The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.

Similar documents
The theoretical concept


Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

Through and Ground Conductor Terminal Blocks 290 Series

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

7/16 DIN Male Right Angle Connector Clamp/Solder Attachment for RG213, RG214, RG8, RG9, RG225, RG393, RG215

Low Loss Pre-Connectorized Cable Sets, LL58 Series, DC-3.5GHz

7/16 DIN Male Connector Clamp/Solder Attachment for RG213, RG55, RG141, RG142, RG223, RG400, RG303, PE-C195, PE-P195, LMR-195

7/16 DIN Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

Relays and associated toroids

HE Insert Series. Application Specification Apr 26 th, 2016 Rev. A. Table of contents

DIK 1,5 General data Technical data General

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

Cutting. Contents. Cutting. Cutting Introduction B.2 B.1. Cutting tools B.4. Front cable cutter B.6. Cable cutter B.7. Cutting and releasing tools B.

RTD-6M PD SENSOR BOARD

General data. Technical data DIKD 1,5. General. Dimensions

Omnidirectional Antenna Vertical Polarization Indoor and outdoor use

Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No.:

STAMPING TECHNOLOGY - CLAMPING RAW PARTS

Bluetooth DRO Installation for Bench Mills

May 14, Installation Manual

MULTI CONNECTION SYSTEM. Product Overview

Cannon Trident Connectors

SLKK 5. Extract from the online catalog. Order No.:

RP SMA Male Right Angle Connector Solder Attachment for PE-SR402AL, PE-SR402FL, RG402

Premoulded cable joint SMPGB

WINSTA The Connection System. Full Line Catalog 2010/2011

Data sheet... W-Series WDU 2.5

Data sheet. W-Series WDU 2.5

HN Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

N Male Connector Clamp/Solder Attachment for RG17, RG218, RG219

Switching relay terminal block; Relay with 1 changeover contact (1u); with miniature switching relay

Data sheet. W-Series WDU 2.5 RT

METRIC LIGHTNING PROTECTION PRODUCTS

PIFOC QuickLock Thread Adapter

Ground Clamps Cable Tray

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

Easy Step by Step Manual

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

8-channel digital input module; 24 VDC; 3.0 ms; high-side switching; 1-conductor connection

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Hydrajaws Safety Lifeline Tester

78-Way D-type Connector Accessories

The Queen Quilter Professional Quilters Kit Frame

Operating manual. TruTool N 500 (1A1) english

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES

Bedienungsanleitung - Operating Instructions - Mode d emploi

NOV 16 Rev L

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

TBX-68S Isothermal Terminal Block

SMA Male Connector Crimp/Solder Attachment for RG58, RG303, RG141, PE-C195, PE-P195, LMR-195, inch

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

INTRODUCTION A WIDE STANDARD RANGE MANY FULL CRIMP MODELS LOW INTERMODULATION CONNECTORS

Datenblatt. W-Series WDU 2.5

Ceiling Tile Installations Part 1. Sheetrock Installations Part 2. WolfVision Support 2055 Sugarloaf Circle, Suite 125 Duluth, GA 30097

Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment.

ELECTRICAL INFORMATION K012-A135-MP5.0/02 2 K012-A135-MP5.0/03 3. Molding Nylon PA66 to UL94, V-O Colour Green. Torque 3.5 lbs-in

Setting Standards Connectors M 16

Model S9v. 43 Multiband Vertical Antenna Installation Guide

Safety switches with slotted hole lever

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Installation Guide for Panel Mount Product

Instruction Sheet Tool Kit [ ] (for SL Series 110 Jack Connectors)

Data sheet. W-Series WDU 10

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

Mounting instruction of PressFIT-pin type Small-PIM

Data sheet. W-Series WDU 4 BL

LC31L-BAT Link Coupler

Clamping devices - mechanical

TOOL STAND. Model No. CUTS1 ASSEMBLY INSTRUCTIONS 0513

Operator's manual TruTool PN 130 (1A1)

MICC Ltd Unit 21 Sedling Road Wear East Industrial Estate Washington Tyne & Wear NE38 9BZ Tel: +44 (0)

Medium HoneyBadger Chase Rack Installation Instructions

Bluetooth DRO Installation for Mini Mills

Automation and Network Solutions. Entertainment in Series Round Connectors by HIRSCHMANN.

ELECTRICAL INSTALLATION PRODUCTS Splicing Connectors and Chassis Mount Terminal Blocks

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A

SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188 Gold Plated

SERIESN50, COAXIAL CONNECTORS

SMA Male QD Connector Crimp/Solder Attachment For RG142, RG223, RG400, RG55

RAILING. Installation Guide

EuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System

Anchor Kit Installation Guide

Installation instructions, accessories. TV receiver, digital

Pro-Weigh 84/SS/FLP Lo Pro 90 / SS Installation Guide. Version 1.0

INSTALLATION INSTRUCTIONS FOR SL-LB MANUAL LIFT BARRIER GATE ARMS

50, ,000 18,800 8,000. CODE 04 ER (ER ) UPC Chuck/W ITS Central Chuck. CODE 04 ER (ER ) UPC Pallet For Alignment

Hy-gain. Method 1 : Completely assemble the antenna on the ground then hoist it into position using a setup as shown in Figure 1.

Edition January 2008

Assembly Instructions for 12x16 Floating Dock

Submersible Turbine Assembly Manual

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Assembly Instructions

Before Lock Installation Surface Mount Installation. Door Preparation

Installation Fence Guide Kodiak Iron. Exceptional Fencing Extraodinary Customer Service

Ten Port Multi-Band Antenna

Our service team is at your disposal for further information. Franke GmbH Obere Bahnstr Aalen Germany Tel.: /920-0 Fax.

