COST Short Term Scientific Missions Report 24 July 2014

Similar documents
INAF Osservatorio astronomico di Torino Technical Report nr. 153

Inverted-COR: Inverted-Occultation Coronagraph for Solar Orbiter

Instrument Characteristics

The Sensors Unlimited GA1280J SWIR camera as a detector for the solar IR coronal polarimetry?

GPI INSTRUMENT PAGES

Observational Astronomy

Supplementary Materials

NIRCam Instrument Overview

Eric B. Burgh University of Wisconsin. 1. Scope

Instructions for the Experiment

The Field Camera Unit for WSO/UV

Spatially Resolved Backscatter Ceilometer

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

A NEW H-ALPHA SOLAR LIMB-PATROL SYSTEM* George Carroll. Lockheed Solar Observatory, Lockheed-California Co. Burbank, California

Radial Polarization Converter With LC Driver USER MANUAL

NIRCam optical calibration sources

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

A novel tunable diode laser using volume holographic gratings

DAVINCI Pupil Mask Size and Pupil Image Quality By Sean Adkins April 29, 2010

Coronal Magnetism, May 21-23, 2012, Boulder, Co, USA. Moscow M.V. Lomonosov University. I.S. Kim, I.V. Alexeeva, and O.I. Bugaenko

Southern African Large Telescope. RSS UW Commissioning Activities,

Simultaneous Infrared-Visible Imager/Spectrograph a Multi-Purpose Instrument for the Magdalena Ridge Observatory 2.4-m Telescope

The predicted performance of the ACS coronagraph

CorMagICS 1.0 CorMag Instrument Control Software

Tunable narrow-band filter for imaging polarimetry

BEAM HALO OBSERVATION BY CORONAGRAPH

Measurements of Infrared Sources with the Missile Defense Transfer Radiometer

erosita mirror calibration:

SHARK-NIR overview and optomechanical design: an update

OPAL Optical Profiling of the Atmospheric Limb

UNIVERSITY OF HAWAII Institute for Astronomy. f/31 High Angular Resolution Imaging Spectrograph HARIS USER MANUAL update June 10, 1997

ECEN 4606, UNDERGRADUATE OPTICS LAB

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

An integral eld spectrograph for the 4-m European Solar Telescope

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

5 180 o Field-of-View Imaging Polarimetry

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Southern African Large Telescope. Prime Focus Imaging Spectrograph. Instrument Acceptance Testing Plan

!!! DELIVERABLE!D60.2!

NIRCam Optical Analysis

1.6 Beam Wander vs. Image Jitter

The below identified patent application is available for licensing. Requests for information should be addressed to:

Coronal and heliospheric imaging instrumentation development at RAL Space

Ultralight Weight Optical Systems using Nano-Layered Synthesized Materials

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Lecture 7: Op,cal Design. Christoph U. Keller

APPLICATIONS FOR TELECENTRIC LIGHTING

A new Photon Counting Detector: Intensified CMOS- APS

Department of Mechanical and Aerospace Engineering, Princeton University Department of Astrophysical Sciences, Princeton University ABSTRACT

Big League Cryogenics and Vacuum The LHC at CERN

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Gemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996

BAFFLES DESIGN OF THE PROBA-V WIDE FOV TMA

MONS Field Monitor. System Definition Phase. Design Report

MSPI: The Multiangle Spectro-Polarimetric Imager

New Optics for Astronomical Polarimetry

Telecentric lenses.

Solar Optical Telescope (SOT)

A new Photon Counting Detector: Intensified CMOS- APS

OptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

EE119 Introduction to Optical Engineering Spring 2002 Final Exam. Name:

How-to guide. Working with a pre-assembled THz system

Spectroscopic Instrumentation

Corundum C Axis Device for Sample Preparation Timothy Thomas, M.E., M.S.E.E. GIA Laboratory June 4, 2009

TriVista. Universal Raman Solution

Classical Optical Solutions

Laser Speckle Reducer LSR-3000 Series

MS260i 1/4 M IMAGING SPECTROGRAPHS

TOWARD A NEXT GENERATION SOLAR CORONAGRAPH: DIFFRACTED LIGHT SIMULATION AND TEST RESULTS FOR A CONE OCCULTER WITH TAPERED SURFACE

Optics for the 90 GHz GBT array

ADVANCED OPTICS LAB -ECEN 5606

Section 2 concludes that a glare meter based on a digital camera is probably too expensive to develop and produce, and may not be simple in use.

