Pocket Size Digital Multimeter Models: and

Similar documents
Model : OPERATING MANUAL

Digital Clamp Meter Model: &

Pocket Size Digital Multimeter with USB Model: A & A

Digital Multimeter with Backlight

DIGITAL MULTIMETER AUTORANGING

Table of Contents GDM-356. Page

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

True RMS Digital Multimeter Model:

Model UT39A/B/C: OPERATING MANUAL

Table of Contents Title Page

Model : OPERATING MANUAL Table of Contents (1)

Digital Multimeter, Pen Type

INSTRUCTION MANUAL DIGITAL MULTIMETER

Model UT50D: OPERATING MANUAL. Table of Contents

OPERATOR S INSTRUCTION MANUAL

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

The Meter Structure The Figure 2-1 shows the Meter structure.

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Mini Clamp Meter Model:

AMM-1022 Digital Multimeter USER`S MANUAL

Model UT20B: OPERATING MANUAL Table of Contents (1)

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

User Manual Digital Multimeter

User Manual Digital Multimeter. model no.: MSR-U1000

MODEL: D03128 CLAMP METER

DMM8900 SERIES USERS MANUAL

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

KMD-S04 Multímetro de bolsillo

DVM1190 DIGITAL MULTIMETER

Model DIGITAL MULTIMETER

DIGIT & POINTER MULTIMETER

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETER INSTRUCTION MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

3B SCIENTIFIC PHYSICS

Handheld Digital Multimeter

Model UT10A: OPERATING MANUAL Table of Contents (1)

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Sales: Technical: Fax:

ProfiScale MULTI Multimeter

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Handheld Digital Multimeter PRO-50A

Model UT201/202: OPERATING MANUAL. Table of Contents

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Title Page Overview Unpacking Inspection Safety Information

Handheld Digital Multimeter

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

User Manual. All rights reserved. Specifications are subject to change without notice.

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

OS-81B TECPEL CO. LTD.

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

R/C SMD Tweezers Multimeter Model RC200

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Model: &

NOTE: Fully read and understand this manual before using this Digital Multimeter.

User Manual. All rights reserved. Specifications are subject to change without notice.

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

M-1000D DIGITAL MULTIMETER

AUTO RANGING DIGITAL MULTIMETER

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

METRAVI. Table of Contents

DIGITAL MULTIMETER AX-588B

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

15B & 17B. Multimeters. Users Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Analog Technologies. Multimeter 15B and17b

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

MS8223A. CAT.IIi 600 V

Model A/ A: OPERATING MANUAL TABLE OF CONTENTS

DIGITAL CLAMP METER Use s Manual

VC820/VC840 OPERATING MANUAL. Table of Contents

AC/DC CLAMP METER USER S MANUAL

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

USER'S MANUAL DMR-6700

15B & 17B. Users Manual. Multimeters

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

DM-45 Digital Multimeter

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

1.General instructions Specifications Description...7

DCM730. Digital Clamp Meter User s Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

400Amp True RMS AC/DC Clamp Meter Model EX613

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

79/26 Series III Multimeter

Transcription:

Pocket Size Digital Multimeter Models: 72-8150 and 72-8155 1

IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. Please operate according to this manual, otherwise the protection provided by the device will be impaired or fail. Check the test leads, probe and case insulation condition before using. If you find any breakage, damage or abnormality, or you consider the device is broken, stop using the device immediately. When using the test probes, keep your fingers behind the finger protection rings. Ensure all inputs are less than the range selected otherwise it may cause electrical shock or meter damage. Do not apply voltage to the meter. Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, capacitance or diodes. Do not use the meter with the back cover removed. Do not adjust the range selector during measurement. Replace the batteries as soon as the low battery indicator appears on the display. Remove dead batteries from the meter or if it is not going to be used for a long time. Never mix old and new batteries together, or different types of batteries. Never dispose of batteries in a fire, or attempt to recharge ordinary batteries. Before replacing the battery, turn off the meter and disconnect all the test probes. To prolong battery life turn off the meter after use.. ELECTRICAL SYMBOLS GUIDE Low battery Grounding Continuity Double insulated Diode Capacitance Lx Inductance Fuse Warning WHAT S INCLUDED Digital Multimeter 1 pair of test leads with clips. 9V battery (not installed). OVERVIEW Function Buttons The following table provides information regarding the functional button operation. Button Description Power Press once to turn the meter on / press again to turn the meter off L-C (72-8155) Zero cap (72-8150) Press DOWN to enter capacitance measurement. Press UP to enter inductance measurement. Press to adjust small capacitance to zero. 2