10. Mini Coax Connectors

Transcription:

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.

Shield (Screen) Connecting System VOLUME 1 Shield (screen) connecting system Mounting options based on application, description and handling.3 Shield (screen) clamping saddles.4.5

2 Shield (Screen) Connecting System Product Summary Shield (screen) clamping saddle 11 mm /0.433 in wide 19 mm /0.748 in wide 27 mm /1.063 in wide 43 mm /1.693 in wide Page.5 Page.5 Carrier with grounding foot bar 90 to the rail with grounding foot bar parallel to the rail with 2 grounding feet bar parallel to the rail Carrier rail Stand off with special perforations Insulated mounting foot for special perforated carrier rail Straight busbar U-shaped busbar for insulated mounting foot Cu 10 mm (0.394 in) x 3 mm (0.118 in) Pages.4/.5

Shield (Screen) Connecting System Description and Handling 3 Carrier with grounding foot* 45 mm/1.772 in long, busbar 90 to the rail 790-113 Applications Carrier with grounding foot* 45 mm/1.772 in long, busbar parallel to the rail 790-114 Carrier with 2 grounding feet* 5 mm/4.921 in long, busbar parallel to the rail 790-115 * for all sizes of shield (screen) clamping saddles on special slotted carrier rail carrier with grounding foot, busbar parallel to the rail insulated mounting carriers for a common shield (screen) reference potential, independent of the housing potential U-shaped copper busbar 10 mm (0.394 in) x 3 mm (0.118 in) Negative shield (screen) attenuation db 0-10 - 20-30 - 40-50 - 60 Admissible limiting value - 70-80 - 90-100 0,01 0,1 1 10 100 MHz snap into any metal plate up to max. thickness 3 mm /0.118 in The WAGO shield (screen) connecting system is highly effective because the clamping unit can be brought very close to the unshielded part of the cable. Additionally, the spring material is Hole dimensions for panel mounting Shield (screen) clamping saddle size Distance X 11 mm 9.5 mm Distance Y 19 mm 17.5 mm 27 mm 25.5 mm 43 mm 41.5 mm ( X ) < 14 > > 4 < < Y > part of the clamping saddle, giving good electrical connection and compensating for any deformation in the braiding. The system also acts as a partial strain relief. > 2 < max. 3 > <

4 Shield (Screen) Clamping Saddles 11 mm / 0.433 in wide For conductors with a diameter of up to 8 mm / 0.315 in 19 mm / 0.748 in wide For conductors with a diameter of 7 mm / 0.276 in to 16 mm / 0.63 in Note: Cannot be used for the connection of ground (earth) conductors! Description incl. knurled screw Diameter of connectable conductor Accessories Application notes Carrier w. grounding foot, bar 90 to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu w. tin plating Carrier w. grounding foot, bar parallel to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu w. tin plating Carrier w. 2 grounding feet, bar parallel to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu w. tin plating Carrier rail, special perforated, 1000 mm/3.3 long, Cu with tin plating, special lengths on request Stand off, for special perforated carrier rail, use M 5 size screw Straight busbar, 10 mm (0.394 in) x 3 mm (0.118 in), bar Cu with tin plating Insulated mounting foot, for busbar, with standard screw M4 x 8 mm Insulated mounting foot, for busbar, with sheet metal screw (3.5 x 9) mm U-shaped busbar, 10 mm (0.394 in) x 3 mm (0.118 in), Cu with tin plating 11 mm/0.433 in wide up to 8 mm /0.315 in 790-108 50 5 mm /4.921 in long see drawing on page.5 19 mm /0.748 in wide 7 mm /0.276 in to 16 mm /0.63 in 790-116 50 5 mm /4.921 in long see drawing on page.5 The shield (screen) clamping saddle is shipped ready for direct connection to the busbar 10 mm (0.394 in) x 3 mm (0.118 in) or to a drilled mounting plate. After connection, tighten the knurled screw to complete the installation. Recommended tightening torque: 0.5 Nm To remove a shield (screen) clamping saddle, unscrew until ratcheted mechanism is released, then slightly tip saddle and remove the clamping saddle. Assembly Removal

5 27 mm / 1.063 in wide For conductors with a diameter of 6 mm / 0.236 in to 24 mm / 0.944 in 43 mm / 1.693 in wide For conductors with a diameter of 22 mm / 0.866 in to 40 mm / 1.575 in 27 mm /1.063 in wide 6 mm /0.236 in to 24 mm /0.944 in 790-4 50 43 mm /1.693 in wide 22 mm /0.866 in to 40 mm /1.575 in 790-140 50 5 mm /4.921 in long 5 mm /4.921 in long < A > < B > ><_ 4 > 15 <_ 3 < C > > 6< < 10 > see drawing on on the right see drawing on on the right Dimensions in mm Pack.unit A B C 790-190 63 60 83 25 (5 x 5) suitable for I/O module series 750 (5 E/A) 790-191 100 60 118 25 (1 x 25) suitable for I/O module series 750 (8 E/A) 790-192 63 35 83 25 (5 x 5) 790-193 100 35 118 25 (1 x 25) Installation position delivery state < A > Closed position < F > Removal position < E > Dimensions in mm A B C D E F 790-108 51 15 8 16 55 42 790-116 53 15 16 16 57 45 790-4 78 15 24 16 83 58 790-140 97 15 40 16 100 73 (_ 10 _) < B > (_C_) (_C+3_) (_10,1_) < 17 > < D >