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 2005 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Optical Emission Characteristics Of Helium Breakdown At Partial Vacuum For Point To Plane Geometry 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Auburn University, Auburn, Alabama 36849, USA, 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADM002371. 2013 IEEE Pulsed Power Conference, Digest of Technical Papers 1976-2013, and Abstracts of the 2013 IEEE International Conference on Plasma Science. IEEE International Pulsed Power Conference (19th). Held in San Francisco, CA on 16-21 June 2013., The original document contains color images. 14. ABSTRACT In general, power devices and systems operating in vacuum or space environment are more susceptible to partial discharges, corona, or volume discharge due to the partial vacuum conditions. Partial discharge and breakdown measurements have been performed on electrical equipment operating in such environments for over decades. In spite of all the studies, fundamental understanding of partial discharge or corona initiation has not been understood completely. Various means of detection have been used over the years, including the detection of electromagnetic emissions using antennas or by observing the current through the ground cables to obtain a better understanding. The measurements are usually analyzed together with other techniques like visual inspection, transient voltage/current measurements and acoustic/optical characteristics. In this paper we present our work on optical emission characteristics of breakdown events at partial vacuum for point-to-plane electrode configuration, operating at dc and 20 khz frequency in helium. A dc-offset-ac voltage source for the high frequency experiments and a pure dc power supply for dc breakdown experiments were used. Preliminary data of voltage and current waveforms along with the light emission data are presented. The optical signal detection of this set-up includes a photo-multipliertube and a digital pico-ammeter. Optical data collected by a PMT (Photo Multiplier Tube) as a function of time is presented. Presence of optical emission was also recorded by a video camera and frame-by-frame images were used for data analysis. 15. SUBJECT TERMS

16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified 18. NUMBER OF PAGES 4 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

This paper summarizes our current work by giving a brief description of the experimental setup for optical detection followed by analysis and interpretation of the optical emission data acquired. We present the optical characteristics of helium dc and ac breakdown at partial vacuum conditions for point-plane electrode geometry. II. EXPERIMENTAL SETUP The experimental setup consists of a high vacuum chamber, high voltage power system and a data acquisition system. The vacuum chamber is equipped with an optical window in addition to the ports for voltage input/output, pressure gauges, and gas input. The electrode system consists of a stainless steel point electrode and a grounded copper plate. The point electrode is machined to a tip radius of approximately 0.5 mm and placed 1.0 cm above the plate electrode. The chamber is purged by first pumping out and then filling with helium gas for each experiment set. Once the purge is completed, helium is used as the operating gas. The chamber pressure is maintained constant throughout a particular set of breakdown events by controlling the gas inlet valve and the vacuum pump. The breakdown experiments were conducted as pressure is varied from 0.2 torr to 3.0 torr. The power supply used in these experiments is an in-house-built power source constructed from a dc in series with an ac source connected with a high frequency step-up transformer. The final signal generated by this setup is a dc-shifted sinusoid with no negative values. The applied voltage is gradually increased by simultaneously increasing the dc and the ac voltages, until a breakdown event is observed. At every pressure level, three successive breakdown events are recorded and these voltages are averaged to form the data point for that particular pressure. The chamber is then flushed with helium before taking the next data set to avoid any contamination. The experimental set-up including the power source and the diagnostics is shown in Figure 1. images and by PMT for time evolution of the light emission from the breakdown. The videos are then converted into frame-by-frame still images for better understanding the process step-by-step. We also conducted experiments with dc source to obtain dc breakdown data to compare it with the ac-high frequency data. The experimental procedures of the dc data were similar to those in ac breakdown experiments. III. EXPERIMENTAL RESULTS Preliminary studies on the high frequency breakdown of helium for this configuration were reported previously [5]. In this study, the breakdown voltage versus pressure for this configuration was presented, as shown here in Figure 2 [5]. These studies show that the breakdown voltage decreases as pressure increases. At around 1.50 torr, the breakdown curve seems to reach a steady minimum. DC breakdown data as a function of pressure for the same experimental conditions is shown in Figure 3 [5]. It was observed that the breakdown voltage characteristics under dc conditions also exhibit a pattern similar to the ac breakdown curve but with a higher breakdown voltage. In this case, breakdown voltage decreases as a function of pressure and reaches to a steady level around 1.5 torr pressure. As seen in Figure 2, the breakdown voltage characteristic for ac exhibits a pattern similar to the typical Paschen curve for dc breakdown in gases. Further data above 3 torr is needed for better comparison. Breakdown Voltage (volts) 400 380 360 340 320 300 280 260 240 220 Helium - 20 khz 200 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 Pressure(torr) Figure 2. Breakdown voltage as a function of pressure for point-to-plane electrode configuration with 1-cm gap distance for 20 khz signal [5]. 600 550 Helium - DC Breakdown Voltage (volts) 500 450 400 350 300 250 Figure 1: Experimental Setup. Voltage and current waveforms, along with the light emission data from the discharges are collected. Optical data is collected by means of video camera for optical 200 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Pressure (torr) Figure 3. Breakdown voltage as a function of pressure for point-to-plane electrode configuration with 1-cm gap distance under DC voltage. 420