1. LCD display 2. L-C switch / zero capacitance adjustment switch 3. Transistor jack. 4. Resistance, diode and continuiyty terminal. 5. Capacitance and inductance terminal. 6. Range selector. 7. Power. 7 6 1 2 3 5 4 RANGE SELECTOR FUNCTIONS AND DISPLAY No Symbol Meaning 1 H Data hold is active. 2 The battery is low. 3 ß Transistor test. 4 Diode test. 5 The continuity buzzer is on. 6 Measurement of unit of capacitance. pf Picofarad. 1 x 10-12 or 0.000000000001farads. nf Nanofarad. 1 x 10-9 or 0.000000001farads. μf Microfarad.1 x 10-6 or 0.000001 farads. mf Millifarad. 1 x 10-3 or 0.001 farads. 7 8 Ω kω MΩ H mh Measurement of unit of resistance. Ohm. kiloohm. 1 x 10 3 or 1000 ohms. Megaohm. 1 x 10 6 or 1,000,000 ohms. Measurement of unit of inductance. Henry. mh. Millihenry 1 x 10-3 or 0.001 henry. 3

OPERATION Measuring Resistance. To measure voltage, do the following: 1. Insert the red test clip into the Ω terminal and the black test clip into COM terminal. 2. Set the range selector to Ω. The resistance ranges are 20Ω, 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ and 2000MΩ. Connect the test clips across the object being measured. The measured value shows on the display. Note: When measuring at 20Ω and 200Ω range, the test clips can add 0.1 to 0.3Ω error to resistance. To obtain precise readings in these lowresistance measurement, short circuit the input terminals beforehand and record the reading obtained and subtract this from the measured reading displayed. The meter displays 1 when there is no input, for example, open circuit situation. For high resistance measurement (>1MΩ), it is normal to take several seconds to obtain a stable reading. When resistance measurement has been completed, disconnect the connection between the test clips and the circuit under test and remove the test clips from the input terminals of the meter. Measuring Continuity. To test for continuity, do the following: 1. Insert the red test clip into the Ω terminal and the black test clip into the COM terminal. 2. Set the range selector to. Connect the test clips across with the object being measured. The beeper sounds continuously when the resistance value of the tested circuit 10Ω. The beeper may not sound when the resistance value of the test circuit >100Ω. The meter displays the value of the test resistance. 4

Measuring Diode. Use the diode test to check diodes, transistors, and other semiconductor devices. The diode test sends a current through the semiconductor junction, and then measures the voltage drop across the junction. Note: A good silicon junction drops between 500mV and 800mV. To test a diode out of a circuit, do the following: 1. Insert the red test clip into the Ω terminal and the black test clip into the COM terminal. 2. Set the range selector to. For forward voltage drop readings on any semiconductor component, place the red test clip on the component s anode and place the black test clip on the component s cathode. The display shows the diode forward voltage drop s nearest value. When diode test has been completed, disconnect the connection between the test clips and the circuit under test and remove the test clips from the input terminals of the meter. Transistor testing. To test transistors, do the following: 1. Set the rotary switch to hfe measurement mode. Check if the transistor is PNP or NPN type 2. Insert the transistor to be measured to the corresponding Transistor Jack. The display shows the transistors nearest value. When transistor measurement has been completed, disconnect the connection between the test clips and the circuit under test and remove the test clips from the input terminals of the meter. 5

Measuring Capacitance. To measure capacitance, do the following: 1. Insert the red test clip into the CAP+ terminal and the black test clip into the CAP- terminal. For small value capacitor measurement, insert the capacitor into the small value jack. 2. Set the range selector to F. If the value of capacitor to be measured is unknown, use the maximum measurement position 600μF and decrease the range step by step until a satisfactory reading is obtained and the overload icon 1 is not showing. When testing polarized capacitors, use the red test clip on the capacitor s positive lead, and the black test clip on the capacitor s negative lead. With nonpolarized capacitors, either direction is acceptable. When measuring small value capacitor, that is 200pF, 2nF and 20nF, first open circuit the test clips or the Small Value Capacitance Jack, then turn the Capacitance Zero Adjustment Switch to adjust zero (72-8150 model). The meter displays the measured value. When capacitance measurement has been completed, disconnect the connection between the test clips and the item under test and remove the test clips from the input terminals of the meter To minimize the effect of capacitance stored in the test clips, the test clips should be as short as possible. Note: The meter cannot check the quality of the capacitor. Stable and solid connections are essential when measuring large capacitors. When the tested capacitor is leaking or damaged and the tested value is not stable, the capacitor may have problems. You need to use other tools or equipment to check and confirm. 6

Measuring Inductance (72-8155 only) To measure inductance, do the following: 1. Set the rotary switch to Lx measurement mode. If the tested inductance value is unknown, use the maximum measurement position and decrease the range step by step until a satisfactory reading is obtained. 2. Insert the test clips into the corresponding Lx input terminals. The measured value shows on the display. When measuring inductors in the 2mH range, you should first short circuit the test leads and note the measured inductance value of the leads. Then the correct reading is the measured reading, minus the short circuit value. The small value jack on the surface of the meter should be used when measuring small value inductors. Note: The meter cannot check the quality of the inductance. When inductance measurement has been completed, disconnect the connection between the test clips and the circuit under test and remove the test clips from the input terminals of the meter. BATTERY AND FUSE REPLACEMENT If icon appears on LCD, please replace the battery as follows: 1. Disconnect test probes from circuits being measured, turn range selector to OFF Screw position. 2. Remove the screw from the battery cover, and separate the battery cover from the rear casing. 3. Replace the 9V alkaline battery with a new one (NEDA1604 or 0062 or 6F22 or 006P) noting the correct polarity. 4. Refit the battery cover and tighten the screw. Battery 7