1/8 m GRATING MONOCHROMATOR

Scaling relations for telescopes, spectrographs, and reimaging instruments

Recent Progress in Vector Vortex Coronagraphy

TECHNICAL REPORT NO. 82 FIGURE 1. CHARA-NOAO Beam Combiner version 1, conceptual layout. TABLE 1. Optics and optical mounts Optic Description Diameter

Introduction of New Products

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Section 3. Imaging With A Thin Lens

Optical design of Dark Matter Telescope: improving manufacturability of telescope

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers

Exp. No. 13 Measuring the runtime of light in the fiber

Oriel MS260i TM 1/4 m Imaging Spectrograph

Far field intensity distributions of an OMEGA laser beam were measured with

Parallel Mode Confocal System for Wafer Bump Inspection

Optics Laboratory Spring Semester 2017 University of Portland

ARCoptix. Radial Polarization Converter. Arcoptix S.A Ch. Trois-portes Neuchâtel Switzerland Mail: Tel:

Chapter Ray and Wave Optics

Technical Synopsis and Discussion of:

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Astr 535 Class Notes Fall

Laser Diode Mounting Kits

Matthew R. Bolcar NASA GSFC

LEOK-3 Optics Experiment kit

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

LSST All-Sky IR Camera Cloud Monitoring Test Results

Transcription:

COST Short Term Scientific Missions Report 24 July 2014 STSM Guests: Marco Romoli, Maurizio Pancrazzi Home Institution: University of Florence INAF Osservatorio Astrofisico di Arcetri (OAA), Italy Host Institution: Astronomical Institute Slovak Academy of Sciences, Tatranska Lomnica (SK) Contact Scientist: Jan Rybak, Period: 9-15 June 2014 STSM Title: Polarimetry of the solar corona with the Turin-filter at Lomnicky Observatory: stray light characterization and data pipeline test. COST STSM Reference Numbers: COST-STSM-MP1104-16828; COST-STSM-MP1104-16829; Scientific Report Backgroud and Objectives of the STSM The goal of this STSM was the optimization of the CorMag control and data acquisition software developed by INAF-Turin and the characterization of the stray light of the instrument. CorMag accommodates the liquid crystal Lyot filter, for the FeXIV 530.3 nm line, developed by the INAF - Turin Astrophysical Observatory (OATo), Italy and has been integrated to the Zeiss coronagraph of the Lomnicky Peak Observatory (LSO), Astronomical Institute of the Slovak Academy of Sciences (AISAS), in Tatranská Lomnica, Slovakia. The result of this STSM was positive as we tested the control and data acquisition software and we identified the origin of the ghosts detected during the past STSM and tested a new optical configuration for CorMag. Summary of all the STSM at Lomnicky Peak Observatory During the first STSM to Lomnicky Peak Observatory in October 2013, we had achieved the following goals: 1. Design and manufacturing of dedicated opto-mechanical interfaces to integrate the Turin CorMag to the Lomnicky Zeiss coronagraph; 2. Integration of CorMag on the Zeiss coronagraph and optical alignment; 3. Integration of CCD camera detector and of Lyot filter driving electronics; 4. Installation on local PC of the Lyot-filter/camera control & data acquisition (C&DAQ) s/w. In the second STSM, last April, we completed the following tasks:

1. Manufacturing of a baffle installed between the CorMag and the focal plane of the Zeiss coronagraph in order to suppress the light-leak ; 2. Manufacturing of a mechanical interface to integrate a hot mirror filter to block a red leak responsible of a low contrast in images; 3. Manufacturing of a screen used for aligning the solar image with the internal occulter; 4. Training of the AISAS staff to operate the CorMag by the INAF team; 5. Update of the the Lyot-filter/camera control & data acquisition (C&DAQ) s/w; 6. CorMag First-light and data archiving. In this third STSM, last June, we completed the following tasks: 1. Feasibility of new optical configuration to minimize the ghosts : 2. Implementation of the CorMag optical configuration inside the Zeiss coronagraph converging beam; 3. Test of the new CorMag optical configuration; 4. Update of the the Lyot-filter/camera control & data acquisition (C&DAQ) s/w 5. Detailed definition of future activity in preparation of the next campaign in September 2014. Activities performed in preparation for the STSM (J. Rybak at LSO). In order to minimize the presence of ghosts in the CorMag image a new optical configuration has been studied to reconfigure the filter from the current collimated beam to the f/20 converging beam of the Zeiss coronagraph, similar to the Coronal Magnetograph and Polarimeter Slovak (Comp-S) of the twin Zeiss coronagraph: The camera optics will be dismounted without changing the connection of the camera and rear part of the filter The bandpass filter can be fixed directly to the rear plane of the coronagraph placing the body of the filter into the rear box of the coronagraph body Collimating optics in front of the filter and its holder will be removed Activities carried out during the STSM. Implementation of the CorMag interfaces inside the converging beam During the first day of the STSM, the Lyot filter body was dismounted from the arm, the relay lenses removed on both side of the filter, the IR blocking filter, the structure holding all electronics devices and the camera were removed. The Lyot filter body was mounted to the rear plate of the coronagraph and the structure holding all electronics devices mounted to the rear part of the coronagraph, as shown in Fig. 1. The camera was mounted to the filter and the focus adjusted. The IF hot-mirror filter was mounted in front of the bandpass filter with different tilt angles to test the presence of ghosts on the image.

Fig. 1 General view of the CorMag present mechanical accommodation Test of new CorMag optical configuration The former accommodation of the Lyot filter assembly was on the coronagraph translation stage positioned at 70mm. The new accommodation will be with the translation stage at 100mm. The fixed distance re-imaging lens - CCD box is 369 mm. This implies that the CCD has to be moved toward the coronagraph by 30mm (see Fig. 2). The CorMag first-light tests of past STSM revealed the presence of ghost images at the center of the frames (Fig. 3).

Fig. 2 CorMag general view without the IR blocking filter in front will long interface between flange and CCD camera Fig. 3 - Example of CorMag acquisition of four polarimetric images of the diffuser at different orientations of the LC polarimeter showing several ghosts distributed on the image. The solar limb is the circular sector at the bottom of each image. During the STSM, there were no coronagraphic sky conditions and the skies were dominated by the presence of cirruses, allowing to calibrate CorMag for ghosts, but no data of the Fe XIV line could be acquired.

The CorMag tests revealed the presence of ghost images at the center of the frames but of reduced extension with respect to the previous collimated optical configuration, leaving a region located near the center and close to the limb clean from ghosts (Fig. 4). We have carried out some tests in order to locate the source of the ghosts. Candidate sources are the narrow bandpass pre-filter of the LC Lyot filter, the hot-mirror filter and the back surface of the Coronagraph camera lens. Fig. 4 CorMag image (after mdc and mff corrections) obtained with normal incidence NB prefilter + IR blocking filter in front of itit is the sum of the total emission in 11 spectral positions around 530.28nm. Update of the the Lyot-filter/camera control & data acquisition (C&DAQ) s/w Fig. 5 shows a schematic diagram of the architecture of the data acquisition, instrument control and data storage (C&DAQ). The components of the CorMag instrument (i.e., CCD Camera and Liquid Crystals Tunable Filter) are connected to the control computer (ICC) through a 30-meter fiber-optics with the USB/FO extender. The ICC is the computer controlling the instrumentation, acquiring data and responsible for the temporary data storage. This computer is remotely connected to the Remote Computer (RC). The data acquired are downloaded on the Data Storage (DSAISAS) hosted by the Astronomical Institute of the Slovak Academy of Science. The report of the 2013 STSM also describes the architecture.