frames/sec, corresponding to about 33 milli sec between each consecutive frame. (a) (a) (b) Figure 4. Voltage (top), current (middle) and optical emission (bottom) waveforms for a breakdown event at (a) 0.4 torr and (b) 1.8 torr at 20 khz applied voltage. #60 #6 #61 #7 #62 #8 (b) Figure 6. Voltage (top), current (middle) and optical emission (bottom) waveforms for a dc breakdown event at (a) 0.4 torr and (b) 1.8. A representative voltage, current and the PMT waveforms as a function of time for the ac breakdown events are shown in Figure 4 at two different pressures. The frame-by-frame images obtained by the video camera for the same experimental conditions are shown in Figure 5. The voltage and current waveforms suggest that the breakdown is a relatively short event occurring within a few microseconds. Once the breakdown is initiated, a voltage collapse and a transient current are recorded. The light emission from the electrode gap is observed for several cycles, although the voltage and current waveforms indicate this process to be in the microsecond range (Figure 4). Similar voltage, current and optical emission waveforms for dc breakdown events are shown in Figure 6 for (a) 0.4 torr and (b) 1.8 torr. The corresponding optical image data recorded by the video camera is shown in Figure 7 for these breakdown experiments. IV. DISCUSSION #63 #9 Figure 5. Optical video images of the 20 khz breakdown event shown frame-by-frame, at: 0.4 torr (left) and 1.8 torr (right). The video images are recorded with 30 Earlier studies by Pfieffer [3] for air gaps on partial discharge inception show that the breakdown voltage of inhomogeneous field gaps decreases significantly with the increasing frequency. It was also observed that the breakdown voltage falls down to as much as 50% of its value at 50 Hz if the operating frequencies are taken in 10s of khz range. The data recorded in our laboratory support that the breakdown voltages at higher frequencies are lower than the dc breakdown voltages. The data by 421

Pfieffer [3] was obtained for atmospheric pressures whereas our data is for partial vacuum conditions, thus a one-to-one comparison could not be made. #295 #221 Similar observations were recorded with the dc breakdown experiments. In this case also, there is never a complete voltage collapse across the gap. However, a breakdown does occur with observable transient current and optical emission. Once the discharge is established, a constant voltage and current are observed between the gap. Similar optical emission characteristics were also observed for ac breakdown events. It was observed that the dc breakdown events were relatively faster than the ac breakdown events. The dc breakdown events were not self-sustaining in general whereas the ac breakdowns were. V. CONCLUSIONS #296 #222 #297 #223 Figure 7. Optical video images of the dc breakdown event shown frame-by-frame, at different pressures: 0.4 torr (left) and 1.8 torr (right). In general, a low intensity glow discharge is observed around both the electrodes, but mainly seen at the cathode region (plate electrode) at higher pressure, and at the anode region (point electrode) at lower pressures. Visual inspection of the acquired images suggests that the breakdown has a lower intensity at lower pressures compared to the optical emission at higher pressures; however, this is not the case. The glow is relatively diffused at lower pressure making it appear to have a lower intensity. Optical emission waveforms recorded by PMT show that there is higher emission rate at lower pressures compared to more confined glow with lower optical intensity at higher pressure. As seen in the voltage waveforms of Figure 4, most of the breakdown events occur at the falling edge of the ac signal. Once the discharge is initiated, it becomes almost self-sustaining for few milli seconds. At the breakdown, the dc offset value decreases, allowing the signal to go negative, as seen in Figure 4. Once the breakdown is initiated, the discharge current follows the applied voltage signal. During this process, the light emission steadily increases, following a similar pattern as the current. From the video images, it can be observed that the light emission continues for several milli seconds. It was further observed that the breakdown starts with a transient current and this current magnitude increases as the pressure increases (Figures 4a and 4b). The breakdown voltage of helium operating at 20 khz in partial vacuum, for a point-to-plane electrode configuration decreases as pressure increases, until a minimum is observed around 1.5 torr. Further experimental testing is needed to conclude if a Paschen type behavior is actually present. Transient current magnitude in both ac and dc breakdown experiments was observed to increase with gas pressure, as expected. In both the cases, breakdown initiation occurs in microsecond range. At breakdown, there is no complete voltage collapse across the gap, however, a self sustained glow discharge was observed for several milli seconds. Further analysis of the optical emission is needed to fully understand the fundamental physics of the the high frequency breakdown. VI. REFERENCES [1] W. Pfeiffer, High-Frequency Voltage Stress of insulation, IEEE TEI, pp. 239-246, April 1991 [2] K. Koppisetty, H. Kirkici, Gaseous Breakdown at High Frequencies under Partial Vacuum, IEEE-CEIDP Annual Report, pp. 451-454, 2003 [3] R. Plessow, W. Pfeiffer, "Influence of the frequency on the partial discharge inception voltage", IEEE-CEIDP, Annual Report, p 97-102, 1994 [4] Spacecraft High Voltage Design Guidelines (in preparation), W. G. Dunbar, David K. Hall, H. Kirkici, D. L. Schweickart, G. Barry Hillard, NASA-AFRL Design Guide. [5] K. Koppisetty, H. Kirkici, D. L. Schweickart, Partial vacuum breakdown of helium at 20 khz for point to-plane geometry, Power Modulator Symposium 2004 and 2004 High-Voltage Workshop, pp. 38-41, 2004. [6] J. M. Meek and J. D. Craggs, Electrical breakdown of gases, Oxford, Clarendon Press, 1953. 422