Replacing the Fuses. Warning: To avoid electrical shock, personal injury or damage to the meter, use specified fuses ONLY in accordance with the following procedure. 1. Turn the meter power off and remove all connections from the terminals. Screw 2. Remove the screw from the battery compartment, and separate the battery compartment from the case bottom. 3. Remove the screws from the case bottom, and separate the case top from the case bottom. 4. Remove the fuse by gently prying one end loose, then take out the fuse from its holder. 5. Install ONLY replacement fuses with the identical type and specification as follows and make sure the fuse is fixed firmly in it s holder. Fuse 1: 0.315A, 250V, fast type fuse, 5x20 mm. 6. Replace the battery compartment and the case top, and reinstall the screw. 7. Replace the case bottom and case top, and reinstall the screws. Note: Fuse replacement is seldom required. Blown fuses are typically a result of improper use. 8

SPECIFICATIONS Maximum Display 1999. Measurement Speed Polarity Overload Indication Display 1 Range Capacitance zero adjustment Temperature: Operating Storage Updates 2-3 times /second. Auto. (Display - when negative) Manual Ranging around ±20pF 0 o C~40oC (32 o F ~104 o F). -10 o C~50 o C (14 o F~122 o F). Relative Humidity 75% @ 0 o C - 30 o C; 50% @ 31-40 o C. Altitude Operating: 2,000 m. Storage 10,000 m. Battery Type One piece of 9V Alkaline (NEDA1604 or 0062 or 6F22 or 006P). Low Battery Dimensions Weight Safety/Compliances Display 6.77 (H) x 3.27 (W) x 1.50 (D). Approximate 310g (including battery). EMC EN61326. 9

ACCURACY Accuracy specifications Accuracy: ±(a% reading + b digits), guarantee for 1 year. Operating temperature: 23 o C ± 5 o C. Relative humidity: < 75%. Temperature coefficient: 0.1 x (specified accuracy) / 1 o C Resistance Test Range Resolution Accuracy 200Ω 0.1Ω ±(0.8%+3) 2kΩ 1Ω 20kΩ 10Ω 200kΩ 100Ω ±(0.8%+1) 2MΩ 1kΩ 20MΩ 10kΩ ±(2%(rdg-12)+5) Remarks: Overload protection: 250V DC or AC rms at all ranges. At 20M range, short circuit test lead, LCD displaying 12 digits is normal. During measurement minus these 12 digits from the obtained reading. When measuring 20Ω and 200Ω range, short circuit test clips to display the resistance value of the test lead. Subtract this value from the measurement value to obtain the correct tested value. Continuity and Diodes Function Range Resolution Overload Protection Diode Continuity 1mV Diode: Open Circuit Voltage around 5.8V, forward current around 1mA. Continuity 10Ω, beeper sounds continuously. > 10Ω, beeper may or may not sound. 1Ω 250mV Transistor Range Resolution Testing Condition Remarks hfe 1ß Vce 5.8V I bo 10μA 10 The display value is the tested transistor s (NPN, PNP) nearest value (0~1000ß)

Inductance Test Range Resolution Accuracy Testing Frequency/Current 2mH 20mH 200mH 0.001mH 0.01mH 0.1mH ±(2%+8) 2H 0.001H ±(5%+5) 1kHz/150µA 20H 0.01H ±(5%+15) 100Hz/15µA Measure of Inductance: 1H=103mH = 106μH. Overload Protection: 0.315A, 250V, fast type fuse, 5x20 mm Inductance Test Range Resolution Accuracy Testing Frequency/Voltage 2.000nF 20.00nF 200.0nF 2.000µF 20.00µF 200.0µF 0.001nF 0.01nF 0.1nF 0.001µF 0.01µF 0.1µF ±(1%+5) ±(4%+5) 1kHz/150mV 100Hz/15mV 600µF 0.001mF Reference Only 100Hz/1.5mV Overload Protection: 0.315A, 250V, fast type fuse, 5x20 mm Measure of Capacitance: 1F=103mF = 106μF= 109nF = 1012pF Discharge all high-voltage capacitors before testing capacitance. CLEANING Periodically wipe the case with damp cloth and mild detergent. Do not use abrasives or solvents for cleaning. Clean the measurement probe tips occasionally, as dirt on the probes can affect reading accuracy. 11

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. Made in China. PR2 9PP Man Rev 1.0 12