Fig. 5 - Schematic diagram of the instrument control, data acquisition and data storage architecture. The release 3.0 is now available.this new release of the Lyot-filter/camera control & data acquisition (C&DAQ) s/w was tested and one bug repaired in the code for Manual mode. Future activity in preparation of new STSM campaign of September 2014 The next STSM campaign has been scheduled in September. The September/October period is usually the best time of the year in terms of weather for coronagraphic observations from the Lomnicky Stit Observatory. This will provide the best opportunity for testing the improved interface configuration for the CorMag/Zeiss-coronagraph discussed in this report. In summary, the activity to be carried on in preparation of next September campaign is: Preparation of CorMag in order to work inside the coronagraph converging beam Check of new CorMag configuration with optical CAD Mechanical modifications to the Lyot filter mount Preparation of CorMag for the coronagraph converging beam The CorMag assembly will be modified in order to: - Place the Lyot filter in the converging beam. - Place the Lyot filter as close as possible to the focal plane in order to: o Limit the vignetting of the coronograph converging beam o minimize multiple reflections between the coronagraph re-imaging optics and the Lyot filter o Allow the insertion and the removal of auxiliary optics, such as the pre-polarizer - Have the option of moving the pre-filter more distant from the Lyot filter - Have the option of mounting a new pre-filter tilted to the optical axis

- Have the option of mounting the hot mirror in front of the pre-filter or alternatively, mount the hot filter in front of the CCD camera. - Interface the pre-polarizer and the white screen with entrance aperture of the Lyot stop. Possible configurations: (Pre-pol) - Hot mirror - Pre-filter - Lyot filter - CCD (Pre-pol) - Pre-filter - Lyot filter - Hot mirror - CCD The Lyot filter assembly will be mounted inside the box that contains the re-imaging lens (called in the following black-box) in order to take advantage of the implementable thermal control. The Lyot filter assembly will be attached with screws by the side facing the CCD on the black interface flange (shown in Fig. 6), which will be attached to the translation stage of the blackbox. The present accommodation of the Lyot filter assembly is on the translation stage positioned at 70mm. The new accommodation will be with the translation stage at 100mm. The fixed distance re-imaging lens - CCD box is 369 mm. This implies that the CCD has to be moved toward the coronagraph by 30mm (see Fig. 9). Fig. 6 Black interface flange (its ears will be not needed) Things to be checked with optical design software 1. Size of converging beam to assess vignetting (adapting the aperture diameter to an optimum vignetting) 2. Best position of the Lyot filter with respect to the coronagraph focal plane in order to minimize the vignetting of the coronagraph converging beam. 3. Tilt of hot mirror in both options (in order to minimize effects of the reflactions in the rest of the CorMag and coronagraph optics) 4. Tilt of pre-filter (in order to minimize effects of the reflactions in the rest of the CorMag and coronagraph optics) considering a purchase of a new NB prefilter prepared for the green

line with the desired inclination 5. Aperture and the pre-polarizer mounting flange (see Fig.4) Fig. 7 Instrument entrance aperture and the pre-polarizer mounting flange Mechanical modifications to the Lyot filter mount are needed (see CAD drawing Fig. 9): 1. Front section (Part B) redesign to accommodate the hot mirror (Option 1) and to allow a repositioning of the pre-filter more advanced with respect to the Lyot filter and, if possible, its rotation in azimuth. 2. Flange to interface the pre-polarization mount and the white screen to the outer envelope (Part A) 3. Back section (Part C) redesign to accommodate the hot mirror (Option 2) and, if possible, its rotation in azimut 4. Redesign of the three sections (Part D, E, and F) to shorten the distance of the CCD to the Lyot filter assembly by 30 mm 5. Design extension of Lyot filter device (Part L) to reposition the pre-filter The described configuration keeps the Lyot filter assembly inside the black-box, which will allow to implement a thermal control inside the black-box by means of a controlled heater (AISAS task for October 2014). Alternatively the Lyot filter can be moved closer to the focal plane up to 50 mm. In this modification the filter will be farther from the re-imaging optics but it will extent outside of the black box and its heating will be more difficult.

Fig. 8 Mechanical modifications to the Lyot filter mount In Fig.6 is shown a concept for the accommodation of the filter for both option 1 and option 2.

Fig. 9 Concept for the accommodation of the hot filter and the pre-filter for option 1 (above and option 2 (below).